Labshake search
Citations for Leica :
751 - 800 of 1722 citations for Anti human IgE Conjugated to 40 nm Gold since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
Amphetamine reduces utility encoding and stabilizes neural dynamics in rat anterior cingulate cortexbioRxiv - Neuroscience 2020Quote: ... the brains were coronally sectioned at 40 μm thickness using a CM3050 S freezing Cryostat (Leica, Germany) and mounted on glass microscope slides ...
-
bioRxiv - Cancer Biology 2021Quote: ... Whole slide scanning (×40 objective) was performed on an Aperio AT2 digital whole slide scanner (Leica Biosystems). Human acral melanoma TMA stains for CRKL ...
-
bioRxiv - Neuroscience 2022Quote: ... Coronal sections were cut at a thickness of 40 μm using a sliding microtome (Microm HM430, Leica), collected ...
-
bioRxiv - Neuroscience 2022Quote: ... The forebrain was then sectioned in 40 µm thick coronal slices with a cryostat (Leica Microsystems CM3050S). Sections were mounted with 1:2500 DAPI in Fluoromount G (Southern Biotech ...
-
bioRxiv - Neuroscience 2022Quote: ... Brains were sectioned to a thickness of 40 μm using a sliding freezing microtome (Leica SM2010 R) and preserved in cryoprotectant solution (25% glycerol and 30% ethylene glycol in PBS) ...
-
bioRxiv - Neuroscience 2022Quote: ... we cut the brains into 40 μm coronal sections with a Leica VT-1200S vibratome (Leica Biosystems), stored in cryoprotectant as free-floating sections (−20°C ...
-
bioRxiv - Neuroscience 2022Quote: ... Coronal brain sections and transverse spinal cord sections (30–40 μm) were cryosectioned on a cryostat (Leica). Spinal cord sections were collected on glass slides (12-550-15 ...
-
bioRxiv - Neuroscience 2024Quote: ... Videos were recorded for 40 s (1 frame/s) multiphoton confocal microscope TCS SP8 MP-OPO (Leica) equipped with 20x/0.75 multi immersion objective in OTC imaging medium ...
-
bioRxiv - Neuroscience 2024Quote: ... Coronal sections of 40 µm were obtained at optimal cutting temperature using a cryostat (Leica Microsystems VT100). Brain sections were blocked in 10% normal goat serum (NGS ...
-
bioRxiv - Neuroscience 2024Quote: ... Blocks were then frozen on dry ice before cutting 40 μm sections on a cryostat (Leica CM1950) at −19°C ...
-
bioRxiv - Plant Biology 2024Quote: Imaging was performed using a 40× oil immersion lens using a Leica SP5 confocal microscope (Leica Microsystems). An Argon laser (488 nm ...
-
bioRxiv - Cell Biology 2023Quote: ... 20 and 40-mm-thick sagittal sections were obtained with a freezing-sliding cryostat (Leica; CM1950 AgProtect).
-
bioRxiv - Neuroscience 2023Quote: ... brains were cut coronally in 40 µm-thick sections with a vibratome (VT1000S; Leica Microsystems, Wetzlar, Germany).
-
bioRxiv - Cell Biology 2022Quote: ... 15 minutes of Protease III (ACD) at 40°C using the Bond RX auto-stainer (Leica Biosystems), and 1:750 dilution of TSA-Cyanine 5 Plus (AKOYA ...
-
bioRxiv - Cell Biology 2023Quote: ... We used a 20-fold or 40-fold glycerol immersion objective (ACS APO Leica Microsystem, Wetzlar, Germany) and obtained stacks of 2 μm and 1,048,576 pixels.
-
bioRxiv - Neuroscience 2023Quote: ... 40 um coronal sections were collected serially (rostral to caudal) using a freezing microtome (Leica; SM 2000R) and stored in PBS containing 0.2% Sodium azide.
-
bioRxiv - Neuroscience 2023Quote: ... 40-μm coronal sections were then prepared from the fixed brains using a vibratome (Leica VT1000 S). Free-floating sections were then mounted to microscope slides ...
