Citations for Drummond Scientific :
51 - 100 of 648 citations since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... A Nanoject III microinjector (Drummond Scientific, Broomall, PA, USA) was used to deliver 23 nL boluses into the ganglion on a slow speed setting (92 nL/s) ...
-
bioRxiv - Bioengineering 2024Quote: ... a microinjector (Nanoject 3, Drummond Scientific) was used to inject 1µL of 6-OHDA hydrobromide (Sigma Aldrich #162957 ...
-
bioRxiv - Cell Biology 2024Quote: ... Nanoinjection into the pericardial cavity and tail vein of embryos was performed using the Nanoject II (Drummond Scientific) and in-house produced capillary glass needles ...
-
bioRxiv - Cell Biology 2024Quote: ... attached to a Nanoject II suction system (Drummond Scientific, Broomall, PA), was used to collect a total of 30 umbrella cells ...
-
bioRxiv - Neuroscience 2024Quote: ... A Nano-Inject II (Drummond Scientific) was used to inject 23 nL virus at intervals of 10 seconds to obtain the desired volume ...
-
bioRxiv - Neuroscience 2024Quote: ... Injections were performed using Nanoject II (Drummond Scientific) with pulled glass pipettes ...
-
bioRxiv - Neuroscience 2024Quote: ... and AAV2/9-TRE-tandem-GCaMP6s (2.65×1013 vg/ml) was loaded into a glass pipette and injected using a Nanoject III (Drummond Scientific Company). The pipette was inserted 300-500 μm below the cortical surface ...
-
bioRxiv - Neuroscience 2024Quote: ... Virus injection was performed using borosilicate glass injection pipettes (Wiretrol II; Drummond Scientific) pulled to a taper length of 30 mm and a tip diameter of 50 μm ...
-
bioRxiv - Neuroscience 2024Quote: ... 800xg) and cell suspensions were loaded into beveled glass micropipettes (≈70-90 μm diameter, Wiretrol 5 μl, Drummond Scientific Company) prefilled with mineral oil and mounted on a microinjector ...
-
bioRxiv - Neuroscience 2024Quote: ... with a Nanoject II Injector (Drummond Scientific Company, Broomall, PA, USA) before the 10 min wait ...
-
bioRxiv - Neuroscience 2024Quote: ... or Amygdala region (AP: -1.6 mm, M/L: -2.9 mm, DV: 4.5mm) using the Nanojector II system from Drummond Scientific. The injection comprised 300 nL of virus diluted with 300 nL of PBS ...
-
bioRxiv - Neuroscience 2024Quote: ... and 1.6 mm ventral from the skull surface) using a Nanoject microinjector (Drummond Scientific). Next ...
-
The node of Ranvier influences the in vivo axonal transport of mitochondria and signalling endosomesbioRxiv - Neuroscience 2024Quote: ... glass micropipettes (Drummond Scientific,5-000-1001-X10) for soleus ...
-
bioRxiv - Neuroscience 2024Quote: ... with 20-40s intervals using a Nanoject III (Drummond Scientific). Following injection ...
-
bioRxiv - Biophysics 2024Quote: ... were injected via the animal pole with 6 ng/32.2 nl sTeLIC WT or mutant cDNA using a Nanoject II microinjector (Drummond Scientific). After injection ...
-
bioRxiv - Cell Biology 2024Quote: ... Microinjection protocol was followed as mentioned previously 19 using Nanoject II injector (Drummond Scientific Company, Broomall, PA, USA, 3-000-204) for prepharyngeal injection of ds RNA ...
-
bioRxiv - Neuroscience 2024Quote: ... Mice were then injected using a Nanoject II (Drummond Scientific). Mice were injected in the Calustrum (AP +0.7 mm ...
-
bioRxiv - Biophysics 2024Quote: ... Kir4.1 and Kir7.1 RNA using a Drummond Nanoject II injector (Drummond Scientific Company). After microinjection ...
