Labshake search
Citations for Molecular Devices :
1 - 50 of 529 citations for Acetamide N 5 bis 2 hydroxyethyl amino 2 2 chloro 4 6 dinitrophenyl azo 4 methoxyphenyl since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... both connected to a 2-way 4-port electric rotary valve (Bio-Chem Fluidics) and the pClamp 10.6 software (Molecular Devices).
-
bioRxiv - Cancer Biology 2023Quote: Cells were labelled with 2⍰μM Fura-2 QBT (Molecular Devices, UK) for 60⍰min at 37⍰°C in buffer containing (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... Analog signals were filtered at 2 kHz using the built-in 4-pole Bessel filter of a Multiclamp 700B patch-clamp amplifier (Molecular Devices) in patch mode and digitized at 20 kHz (Digidata 1440A ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... lowpass filtered (1 kHz) and sampled at 2 kHz (IKs) or 4 kHz (other currents) by the A/D converter Digidata 1440A (Molecular Devices). Signals were further filtered (4-pole Bessel filter ...
-
bioRxiv - Physiology 2023Quote: ... ventricular myocytes were isolated by combining enzymatic tissue digestion and mechanical trituration (supplement for details).32 Transmembrane voltage (Vm) was continuously recorded using a glass pipette (2-4 MΟ tip) and an Axoclamp 2B amplifier (Molecular Devices, Ca) in bridge mode (supplement for details).33 To elicit an AP ...
-
bioRxiv - Neuroscience 2020Quote: ... and filtered online at 2 kHz with the amplifiers 4-pole Bessel Filter and digitised at 20 kHz (Digidata1550B, Molecular Devices, CA, USA)
-
bioRxiv - Biophysics 2020Quote: ... The recorded signals were filtered at 2 kHz and were digitized at 4 kHz using Digidata 1440A digitizing board (Molecular Devices/Axon Instruments). Occasionally ...
-
bioRxiv - Neuroscience 2020Quote: ... with ACSF-filled glass microelectrodes (2-4 MΩ) positioned within layer II/III of the V1 using an Axopatch 200B amplifier (Molecular devices, San Jose, CA). Electric stimulation (100 μsec duration ...
-
bioRxiv - Cell Biology 2022Quote: Intracellular calcium levels were assessed using Fura-2 fluorescence ratio measurement (Fura-2 QBT kit R8197, Molecular Devices) on a FlexStation III reader with automated pipetting at the Harvard ICCB-Longwood screening facility ...
-
bioRxiv - Physiology 2022Quote: Primary podocyte cultures were subject to Fura-2 fluorescence ratio measurement (Fura-2 QBT kit R8197, Molecular Devices) using a FlexStation III reader with automated pipetting at the Harvard ICCB-Longwood screening facility in a 96-well format essentially as previously described [30 ...
-
bioRxiv - Physiology 2022Quote: ... Fura-2 QBT was from Molecular Devices. Puromycin aminonucleoside was from MedChemExpress.
-
bioRxiv - Neuroscience 2024Quote: ... filtered at 2/6/10 kHz and digitised at 10/50/500 kHz (DigiData 1400 or 1550B, Molecular Devices) using the Clampex software (Version 10.6 and 11.1).
-
bioRxiv - Neuroscience 2021Quote: ... The density and distribution of immunogold particles were quantitatively analyzed on electron micrographs using MetaMorph software (Molecular Devices; n = 2 mice). The density of SIPA1L1 on excitatory nerve terminals and dendritic spines was calculated by measuring the number of immunogold particles ...
-
bioRxiv - Cell Biology 2020Quote: ... Stacks were processed into 2-color overlays of maximal intensity 2-D projections and analyzed with MetaMorph software (Molecular Devices). Linescans for fluorescence intensity along the spindle axis were generated with the line tool set to 3-pixel width and normalized intensity plots produced in Microsoft Excel ...
-
bioRxiv - Cancer Biology 2023Quote: ... Fura-2/QBT was purchased from Molecular Devices, UK ...
