Labshake search
Citations for Molecular Devices :
1 - 50 of 718 citations for 7 methoxy 4 piperidin 1 ium 1 ylmethyl 3 4 dihydro 2H 1 benzoxepin 5 one chloride since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: ... Whole cell recordings of L2/3 and L5 pyramidal neurons were obtained using borosilicate pipettes (4-7 MΩ) and a Multiclamp 700A amplifier (Molecular Devices). Internal solution contained (in mM) ...
-
bioRxiv - Cancer Biology 2019Quote: ... The cells were treated with various concentrations of BRAFi or/and CDK6i for 72 hr and then incubated with CellTiter 96 AQueous One Solution Reagent for 1-4 hr per manufacturer’s protocol before recording the absorbance at 490 nm on SpectraMax M2 (Molecular Devices). All experiments were performed in triplicate ...
-
bioRxiv - Biophysics 2022Quote: ... Signals were low-pass-filtered at 1 kHz and read into a computer at a digitization rate of 4 kHz with pClamp10 (Axon Instruments, Molecular Devices Corp). Depolarizing solution was applied 3 s after the start of acquisition for 6 s ...
-
bioRxiv - Molecular Biology 2019Quote: Intracellular calcium concentration of AsPC-1 cells was measured using the FLIPR-4 calcium assay reagent (Cat # R8142, Molecular Devices, San Jose, CA). In brief ...
-
bioRxiv - Neuroscience 2021Quote: ... A whole-cell voltage clamp recording was established in the selected cell using a fire-polished borosilicate pipette (4-7 MΩ, Warner Instruments) and Axon Multiclamp 700B amplifier (Molecular Devices). The intracellular pipette solution contained (in mM) ...
-
bioRxiv - Neuroscience 2019Quote: ... sampled at 4-5 kHz and saved on a PC using a Digidata 1332A (Molecular Devices) or a PCI-6070-E data acquisition board (National Instruments).
-
bioRxiv - Neuroscience 2019Quote: ... filtered at 1-5 kHz and digitalized using a MultiClamp 700B (Molecular Devices). The sampling frequency was either 20 or 40 kHz ...
-
bioRxiv - Immunology 2023Quote: ... and a FlexStation 3 plate reader using SoftMax Pro 7 (Molecular Devices).
-
bioRxiv - Neuroscience 2022Quote: ... BML-P137) for 1h and 2h before reading fluorescence (ex 365, em 440) on a plate reader (Flexstation 3, Molecular Devices,). For cathepsin B activity assessment by microscopy ...
-
bioRxiv - Neuroscience 2022Quote: ... Data were acquired and filtered (at 5 kHz 4-pole Bessel filter) with MultiClamp 700B amplifier (Molecular Devices), digitized with Digidata 1440A (Molecular Devices ...
-
bioRxiv - Molecular Biology 2021Quote: ... of fluorescent hydrolysate of Boc-Gln-Ala-Arg-MCA (7-amino-4-methylcoumarin) were read using SpectraMax M5 plate reader (Molecular Devices, San Jose, CA, USA) with excitation of 380 nm and emission of 460 nm ...
-
bioRxiv - Neuroscience 2021Quote: ... Larvae were dissected and sharp-electrode recordings were made from muscle 6 in abdominal segments 3 and 4 using an Axoclamp 900A amplifier (Molecular Devices). The extracellular HL3 saline contained (in mM) ...
-
bioRxiv - Bioengineering 2021Quote: ... EPSPs were measured in the CA1 at 10 kHz using a glass capillary microelectrode filled with aCSF (3-4 MΩ) with a MultiClamp 700B Microelectrode Amplifier (Molecular Devices), Fig ...
-
bioRxiv - Neuroscience 2021Quote: ... Sharp-electrode and TEVC recordings were performed on muscle 6 of segments 3 and 4 with sharp glass electrodes (resistance 10-25 MΩ) using an Axoclamp 900A amplifier (Molecular Devices) and a combination of HS 9A x0.1 and HS 9A x10 headstages ...
-
bioRxiv - Neuroscience 2021Quote: ... Sharp-electrode recordings were performed on muscle 6 of segments 3 and 4 with sharp glass electrodes (resistance 10-25 MΩ) using an Axoclamp 900A amplifier (Molecular Devices). For individual NMJs ...
