Labshake search
Citations for Molecular Devices :
601 - 650 of 951 citations for 6 Heptenoic acid 7 2 cyclopropyl 4 4 fluorophenyl 3 quinolinyl 3 5 dihydroxy calcium salt 1 1 3R 5S 6E since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: ... filtered at 5 kHz and digitized at 10 kHz (Multiclamp 200B; Molecular Devices, USA). Data were acquired using Igor Pro with NIDAQ tools (Wavemetrics ...
-
bioRxiv - Neuroscience 2023Quote: ... 30 consecutive action potentials were recoded every 5 seconds using Clampex 10.6 (Molecular Devices) at 100 kHz sampling rate and filtered at 2 kHz using a MultiClamp 700B amplifier (Molecular Devices) ...
-
bioRxiv - Physiology 2023Quote: ... and digitized at 5 kHz using a Digidata 1440A digitizer (Axon CNS, Molecular Devices). 61,62 Patch pipettes were made from borosilicate glass capillary tubes ...
-
bioRxiv - Microbiology 2023Quote: ... 5% CO2 before live cell imaging was done by (ImageXpressMicro-confocal, Molecular Devices, USA) equipped with 4x S Fluor lens in two channels ...
-
bioRxiv - Neuroscience 2024Quote: ... digitized at 5 kHz and recorded using the pCLAMP 9 program (Molecular Devices, USA). The inhibitory effect of the studied compounds was analyzed at steady-state conditions using the Clampfit 10.7 program (Molecular Devices ...
-
bioRxiv - Cancer Biology 2019Quote: ... Images were captured every 2 hours on a MetaXpress Microscope (Molecular Devices). Total MCF7 nuclear count and caspase intensity was analysed using CellProfiler software.
-
bioRxiv - Neuroscience 2023Quote: ... at 2-10 kHz sampling rate and Clampex 10.7 software (Molecular Devices). For voltage-clamp recordings ...
-
bioRxiv - Neuroscience 2024Quote: ... and digitally sampled at 2 kHz (Molecular Devices, 1440A Digitizer and pClamp10) 54 ...
-
bioRxiv - Bioengineering 2022Quote: ... TNS was added to each well for a final TNS concentration of 6 μM and the fluorescence intensity was read on a plate reader (Molecular Devices, San Jose, CA) (excitation ...
-
bioRxiv - Neuroscience 2021Quote: ... low pas filtered at 1 kHz and digitized at a sampling rate of 20 kHz using Digidata 1440A (Molecular Devices). Data was recorded on a PC using pClamp 10.6 (Molecular Devices ...
-
bioRxiv - Neuroscience 2019Quote: ... Whole-cell patch-clamp recordings were made using a MultiClamp 700B amplifier (1 kHz low-pass Bessel filter and 10 kHz digitization) with pClamp 10.3 software (Molecular Devices). Voltage-clamp recordings were made using glass pipets with resistance 3-5 MOhms ...
-
bioRxiv - Neuroscience 2020Quote: ... Data were low-pass filtered at 1 kHz and digitized at 10 kHz with a digitizer (Digidata 1440; Molecular Devices). Series resistance was monitored and cells that displayed > 20% change over the duration of recording were excluded.
-
bioRxiv - Neuroscience 2021Quote: ... The digital low-pass 8-pole Bessel filter with 1 kHz 3dB cut-off was applied in Clampfit 10.7 (Molecular Devices) before the current amplitudes were determined ...
-
bioRxiv - Neuroscience 2022Quote: ... electrophysiological traces were low-pass filtered offline with an 8-pole RC filter at 1 kHz using ClampFit 10.7 (Molecular Devices). Four distinct parameters were analyzed from each choline-evoked response ...
-
bioRxiv - Genetics 2021Quote: ... Optical density data were collected every 1 hour for 72 h total using a plate reader (SpectraMAX 384, Molecular Devices). Growth kinetic parameters were calculated using the MATLAB code OCHT reported by de Mello et al ...
-
bioRxiv - Neuroscience 2021Quote: ... Mechanical stimulation in cell attached patches was performed using a high-speed pressure clamp (Besch et al., 2002) (HSPC-1, ALA Scientific) controlled by pClamp 11.1 software (Molecular Devices) as described earlier (Borbiro et al. ...