-
bioRxiv - Molecular Biology 2024Quote: ... insects were anesthetized on ice and microinjected with 80 nanoliter of 1,000 ng/μl of dsRNA targeting PmRuvbl1 (dsRUVBL1) or dsGFP at speed of 50 nl/sec using a Nanoinjector III (Drummond Scientific) under a Leica S APO stereo microscope ...
-
bioRxiv - Biochemistry 2024Quote: ... the needles were fixed onto the Nanoliter Injector (Drummond Scientific Company, Nanoject III #3-000-207) and the Nanoliter micropipette was moved to the injection site (1.5 mm M/L ...
-
bioRxiv - Neuroscience 2024Quote: ... Drugs were injected using a Nanoject III Programmable Nanoliter Injector (Drummond Scientific, Broomall, PA) assembled with a glass pipette at the rate of 10 nl/s (modal injection volume ...
-
bioRxiv - Neuroscience 2024Quote: ... at each of 3 depths (150, 250 and 350 μm) via a sharp glass pipette using a Nanoject III (Drummond Scientific). A glass window was then used to seal the craniotomy ...
-
bioRxiv - Molecular Biology 2024Quote: ... Oocytes were immersed in ND96 solution and injected via Nanoject (Drummond Scientific, USA) using pulled glass capillaries (World Precision Instruments ...
-
bioRxiv - Immunology 2024Quote: ... Injections were performed using Nanoject III manual injector (Drummond Scientific). To assess gene-silencing ...
-
bioRxiv - Neuroscience 2024Quote: ... Viruses were injected using a pulled glass capillary (Drummond Scientific Company: 5-000-2005) at a rate of 100 nL/minute ...
-
bioRxiv - Microbiology 2024Quote: ... One μl Microcaps capillaries (Drummond Scientific, Broomall, PA, USA) were heat-sealed at one end and filled with buffer (control ...
-
bioRxiv - Molecular Biology 2024Quote: ... Samples were then loaded into a quartz capillary (0.9 mm ID, 1.3 mm OD; #2-000-050, Drummond Scientific Company) with a volume of approximately 30 μL ...
-
bioRxiv - Neuroscience 2024Quote: ... 250nL of viruses were gently delivered through Nanoject III injector (Drummond Scientific Company, PA, USA) at rate of 40nL/mins ...
-
bioRxiv - Neuroscience 2024Quote: ... either AAV5-CaMKIIa-eYFP-eNpHR3.0 or AAV2/5-CamMKIIa-EYFP-WPRE-hGHpA using a Nanoject (Drummond Scientific) in FOF ...
-
bioRxiv - Neuroscience 2024Quote: ... 0.2µl/virus/site) using a Nanoject III (Drummond scientific company, 3-000-207) tipped with a glass micropipette ...
-
bioRxiv - Zoology 2024Quote: ... was delivered into hemolymph from dorsal abdomens using the Nanoject II microinjection system (Drummond Scientific Company, Broomall, PA, USA). An equivalent amount of solvent was used as a solvent control.
-
bioRxiv - Pathology 2024Quote: Tear samples were collected successively from both eyes for 1 minute each using 1µL microcapillary glass tubes (Merck, Drummond Scientific, reference P1424-1PAK). The samples from both eyes were pooled in the same tube for each mice ...
-
bioRxiv - Immunology 2024Quote: ... 2 day old adult female mosquitoes were injected intrathoracically with 69 nL of 3 ug/uL dsRNA solution using a nanoinjector (Nanoject III, Drummond Scientific, Broomall, PA, USA). For kd control ...
-
bioRxiv - Immunology 2024Quote: ... Infections were done by intrathoracic injection (Nanoject II apparatus; Drummond Scientific) of a 69nL of 150ng of dsRNAs or viral suspension (5000 PFU/fly for VSV-WT and 500PFU/fly for VSV-GFP and SINV-GFP) ...
