Labshake search
Citations for Molecular Devices :
51 - 100 of 117 citations for Vitamin A Retinol ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... The supernatant was collected and spectrophotometrically analyzed (λ = 620 nm) with a microplate reader (Molecular Devices, VersaMax ELISA microplate reader, USA) to determine the Evans blue content ...
-
bioRxiv - Immunology 2021Quote: ... GABA concentrations in supernatants were quantified from the standard curve generated at a wavelength of 450 nm (VMax® Kinetic ELISA Microplate Reader, Molecular Devices) by ELISA (Labor Diagnostica Nord ...
-
bioRxiv - Microbiology 2022Quote: ... and the reaction was stopped with 1M H2SO4 and absorbance at 450 nm was determined using an ELISA reader (Molecular Devices SPECTRAmax).
-
bioRxiv - Microbiology 2023Quote: ... The plate was incubated at 37°C for 60 min before the absorbance was measured at 405 nm using an ELISA plate reader (SpectraMax Plus 384 Microplate Reader from Molecular Devices; Software: SoftMax Pro 7 Software, Molecular Devices). The IgA concentration was determined for each sample using the formulated standard curve.
-
bioRxiv - Immunology 2024Quote: ... After washing the plate 3 times with 1X PBST the color was developed using TMB Sureblue followed by Stop solution before the absorbance was measured at OD 450 nm using an ELISA plate reader (Molecular Devices Spetramax).
-
bioRxiv - Microbiology 2021Quote: ... Absorbance was measured at 490 nm using an enzyme-linked immunosorbent assay (ELISA) reader (SPECTRA max plus 384, Molecular Devices, Sunnyvale, CA, USA). The resulting optical densities were normalized with dimethylsulfoxide (DMSO ...
-
bioRxiv - Immunology 2021Quote: ... The optical density (OD) was measured at 450 nm using an ELISA plate reader (Filter-Max F5, Molecular Devices, San Jose, CA, USA). All samples were tested in triplicate and the average value of three blanks (no Abs ...
-
bioRxiv - Microbiology 2023Quote: ... purple colored solution was analyzed by taking absorbance using a microplate (ELISA) reader at 570 nm and 620 nm using M4 SpectraMax® (Molecular Devices LLC). Deeper the purple color ...
-
bioRxiv - Immunology 2021Quote: ... The reaction was stopped by the addition of 1% SDS per well and the absorbance (A) was measured at 405 nm (A405) using an ELISA reader Spectramax (Molecular Devices, San Jose, CA) within 30 min of stopping the reaction ...
-
bioRxiv - Immunology 2021Quote: ... The reaction was stopped by the addition of 1% SDS per well and the absorbance (A) was measured at 405 nm (A405) using an ELISA reader Spectramax (Molecular Devices, San Jose, CA)) within 30 min of stopping the reaction. ...
-
bioRxiv - Microbiology 2020Quote: ... The optical density of the samples was measured using an EMax® ELISA Microplate Reader with SoftMax® Pro software (Molecular Devices©, Sunnyvale, California). Samples were background subtracted from negative control wells to which no macaque plasma was added ...
-
bioRxiv - Neuroscience 2024Quote: ... The optical density (OD) was measured at 450 nm and 630 nm using an ELISA microplate reader (SynergyMax M5, iD5, Molecular Devices, San Jose, CA, USA).
-
bioRxiv - Neuroscience 2020Quote: ... The EarlyTox Cardiotoxicity Kit (Molecular Devices) was used to measure calcium flux as a proxy for cardiomyocyte beating activity112 ...
-
bioRxiv - Cancer Biology 2020Quote: ... EarlyTox Dead Assay Kit (Molecular Devices), or Click-IT EdU Kit (ThermoFisher Scientific) ...
-
bioRxiv - Immunology 2021Quote: ... Calcium 5 Assay Kit (Molecular devices) for 1 h at 37° C ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... EarlyToxTM Cardiotoxicity Kit (Molecular Devices LLC, CA, USA) by incubation for 2 hour in culture medium ...
