Labshake search
Citations for Leica :
51 - 100 of 119 citations for Fmoc Rink Amide OctaGel Resin since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2023Quote: ... Resin-embedded cells were sectioned to a 250 nm nominal thickness using an ultramicrotome (Leica Artos 3D) equipped with a diamond knife (Diatome ...
-
bioRxiv - Cell Biology 2023Quote: ... the resin blocks were cut into ultrathin sections measuring 60–80 nm using an ultramicrotome (Leica UC7) and Diamond slicer (Daitome Ultra 45) ...
-
bioRxiv - Neuroscience 2023Quote: ... the empty resin at the surface was shaved to expose tissue surface using an ultramicrotome (UC7, Leica), then turned downwards to be remounted to a metal pin with conductive silver epoxy (CircuitWorks ...
-
bioRxiv - Cell Biology 2024Quote: ... The target area from the resin-embed samples were relocated and marked using dissection microscope (Leica Biosystems), then cut out from the ibidi µ-dish and mounted onto 3.18 mm diameter aluminium rods with Araldite 502/Embed 812 ...
-
bioRxiv - Developmental Biology 2021Quote: ... Slices of 25 and 30 µm were manually cut from the resin with a cryostat (Leica CM3050 S). The slices were mounted on Superfrost® Plus slides before proceeding with immunostaining.
-
bioRxiv - Cell Biology 2021Quote: ... and the resin-embedded cells were cut into 250 nm thick sections using an ultramicrotome (Leica Artos 3D) equipped with a diamond knife (Diatome ...
-
bioRxiv - Neuroscience 2022Quote: ... Pia matter was exposed by carefully removing a thin layer of resin with an ultramicrotome (UC7, Leica, Germany) equipped with a diamond-blade (Diatome ...
-
bioRxiv - Cell Biology 2023Quote: ... After the resin was cured 70-90 nm sections were cut using an ultramicrotome (EM UCT, Leica Microsystems) and collected on a 2×1 mm copper slot formvar coated grid.
-
bioRxiv - Neuroscience 2024Quote: ... resin blocks were cut into ultrathin sections (70 – 90 nm) using an ultramicrotome (UC7, Leica microsystem, Vienna, Austria), longitudinal sections of nerve bundles were collected on copper formvar carbon-coated slot grids ...
-
bioRxiv - Microbiology 2024Quote: ... fixed cells were subjected to gradient dehydration in ethanol and embedded in 618 epoxy resin (Leica Ultracul-R). Ultrathin sections were prepared using a microtome (Leica ...
-
bioRxiv - Cell Biology 2020Quote: ... Resin was polymerised at 60°C overnight and 60 nm ultrathin sections were cut on an Ultracut 6 (Leica) ultramicrotome and imaged as described above.
-
bioRxiv - Cell Biology 2020Quote: ... The polymerized resins were ultrathin-sectioned at 70 nm with a diamond knife on an ultramicrotome (Ultracut UCT; Leica), and the sections were mounted on copper grids ...
-
bioRxiv - Plant Biology 2020Quote: ... dehydrated in an ethanol series and embedded in LR White resin (Historesin™ Embedding Kit, Leica Instruments, Heidelberg, Germany) prior to sectioning ...
-
bioRxiv - Cell Biology 2020Quote: ... Resin blocks were cut with a diamond knife using a Leica Ultracut UCT ultramicrotome (Leica Systems, Buffalo Grove, IL). Sections were placed on 300 mesh copper TEM grids (#0300-CU ...
-
bioRxiv - Cell Biology 2021Quote: ... Freeze substitution and resin embedding were performed as described in the Results section in an automated AFS2 machine (Leica), using the FSP unit ...
-
bioRxiv - Plant Biology 2021Quote: ... Resin blocks were detached and ultrathin 70 nm-thick sections were obtained with the Ultracut UC6 ultramicrotome (Leica Microsystems), transferred to 200 mesh formvar carbon coated nickel grids (Gilder ...
-
bioRxiv - Microbiology 2021Quote: ... Thin sections of resin (80-100nm) were cut using a Reichert-Jung ultracut E Microtome (Leica Microsystems, Wetzlar, Germany) and collected on copper mesh grids (Agar Scientific ...
-
bioRxiv - Immunology 2020Quote: ... Afterwards the samples were embedded in epoxy resin (Araldite) and sectioned using a Leica Ultracut S (Leica, Wetzlar, Germany). Based on the examination of semi thin sections regions of interest of approx ...