-
bioRxiv - Microbiology 2024Quote: ... individual mosquitoes aged 5 to 7 days post-emergence were injected intrathoracically with 5 ×104 PFU/mosquito using a Nanoject II Auto-Nanoliter injector (Drummond Scientific). Mosquitoes were allowed to recover at 28°C and 80% humidity with access to 10% (w/vol ...
-
bioRxiv - Microbiology 2024Quote: ... and incubated for 20 min at room temperature prior to thoracic microinjection of 1- and 2-day-old cold-anaesthetised female mosquitoes using a nanoinjector (Nanoject III, Drummond Scientific). Mosquitoes were allowed to recover at 28°C and 80% humidity with access to 10% (w/vol ...
-
bioRxiv - Neuroscience 2024Quote: ... The acid was injected using a Nanojet II (Drummond Scientific Company). Animals were anaesthetised with isoflurane (anaesthesia induced at 5% concentration and maintenance below 3% in medical air) ...
-
bioRxiv - Neuroscience 2024Quote: ... Injection was achieved by connecting a glass pipette with tip diameter 20-30 μm to Nanoject III programmable nanoliter injector (Drummond Scientific Company, USA). To enhance virus infection efficiency ...
-
bioRxiv - Neuroscience 2024Quote: ... A Wiretrol 10 µl capillary micropipette (Drummond Scientific, 21-175B) was pulled and the tip broken to make a 10 µm opening ...
-
bioRxiv - Neuroscience 2024Quote: ... a glass needle pulled from a Wiretrol 10 µl capillary micropipette (Drummond Scientific, 21-175B) was filled with mineral oil (Sigma ...
-
bioRxiv - Pathology 2024Quote: DWV was inoculated through injection (Nanoject II - Drummond Scientific, Broomall, PA, USA) between the third and fourth tergites of emerging bees ...
-
bioRxiv - Immunology 2024Quote: ... flies were anesthetized with CO2 and injected with 23 nl of virus or PBS using a pulled 0.53-mm glass needle and an automatic nanoliter injector (Drummond Scientific, Broomall, PA). Individual flies were injected at the ventrolateral surface of the fly thorax and placed into new vials ...
-
Cortical synaptic vulnerabilities revealed in a α-synuclein aggregation model of Parkinson’s diseasebioRxiv - Neuroscience 2024Quote: ... The injection was performed using a Nanoject III microinjector (Drummond Scientific) at a rate of 20 nL/s over 100 cycles with a delay of 8 s between cycles ...
-
bioRxiv - Neuroscience 2024Quote: ... we used a Nanoject II (Drummond Scientific) to inject 4 x 300 nL of virus at a rate of 100 nL/min ...
-
bioRxiv - Neuroscience 2024Quote: ... Virus was delivered at a rate of 1–2 nl/s using Nanoject III (Drummond Scientific, USA) and injected at three cortical depths covering all layers of the VISp ...
-
bioRxiv - Neuroscience 2024Quote: ... Pulled capillary glass micropipettes (Drummond Scientific, Broomall, PA) were back-filled with AAV solution and injected into the target brain regions at 0.8nL/s using a precision injection system (Nanoliter 2020 ...
-
bioRxiv - Neuroscience 2024Quote: ... at a 6° lateral angle and a rate of 10 nL/s using a custom glass pipette connected to a nanojector (Drummond Scientific Company, Broomall, PA, USA). Rats were monitored post-operatively for two weeks following surgery.
-
bioRxiv - Neuroscience 2024Quote: ... We injected 150 nl of CTB-555 at a rate of 2 nl/s using a Nanoject III microinjection pump (Drummond Scientific, Broomall, PA). Following injection ...
-
bioRxiv - Neuroscience 2024Quote: ... using Nanoject III (Drummond Scientific, total volume = 750 nL ...
-
bioRxiv - Neuroscience 2024Quote: ... mouse pups were anesthetized using hypothermia and injections were performed using a beveled glass micropipette attached to a nanojector (Nanoject III; Drummond Scientific, Broomall, PA). Following injections ...