Labshake search
Citations for Molecular Devices :
251 - 300 of 469 citations for Mouse UDP glucuronosyltransferase 1 2 UGT1A2 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... Membrane voltage and current were sampled at 10-25 kHz and low-pass filtered at 2-10 kHz using the patch clamp amplifier MultiClamp 700B (Molecular Devices, LLC), digitized and sampled by Micro 1401 with Spike2 software (Cambridge Electronic Design ...
-
bioRxiv - Neuroscience 2022Quote: ... Signals were filtered at 200 Hz and digitized at 1 kHz with the MiniDigi 1 digitizer (Molecular Devices) for simultaneous continuous recording of DC potential ...
-
bioRxiv - Physiology 2023Quote: ... Channel currents were recorded at 1 kHz with an Axopatch 1-D amplifier (Molecular Devices Inc., Sunnyvale, CA) with a low-pass 100-Hz 8-pole Bessel filter ...
-
bioRxiv - Physiology 2023Quote: Whole-cell NaV currents were recorded at room temperature from neonatal and adult mouse ventricular cardiomyocytes using an Axopatch 200B amplifier (Axon Instruments, Molecular Devices, San Jose, CA) 48 hours following adenoviral infection ...
-
bioRxiv - Neuroscience 2022Quote: Whole cell patch-clamp recordings were obtained from S1 layer 2/3 neurons with a Multiclamp 700B amplifier (Molecular Devices, San Jose, CA) low-pass filtered at 1.8 kHz with a four-pole Bessel filter ...
-
bioRxiv - Neuroscience 2020Quote: ... and filtered online at 2 kHz with the amplifiers 4-pole Bessel Filter and digitised at 20 kHz (Digidata1550B, Molecular Devices, CA, USA)
-
bioRxiv - Biophysics 2020Quote: ... The recorded signals were filtered at 2 kHz and were digitized at 4 kHz using Digidata 1440A digitizing board (Molecular Devices/Axon Instruments). Occasionally ...
-
bioRxiv - Bioengineering 2022Quote: ... Immediately we stopped the reaction by adding 50 μL of 2 N H2SO4 solution and analyzed on a microplate reader (Molecular Devices, Spectramax I3) at 450 nm wavelength ...
-
bioRxiv - Neuroscience 2021Quote: ... The signal was filtered by a 4-pole low-pass Bessel filter with a cut-off frequency of 2 kHz and digitized utilizing a Digidata 1322A (Molecular Devices, CA, USA). All recordings were performed at room temperature (23°C ...
-
bioRxiv - Neuroscience 2020Quote: ... Data were low-pass filtered at 2 kHz and acquired at 20 kHz with an Axon Multiclamp 700B amplifier (Molecular Devices, Sunnyvale, U.S.A.) using MATLAB (Mathworks ...
-
bioRxiv - Neuroscience 2022Quote: Whole-cell current-clamp recordings were made from layer 2/3 pyramidal cells with a Multiclamp 200B or 700B amplifier (Molecular Devices, San Diego). Cortical regions and layers were identified using IR video microscopy (Olympus ...
-
bioRxiv - Cell Biology 2023Quote: ... 2 μM Rab were incubated with varying amounts of GEF in a SpectraMax M3 Multi-Mode Microplate Reader (Molecular Devices, San Jose, USA) and after base line stabilization ...
-
bioRxiv - Neuroscience 2023Quote: ... The recordings were low-pass filtered at 2 kHz and digitized at 10 kHz using a Multiclamp 700B amplifier (Molecular Devices, Sunnyvale, CA), Digidata 1322A digitizer (Molecular Devices) ...
-
bioRxiv - Physiology 2021Quote: ... Calcium assays were performed with the FLIPR Calcium 6 Assay Kit (Molecular Devices) according to the manufacturer’s protocol ...
-
bioRxiv - Immunology 2021Quote: ... The concentration of both mouse and simian IgG antibodies was calculated relative to the standard using a 5-parameter fit curve (Softmax, Molecular Devices, Sn Jose, CA, USA) and results are expressed as µg/mL of HIV-specific antibodies (IgG ...
-
bioRxiv - Neuroscience 2021Quote: ... DRGs to record spontaneous afferent population activity for a minimum of 25 seconds (50 kHz, Digidata 1322A 16 Bit DAQ, Molecular Devices, U.S.A., Figure 2). Signals were amplified (5000x ...
-
bioRxiv - Neuroscience 2019Quote: ... Electrodes were placed in holders (G23 Instruments, London, UK) connected to the headstage (HS-2) of an amplifier (Axoclamp-2B, Molecular Devices, San Jose, CA). An A/D converter (Digidata 1440A ...
