Labshake search
Citations for Epigentek Group :
1 - 50 of 66 citations for Protein DNA Interaction Assay since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2021Quote: EpiQuik Colorimetric General Protein-DNA Binding Assay Kit (Epigentek Inc., cat# P-2004-96) was used for measuring DNA binding ability of PNKP WT ...
-
bioRxiv - Molecular Biology 2021Quote: ... EpiQuik DNA methyltransferase activity/inhibition assay kit (Epigentek, USA); ScriptSeq v2 RNA-Seq library preparation kit (Epicentre Technologies ...
-
bioRxiv - Cancer Biology 2020Quote: ... the dCas9 protein was quantified using the CRISPR/Cas9 assay ELISA kit (Epigentek).
-
bioRxiv - Molecular Biology 2021Quote: DNMTs activity was measured by EpiQuik DNA Methyltransferase Activity/Inhibition assay kit (Epigentek) according to the manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2023Quote: ... We analyzed SUMOylation of Menin by using the EpiQuikTM In Vivo Universal Protein Sumoylation Assay Kit (EPIGENTEK). Briefly ...
-
bioRxiv - Molecular Biology 2020Quote: Total DNMT activity was measured using EpiQuik™ DNA Methyltransferase Activity/Inhibition Assay Kit (P-3001; Epigentek, Farmingdale, NY, USA) according to manufacturer’s instructions ...
-
bioRxiv - Biochemistry 2023Quote: ... The collected nuclear extracts (20 μg protein) were then used to measure global DNA methylation and DNMT and TET activities with kits from Epigentek (USA).
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... Protease cleavage (PC) assay buffer (EpiGentek) was used as the assay solutions ...
-
bioRxiv - Immunology 2021Quote: ... Protease cleavage (PC) assay buffer (EpiGentek) was used to prepare the furin solutions ...
-
bioRxiv - Evolutionary Biology 2022Quote: m6A RNA Methylation Assay Kit (Fluorometric; Epigentek) was used to measure the m6A level in total RNA by MultiSkan FC microplate reader (Thermo Fisher ...
-
bioRxiv - Microbiology 2023Quote: Global DNA methylation level: MethylFlash methylated DNA Quantification Fluorometer Kit (Epigentek) was used to detect the global methylation level in DNA isolated from primary colonic cells co-cultured with P ...
-
bioRxiv - Physiology 2019Quote: ... Levels of 8-OHdG in RBC DNA was quantified using a competitive immunoassay (300ng DNA, EpiQuick 8-OHdG DNA Damage Quantification Direct Kit Colorimetric, Epigentek, USA) following the manufacturer recommendations ...
-
bioRxiv - Cancer Biology 2022Quote: ... for oxidative DNA damage in DNA samples using the EpiQuik™ 8-OHdG DNA Damage Quantification Direct Kit (Colorimetric) from Epigentek following manufacturer instructions ...
-
bioRxiv - Microbiology 2022Quote: Assessment of Gal-9 effects on the binding of the SARS-CoV-2 spike to human ACE2 was performed using a commercially available spike-ACE2 binding assay kit (CoviDrop SARS-CoV-2 Spike-ACE2 Binding Activity/Inhibition Assay Kit, EPIGENTEK, D-1005-48) following the protocol provided by the manufacturer ...
-
bioRxiv - Molecular Biology 2023Quote: DNA damage was analyzed using EpiQuik 8-OHdG DNA Damage Quantification Direct Kit (P-6003, EpiGentek) according to the manufacturer’s protocol ...
-
bioRxiv - Cancer Biology 2020Quote: ... Genomic DNA (2.4 μg) extracted from cells were bisulfite converted using the Methylamp DNA Modification Kit (Epigentek). The region of interest was PCR amplified in four 50 μL reactions using the following conditions ...
-
bioRxiv - Cell Biology 2022Quote: ... Total 5mC levels within genomic DNA were measured with the MethylFlashTM Methylated DNA Quantification Kit (Epigentek, USA) using 100ng of input DNA ...