-
bioRxiv - Biophysics 2024Quote: ... filtered at 2 kHz (Axopatch 200B, Molecular Devices), digitized at a sampling rate of 10 kHz (Digidata 1322A ...
-
bioRxiv - Bioengineering 2022Quote: ... Immediately we stopped the reaction by adding 50 μL of 2 N H2SO4 solution and analyzed on a microplate reader (Molecular Devices, Spectramax I3) at 450 nm wavelength ...
-
bioRxiv - Molecular Biology 2022Quote: ... filtered at 2 kHz and digitized at 5 kHz using Digidata 1440A interface with pClamp 10 software (Molecular Devices Corporation). Series resistance was typically 5–20 MΩ ...
-
bioRxiv - Cell Biology 2022Quote: Fura-2 AM was from Molecular Devices (San Jose, CA). Xestospongin C and rapamycin were from Cayman Chemical (Ann Arbor ...
-
bioRxiv - Cell Biology 2024Quote: ... and 2 iterations per stripe using MetaXpress software (Molecular Devices). After irradiation ...
-
bioRxiv - Biochemistry 2023Quote: ... using the Fura-2 QBT™ Calcium Kit (Molecular Devices). Cells were seeded (40 000 cells/well in 200 µl media ...
-
bioRxiv - Biophysics 2023Quote: ... low-pass filtered at 2 kHz (Axopatch 200B, Molecular Devices), digitized at 10 kHz (Digidata 1550B ...
-
bioRxiv - Molecular Biology 2021Quote: ... Cells were transfected in glass bottom 96 well plates (3-5 replicate wells per treatment) followed by imaging using a Zeiss Axioskop-2 microscope or an ImageXpress Micro Confocal (Molecular Devices) using a 20X objective (S Plan Fluor ...
-
bioRxiv - Neuroscience 2020Quote: ... digitized at 10–20 kHz and filtered at 2–5 kHz with a Digidata 1440A analog-to-digital converter (Molecular Devices).
-
bioRxiv - Pathology 2023Quote: ... Membrane voltage and current were low-pass filtered at 2–5 kHz and acquired at 10–20 kHz (Digidata 1550; Molecular Devices). All electrophysiological experiments were performed at room temperature (22–25 °C) ...
-
bioRxiv - Neuroscience 2023Quote: ... Presynaptic APs were evoked with 8 consecutive 2 ms pulses of 2500 pA at 5 Hz and postsynaptic potentials were recorded using a Multiclamp 700B amplifier (Molecular Devices). Postsynaptic currents were low-pass filtered at 4 kHz and digitized at 50 kHz ...
-
bioRxiv - Neuroscience 2021Quote: ... digitized at 2 kHz (Digidata 1444A, Molecular Devices, Sunnyvale, CA, USA), and acquired using Clampex 10 software (Molecular Devices).
-
bioRxiv - Physiology 2021Quote: ... Fura-2 was imaged using MetaFluor (Molecular Devices, Sunnyvale, CA USA) and standard fura-2 dual excitation filter set on IX-83 microscope (20x 0.75 NA PlanApo objective for macrophages on glass ...
-
bioRxiv - Physiology 2022Quote: ... fura-2 was imaged using MetaFluor (Molecular Devices, Sunnyvale, CA USA) and dual excitation filter set on an IX-83 microscope (10x 0.4 NA PlanApo objective ...
-
bioRxiv - Neuroscience 2022Quote: ... Recordings were filtered offline at 2 kHz using Clampfit (Molecular Devices) and analyzed using MiniAnalysis (Synaptosoft) ...
-
bioRxiv - Neuroscience 2023Quote: ... digitized at 2 kHz (Digidata 1444A, Molecular Devices, Sunnyvale, CA, USA), and acquired using Clampex 10 software (Molecular Devices).
-
bioRxiv - Immunology 2020Quote: ... His-tagged RBD of SARS-CoV or SARS-CoV-2 was loaded for 5 minutes at 3 μg/ml in KB onto anti-Penta-HIS (HIS1K) biosensors (Molecular Devices, ForteBio). Association of mAbs was performed in KB at 15 μg/ml.