-
bioRxiv - Bioengineering 2022Quote: ... an EarlyTox Live/Dead Assay kit was used (Molecular Devices) and the microplate was imaged with a laser and GFP and TXR filters ...
-
bioRxiv - Biochemistry 2023Quote: ... using the Fura-2 QBT™ Calcium Kit (Molecular Devices). Cells were seeded (40 000 cells/well in 200 µl media ...
-
bioRxiv - Molecular Biology 2019Quote: ... and Earlytox live/dead assay kit (Molecular Devices, San Jose, CA) were used for studies of INS-1 cells treated with CSE or AC extract with or without 5 mM N-Acetyl Cysteine (NAC ...
-
bioRxiv - Immunology 2022Quote: ... in conjunction with the FLIPR Calcium 6 dye kit (Molecular Devices) as previously described (Dal Porto et al. ...
-
bioRxiv - Physiology 2023Quote: A Fura-2 QBT Calcium Kit (Molecular Devices; San Jose, CA) was used to assess [Ca2+]i according to manufacturer’s instructions ...
-
bioRxiv - Immunology 2023Quote: ... in conjunction with the FLIPR Calcium 6 dye kit (Molecular Devices). On the day of the experiments ...
-
bioRxiv - Genetics 2022Quote: ... RNA was isolated using the PicoPure Kit (Molecular Devices, Inc., Sunnyvale, CA), and quality and quantity were determined using an Agilent 2100 Bioanalyzer (Agilent Technologies ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... A membrane potential dye (FLIPR Membrane Potential kit BLUE, Molecular Devices R8034) was reconstituted according to the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2023Quote: Organoids were assayed using the FLIPR Calcium 6 assay kit (Molecular Devices). Briefly ...
-
bioRxiv - Immunology 2024Quote: Membrane potential was measured using FLIPR Membrane Potential Assay kit (Molecular devices) according to the manufacturer’s instructions ...
-
bioRxiv - Physiology 2021Quote: ... Calcium assays were performed with the FLIPR Calcium 6 Assay Kit (Molecular Devices) according to the manufacturer’s protocol ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: Ca2+ mobilization experiments were carried using the FLIPR4 calcium assay dye kit (Molecular Devices). As detailed previously (32) ...
-
bioRxiv - Immunology 2020Quote: ... An equal volume of assay loading buffer (FLIPR Calcium 4 assay kit, Molecular Devices) in Hank’s balanced salt solution supplemented with 20 mM HEPES and 2 mM probenecid was added ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Calcium levels were measured using Fluorescent Imaging Plate Reader (FLIPR) calcium 5 assay kit (Molecular Devices) as described previously1 ...
-
bioRxiv - Cell Biology 2022Quote: Brown adipose tissue cAMP levels were measured using the CatchPoint cAMP Fluorescent Assay Kit (Molecular Devices). A small piece of frozen BAT (2 – 5 mg ...
-
bioRxiv - Developmental Biology 2021Quote: ... cultures were prepared according to the instructions detailed in the FLIPR Calcium Assay 6 kit (Molecular Devices). Briefly ...
-
bioRxiv - Neuroscience 2020Quote: ... Potassium flux of cells was measured using FLIPR Potassium Assay Kit (Molecular Devices, LLC, San Jose, CA) according to manufacturer instructions (Shieh et al. ...
-
bioRxiv - Biochemistry 2022Quote: ... and SERT activities were determined using the neurotransmitter transporter update assay kit from Molecular Devices (Category R8174). Briefly ...
-
bioRxiv - Developmental Biology 2022Quote: Calcium imaging was performed using the FLIPR Tetra instrument and FLIPR Calcium 6 Assay Kit (Molecular Devices) according to the manufacturer’s instructions ...