-
bioRxiv - Epidemiology 2019Quote: ... Bisulfite modification of 200 ng of genomic DNA was performed using the BisulFlash DNA Modification Kit (EpiGentek, USA) by standard methods ...
-
bioRxiv - Genetics 2021Quote: Extracted DNA (10-200 ng) was bisulphite converted using the Methylamp DNA Modification Kit (#P-1001-2, Epigentek) and eluted in 18 μl elution buffer ...
-
bioRxiv - Physiology 2023Quote: DNA methylation levels were measured using the MethylFlash TM Global DNA Methylation (5-mC) ELISA Easy Kit (Epigentek) following the manufacturer’s recommendations ...
-
bioRxiv - Biochemistry 2023Quote: ... DNA methylation was assessed using a quick EpiQuik Tissue Methylated DNA immunoprecipitation kit (Cat # P-2020, EpiGentek, NY, USA) followed by PCR according to the manufacturer’s protocol.
-
bioRxiv - Molecular Biology 2022Quote: ... and EpiQuik HAT Activity/Inhibition Assay Kit (EpiGentek, Farmingdale, New York, USA) according to manufacturer’s guidelines ...
-
bioRxiv - Neuroscience 2020Quote: Global DNA methylation was measured using the Methyl Flash Global DNA Methylation (5mC) ELISA Easy Kit (Colorimetric) (EpiGenteK, Farmingdale, NY), according to manufacturer’s instructions ...
-
The anti-lipidemic drug simvastatin modulates Epigenetic Biomarkers in the Amphipod Gammarus locustabioRxiv - Pharmacology and Toxicology 2020Quote: Global DNA methylation was determined in eight DNA samples per treatment using the MethylFlash Global DNA Methylation (5-mC) ELISA Easy Kit (Colorimetric) from Epigentek® according to the manufacturer’s instructions ...
-
bioRxiv - Cancer Biology 2022Quote: ... We used the EpiQuik Histone Methyltransferase Activity/Inhibition Assay Kit (H3-K27) (EpigenTek). We measured the absorbance at 450 nm for each sample and generated a standard curve ...
-
bioRxiv - Plant Biology 2022Quote: Global DNA methylation levels were quantified by using 100 ng of genomic DNA from each sample and MethylFlash Methylated DNA Quantification Kit (Colorimetric; Epigentek, NY). This ELISA-based procedure estimates 5-methyl-cytosine fraction in genomic DNA extracts by using specific antibodies ...
-
bioRxiv - Molecular Biology 2020Quote: Isolation of genomic DNA was conducted using the FitAmp™ Blood and Cultured Cell DNA Extraction Kit (EpiGentek, Farmingdale, NY, USA) according to the manufacturer’s instructions ...
-
“Long-Term Quarantine is Associated with High Cortisol and Low DNA Methylation in New World monkeys”bioRxiv - Animal Behavior and Cognition 2024Quote: ... The 5 mC methylation content was measured in 100 nanograms of DNA using the MethylFlash Global DNA Methylation ELISA Easy-colorimetric test kit (Cat. No. P1030, Epigentek, USA). Colour change was measured in a plate reader (Varioscan ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... Here we quantified levels of 8-OHdG in the DNA extracted from embryos using a competitive immunoassay (300 ng DNA, EpiQuick 8-OHdG DNA Damage Quantification Direct Kit Colorimetric, Epigentek, USA) following the manufacturer recommendations ...
-
bioRxiv - Plant Biology 2021Quote: Global genomic methylation levels were determined using 100 ng of DNA for each sample using the MethylFlash Methylated DNA Quantification Kit Colorimetric (Epigentek, #P-1034). The absolute methylation level was determined using a standard curve ...
-
bioRxiv - Molecular Biology 2020Quote: ... Methylflash Methylated DNA Quantification Kit (Epigentek, Farmingdale, NY, USA) and MethylFlash HydroxyMethylated DNA Quantification Kit were used in order to detect methylated and hydroxymethylated DNA ...
-
bioRxiv - Microbiology 2022Quote: ... MethylFlash Methylated DNA 5-mC Quantification Kit (Epigentek, US) as per manufacturer’s instructions ...
