Labshake search
Citations for Molecular Devices :
1 - 50 of 185 citations for Gentamicin Deuterated C Complex Pentaacetate Salt Contains d0 since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... decylubiquinol:cytochrome c reductase (complex III) and cytochrome c oxidase (complex IV) by spectrophotometric measurements using a SpectraMax ABS Plus microplate reader (Molecular Devices). Unsealed mitochondrial membranes were thawed on ice and diluted to 100 μg/ml in 25 mM potassium phosphate buffer (pH 7.5 ...
-
bioRxiv - Neuroscience 2024Quote: ... Cytochrome C Oxidase (COX/ complex IV) were measured spectrophotometrically in 96-well plates using Spectramax M2 (Spectramax Pro 6, Molecular Devices). Linear slopes reflecting changes in absorbance of the reporter dyes were exported to Microsoft Excel and converted into enzymatic activities using the molar extinction coefficient and dilution factor for each assay ...
-
bioRxiv - Molecular Biology 2022Quote: ... Complex II-dependent activity was measured in a plate reader (SpectraMax M2, Molecular Devices) recorded as the reduction of 2,6-dichloroindophenol (DCIP ...
-
bioRxiv - Immunology 2024Quote: ... monosodium salt) using a Spectra Max M3 Multi-Mode Microplate Reader (Molecular Devices, San Jose, CA).
-
bioRxiv - Molecular Biology 2024Quote: The UV-visible spectrum of each heme fraction was measured as a Fe3 +-heme-pyridine complex using a multi-well SpectraMax M5 plate reader (Molecular Devices, San Jose, CA). The total amount of each heme-Fe species in a sample was quantified using a heme standard curve and interpolation ...
-
bioRxiv - Neuroscience 2024Quote: ... with intensified oChIEF-Citrine (stained with GFP antibody) and C-FOS (stained with C-FOS antibody) signals were imaged with a high-content imaging system (Molecular Devices) hosting a 4x objective ...
-
bioRxiv - Neuroscience 2024Quote: ... Cells were patch-clamped at 22–23 °C and at 37 °C after 24h from transfection using a Multiclamp 700B amplifier (Molecular Devices, US) and either voltage stepped for 1s starting from a holding potential of −70 mV to voltages between −200 and +120 mV and back or voltage-clamped using in vivo somatic measured mouse hippocampal CA1-area pyramidal neuron action-potential burst waveforms ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... and Micro XLS-C High Content Imaging Systems (Molecular Devices) and processed using Fiji34 to enhance contrast and improve visualization ...
-
bioRxiv - Cell Biology 2021Quote: ... at 37°C in a fluorescent plate reader (Spectramax, Molecular Devices). Vascular hydrogen peroxide formation in aortic tissue was measured by an HPLC-based Amplex Red assay as described earlier using aortic ring segments (3 mm in length ...
-
bioRxiv - Systems Biology 2022Quote: ... or an ImageXpress Micro-Confocal (IXM-C) (Molecular Devices, San Jose, CA) high throughput microscope using a 10x objective ...
-
bioRxiv - Biochemistry 2021Quote: ... The plate was transferred to the temperature controlled (37°C) spectrophotometer (Molecular Devices FilterMax F5 spectrophotometer equipped with a 340 nm filter) ...
-
bioRxiv - Neuroscience 2021Quote: ... Recordings were performed at 24°C with a MultiClamp 700B amplifier (Molecular Devices) and a Digidata 1440 interface (Molecular Devices) ...
-
bioRxiv - Biochemistry 2023Quote: ... Fluorescence was measured at 37 °C with a SpectraMax M5 platereader (Molecular Devices) using an excitation wavelength of 440 nm and emission wavelength of 480 nm ...
-
bioRxiv - Microbiology 2024Quote: ... and results were analyzed using SoftMax Pro 5.2 rev C (Molecular Devices Corp.).
-
bioRxiv - Cell Biology 2020Quote: ... Live-cell images were acquired at 37°C using an ImageXpress system (Molecular Devices) with a 20x objective (0.45 NA) ...
