Labshake search
Citations for Drummond Scientific :
1 - 50 of 100 citations for 4 Amino 3 8 dichloro 5 methoxyquinoline since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2021Quote: Phagocytosis assays were performed by injecting 69 nl of 2% green fluorescent FluoSpheres (vol/vol) in 1X PBS to naïve female mosquitoes (3-to 5-day old) using a Nanoject II injector (Drummond Scientific). After injection ...
-
bioRxiv - Microbiology 2023Quote: ... re-suspended in water was injected into the thorax of cold-anesthetized 3-4 day old female mosquitoes using a Nanoject III (Drummond Scientific).
-
bioRxiv - Neuroscience 2023Quote: ... DV: -4.5 mm from brain surface) using either a Hamilton syringe (5 µL) or Nanoject (Drummond Scientific; Part number: 3-000-207).
-
bioRxiv - Neuroscience 2020Quote: ... filled with an AAV vector without dilution (qPCR titer: 3–5×10^12 vg/ml) was installed with an auto-nanoliter injector (Nanoject II; Drummond Scientific, Broomall, PA, USA) and the injector was 9.5 degree leftward tilled from the sagittal plane to avoid the sagittal sinus ...
-
bioRxiv - Biochemistry 2022Quote: Sexually mature females (3 or 4 days old) were anaesthetized (Inject+matic sleeper TAS, Geneva, Switzerland) and injected (Nanoject II, Drummond Scientific/Olinto Martelli Srl, Florence, Italy) with 0.69μg (2x 69nL x 5μg/μL ...
-
bioRxiv - Neuroscience 2023Quote: ... Nanoject III (Drummond Scientific, Item# 3-000-207) was used for AuCx ...
-
bioRxiv - Neuroscience 2023Quote: ... A Nanoinject III (Drummond Scientific, 3-000-207) was used to deliver either 250-300 nL of the retrograde tracer Fast DiI oil (2.5 mg/mL ...
-
bioRxiv - Neuroscience 2021Quote: ... and mounted in a NanoJect 3 (Drummond Scientific, USA). The pipette was front loaded with the virus solution and 150 nL injected at a depth of 350-500 μm below the dura ...
-
bioRxiv - Neuroscience 2022Quote: ... using a Nanoject 3 system (Drummond Scientific Company, PA) (500 nl ...
-
bioRxiv - Neuroscience 2019Quote: ... A glass pipette (3-000-203-G/X, Drummond Scientific) was pulled to a fine tip (P-97 Flaming/Brown Micropipette Puller ...
-
bioRxiv - Neuroscience 2020Quote: ... A glass pipette (3-000-203-G/X, Drummond Scientific) was pulled to a fine tip (P-97 Flaming/Brown Micropipette Puller ...
-
bioRxiv - Neuroscience 2022Quote: ... and glass capillaries (3-000-203-G/X, Drummond Scientific) backfilled with mineral oil ...
-
bioRxiv - Neuroscience 2023Quote: ... A glass pipette (3-000-203-G/X, Drummond Scientific) was pulled to a fine tip (P-97 Flaming/Brown Micropipette Puller ...
-
bioRxiv - Cancer Biology 2024Quote: Nanoject III Injector (Drummond Scientific Company; CA#3-000-207)
-
bioRxiv - Neuroscience 2023Quote: ... Viral vectors were delivered using Nanoject 3 (Drummond Scientific, Broomall, PA). The needle was held in place for >5 min after infusion at each DV ...
-
bioRxiv - Neuroscience 2021Quote: ... glass micropipettes (Drummond Scientific, 5-000-1001-X10), as previously described (Mohan et al. ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... Borosilicate glass 3.5” capillaries (Drummond Scientific Co. 3-000-203-G/X) were pulled to form thin needles in a needle puller (Narishige PC-10) ...
-
bioRxiv - Neuroscience 2020Quote: ... The glass pipette (#3-000-203-G/X; Drummond Scientific, Broomall, PA) with a beveled tip (diameter = 45 μm ...
-
bioRxiv - Neuroscience 2021Quote: ... The glass pipette (Drummond Scientific #3-000-203-G/X; Broomall, PA) with a beveled tip (diameter = 45 μm ...
-
bioRxiv - Immunology 2022Quote: Borosilicate glass 3.5” capillaries (Drummond Scientific Co. 3-000-203-G/X) were pulled to form thin needles in a needle puller (Narishige PC-10) ...
-
bioRxiv - Neuroscience 2022Quote: ... was injected with Nanoject-III (Drummond Scientific Company, model #3-000-207) at a depth of 200 μm beneath pia surface and virus was slowly injected at 4-5 sites ~1 to 4 mm lateral to midline of skull ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass capillary used for injections (catalog # 3-000-203-G/X, Drummond Scientific) were pulled with a P-1000 microelectrode puller (Sutter Instrument) ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: ... a glass pipette (3-000-203-G/X, Drummond Scientific Company, PA, USA) was pulled ...
-
bioRxiv - Neuroscience 2023Quote: ... connected to a glass pipette (Drummond Scientific, 5-000-2005) pulled to a 30 µm tip (Sutter Instrument ...
-
bioRxiv - Neuroscience 2023Quote: ... A Wiretrol II glass pipette (Drummond Scientific Company, 5-0002010), pulled to give a sharp tip (Sutter ...
-
bioRxiv - Neuroscience 2023Quote: ... and pulled glass electrodes (Drummond Scientific Company, 5-000-2005). 400 nl of virus was injected at a rate of 40 nl/min ...
