Labshake search
Citations for Molecular Devices :
101 - 150 of 235 citations for ssc mir 376a 5p Real time RT PCR Detection Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2023Quote: ... The detection system consisted of 2 µM Safraine O and fluorescence was monitored using a microplate reader (SpectraMax Paradigm, Molecular Devices) at Λexcitation= 495 nm ...
-
bioRxiv - Neuroscience 2023Quote: ... Extranuclear DNA-histone complexes were measured with Cell Death Detection ELISAPlus at 405 nm using the SpectraMax i3x Multi-Mode Microplate Reader (Molecular Devices). Results are expressed as percent change compared with untreated control cells.
-
bioRxiv - Neuroscience 2023Quote: ... One threshold detection method (at least 2X baseline amplitude) was used to detect high-frequency activity events using Clampfit 10 software (Molecular Devices Inc. ...
-
bioRxiv - Neuroscience 2023Quote: ... the cells were washed three times with PBS and 50 µL of assay buffer was added per well prior to detection with a FlexStation I Plate Reader (Molecular Devices). GluA2 receptor activation from application of compound solution was detected as relative fluorescence unit (RFU ...
-
bioRxiv - Cell Biology 2024Quote: ... TO-PRO-3 fluorescence intensity was measured in the temperature-controlled plate reader (Spectra Max i3X Multi-Mode Detection Platform, Molecular Devices) or by quantitative fluorescence microscopy as indicated in the Figure Legends.
-
bioRxiv - Synthetic Biology 2019Quote: ... The reaction was incubated for 60 min at RT and absorbance was measured at 593 nm using a plate reader (SpectraMax M5, Molecular Devices). To calculate iron concentrations ...
-
bioRxiv - Biochemistry 2021Quote: ... centrifugal drying (1,000 rpm for 5 min at RT) was performed and the arrays scanned using a GenePix scanner (4100A by Molecular Devices). Microarray images were gridded and quantitated using GenePix Pro (v7 ...
-
bioRxiv - Biochemistry 2022Quote: ... Absorbance at 340 nm was measured at RT every 30 seconds for 1 h with a SpectraMax Plus 384 microplate reader (Molecular Devices). Data analysis was done using SoftMax Pro 7.0 and GraphPad Prism 9.3.1 software ...
-
bioRxiv - Biochemistry 2023Quote: ... Samples incubated an additional 10 minutes at RT prior to reading Abs620 nm values using a FlexStation plate reader (Molecular Devices). Data were imported into R.Studio where the phosphate standards were used to generate a phosphate standard curve ...
-
bioRxiv - Microbiology 2022Quote: ... Homogenous Time-Resolved Fluorescence (HTRF) measurements were performed on a SpectraMax iD5 plate reader (Molecular Devices) according to the manufacturer’s guideline (excitation wavelength 340 nm ...
-
bioRxiv - Bioengineering 2022Quote: ... Luminescence at integration time of 1000 ms was obtained using the SpectraMax M3 Spectrophotometer (Molecular Devices) using SoftMax Pro (Version 7.0.2 ...
-
bioRxiv - Cancer Biology 2020Quote: ... Images were acquired at the initial time point and after 21h with MetaXpress microscope (Molecular Devices). Images were analyzed using the MRI Wound Healing Tool in ImageJ (Schindelin ...
-
bioRxiv - Cell Biology 2022Quote: Time-lapse live-cell imaging was performed on an ImageXpress Nano Automated Imaging System (Molecular Devices). A SOLA Light Engine (Lumencor ...
-
bioRxiv - Bioengineering 2022Quote: ... Luminescence at integration time of 1,000 ms was obtained using the SpectraMax M3 Spectrophotometer (Molecular Devices) using SoftMax Pro (Version 7.0.2 ...
-
bioRxiv - Physiology 2022Quote: Time lapse ER [Ca2+] measurements were performed using the FlexStation3 fluorometer (Molecular Devices, San Jose, CA) (Murayama et al. ...
-
bioRxiv - Genomics 2020Quote: ... and OVCAR8 cell line validation was performed by 24-48h Dox induction at 10μg/ml following GFP detection by microscopic measurement using ImageXpress Micro XLS Widefield Microscope (Molecular Devices, Sunnyvale, CA) or Incucyte Zoom (Essenbioscience ...