-
bioRxiv - Cell Biology 2021Quote: ... 50 μL supernatant was mixed with 50 μL PBS (pH 7.4) and resorufin fluorescence measured in a black microtiter plate with black bottom using Flexstation 3 microtiter plate reader (Molecular Devices, San Jose ...
-
bioRxiv - Neuroscience 2020Quote: ... data along with one channel EMG recordings(400 Hz) were collected by using two multiClamp 700B amplifiers (total 4 channels, Molecular devices Inc., Union City, CA) and Clampex 10 software (Molecular Devices Inc. ...
-
bioRxiv - Biophysics 2023Quote: ... Data were filtered at 1–3 kHz and digitized at 20 kHz using pClamp software (Molecular Devices) and a Digidata 1440A digitizer (Axon Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: ... Data were acquired at 5 kHz and filtered at 1 kHz using Multiclamp 700B (Molecular Devices) or Double IPA (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2024Quote: ... λEM: 516 nm (F340/F380)) were measured every 4 s using a FlexStation 3 fluorescent microplate reader (Molecular Devices, Sunnyvale, CA, USA). During the measurements ...
-
bioRxiv - Physiology 2022Quote: ... Images were acquired at excitation of 488 nm at the same settings and the fluorescence quantified over 3-4 fields using Metamorph Software (Molecular Devices, Downington PA). For quantitation of the vascular NLRP3 and ICAM-1 ...
-
bioRxiv - Neuroscience 2023Quote: ... Recordings were made with pClamp 10.3 software using a MultiClamp 700B amplifier set with 4 kHz low-pass Bessel filter and 10 kHz digitization (Molecular Devices, Sunnydale, CA). The light beam of the same laser was directed at the preparation using an 200μm optic fiber submerged into the bath with light beam aimed at the STN ...
-
bioRxiv - Neuroscience 2020Quote: ... low-pass filtered at 4 kHz and digitized at 10Hz (current clamp) or 4 Hz (voltage clamp) (Digidata 1440A, Molecular devices, UK). Activation of Arch was obtained after illumination of the recorded area at 570 nm (pE-2 CoolLED excitation system ...
-
bioRxiv - Neuroscience 2020Quote: ... low-pass filtered at 4 kHz and digitized at 10Hz (current clamp) or 4 Hz (voltage clamp) (Digidata 1440A, Molecular devices, UK). Signals were analyzed offline (Clampfit software ...
-
bioRxiv - Synthetic Biology 2023Quote: For Figure 1 and Supplementary Figure 1 Meta-Morph® software (Molecular Devices) was used to measure the average luminal and membrane fluorescence intensity for either CFP or mCherry ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Calcium 4 dye was from Molecular devices (CA, USA). Assay buffer (physiology saline solution - PSS ...
-
bioRxiv - Neuroscience 2021Quote: ... Signals were filtered at 5 kHz with the patch-clamp amplifier (Axopatch 1-D, Molecular Devices, Sunnyvale, CA) and sampling rate was adjusted according to the kinetics of membrane current ...
-
bioRxiv - Bioengineering 2022Quote: Phase contrast images were taken every 1 to 3 days with a high content microscope (ImageXPress XLS-C; Molecular Devices) to monitor culture development.
-
bioRxiv - Biophysics 2022Quote: ... 4-pole Bessel), sampled at 5 kHz (Digidata, 1440A) and written into digital files with pClamp 10 acquisition software (Molecular Devices, Sunnyvale, CA). Clamped cells were extracellularly perfused with solutions using BPS-8SP solenoid-valve perfusion system (ALA Scientific Instruments ...
-
bioRxiv - Physiology 2022Quote: ... the supernatant was centrifuged at 900 g for 5 min under 4°C and then measured by a luminometer (SpectraMax Plus384, Molecular Devices, CA, USA).
-
bioRxiv - Neuroscience 2022Quote: Mechanically activated currents from DRG neurons 1-3 days after culturing were recorded in whole cell patch clamp mode using a MultiClamp700A amplifier and DigiData1550 (Molecular Devices) and stored directly and digitized online using pClamp software (version 10.7) ...
-
bioRxiv - Cell Biology 2021Quote: ... The 96-well plate was spun at 700 rpm for 1 min before luminescence intensity was determined on a Flexstation 3 multi-mode microplate reader (Molecular Devices).
-
bioRxiv - Microbiology 2023Quote: ... These were then incubated with 50 nM of the FITC labelled viral peptides and the plates were then read out after 1 h in FlexStation 3 (Molecular Devices) at 23°C ...