-
bioRxiv - Neuroscience 2020Quote: ... Currents were recorded at 22–26°C using an Axopatch-700B amplifier (Molecular Devices), filtered at 5 kHz (low-pass 8-pole Bessel filter ...
-
bioRxiv - Neuroscience 2020Quote: ... Current-clamp recordings were made at 32 °C (MultiClamp 700B, Digidata 1440; Molecular Devices) with glass electrodes (6-10 MΩ ...
-
bioRxiv - Biophysics 2024Quote: ... at 37 °C in a Spectramax Gemini EM plate reader (Molecular Devices, Sunnyvale, CA). Absorbance was measured at 330 nm ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... The assay was performed at 25°C using a Flexstation3 microplate reader (Molecular Devices), with optical density (OD ...
-
bioRxiv - Bioengineering 2024Quote: ... the plate was transferred and imaged with an ImageXpress Micro XLS-C (Molecular Devices) confocal microscope with 10X magnification.
-
bioRxiv - Bioengineering 2024Quote: ... Reactions were incubated at 37 °C in a microplate reader (SpectraMax iD3, Molecular Devices) for 90 minutes ...
-
bioRxiv - Cancer Biology 2024Quote: ... Fluorescence was measured at 37°C with a FlexStation3 Multimode Microplate Reader (Molecular Devices) with excitation and emission wavelengths of 485 and 515 nm ...
-
bioRxiv - Cancer Biology 2022Quote: ... supplemented RPMI and incubated at 37°C in a SpectraMax M4 Microplate Reader (Molecular Devices) to record fluorescent measurements (Ex/Em = 485/535 nm ...
-
bioRxiv - Synthetic Biology 2022Quote: ... Protein expression was monitored at 37°C in a SpectraMax i3x plate reader (Molecular Devices). GFP was monitored at ex ...
-
bioRxiv - Neuroscience 2021Quote: ... Recordings were made at 22–25°C using an Axopatch 200A amplifier (Molecular Devices, USA). Voltage ramp currents were low-pass filtered at 500 Hz and digitized at 2 kHz using an NI USB-6341 (National Instruments ...
-
bioRxiv - Biophysics 2020Quote: SPR measurements were performed at 25°C using a Pioneer FE instrument (FortéBio, Molecular Devices). Ub3 and Ub4 were covalently immobilized on to two different flow cell channels on a biosensor chip by amine coupling to 456 and 721 RU ...
-
bioRxiv - Neuroscience 2024Quote: ... All electrical recordings were made at 33°C using a MultiClamp 700B amplifier (Molecular Devices). Electrical signals were filtered at 3 or 10 kHz using a Bessel filter and digitized at 10 or 20 kHz with a Digidata 1440A analog-digital interface (Molecular Devices) ...
-
bioRxiv - Cell Biology 2024Quote: ... Luminescence was monitored with 5 min interval at 37°C using SpectraMax iD5 (Molecular Devices). Data was normalized to the initial luminescence value after adding the drugs.
-
bioRxiv - Microbiology 2020Quote: ... Wells were imaged with IXM-C automated high-throughput fluorescence microscope (Molecular Devices, San Jose, USA) using a 40x objective (NA 0.95 ...
-
bioRxiv - Microbiology 2022Quote: ... NA enzymatic kinetics at 37 °C were measured by a SpectraMax M2 microplate reader (Molecular Devices) with an excitation at 365 nm and an emission at 450 nm ...
-
bioRxiv - Microbiology 2022Quote: ... NA enzymatic kinetics at 37 °C were measured by a SpectraMax M2 microplate reader (Molecular Devices) with an excitation at 365 nm and an emission at 450 nm ...
-
bioRxiv - Biochemistry 2020Quote: ... and fluorescence polarization of fluorescein was measured at 25 °C using a SpectraMax M5 (Molecular Devices).
-
bioRxiv - Biochemistry 2021Quote: SPR experiments were performed at 25 °C using a Pioneer AE optical biosensor (Molecular Devices-ForteBio) equipped with a COOH2 sensor chip (short carboxylated polysaccharide coating) ...