-
bioRxiv - Immunology 2022Quote: ... Luciferase assay was performed using the SpectraMax® Glo Steady-Luc™ Reporter Assay Kit (Molecular Devices) according to the manufacturer’s instructions and relative luciferase activity was measured at the LUMIstar Omega (BMG Labtech ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Changes in [Ca]i were measured using a proprietary assay kit (FLIPR® Ca5, #8186, Molecular Devices), as described previously (Redmond et al. ...
-
bioRxiv - Cell Biology 2022Quote: Intracellular calcium levels were assessed using Fura-2 fluorescence ratio measurement (Fura-2 QBT kit R8197, Molecular Devices) on a FlexStation III reader with automated pipetting at the Harvard ICCB-Longwood screening facility ...
-
bioRxiv - Cell Biology 2020Quote: ... BODIPY-dodecanoic acid fluorescent fatty acid analog was added (QBT™ Fatty Acid Uptake Assay Kit, Molecular Devices) and the plate was immediately transferred to a fluorescence microplate reader for kinetic reading (every 20 seconds for 30-60 minutes ...
-
bioRxiv - Physiology 2022Quote: Primary podocyte cultures were subject to Fura-2 fluorescence ratio measurement (Fura-2 QBT kit R8197, Molecular Devices) using a FlexStation III reader with automated pipetting at the Harvard ICCB-Longwood screening facility in a 96-well format essentially as previously described [30 ...
-
bioRxiv - Neuroscience 2023Quote: ... 21 and 28 post plating cells were loaded with 1X EarlyTOX from the EarlyTOX Cardiotoxicity Kit (Molecular Devices) and incubated for 2 hours at 37 °C ...
-
bioRxiv - Plant Biology 2022Quote: Total RNA was extracted from each laser-dissected tissue sample using the Picopure RNA isolation kit (Molecular Devices, USA), with DNase I treatment ...
-
bioRxiv - Cancer Biology 2023Quote: ... Calcium 6 dye stock solution was prepared by dissolving a vial from Calcium 6 assay kit (Molecular Devices, #5024048) in 10 ml sterile-filtered nominal Ca2+ free (NCF) ...
-
bioRxiv - Molecular Biology 2023Quote: ... dsDNA was quantified in cytoplasmic fraction using the SpectraMax Quant AccuClear Nano dsDNA Assay kit (Molecular devices, Part # R8357). The samples were read using SpectraMax M5 (Molecular Devices ...
-
bioRxiv - Microbiology 2024Quote: ... The cells were stained with the FLIPR calcium indicator Calcium 5 Assay Kit (Molecular Devices Corp., Sunnyvale, CA, USA) to image the Ca2+-transients evoked by capsaicin addition ...
-
bioRxiv - Biochemistry 2020Quote: ... The cAMP content in the lysates was determined according to the manufacturer’s instruction by catch point cAMP immunoassay kit (Molecular Devices) [20].
-
bioRxiv - Cell Biology 2022Quote: Multi-well calcium flux assays were performed with the Fura-2 QBT Calcium Kit (R8197, Molecular Devices, Inc., Sunnyvale, CA). 10,000 – 20,000 cells/well were plated into a 96-well plate to achieve confluence when analyzed ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Changes in membrane potential were measured using a proprietary membrane potential assay kit (MPA Blue, #8034, Molecular Devices, Sunnyvale CA) as described previously (Knapman et al ...
-
bioRxiv - Cancer Biology 2019Quote: ... The phosphorylation of the Hsp27 peptide was quantified using IMAP Progressive Screening Express Kit (Molecular Devices, catalog number R8127, Sunnyvale, CA) and the Analyst HT plate reader ...
-
bioRxiv - Immunology 2019Quote: ... Luciferase activity was quantified using the Secrete-Pair Luminescence Assay Kit (Genecopoieia) and measured with a SpectraMax M5e plate reader (Molecular Devices). Gaussia luciferase (GLuc ...