-
bioRxiv - Genomics 2020Quote: ... Validation of transgene activation cells were treated with Dox (10μg/ml) for 24-48h following GFP detection using ImageXpress Micro XLS Widefield Microscope (Molecular Devices, Sunnyvale, CA). Validation of transgene locus insertion was validated by junction and AAVS1 locus PCR.
-
bioRxiv - Neuroscience 2020Quote: ... Neurons ∼50µm below the slice surface were targeted for whole-cell patch-clamp recordings at RT using a MultiClamp 700B amplifier and a Digidata 1440A digitiser (Molecular Devices, USA). A standard potassium-based intracellular electrode solution of the following composition (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole-cell patch clamp electrophysiological recordings were performed at RT using a Multiclamp 700B amplifier and Digidata 1440A digitizer (Molecular Devices, USA). Patch pipettes were obtained from borosilicate glass microelectrodes (6-9 MΩ ...
-
bioRxiv - Cell Biology 2020Quote: Automated time-lapse microscopy was performed using an ImageXpress Micro XLS wide-field screening microscope (Molecular Devices) equipped with a 10x ...
-
bioRxiv - Bioengineering 2020Quote: ... Time-lapse images of the turboGFP fluorescence were captured using the MetaMorph® imaging software (Molecular Devices). After focusing ...
-
bioRxiv - Neuroscience 2022Quote: ... The kinetics analysis of the IPSCs decay time were performed on Clampfit (Molecular Devices, San Jose, USA) from averaged traces.
-
bioRxiv - Synthetic Biology 2023Quote: ... OD600 measurement was checked at frequent time intervals (3-6 h) on SpectraMax M3 spectrophotometer (Molecular Devices). Growth rate was determined by plotting the values in GraphPad Prism following non-linear regression and using exponential growth equation ...
-
bioRxiv - Microbiology 2024Quote: ... Fluorescence or absorbance was measured over time using a SpectraMax M5 model by Molecular Devices (for TMPRSS2) and Cathepsins B and L ...
-
bioRxiv - Bioengineering 2022Quote: ... We then used colorimetric detection to measure the absorbance of each well at 450 nm wavelength with a spectrophotometer (Molecular Devices, SpectraMax i3). We compared the absorbances with a previously obtained standard curve of human insulin (Figure S6) ...
-
bioRxiv - Biochemistry 2022Quote: ... The time course of the fluorescence change was measured with a SpectraMax Gemini EM Microplate Reader (Molecular Devices) with excitation at 365 nm and emission at 407 nm in a Costar 3694 EIA/RIA ...
-
bioRxiv - Genetics 2022Quote: ... Fluorescence over time quantification and trace analysis were automatically quantified using custom software packages developed by Molecular Devices and Colas lab ...
-
bioRxiv - Pathology 2022Quote: ... Fluorescence over time quantification and trace analysis were automatically quantified using custom software packages developed by Molecular Devices and Colas lab ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Time-lapse [Ca2+]ER measurements were performed using the FlexStation 3 fluorometer (Molecular Devices, San Jose, CA, USA), as described previously (Murayama and Kurebayashi ...
-
bioRxiv - Cell Biology 2023Quote: ... and videos were recorded at 2 frames/sec with 100ms exposure time using MetaMorph acquisition software (Molecular Devices). The excitation light was passed through a cyan excitation filter (Chroma) ...
-
bioRxiv - Cell Biology 2023Quote: ... Fluorescence over time quantification and trace analysis were automatically quantified using custom software packages developed by Molecular Devices and Colas lab ...
-
bioRxiv - Cell Biology 2024Quote: ... Time-lapsed images were measured every 6 seconds for 6 minutes for 20 minutes using Metamorph (Molecular Devices). Change to fluorescence intensity was calculated using baseline calcium levels per cell.
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Time-lapse confocal imaging was performed using a temperature controlled ImageXpress MicroXL High Content Imaging microscope (Molecular Devices). The microscope temperature was set to mimic cell culture conditions (37°C ...