-
bioRxiv - Neuroscience 2023Quote: Glass pipettes (Wiretrol II, Drummond Scientific Company, 5-000-2010) with a long taper (more than 6 mm ...
-
bioRxiv - Bioengineering 2023Quote: Glass pipettes (5-000-1010, DRUMMOND WIRETROL, Drummond Scientific Co.) were pulled on a Model P-97 (Sutter Instrument Co.) ...
-
bioRxiv - Neuroscience 2020Quote: ... and adeno-associated virus (AAV) particles were injected with a Nanoject 3 (Drummond scientific) at a speed of 1 nl/sec for 30 secs injection with 30 secs pause for a total 33 cycles (i.e. ...
-
bioRxiv - Neuroscience 2019Quote: ... using a pressure injection system (Nanoject II, Drummond Scientific Company, Catalog# 3-000-204). To mark the injection site ...
-
bioRxiv - Neuroscience 2023Quote: ... a glass capillary tube (model #3-000-203-G, Drummond Scientific Company, Broomall PA) was backfilled with mineral oil before being loaded into a Nanoject III injector (model #3-000-207 ...
-
bioRxiv - Neuroscience 2022Quote: ... A calibrated glass pipette (calibrated micropipette 1-5 µl, Drummond Scientific) filled with the appropriate virus was slowly lowered to the target depth of 2.9 mm below bregma ...
-
bioRxiv - Neuroscience 2022Quote: ... 0.53 mm inner diameter capillary glass (cat# 3-000-203-G/X, Drummond Scientific Company) with a P-1000 microelectrode puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2020Quote: ... 0.53 mm inner diameter capillary glass (cat# 3-000-203-G/X, Drummond Scientific Company) with a P-1000 microelectrode puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2024Quote: ... Injection pipettes were prepared from glass capillaries (catalog # 3-000-203-G/X, Drummond Scientific) pulled with a P-1000 microelectrode puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2024Quote: ... 5 sec delay between 10 nl injection cycles (Nanoject III, Drummond Scientific) using pulled glass pipets (Drummond Scientific) ...
-
bioRxiv - Neuroscience 2019Quote: ... we used capillary glass tubes (3.5” #3-000-203-G/X, Drummond Scientific Co, PA, USA), pulled using a P-97 pipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... Injections were performed with a glass pipette mounted in a Nanoject 3 infusion system (Drummond Scientific). 500 nL of virus AAV1-Syn-GCaMP6s AAV2/9-CAG-FLEX-GCaMP6m-WPRE.SV40 (1.37 × 1012 genome copies (GC ...
-
bioRxiv - Neuroscience 2023Quote: ... Virus was injected with needles pulled from capillary glass (3-000-203-G/X, Drummond Scientific) at a flow rate of 2nl/s using a micropump (Nanoject III ...
-
bioRxiv - Neuroscience 2023Quote: ... N=4) at 27.6 nL/min using a nanoliter injector (Nanoject II, Drummond Scientific) at 0.1 Hz ...
-
bioRxiv - Neuroscience 2019Quote: ... or a 1:1 mix of AAV9.CamKII0.4.Cre.SV40 and either AAV9.CAG.Flex.GCaMP6f.WPRE.SV40 or AAV9.CAG.Flex.GCaMP6s.WPRE.SV40 was injected using an oil-based pressure injection system (Nanoject 3, Drummond Scientific). After injections ...
-
bioRxiv - Developmental Biology 2024Quote: Animals were injected with zfp-1 dsRNA using Nanoject III (CAT 3-000-207, Drummond Scientific company). Briefly ...
-
bioRxiv - Developmental Biology 2020Quote: ... on ice and then aspirated into a micropipette (Drummond Scientific, 5-000-2010). A small incision was made near the kidney pole to separate the capsule from the renal parenchyma ...
-
bioRxiv - Neuroscience 2020Quote: ... and ITC injections (marked 1 to 5 μl, Drummond Scientific, Broomall, PA, USA) were pulled on a horizontal pipette puller (P-1000 ...
-
bioRxiv - Neuroscience 2024Quote: ... and a beveled glass pipette (Wiretrol II, 5-000-2010, Drummond Scientific Company) back-filled with mineral oil and front-filled with the material to be injected was slowly inserted into a target coordinate ...
-
bioRxiv - Neuroscience 2021Quote: ... was delivered using a glass pipette pulled from borosilicate glass (3.5” 3-000-203-G/X, Drummond Scientific) and connected to a Nanoject III system (Drummond Scientific) ...
-
bioRxiv - Neuroscience 2019Quote: ... Viruses were front-filled into a pulled glass pipette (Drummond Scientific, #5-000-2005) filled with mineral oil (Millipore Sigma ...
-
bioRxiv - Neuroscience 2022Quote: ... A small hole was drilled into the skull and 400 nL of 0.9% saline or 0.9% saline + 100 ng/μL recombinant mouse IFN-γ (40 ng IFN-γ total) was injected through a pulled glass pipet using a Nanoject 2000 (Drummond Scientific; 8 pulses of 50 nL). At 5 minutes after injection ...
-
bioRxiv - Genetics 2021Quote: ... Each fly was injected with 50 nl of 3 mM paraquat ringer solution using a NANOJECT II (Drummond Scientific). Control flies were injected with ringer buffer ...
-
bioRxiv - Neuroscience 2020Quote: ... using a pulled glass pipette (5 μl PCR Pipets, Drummond Scientific Co, Broomall, PA, USA) attached to a Hamilton microliter syringe (Hamilton Bonaduz AG ...