-
bioRxiv - Physiology 2021Quote: ... fluorescence was measured on a FlexStation 3 Multi-Mode Microplate Reader using SoftMax Pro 7 software (Molecular Devices) in kinetic mode in response to additions of a range of concentrations of PTH ...
-
bioRxiv - Physiology 2021Quote: ... Currents were filtered at 1 kHz and digitized at 5 kHz using an Axopatch 200B amplifier and Clampex 10.4 (Molecular Devices. Offline analysis was performed using Clampfit 10.4 ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... filtered at 1 kHz and collected at 10 kHz or using an Axopatch 1-D (Molecular Devices), filtered at 2 kHz ...
-
bioRxiv - Biophysics 2022Quote: ... The data was passed through a low-pass filter (1 kHz cutoff frequency) and stored in PC using an analog-to-digital converter (5 kHz sampling; Digidata 1550A; Molecular Devices) and pCLAMP software (Molecular Devices).
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... Currents were recorded using an Axopatch 200B amplifier (Axon Instruments) at the sample rate of 5 kHz and filtered at 1 kHz with Digitata 1332A (Molecular Devices). Once a high resistance seal was formed ...
-
bioRxiv - Biophysics 2020Quote: ... Currents were digitized at 5 kHz and low pass filtered at 1 kHz using a voltage clamp amplifier (Axopatch 200B, Molecular Devices) via a digitizer (DigiData 1440A ...
-
Interleukin 4 controls the role of macrophages in pulmonary metastatic tumor cell seeding and growthbioRxiv - Cancer Biology 2021Quote: ... Aliquots of 100 μL from the receiving and bottom chambers were taken and diluted 1:5 in DMEM before reading using a SpectraMax M5 plate reader (emission/excitation = 557/586 nm; Molecular Devices). Concentrations were calculated using a standard curve ...
-
bioRxiv - Biophysics 2021Quote: ... and currents were recorded with microelectrodes filled with 3 mM KCl (pipette resistance of < 1 MΩ), OC-725C amplifier (Warner, CT, USA) and Digidata 1550 digitizer (Molecular Devices, CA, USA) at 1 kHz with 200 Hz filtering ...
-
bioRxiv - Neuroscience 2020Quote: ... Data were digitized at 20 kHz and filtered at 1 or 3 kHz using a Digidata 1440 A system with pClamp 10.2 software (Molecular Devices, Sunnyvale, CA, USA). Only cells with access resistance of <25 MΩ were retained for analysis ...
-
bioRxiv - Neuroscience 2021Quote: ... Data were digitized at 20 kHz and filtered at 1 or 3 kHz using a Digidata 1440 A system with pClamp 10.2 software (Molecular Devices, Sunnyvale, CA, USA). Only cells with access resistance of <25 MΩ were retained for analysis ...
-
bioRxiv - Neuroscience 2022Quote: ... Signals were filtered at 200 Hz and digitized at 1 kHz with the MiniDigi 1 digitizer (Molecular Devices) for simultaneous continuous recording of DC potential ...
-
bioRxiv - Physiology 2023Quote: ... Channel currents were recorded at 1 kHz with an Axopatch 1-D amplifier (Molecular Devices Inc., Sunnyvale, CA) with a low-pass 100-Hz 8-pole Bessel filter ...
-
bioRxiv - Microbiology 2020Quote: ... Plates were fluorescently imaged using an Image Xpress Micro 4 (Molecular Devices). Images were analyzed for N stain per nuclei with the CellProfiler 3.1.9 software (Broad Institute ...
-
bioRxiv - Neuroscience 2022Quote: ... with a high content screening confocal microscope (ImageXpress Micro 4, Molecular Devices). Acquired images were transferred and stored on a Columbus (PerkinElmer ...
-
bioRxiv - Microbiology 2019Quote: ... Time-lapse imaging was performed under ambient conditions (regulated at 26 °C ± 1 °C) with a 5-minute period using automated routines (Molecular Devices, Methamorph). All reported experiments were performed once.
-
bioRxiv - Developmental Biology 2022Quote: ... Calcium Imaging: Cardiomyocytes were incubated with 1x FLIPR Calcium 4 dye (Molecular Devices) diluted in RPMI + B27 for 1.5 h at 37°C ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Cells were loaded with 20 μl per well Calcium 4 dye (Molecular Devices) reconstituted in assay buffer containing (in mM ...