-
bioRxiv - Neuroscience 2024Quote: ... and digitally sampled at 2 kHz (Molecular Devices, 1440A Digitizer and pClamp10) 54 ...
-
bioRxiv - Neuroscience 2023Quote: ... at 2-10 kHz sampling rate and Clampex 10.7 software (Molecular Devices). For voltage-clamp recordings ...
-
bioRxiv - Physiology 2024Quote: ... Currents were amplified and filtered at 2 kHz (Axopatch 200B, Molecular Devices), digitized at a sampling rate of 10 kHz (Digidata 1322A ...
-
bioRxiv - Neuroscience 2021Quote: ... filtered 2 kHz and digitized at 10 kHz with Digidata 1440A (Molecular Devices). Excitatory afferent fibers located between the NAc core and cortex dorsal to the anterior commissure were stimulated with bipolar concentric electrode (FHC ...
-
bioRxiv - Neuroscience 2022Quote: ... and data were digitally filtered at 2 kHz with ClampFit (Molecular Devices, LLC).
-
bioRxiv - Neuroscience 2024Quote: ... filtered to 2 kHz and digitized at 10 kHz (pClamp10 software, Molecular Devices). Data were analyzed using IGOR Pro (Wavemetrics ...
-
bioRxiv - Cancer Biology 2024Quote: ... The headstage amplifier was a high impedance 0.0001MU Axon HS-2 (Molecular Devices). Currents were digitized using a ITC018 A/D converter (HEKA Instruments) ...
-
bioRxiv - Molecular Biology 2021Quote: ... of fluorescent hydrolysate of Boc-Gln-Ala-Arg-MCA (7-amino-4-methylcoumarin) were read using SpectraMax M5 plate reader (Molecular Devices, San Jose, CA, USA) with excitation of 380 nm and emission of 460 nm ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... and then the firefly luminescence was measured in a luminometer (Flexstation 2, Molecular devices). On a TriLux (Perkin-Elmer ...
-
bioRxiv - Neuroscience 2021Quote: ... Larvae were dissected and sharp-electrode recordings were made from muscle 6 in abdominal segments 3 and 4 using an Axoclamp 900A amplifier (Molecular Devices). The extracellular HL3 saline contained (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Sharp-electrode and TEVC recordings were performed on muscle 6 of segments 3 and 4 with sharp glass electrodes (resistance 10-25 MΩ) using an Axoclamp 900A amplifier (Molecular Devices) and a combination of HS 9A x0.1 and HS 9A x10 headstages ...
-
bioRxiv - Neuroscience 2021Quote: ... Sharp-electrode recordings were performed on muscle 6 of segments 3 and 4 with sharp glass electrodes (resistance 10-25 MΩ) using an Axoclamp 900A amplifier (Molecular Devices). For individual NMJs ...
-
bioRxiv - Neuroscience 2022Quote: ... Data were acquired and filtered (at 5 kHz 4-pole Bessel filter) with MultiClamp 700B amplifier (Molecular Devices), digitized with Digidata 1440A (Molecular Devices ...
-
bioRxiv - Biophysics 2021Quote: ... Brightfield and fluorescent images were obtained every 2 min using MetaMorph software (Molecular Devices, USA). Composite 2D/3D cells+micropattern images were reconstructed and assembled using NIS-Elements AR and linear image parametric adjustments ...
-
bioRxiv - Neuroscience 2021Quote: ... All recordings were obtained using a 2-channel patch-clamp amplifier (Multiclamp 700B, Molecular Devices).
-
bioRxiv - Neuroscience 2020Quote: ... filtered at 2 kHz and digitized using a DigiData 1440A digitizer (Molecular Devices, Sunnyvale, CA) at a sampling rate of 10 kHz ...
-
bioRxiv - Neuroscience 2023Quote: ... filtered at 2 kHz and digitized with a Digidata 1440A A-D board (Molecular Devices). LFP and multiunit recordings were amplified by 1000-2000x ...
-
bioRxiv - Neuroscience 2022Quote: All recordings were obtained using a 2-channel patch-clamp amplifier (Multiclamp 700B, Molecular Devices) sampling at 10 kHz ...