Labshake search
Citations for Drummond Scientific :
51 - 100 of 123 citations for 5 Isobutylcyclohexane 1 3 dione 98% since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... and a beveled glass pipette (Wiretrol II, 5-000-2010, Drummond Scientific Company) back-filled with mineral oil and front-filled with the material to be injected was slowly inserted into a target coordinate ...
-
bioRxiv - Neuroscience 2021Quote: ... was delivered using a glass pipette pulled from borosilicate glass (3.5” 3-000-203-G/X, Drummond Scientific) and connected to a Nanoject III system (Drummond Scientific) ...
-
bioRxiv - Neuroscience 2019Quote: ... Viruses were front-filled into a pulled glass pipette (Drummond Scientific, #5-000-2005) filled with mineral oil (Millipore Sigma ...
-
bioRxiv - Genetics 2021Quote: ... Each fly was injected with 50 nl of 3 mM paraquat ringer solution using a NANOJECT II (Drummond Scientific). Control flies were injected with ringer buffer ...
-
bioRxiv - Neuroscience 2020Quote: ... using a pulled glass pipette (5 μl PCR Pipets, Drummond Scientific Co, Broomall, PA, USA) attached to a Hamilton microliter syringe (Hamilton Bonaduz AG ...
-
bioRxiv - Neuroscience 2020Quote: ... and a glass pipette (Wiretrol II #5-000-2005, Drummond Scientific Company, Broomall, PA, USA), pulled to have an outer diameter of 60-90μm at the tip ...
-
bioRxiv - Neuroscience 2021Quote: ... The glass pipettes (1.14 mm outer diameter and 0.53 mm inner diameter, 3-000-203-G/X, Drummond Scientific, PA) were pulled on a P-97 Flaming/Brown type micropipette puller (Sutter Instrument ...
-
bioRxiv - Physiology 2021Quote: ... The oocytes were pressure-injected using a Nanoject variable microinjection apparatus (model mo. 3-000-203, Drummond Scientific, Broomal, PA) with 0.05 – 500 ng/μl of connexin cRNA along with 5 ng/36.8 nl of oligonucleotide antisense to mRNA for Xenopus Cx38 to prevent contamination by endogenous connexin hemichannel currents [25] ...
-
bioRxiv - Neuroscience 2022Quote: ... Ten or twenty nL of undiluted viral solution were delivered using a glass pipette pulled from borosilicate glass (3.5” 3-000-203-G/X, Drummond Scientific) and connected to a Nanoject III system (Drummond Scientific) ...
-
bioRxiv - Neuroscience 2023Quote: ... A recombinant viral vector was delivered using a glass pipette pulled from borosilicate glass (3.5” 3-000-203-G/X, Drummond Scientific) and connected to a Nanoject III system (Drummond Scientific) ...
-
bioRxiv - Developmental Biology 2021Quote: ... glass needles were created by pulling Wiretrol II capillaries (Drummond Scientific Company, cat. #5-000-2005) using a needle puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2021Quote: ... was microinjected through micropipettes with ~10-μm Ø pulled from thinwalled borosilicate glass capillaries (outer Ø: 1.14 mm, inner Ø: 0.53 mm; 3-000-203-G/X, Drummond Scientific) using a vertical micropipette puller (PE-2 ...
-
bioRxiv - Neuroscience 2022Quote: ... of CAV-2-Cre using pipettes with long taper tips pulled from borosilicate capillaries (3.5” Drummond # 3-000-203-G/X, Drummond Scientific, PA). For two-photon imaging experiments ...
-
bioRxiv - Neuroscience 2023Quote: ... was injected into two coordinates in the target brain region at a speed of 60 nl/min using Nanoject 3 pump (Drummond Scientific). The following coordinates were used [Distance in millimeters from the Bregma for the anterior (A)-posterior (P ...
-
bioRxiv - Microbiology 2023Quote: ... re-suspended in water was injected into the thorax of cold-anesthetized 3-4 day old female mosquitoes using a Nanoject III (Drummond Scientific).
-
bioRxiv - Neuroscience 2024Quote: The AAV vectors were injected through a pulled-glass pipette and the nanoliter injector (Nanoject III, Drummond Scientific −3-000-207). The injection was performed using a small-animal stereotaxic instrument (David Kopf Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... dorsal-ventral (D/V): 2] using a glass micropipette (Drummond Scientific Company, Wiretrol I, 5-000-1050) was performed ...