-
bioRxiv - Neuroscience 2023Quote: Brain tissue was cryo-sectioned into 40 μm thick sections on a sliding microtome (SM 2010R, Leica) connected to a freezing unit (Microm KS 34 ...
-
bioRxiv - Plant Biology 2024Quote: ... Transverse sections (40-50 µm-thick) were prepared with a vibratome (Leica VT1000S, Leica Biosystems, Nussloch, Germany) and stained with safranin-alcian blue (Urbancsok et al. ...
-
bioRxiv - Neuroscience 2024Quote: ... Brain serial coronal sections (40 µm thick) were collected using a vibrating blade microtome (Leica VT1200/VT1200S). For immunofluorescence (IF) ...
-
bioRxiv - Neuroscience 2024Quote: ... Images were acquired with a Leica DM750 brightfield microscope with a 40×/0.4 numerical aperture objective (Leica) for cells or with an EVOS M7000 Imaging System with a 20×/0.4 numerical aperture (Thermo Fisher Scientific ...
-
bioRxiv - Neuroscience 2024Quote: ... Transverse sections of 40 μm thickness were obtained from liver tissue using a vibratome (Leica Model VT1000S). The sections were stored in antigel (40% Phosphate Bufer Saline (PBS) ...
-
bioRxiv - Neuroscience 2024Quote: ... Brains were sectioned in 40 µm coronal sections using a cryostat (CM3050S; Leica Microsystem GmbH, Nussloch, Germany), mounted on slides and Nissl stained to visualise the brain structures and to identify the implantation sites ...
-
bioRxiv - Cancer Biology 2024Quote: ... DAB and IF-stained slides were scanned up to original magnification ×40 on Scanscope CS2 (Aperio, Leica) and Opera Phenix High-Content Imaging System (PerkinElmer ...
-
bioRxiv - Bioengineering 2021Quote: ... Hyvolution images were taken using Leica SP8 confocal microscope under the Hyvolution mode with 0.6 AU pinhole and deconvolved using prolong gold as mounting media in LAS X (Leica). Images were exported as tiff format and analyzed in Fiji ...
-
bioRxiv - Cell Biology 2021Quote: ... The ribbon was attached to the gold pre-coated EM grid by charging with a Crion device (Leica Microsystems) in charge mode for 1 minute ...
-
bioRxiv - Neuroscience 2023Quote: ... Tissue blocks were gold palladium coated using a sputter coater and scanned with a scanning electron microscope (S4800, Leica).
-
bioRxiv - Cell Biology 2024Quote: ... The harvested cells were immediately transferred to aluminum- or gold-coated (Type A) specimen carriers (Leica Microsystems Inc., Austria) for high-pressure freezing.
-
bioRxiv - Neuroscience 2021Quote: Sections (70 nm) were cut from polymerized PAG samples using an ultramicrotome (Leica UC7). Sections were imaged without post-staining using a Philips CM120 Biotwin operated with an acceleration voltage of 100kV.
-
bioRxiv - Cell Biology 2022Quote: 50 nm sections were cut using a diamond knife on an ultramicrotome (Leica UC7) and collected on single slot copper grids with a formvar support film ...
-
bioRxiv - Plant Biology 2021Quote: ... The detection window was set to 525 to 600 nm for YFP (Leica Microsystems). Seven-to nine-day-old seedings were stained with 1x propidium iodide and imaged at 40X magnification ...
-
bioRxiv - Immunology 2021Quote: Semi-thin sections were cut at 450 nm using an UC7 ultramicrotome (Leica Microsystems) and collected onto formvar-coated 200-line bar grids + 1C/bar (Science Services ...
-
bioRxiv - Cell Biology 2021Quote: ... 60-nm ultrathin sections were generated using an ultramicrotome (Leica-UC6 ultramicrotome, Vienna, Austria). For immunogold labelling of ultrathin cryosections ...