-
bioRxiv - Neuroscience 2020Quote: ... with ACSF-filled glass microelectrodes (2-4 MΩ) positioned within layer II/III of the V1 using an Axopatch 200B amplifier (Molecular devices, San Jose, CA). Electric stimulation (100 μsec duration ...
-
bioRxiv - Neuroscience 2021Quote: ... synaptic currents were filtered at 2 kHz and digitized at 10 kHz (amplifier in-built 8-pole low-pass Bessel filter and Molecular Devices Digidata 1322A, respectively). Recordings used for analysis were post-hoc filtered at 1 kHz.
-
bioRxiv - Neuroscience 2021Quote: ... Data were low-pass filtered at 2 kHz and digitized at 10 kHz with a Digidata 1440 interface controlled by pClamp Software (Molecular Devices, Union City, CA).
-
bioRxiv - Physiology 2021Quote: ... Images were acquired at a frequency of 2 Hz with an exposure time of 500 ms using the MetaMorph software program (ver. 7.8; Molecular Devices, San Jose, CA, USA) in stream acquisition mode ...
-
bioRxiv - Immunology 2022Quote: ... The cells were incubated with LPS with and without a NOX2 inhibitor for 2 h in the assay media and fluorescence was measured using a SpectraMax plate reader (Molecular Devices, San Jose, CA). Fluorescence values were normalized to cell number measured using the Presto Blue Cell Viability Assay (ThermoFischer Scientific ...
-
Dynamic Effects of Ventral Hippocampal NRG3/ERBB4 Signaling on Nicotine Withdrawal-Induced ResponsesbioRxiv - Neuroscience 2023Quote: Currents were low pass filtered at 2 kHz and digitized at 20 kHz using a Digidata 1550B acquisition system (Molecular Devices, San Jose, CA) coupled to the Multiclamp 700B amplifier (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... with signals acquired at 20 kHz and low-pass filtered at 2 kHz using a Digidata 1440A digitizer (Molecular Devices, San Jose, California, USA). The liquid junction potential was corrected at the time of recording.
-
Macropinocytosis mediates resistance to loss of glutamine transport in triple-negative breast cancerbioRxiv - Cancer Biology 2024Quote: ... CCK8 reagent was added for 2 h and absorbance measured at 450 nm on a Spectramax® 190 Microplate Reader (Molecular Devices, CA, USA) at timepoints indicated ...
-
Community-based Reconstruction and Simulation of a Full-scale Model of Region CA1 of Rat HippocampusbioRxiv - Neuroscience 2024Quote: ... Single intracellular recordings were made using sharp microelectrodes (tip resistance, 90-190 MΩ) filled with 2% biocytin in 2M KMeSO4 under current-clamp (Axoprobe; Molecular Devices, Palo Alto, CA). Electrophysiological characteristics of the recorded neurons were obtained from voltage responses to 400 ms current pulses between -1 and +0.8 nA and recorded with pClamp software (Axon Instruments ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: Ca2+ mobilization experiments were carried using the FLIPR4 calcium assay dye kit (Molecular Devices). As detailed previously (32) ...
-
bioRxiv - Immunology 2020Quote: ... An equal volume of assay loading buffer (FLIPR Calcium 4 assay kit, Molecular Devices) in Hank’s balanced salt solution supplemented with 20 mM HEPES and 2 mM probenecid was added ...
-
bioRxiv - Biochemistry 2020Quote: ... Data were collected on a BLItz instrument and analyzed with a 1:1 binding model using BLItz Pro Data Analysis Software (Molecular Devices). The assay buffer was 10 mM HEPES pH 7.6 ...
-
bioRxiv - Biochemistry 2020Quote: BLI kinetics were collected on an Octet RED96a and analyzed with a 1:1 binding model (global fit) using instrument software (Molecular Devices). IgG1 Fc-fused sACE22 (wild type or engineered variant sACE22.v2.4 ...
-
bioRxiv - Neuroscience 2022Quote: ... Whole-cell recordings were acquired at 20 kHz and lowpass filtered at 2 kHz using a Multiclamp 700B amplifier and Digidata 1440A digitizer (Molecular Devices, San Jose, CA, USA). Neuronal intrinsic excitability (input/output curve ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... The plate was placed into a 37°C CO2 conditioned incubator for 30 min before GFP-β-arrestin-2 or rGFP-mini-Gαsi fluorescence levels were measured with a SpectraMax M5 fluorescence plate reader (Molecular Devices, San Jose, California, USA). For β-arrestin-2 experiments ...