-
bioRxiv - Neuroscience 2022Quote: ... Signals were filtered with a 1 kHz bezel filter and sampled at 20 kHz using Axon pClamp10 software (Molecular Devices).
-
bioRxiv - Neuroscience 2024Quote: ... sEPSC recordings were filtered post-hoc with a 1 kHz low-pass Bessel 8-pole filter in Clampfit (Molecular Devices).
-
bioRxiv - Neuroscience 2024Quote: ... Signals were filtered with a 1 kHz bezel filter and sampled at 20 kHz using Axon pClamp10 software (Molecular Devices).
-
bioRxiv - Neuroscience 2021Quote: ... and signals were filtered at 6 kHz (Bessel filter) and digitized at 50 kHz with DigiData 1550A AD converter (Molecular Devices, San Jose, CA, USA). Data were collected and analyzed using pClamp10_7 software (Molecular Devices ...
-
bioRxiv - Neuroscience 2020Quote: Spontaneous IPSCs were identified in 5 min recording epochs using Clampfit (version 10.7, Molecular Devices) in conjunction with a template pattern search (generated from examples of sIPSC rise profiles and peak currents recorded from control cultured hippocampal neurons at the same temperature) ...
-
bioRxiv - Biochemistry 2022Quote: ... Fluorescence was measured every 5 s with a SpectraMax Gemini EM Microplate Reader (Molecular Devices) with excitation at 365 nm and emission at 407 nm ...
-
bioRxiv - Neuroscience 2021Quote: ... low-pass filtered at 5 kHz and subsequently analyzed using Clampfit 10.7 Software (Molecular Devices). Linear leak and capacitive currents were subtracted online using the P/4 protocol (20ms I-V protocol ...
-
bioRxiv - Neuroscience 2021Quote: ... filtered 2 kHz and digitized at 10 kHz with Digidata 1440A (Molecular Devices). Excitatory afferent fibers located between the NAc core and cortex dorsal to the anterior commissure were stimulated with bipolar concentric electrode (FHC ...
-
bioRxiv - Cell Biology 2019Quote: ... Fura-2-AM and a 96-well fluorescence plate reader (FlexStationII384, Molecular Devices), controlled by SOFTmax PRO software v5.4.5 ...
-
bioRxiv - Neuroscience 2022Quote: ... and data were digitally filtered at 2 kHz with ClampFit (Molecular Devices, LLC).
-
bioRxiv - Cancer Biology 2023Quote: ... The headstage amplifier was a high impedance 0.0001MU Axon HS-2 (Molecular Devices). Currents were digitized using a ITC018 A/D converter (HEKA Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: ... filtered to 2 kHz and digitized at 10 kHz (pClamp10 software, Molecular Devices). Data were analyzed using IGOR Pro (Wavemetrics ...
-
bioRxiv - Molecular Biology 2021Quote: ... by 1:20 dilution with a series of commercially available pH buffers (HYDRION) using a SpectraMax-M5 plate reader (Molecular Devices) to read out fluorescence ...
-
bioRxiv - Neuroscience 2022Quote: ... filtered at 3 kHz and digitized at 10 kHz using an EPC-10 patch-clamp amplifier with PatchMaster v2x73 software (batch 1) or MultiClamp 700B amplifier (Molecular Devices) with pClamp 10 software (batch 2) ...
-
bioRxiv - Cell Biology 2019Quote: ... Signal was low-pass filtered at 1 kHz and digitized at 10 kHz with a Digidata 1440A or 1550 (Molecular Devices). Neurons with a series resistance (Rs ...
-
bioRxiv - Developmental Biology 2020Quote: ... A voltage-clamp protocol was employed to record whole-cell currents with and without extracellular divalent cations in response to a voltage ramp from −120 to 60 mV (1 second interval) using an Axopatch 200B amplifier with pCLAMP10 software (Molecular Devices) as previously described [71 ...
-
bioRxiv - Neuroscience 2020Quote: ... The signal for all voltage-clamp recordings was filtered at 1 kHz and digitized at 10 kHz with a digitizer (Molecular Devices). For voltage-clamp recordings ...
-
bioRxiv - Biophysics 2021Quote: ... The reaction was monitored at 650 nm (turbidity due to precipitation of the product) for 1 h at 25 °C using a Spectramax i3 (Molecular Devices). Statistical analysis was performed using unpaired t-test in Prims 9.0.