-
bioRxiv - Physiology 2023Quote: Oxidative DNA damage quantification was carried out using the EpiQuikTM 8-OHdG DNA damage quantification direct kit (Epigentek Group, Inc., Farmingdale, NY USA). This is based on colorimetric quantification of oxidized guanosine residues (8-hydroxy-2-deoxyguanosine ...
-
bioRxiv - Neuroscience 2020Quote: ... nuclear proteins were extracted using the EpiQuick Nuclear Extraction Kit (Epigentek) according to the manufacturer’s protocol.
-
bioRxiv - Cancer Biology 2022Quote: ... Measurement of LSD1 activity was performed with Epigenase LSD1 Demethylase Activity/Inhibition Assay Kit (Epigentek) according to the manufacturer’s instructions ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... The collected samples were released into 300 μl of protease cleavage (PC) assay buffer (EpiGentek) or NaCl solution at different concentrations by rotating the swab in the buffer for 30 sec ...
-
bioRxiv - Neuroscience 2024Quote: ... the MethylFlash Global DNA Methylation (Epigentek; specific for 5-mC) ELISA kit was used per the manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2020Quote: Chromatin immunoprecipitation (ChIP) assays were conducted with an EpiQuik Chromatin Immunoprecipitation Kit (Epigentek, Farmingdale, NY, USA) according to the manufacturer’s protocol ...
-
bioRxiv - Molecular Biology 2023Quote: ChIP assay was performed using ChromaFlashTM One-Step ChIP Kit (P-2025, Epigentek, Farmingdale, NY, USA) according to the manufacture’s instruction ...
-
bioRxiv - Cancer Biology 2020Quote: ... the purified DNA was incubated and hydrolyzed enzymatically (EpiQuik, Epigentek Group Inc.) to its nucleoside bases (e.g ...
-
bioRxiv - Genetics 2020Quote: ... we added a spike-in of unmethylated DNA (P-1025-1, EpiGentek) equal to 0.01% of the sample DNA mass to each sample ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: The MethylFlash Global DNA Methylation (5-mC) ELISA Easy Kit (Epigentek, USA), utilising a colourimetric assay ...
-
bioRxiv - Molecular Biology 2021Quote: ... DNA was then shipped to a commercial vendor (EpiGentek Group Inc.; Farmingdale, NY, USA) for RRBS as described below.
-
bioRxiv - Cell Biology 2022Quote: ... Total 5hmC quantification was performed with the MethylFlashTM Hydroxymethylated DNA Quantification Kit (Epigentek, USA) using 200ng of input DNA ...
-
bioRxiv - Cell Biology 2023Quote: ... the histone extraction kit (OP-0006) and the EpiQuikTM Histone H3 modification Multiplex assay kit (P-3100) were purchased from Epigentek and protocol followed according to manufacturers’ instructions ...
-
bioRxiv - Cancer Biology 2020Quote: ... Nuclear protein was then isolated from cells using the EpiQuik Nuclear Extraction Kit (EpiGentek Group Inc.), according to the manufacturer’s instructions ...
-
bioRxiv - Cell Biology 2019Quote: ... and global 5mC content was measured by MethylFlash Methylated DNA 5-mC Quantification Kit (Epigentek) according to manufacturer’s instructions.
-
bioRxiv - Plant Biology 2020Quote: HDA activity was measured using a commercially available EpigenaseTM HDAC Activity/Inhibition Direct Assay Kit (Epigentek, Cat No. P-4035-48) according to the manufacturer’s instruction ...
-
bioRxiv - Cancer Biology 2020Quote: ... Nuclear proteins were extracted using the EpiQuik Nuclear Extraction Kit following the manufacturer’s instructions (Epigentek, Farmingdale, NY). Nuclear extracts were frozen at − 80°C until use ...
-
bioRxiv - Immunology 2021Quote: ... and His-tagged SARS-CoV-2 S1 RBD protein lacking the S1/S2 boundary furin site (EpiGentek) were added at a concentration of 10 ng/well to the Ni-NTA-coated strips and incubated for 1h at 37°C ...