-
bioRxiv - Cancer Biology 2021Quote: SPR experiments were performed at 25 °C using a Pioneer AE optical biosensor (Molecular Devices-ForteBio) equipped with a PCH sensor chip and equilibrated with running buffer 10mM Hepes pH7.4 ...
-
bioRxiv - Microbiology 2023Quote: ... Images were captured using the ImageXpress Micro Confocal (IXM-C) High-Content Imaging system (Molecular Devices) with a 4x S Fluor objective lens at a resolution of 1.7 micron/pixel in the DAPI (excitation ...
-
bioRxiv - Microbiology 2023Quote: ... Incubation at 37 °C was performed in SpectraMax M5 (Molecular Devices LLC, San Jose, CA, USA) and OD600 measured every 30 minutes for 15 hours ...
-
bioRxiv - Microbiology 2020Quote: ... Plates were imaged on an IXM-C automated high-throughput fluorescence microscope (Molecular Devices, San Jose, USA) using a 40x objective (NA 0.95 ...
-
bioRxiv - Physiology 2020Quote: ... the cells were loaded for 1.5 h at 37°C with FLIPR calcium 4 dye (Molecular Devices) diluted in HBSS pH 7.4 ...
-
bioRxiv - Bioengineering 2020Quote: ... Absorbance at 290nm was measured every 30 s at 37°C using a SpectraMax M3 (Molecular Devices) plate reader.
-
bioRxiv - Microbiology 2020Quote: ... plates were imaged on an IXM-C automated high-throughput fluorescence microscope (Molecular Devices, San Jose, USA) using MetaXpress (version 6.2 Molecular Devices ...
-
bioRxiv - Biochemistry 2022Quote: ... cells were further incubated at 37°C for 10 min in the Flex Station 3 (Molecular Devices) before the assay was initiated ...
-
bioRxiv - Biophysics 2021Quote: ... Enzyme assays were performed at 37°C using a Spectramax plate spectrophotometer (Molecular Devices, Sunnyvale, CA, USA) in a 96-well plate ...
-
Novel kinome profiling technology reveals drug treatment is patient and 2D/3D model dependent in GBMbioRxiv - Cancer Biology 2022Quote: ... Images were acquired using a confocal microscope Micro XLS-C High Content Imaging Systems (Molecular Devices, US) at 4x magnification.
-
bioRxiv - Microbiology 2020Quote: ... Cultures were grown at 30°C with shaking in a SpectaMax Plus 384 microplate reader (Molecular Devices) and OD600 was monitored over time.
-
bioRxiv - Evolutionary Biology 2020Quote: ... Plates were incubated statically at 37°C in a microplate reader (SpectraMax Plus 384, Molecular Devices, USA) and OD600nm was monitored every 15 minutes for 24 hrs with 10 sec shaking events prior to each round of growth measurement.
-
bioRxiv - Biochemistry 2024Quote: ... Enzymatic activities were measured at 25°C using a SpectraMax ABC Plus plate reader spectrophotometer (Molecular Devices). In general ...
-
bioRxiv - Neuroscience 2024Quote: ... The release of fluorescent AMC was measured at 37°C using a SPECTRAmax Gemini EM (Molecular Devices) microplate reader ...
-
bioRxiv - Microbiology 2024Quote: ... Plate was incubated at 25°C for 1 h prior to reading using SpectraMax iD5 (Molecular Devices). Fluo-4 NW Calcium Assay Kit (excitation 494 nm and emission at 516 nm).
-
bioRxiv - Molecular Biology 2020Quote: For measurement of [Ca2+]c using Fluorescent Imaging Plate Reader(R) (FLIPR) Tetra® System (Molecular Devices, USA), INS-1 cells were transfected with pQCXIP ...
-
bioRxiv - Microbiology 2021Quote: ... Reactions were monitored for 60 minutes at 25 °C using the Spectra Max 250 spectrophotometer (Molecular Devices, USA). Absorbance measurement time course was used to determine the rate of hydrolysis of each β-lactam by Glby.