-
bioRxiv - Synthetic Biology 2021Quote: ... Reactions were monitored at 340 nm for 1 hour (30s per read) using a SpectraMax Plus 384 microplate reader (Molecular Devices). NADH concentrations were determined by its extinction coefficients ...
-
bioRxiv - Microbiology 2020Quote: ... Fluorescence was measured every 60s for 1 hour after addition of virus on a FilterMax F5 multimode microplate reader (Molecular Devices). Enzyme Vmax and Km was calculated using Prism software (GraphPad).
-
bioRxiv - Microbiology 2021Quote: ... 2021.Infected cells were imaged for 72 h with 1 h intervals with a 40x objective with the ImageXpress Micro XL high-content microscope (Molecular Devices). Different parameters ...
-
bioRxiv - Microbiology 2021Quote: ... Protein concentrations were determined using the corresponding extinction coefficient at 280 nm (ExPASy, ProtParam tool) and measured in a 1 ml quartz cuvette (Hellma Analytics) using a SpectraMax M2 spectrophotometer (Molecular Devices). Proteins were long-term stored at -80 °C in 10% glycerol.
-
bioRxiv - Biophysics 2021Quote: ... The analog current signal was low-pass filtered at 1 kHz (Bessel) and digitized at 10 kHz with a Digidata 1550A digitizer (Molecular Devices). Digitized data were recorded on a computer using the software pClamp (Molecular Devices ...
-
bioRxiv - Biophysics 2022Quote: ... Data were filtered at 1-3kHz and digitized at 10kHz using a Digidata 1321A interface board and pCLAMP 10 software (Axon; Molecular Devices). Microelectrode resistances were 0.2–0.8MΩ when filled with 3 M KCl ...
-
bioRxiv - Immunology 2020Quote: ... and the reactions were stopped by adding 1 M H2SO4 before measuring absorbance at 450 nm with a Spectramax Paradigm plate reader (Molecular Devices).
-
bioRxiv - Immunology 2020Quote: ... and the reactions were stopped by adding 1 M H2SO4 before measuring absorbance at 450 nm with a Spectramax Paradigm plate reader (Molecular Devices).
-
bioRxiv - Neuroscience 2021Quote: ... The signal for voltage-clamp recordings was filtered at 1 kHz and digitized at 10 kHz with a digitizer (Molecular Devices). Stimulus generation and data acquisition were performed using pClamp (Molecular Devices).
-
bioRxiv - Neuroscience 2020Quote: ... the recorded unit was stimulated by a current pulse of 250ms long (50 % duty cycle, 1-10 nA) sent through the recording electrode by axoClamp 2B (in bridge mode; Molecular Devices). Then ...
-
bioRxiv - Neuroscience 2022Quote: ... Membrane responses to 1 s current injection between 0-700 pA (100 pA increment) were collected using an Axopatch-200B amplifier (Molecular Devices). Paired pulse optogenetic and electrical stimulation (20 Hz every 30 s ...
-
bioRxiv - Cell Biology 2022Quote: ... Data was Bessel filtered online at 1 kHz and single channel currents were analyzed offline using ClampFit analysis module of pCLAMP 10 software (Molecular Devices).
-
bioRxiv - Synthetic Biology 2020Quote: ... Purified proteins were quantified by measuring absorbance at 280 nm in a 1-cm quartz cuvette with a SpectraMax Plus384 microplate spectrophotometer (Molecular Devices), and applying Beer-Lambert’s law using extinction coefficients calculated with the ProtParam tool (https://web.expasy.org/protparam/).
-
bioRxiv - Synthetic Biology 2021Quote: ... Samples were measured via kinetic measurements (1 measurement/min) for a total of 30 minutes at 405 nm using a SpectraMax iD3 spectrophotometer (Molecular Devices).
-
bioRxiv - Microbiology 2020Quote: ... Single cell ionic currents were measured in the perforated patch clamp configuration (100 μgmL−1 amphotericin) at room temperature (21–23 °C) using an IonWorks Quattro instrument (Molecular Devices). The internal solution contained (mM) ...
-
bioRxiv - Immunology 2020Quote: ... The reaction was stopped with 1% HCl and absorbance at 450 nm was read with a SpectraMax plate reader (Molecular Devices). SoftMax Pro v5.3 was used to calculate log area-under-the-curve (AUC ...