-
bioRxiv - Immunology 2021Quote: ... RnD), IL4 (DY204, detection limit 0.25 pg/ml, RnD) Developed plates were read in a SpectraMax340 Microplate reader (Molecular Devices, San Jose, CA, USA) and absolute protein levels were calculated after serial dilutions of the recombinant protein provided by the manufacturer.
-
bioRxiv - Cancer Biology 2020Quote: ... At defined time points cells were imaged and analysed using the ImageXpress Micro Confocal microscope (Molecular Devices, California, USA).
-
bioRxiv - Biochemistry 2022Quote: ... and then read (1700 ms integration time) using a SpectraMax i3x with a rhodamine fluorescence polarization cartridge (Molecular Devices). Wells containing only assay buffer were used for background subtraction ...
-
bioRxiv - Neuroscience 2020Quote: ... time of the first peak and area under the curve of Ca2+ signals were analyzed in ClampFit10.7 (Molecular Devices).
-
bioRxiv - Pathology 2023Quote: ... and time constant of hyperpolarization of single action potentials were analyzed using a Clampfit program (version 10.7, Molecular Devices). The rheobase current ...
-
bioRxiv - Synthetic Biology 2023Quote: ... Cell growth OD600 measurement was checked at frequent time intervals (3–6 h) on SpectraMax M3 spectrophotometer (Molecular Devices). Growth rates (μ ...
-
bioRxiv - Immunology 2022Quote: ... The plate was then incubated for 30 min at RT in the dark before the AlphaLISA signal was detected using a SpectraMax® i3x multi-mode microplate reader (Molecular Devices, San Jose, CA). The antibodies selected from the initial screening of supernatants were expressed and purified in large scale ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Cells were then incubated for 24 hours at 4°C before reading by time-resolved Förster resonance energy transfer (TR-FRET) in a Flexstation 3 plate reader (Molecular Devices) using the following settings ...
-
bioRxiv - Cell Biology 2021Quote: ... The cells were then washed 4 times with fresh pre-warmed Tyrode’s solution and automatically imaged with an ImageXpress Micro XLS microscope (Molecular Devices) at an acquisition frequency of 100 Hz for a duration of 5 s with excitation 485/20 nm and emission 525/30 nm filters ...
-
bioRxiv - Cell Biology 2021Quote: ... Fluorescence quantification over time and single-cell trace analysis were automatically performed using custom software packages developed by Molecular Devices and the Colas laboratory.
-
bioRxiv - Microbiology 2022Quote: ... Cells were washed 3 final times with 1X PBS before image collection with an ImageXpress inverted confocal microscope (Molecular Devices). Image analysis was completed using MetaXpress analysis software (Molecular Devices).
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... For analysis of Ca2+ transient rise and decay times Ca2+ data were analysed using pClamp v10 (Molecular Devices, CA, USA) to generate times corresponding to 10-90% and 10-50% rise time ...
-
bioRxiv - Neuroscience 2020Quote: ... The plate fluorescence was measured at the indicated time points using a SpectraMAX M2 spectrophotometer (Molecular Devices, San Jose, CA), with an excitation peak at 450 nm and emission peak at 485 nm and a 475 nm band pass cutoff ...
-
bioRxiv - Microbiology 2023Quote: ... The time-dependent NADH oxidation by Mdh was monitored at 340 nm in a Spectra Max MP3 Microplatereader (Molecular Devices). At least three replicates of these experiments were analyzed ...
-
bioRxiv - Genomics 2020Quote: ... Luciferase activity was measured 48-hours post-transfection with a 2-second integration time on a LMax II 384 Luminometer (Molecular Devices). Background subtracted luminescence values for each SNV were z-scored ...
-
bioRxiv - Microbiology 2019Quote: ... covered with a transparent seal and quickly thereafter absorbance at 572 nm (A572) was monitored over time in a 96-well plate reader for at least 200 minutes (SpectraMax Paradigm, Molecular Devices). The A572 values were processed using RStudio software (RStudio-Team 2016 ...
-
bioRxiv - Neuroscience 2021Quote: ... the head X coordinate was used to calculate the animal’s speed sx using the gradient over time. Head X coordinate (treadmill) and calculated velocity (corridor) were then exported to Clampfit (Molecular Devices) and interpolated to 10 kHz to match the acquisition framerate of diaphragmatic EMG recordings ...