-
bioRxiv - Neuroscience 2020Quote: ... Virus was introduced through a small craniotomy (from bregma: x=−3, y=−0.9, z=−0.5 mm) using a Nanoject II (Drummond Scientific Company; Broomall, PA) in isoflurane anesthetized mice at P15-17 ...
-
bioRxiv - Neuroscience 2020Quote: ... was injected in the proximity of the site of injury by electrical micro-injector (BJ110, BEX CO., LTD.) through glass capillaries (3-000-203-G/X, Drummond Scientific Company). Following injection ...
-
bioRxiv - Bioengineering 2022Quote: ... After the dura was removed the flexiLiTE optoelectrode was inserted into the brain (1.2 mm depth from the surface of the brain) using a glass pipette with a tip diameter of 15-20 μm (3-000-203-G/X, Drummond Scientific, PA). The glass pipette was retracted ...
-
bioRxiv - Cell Biology 2023Quote: ... 10 ∼ 0.8-1cm long planarians were injected 3 consecutive days with 20-50 ng dsRNA per injection using a Nanoject II injector (Drummond Scientific, Broomall, PA). The animals were then amputated from their head and tail at day 4 ...
-
bioRxiv - Neuroscience 2020Quote: ... Concentrated cell suspensions were loaded into beveled glass micropipettes (≈70-90 μm diameter, Wiretrol 5 μl, Drummond Scientific Company) prefilled with mineral oil and mounted on a microinjector ...
-
bioRxiv - Genetics 2019Quote: ... Cold-anesthetized 5-6 day-old females were injected into their thorax using a nanoinjector (Nanoject II, Drummond Scientific) with 69 nL of bacteria or 138 nL of fluorescent beads ...
-
bioRxiv - Neuroscience 2021Quote: ... The tracer was delivered using a pulled glass pipette (tip diameter = 40– 60 μm) at a rate of 50 nl min with a Nanojet 3 (Drummond Scientific Company, Broomall, PA). The pipette was left in the brain for 15 min after completion of the injection to prevent backflow ...
-
bioRxiv - Neuroscience 2023Quote: ... This concentrated cell suspension was loaded into beveled glass micropipettes (~60-100 μm diameter, Wiretrol 5 μL, Drummond Scientific Company) prefilled with mineral oil and mounted on a microinjector as previously described (Wichterle et al. ...
-
bioRxiv - Developmental Biology 2020Quote: ... loaded into a fine glass needle and implanted into the abdomen of female host w1118 flies using a nanoinjector (Nanoject II Auto-Nanoliter Injector, Drummond Scientific Company, 3-000-205A). Host flies carrying allografts were kept at 25°C and examined daily for the presence of GFP in their abdomen and other tissues ...
-
bioRxiv - Neuroscience 2021Quote: ... into each side of the midline guided by ultrasound backscatter microscopy (VisualSonics, Vevo 3100) via a pulled glass micropipette (Drummond Scientific, 3-000-203-G/X) with a digitally-controlled ...
-
bioRxiv - Biochemistry 2022Quote: Sexually mature females (3 or 4 days old) were anaesthetized (Inject+matic sleeper TAS, Geneva, Switzerland) and injected (Nanoject II, Drummond Scientific/Olinto Martelli Srl, Florence, Italy) with 0.69μg (2x 69nL x 5μg/μL ...
-
bioRxiv - Neuroscience 2020Quote: ... AAV viruses containing double floxed ChR2 construct (5 nl) were microinjected to the septal tissue with a micro injector (Drummond Scientific) on the second day of culturing ...
-
bioRxiv - Neuroscience 2024Quote: Concentrated GFP+ MGE cells (∼600 cells per nl) were injected using 30° beveled glass micropipettes (80 μm diameter tip, Witerol 5 μl, Drummond Scientific) prefilled with mineral oil into cortex or hippocampus of recipient pup (P2-4) ...
-
bioRxiv - Neuroscience 2024Quote: ... Zürich) at an injection rate of 50-100 nL/min using a thin glass pipette (5-000-1001-X, Drummond Scientific) pulled on a vertical puller (Narishige PP-830) ...
-
bioRxiv - Immunology 2019Quote: ... was injected into the thorax or abdomen of anesthetized females aged 5-7 days using a Nanoject II injector (Drummond Scientific Inc.) fitted with a pulled glass capillary ...
-
bioRxiv - Neuroscience 2022Quote: ... Injections (0.75 ul/hemisphere) were performed over a period of 5 minutes (0.15 ul/minute) using a Nanoject II (Drummond Scientific, Broomall, PA) and injectors were left in place for 5 minutes to facilitate viral diffusion from the injection site ...