-
bioRxiv - Cell Biology 2022Quote: ... The resin blocks were tapered into a pyramid shape and polished using a Target Sample Preparation Unit (Leica TXP) and sectioned using Leica ultramicrotome (UC7 ...
-
bioRxiv - Plant Biology 2022Quote: ... The resin-embedded samples were sectioned at 1 µm with a diamond knife using Ultracut-UCT (Leica, Wetzlar, Germany). The sections were stained with toluidine blue solution and used for microscopic analyses.
-
bioRxiv - Cell Biology 2022Quote: ... Samples were infiltrated with pure resin overnight and then embedded by using commercial flow-through chambers (Leica Microsystems, Austria) designed for sapphire discs of a diameter of 6 mm ...
-
bioRxiv - Cell Biology 2023Quote: ... Automatic freeze substitution (AFS) and resin embedding were performed in an EM-AFS2 mounted with EM-FSP (Leica Microsystems). HPF-fixed SGs were placed in 0.1% uranyl acetate in dry acetone at –90°C for 45h before the temperature was increased gradually ...
-
bioRxiv - Microbiology 2024Quote: ... Fixed pellets were rinsed and dehydrated before embedding with Spurr’s resin and cross sectioned with an ultramicrotome (Riechert Ultracut R; Leica). Ultra-thin sections were placed on formvar coated slot grids and stained with uranyl acetate and Reynolds lead citrate ...
-
bioRxiv - Microbiology 2024Quote: ... Fixed pellets were rinsed and dehydrated before embedding with Spurr’s resin and cross sectioned with an ultramicrotome (Riechert Ultracut R; Leica). Ultra-thin sections were placed on formvar coated slot grids and stained with uranyl acetate and Reynolds lead citrate ...
-
bioRxiv - Microbiology 2024Quote: ... From the resin blocks 50 nm thick ultrathin sections were cut using an Ultracut UCT ultramicrotome (Leica; Wetzlar, Germany) and were mounted on a single-hole ...
-
bioRxiv - Neuroscience 2024Quote: ... Trapezoid blocks containing the aSyn pathologies were removed from the resin-embedded section using laser capture microdissection (Leica LMD7) and the resulting blocks glued on the surface of a resin stub ...
-
bioRxiv - Plant Biology 2024Quote: ... The resulting resin blocks were then sectioned into 4 μm slices using a Leica Histocore AUTOCUT rotary microtome (Leica) and stained with either 0.01% (w/v ...
-
bioRxiv - Physiology 2020Quote: ... one quadrant/eye of the anterior segment was fixed in 2% glutaraldehyde and embedded in Epon resin and 65 nm sagittal thin sections were cut through iridocorneal tissues using an ultramicrotome (LEICA EM UC6, Leica Mikrosysteme GmbH ...
-
bioRxiv - Physiology 2020Quote: ... one quadrant/eye of the anterior segment was fixed in 2% glutaraldehyde and embedded in Epon resin and 65 nm sagittal thin sections were cut through iridocorneal tissues using an ultramicrotome (LEICA EM UC6 ...
-
bioRxiv - Developmental Biology 2021Quote: ... Stained embryos were embedded in Technovit 7100 resin (Kulzer Technique) and 5 µm sections were obtained using an RM2245 microtome (Leica). Sections were counterstained with Mayer’s hematoxylin solution and images were captured by BX61 microscope (Olympus ...
-
bioRxiv - Systems Biology 2021Quote: Specimen carriers in Epon blocks were exposed by removing excess resin using a specimen trimming device (EM TRIM2; Leica Microsystems), followed by hand trimming with a razor blade to allow complete exposure ...
-
bioRxiv - Plant Biology 2021Quote: ... 1 μm thick sections were cut with a glass knife from each resin-embedded tissue block on an ultramicrotome (Leica EM UC6 ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... The polymerized resins were ultra-thin-sectioned at 70 nm with a diamond knife using an ultramicrotome (Ultracut UCT; Leica) and the sections were mounted on copper grids ...
-
bioRxiv - Pathology 2022Quote: ... Samples were embedded in the Embed-812 resin mixture and sectioned on an ultramicrotome (LKB Ultratome V; Leica, Paris, France) using a glass knife ...
-
bioRxiv - Plant Biology 2022Quote: ... dehydrated and infiltrated with resin at cold temperature using the Leica AFS2 freeze substitution machine (Leica Mikrosysteme GmbH, Vienna, Austria) with the following protocol ...