-
bioRxiv - Biochemistry 2019Quote: ... was added to final concentration 2 µg/ml and fluorescence was measured at 530 nm excitation and 600 nm emission using a plate reader (Molecular Devices M3 plate reader, USA).
-
bioRxiv - Physiology 2020Quote: ... in the presence of GABAA and GABAB receptor blockers (10 µM gabazine and 2 µM CGP55845, respectively; 30-34°C; Multiclamp 700B amplifier (Molecular Devices, San José, California, USA); 5 kHz low-pass filter ...
-
bioRxiv - Physiology 2023Quote: ... All assays were performed in duplicate on 96 wells plate with an equal quantity of purified protein into each well (200 µg and 2 µg for cytosolic and mitochondrial fractions respectively) and read on a SpectraMax Microplate reader (Molecular Devices, San Jose, CA, USA).
-
bioRxiv - Neuroscience 2023Quote: Data were collected by using one multiClamp 700B amplifier (filtered at 2 kHz) and digitized at 20 kHz by using one Digidata 1440A(Molecular Devices Inc., Union City, CA), along with Clampex 10 software (Molecular Devices Inc. ...
-
bioRxiv - Biochemistry 2024Quote: ... Kinetics of 4-methylumbelliferone release from fluorogenic substrates by glycosidases was recorded as an increase in fluorescence for 2 hours at 37°C using FilterMax™ F5 microplate reader (Ex: 360 nm, Em: 430 nm, Molecular Devices, San Jose, CA). The resulting concentration of 4-methylumbelliferone was determined using a calibration curve ...
-
bioRxiv - Microbiology 2020Quote: ... and filtered at 1 kHz (Digidata 1550A, Molecular Devices). All experiments were performed at −60 mV holding membrane potential (Vh ...
-
bioRxiv - Neuroscience 2021Quote: ... A patch-clamp headstage (Molecular Devices #1-CV-7B) mounted on a motorized 4-axis Siskiyou MX7600 manipulator ...
-
bioRxiv - Microbiology 2020Quote: Binding affinities of S-D4 with SARS-CoV-2 S-RBD were performed by BLI on an Octet RED96 (Molecular Devices LLC, San Jose, CA, USA) using AR2G biosensors ...
-
bioRxiv - Microbiology 2021Quote: ... Growth was determined by measuring the optical density (OD 595 nm) of the suspensions every 2 h using a microplate reader (SpectraMax M2, Molecular Devices, LLC, San Jose, CA, USA).
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Calcium levels were measured using Fluorescent Imaging Plate Reader (FLIPR) calcium 5 assay kit (Molecular Devices) as described previously1 ...
-
bioRxiv - Cell Biology 2022Quote: Brown adipose tissue cAMP levels were measured using the CatchPoint cAMP Fluorescent Assay Kit (Molecular Devices). A small piece of frozen BAT (2 – 5 mg ...
-
bioRxiv - Neuroscience 2020Quote: Recordings were made using an Axopatch 1-D (Molecular Devices), filtered at 5 kHz and collected at 20 kHz using custom procedures written for NIDAQ and IGOR Pro (National Instruments and WaveMetrics ...
-
bioRxiv - Developmental Biology 2021Quote: ... cultures were prepared according to the instructions detailed in the FLIPR Calcium Assay 6 kit (Molecular Devices). Briefly ...
-
bioRxiv - Neuroscience 2020Quote: ... Potassium flux of cells was measured using FLIPR Potassium Assay Kit (Molecular Devices, LLC, San Jose, CA) according to manufacturer instructions (Shieh et al. ...
-
bioRxiv - Biochemistry 2022Quote: ... and SERT activities were determined using the neurotransmitter transporter update assay kit from Molecular Devices (Category R8174). Briefly ...
-
bioRxiv - Developmental Biology 2022Quote: Calcium imaging was performed using the FLIPR Tetra instrument and FLIPR Calcium 6 Assay Kit (Molecular Devices) according to the manufacturer’s instructions ...
-
bioRxiv - Immunology 2022Quote: ... Luciferase assay was performed using the SpectraMax® Glo Steady-Luc™ Reporter Assay Kit (Molecular Devices) according to the manufacturer’s instructions and relative luciferase activity was measured at the LUMIstar Omega (BMG Labtech ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Changes in [Ca]i were measured using a proprietary assay kit (FLIPR® Ca5, #8186, Molecular Devices), as described previously (Redmond et al. ...