-
bioRxiv - Molecular Biology 2022Quote: ... Oocytes were injected with 50 nL (12.5 ng of each injected gene) of the desired cRNA subunit and accessory protein combination mix with the NanojectII (Drummond Scientific, USA). Following injection ...
-
bioRxiv - Neuroscience 2024Quote: ... Virus was injected bilaterally in the DMS or DLS at 4.6 nL/5 seconds (9 minutes) using a borosilicate pipette (Drummond scientific, >25 µm) coupled to a nanoinjector (Nanoject II Drummond Scientific) ...
-
bioRxiv - Neuroscience 2023Quote: ... The viral construct AAV5-DIO-CaMKIIa-hChR2(H134R)-eYFP (Neurophotonics, 5.0x1012 GC/ml) was microinfused using a Nanoject II injector and glass micropipette (Drummond Scientific, 3-000-203-G/X, 10 μm tip) in the ventral tegmental area (10° angle ...
-
bioRxiv - Neuroscience 2022Quote: ... The skull was gently drilled and 10 nL of a viral solution were injected (Nanoject III, Drummond Scientific, rate of 5 nL/min) at a depth of 1.25 mm below the dura.
-
bioRxiv - Neuroscience 2024Quote: ... Mice were head-fixed on a platform and the B2 whisker was inserted inside a glass capillary tube (Wiretrol® II 5 & 10 uL, Drummond Scientific Company) placed 2mm away from the mouse’s snout ...
-
bioRxiv - Microbiology 2023Quote: ... 1-μl capillaries (Microcaps, Drummond Scientific) were heat-sealed at one end and filled with buffer (control ...
-
bioRxiv - Neuroscience 2022Quote: ... Ten nL of undiluted viral solution were injected using an oil-based pressure injection system (Nanoject III, Drummond Scientific, rate of 5 nL/min). The tip of the pipette was broken to achieve an opening with an internal diameter of 30-40 μm ...
-
bioRxiv - Neuroscience 2021Quote: ... 0.6 mm rostral to bregma and 0.6 mm from the cortical surface) via pulled glass pipettes (5 μl, Drummond Scientific; 10-20 nl/min) using an automated injection system (Model Picospritzer iii ...
-
bioRxiv - Neuroscience 2019Quote: ... Pseudo-stereotaxic injection (from lambda ML: −1,2, A/P:2, D/V: 2,5-2) using glass micropipette (Drummond scientific company, wiretol I 50μL, 5-000-1050) was performed and 2μL of plasmid (betweeen 5 and 8 μg/μL ...
-
bioRxiv - Neuroscience 2022Quote: ... VVF ETH Zurich) 1:1 in sterile saline and loaded it into a Nanoject II or Nanoject III injector (Drummond Scientific). After induction of anesthesia as described above ...
-
bioRxiv - Molecular Biology 2020Quote: ... Oocytes were injected with 27-54 ng of total mRNA for α, β and γ subunits in a 1:1:10 ratio (Boileau et al., 2002) (Nanoject, Drummond Scientific). Oocytes were incubated in ND96 (in mM ...
-
bioRxiv - Biophysics 2023Quote: ... Oocytes were injected with 27–54 ng of total mRNA for α, β, and γ subunits (or mutants) in a 1:1:10 ratio (Boileau et al., 2002) (Nanoject, Drummond Scientific). Oocytes were incubated in ND96 (in mM ...
-
bioRxiv - Developmental Biology 2020Quote: ... diluted 1:100 in PBS using a Nanoject injector (Drummond Scientific). After injection ...
-
bioRxiv - Neuroscience 2022Quote: ... through a glass pipette (PCR Micropipets 1 – 10 ml, Drummond Scientific Company, USA) with a 21 – 27 µm inner tip diameter ...
-
bioRxiv - Neuroscience 2022Quote: ... Injections were done at 1 nL/s with a Nanoject III (Drummond Scientific Company).
-
The Indirect Pathway of the Basal Ganglia Promotes Negative Reinforcement, But Not Motor SuppressionbioRxiv - Neuroscience 2022Quote: ... Virus (Striatum: 0.5-1 μl, GPe: 150 nL) was injected with a Nanoject (Drummond Scientific) through a pulled glass pipet (tip diameter ∼30 μm ...
-
bioRxiv - Neuroscience 2021Quote: ... Viruses were delivered at a rate of 1-2 nl/s using Nanoject III (Drummond Scientific, USA).