-
bioRxiv - Cell Biology 2021Quote: ... The polymerized samples were sectioned (60 nm) with an ultramicrotome (UC7; Leica Microsystems, Germany), and the sections were mounted on copper slot grids with a specimen support film ...
-
bioRxiv - Cell Biology 2021Quote: ... The polymerized samples were sectioned (60 nm) with an ultramicrotome (UC7; Leica Microsystems, Germany), and the sections were mounted on copper slot grids with a specimen support film ...
-
bioRxiv - Cell Biology 2021Quote: ... Ultrathin sections of 80 nm were cut on an ultramicrotome (Leica Microsystems, EM UC7) and collected on a formvar and carbon-coated copper slot grid (LFG ...
-
bioRxiv - Neuroscience 2020Quote: ... Ultrathin sections (70 nm) were sliced using a microtome (EM UC7 Ultramicrotome, Leica Microsystems) and mounted on formvar coated copper slot grids ...
-
bioRxiv - Cell Biology 2021Quote: ... and ultrathin (80 nm thick) sections were cut using an ultramicrotome (Leica Ultracut UTC6). Samples were imaged under the HT-7800 120kv transmission electron microscope.
-
bioRxiv - Cell Biology 2022Quote: ... Ultrathin sections (80 nm) were prepared using an EM UC7 Ultracut ultramicrotome (Leica, UC7). Sections were observed and photographed using a transmission electron microscope (Hitachi H-7650 ...
-
bioRxiv - Microbiology 2022Quote: ... 60 to 80 nm sections were obtained using an ultra-microtome UC7 (Leica Microsystems) and an Ultra 35° diamond knife (DiATOME ...
-
bioRxiv - Neuroscience 2021Quote: ... Ultrathin sections (100 nm in thickness) were prepared with an ultramicrotome (Leica, Wien, Austria), and photographs were taken with an H7100 electron microscope (Hitachi ...
-
bioRxiv - Neuroscience 2021Quote: ... the block was sputter coated with 20 nm of platinum (ACE600 Leica Microsystems, Vienna) before imaging at the Zeiss Merlin VP Compact SEM equipped with a Gatan 3View2XP system ...
-
bioRxiv - Immunology 2021Quote: ... Ultrathin sections of 70 nm were prepared on a Leica Ultracut S (Leica Biosystems). Sections were stained with 4 % uranyl acetate (Serva ...
-
bioRxiv - Microbiology 2020Quote: ... Semi-thick (300-400 nm) sections were cut with a UC6 ultramicrotome (Leica Microsystems) using a diamond knife (Diatome ...
-
bioRxiv - Plant Biology 2021Quote: ... Ultrathin sections (90 nm) were performed on a UC7 Leica Ultra microtome (Leica, Netherlands). Sections on nickel grids were incubated with saturated sodium metaperiodate for 3 min ...
-
bioRxiv - Microbiology 2020Quote: ... 70 nm ultrathin sections were generated using a Leica EM UC7 ultramicrotome (Leica Microsystems) and attached to 100-mesh Cu formvar-carbon coated grids ...
-
bioRxiv - Neuroscience 2022Quote: ... Ultrathin ultramicrotome sections (70–80 nm thick: Leica EM UC6 Leica Microsystems, Wetzlar, Germany) were routinely stained with uranyl acetate and lead citrate ...
-
bioRxiv - Biophysics 2022Quote: ... the samples were coated with around 1 nm of either tungsten (ACE 200, LEICA). SEM imaging was performed using a GeminiSEM 500 microscope from Zeiss ...
-
bioRxiv - Cell Biology 2020Quote: ... Serial ultrathin sections (70-80 nm) were cut using an UC7 ultramicrotome (Leica Microsystems) and collected onto formvar-coated copper slot grids ...
-
bioRxiv - Microbiology 2021Quote: ... Ultrathin sections (80-70 nm) were obtained with an ultramicrotome EM UC6 (Leica Microsystems) and collected on formvar carbon-coated copper grids (Agar) ...