-
bioRxiv - Biophysics 2024Quote: ... Thin sections (300 nm) were cut from the polymerized resin block using a FC7/UC7 ultramicrotome (Leica Microsystems, Vienna, Austria) and placed on carbon-coated mesh grids ...
-
bioRxiv - Cell Biology 2023Quote: ... ultrathin sections (70-75 nm) from the cured resin blocks were cut with an Ultracut E microtome (Leica Microsystems, Germany) or an UC7 microtome (Leica Microsystems ...
-
bioRxiv - Pathology 2023Quote: ... semi-thin sections measuring 1 µm were meticulously sliced from the resin blocks employing a Reichert Ultracut S microtome (Leica Microsystems Inc. ...
-
bioRxiv - Physiology 2023Quote: ... mouse anterior quadrants were embedded in Epon resin and 65 nm sagittal ultrathin sections were cut through iridocorneal angle tissues using an ultramicrotome (LEICA EM UC6 ...
-
bioRxiv - Physiology 2023Quote: ... mouse anterior quadrants were embedded in Epon resin and 65 nm sagittal ultrathin sections were cut through iridocorneal angle tissues using an ultramicrotome (LEICA EM UC6, Leica Mikrosysteme GmbH ...
-
bioRxiv - Neuroscience 2024Quote: Selected regions were re-mounted on resin stubs and 70 nm-thick sections were cut on an ultramicrotome (Leica UCT). Sections were post-stained with uranyl acetate and lead citrate according to standard protocols ...
-
bioRxiv - Cell Biology 2020Quote: ... Automated freeze-substitution in 0.1% uranyl acetate in acetone over a 72 h period and embedding in Lowicryl HM20 resin were performed using an EM AFS2 (Leica Microsystems) as previously described (Kukulski et al. ...
-
bioRxiv - Microbiology 2020Quote: ... the pellets were embedded in epoxy resin (Araldite) and ultrathin sectioned (70 nm) using a Leica Ultracut S (Leica, Wetzlar, Germany). Finally ...
-
bioRxiv - Biophysics 2020Quote: ... These cell suspensions were then frozen at high pressure (BalTec) and embedded in HM20 Resin (Electron Microscopy Services) after freeze substitution (Leica AFS) in acetone along with 2% Uranyl acetate (Electron Microscopy Services) ...
-
bioRxiv - Cell Biology 2022Quote: ... The embedded resin was cut into < 70 nm slices for transmission electron microscopy using a Leica UC6 cryo ultra microtome (Leica Microsystems). Samples were imaged on a FEI Tecnai 12 120 kV BioTwin Spirit transmission electron microscope (FEI Company).
-
bioRxiv - Neuroscience 2021Quote: ... they were contrasted with osmium tetraoxide and embedded in epoxy resin (Serva) and 0.5 µm semi-thin sections were cut (Leica RM 2155) using a diamond knife (Histo HI 4317 ...
-
bioRxiv - Physiology 2021Quote: ... Gel-embedded platelets were stained with uranyl acetate and lead aspartate followed by dehydration with ethanol and infiltrated with Epon resin in a Tissue Processor (Leica EMTP). 70nm sections were cut from blocks with a Reichert Ultracut E and imaged with a Tecnai 12 electron microscope (ThermoFisher UK).
-
bioRxiv - Genetics 2024Quote: ... embedded in Spurr resin and ultrathin sections (60 nm-thick) were collected with a Leica Ultracut S (Leica Microsystems, Waltzer, Germany). Sections were stained with 2% uranyl acetate and 4% lead citrate and examined on a Phillips BioTwin CM120 electron microscope equipped with Gatan Orius and Olympus Morada digital cameras.
-
bioRxiv - Cell Biology 2023Quote: ... Organoids were embedded in TAAB812 resin (TAAB Laboratory Equipment Ltd) and sectioned to approximately 70nm thick using a Leica UC7 Ultramicrotome (Leica Microsystems). Sections were collected onto copper mesh grids and contrasted for 2min with 4% uranyl acetate solution in methanol (VWR) ...
-
bioRxiv - Neuroscience 2023Quote: ... a section containing the region of interest was excised and glued to a Durcupan resin block for ultrathin sectioning (Ultracut UC7 ultramicrotome, Leica Biosystems). Ultrathin sections ...