bioRxiv - Biophysics 2022Quote: ... Signals were low-pass-filtered at 1 kHz and read into a computer at a digitization rate of 4 kHz with pClamp10 (Axon Instruments, Molecular Devices Corp). Depolarizing solution was applied 3 s after the start of acquisition for 6 s ...
-
bioRxiv - Neuroscience 2020Quote: ... Signals were recorded with a low-pass filtered at 4 kHz using a Multiclamp 700B amplifier (Molecular Devices, San Jose, CA, USA) and digitized at 20 kHz using a Digi-data 1440A interface coupled to pClamp 10.5 software (Molecular Devices ...
-
bioRxiv - Neuroscience 2020Quote: ... Signals were low-pass filtered with a 4-pole Bessel filter at 10 kHz and digitized by a DigiData 1440A (Molecular Devices Co.) at 25 kHz ...
-
bioRxiv - Biophysics 2023Quote: ... Signals were lowpass filtered at 2 kHz by a 4-pole Bessel filter and acquired at a sampling rate of 10 kHz using a Digidata 1440A (Molecular Devices, USA). Data analysis was carried out in Clampfit 10 (Molecular Devices ...
-
bioRxiv - Physiology 2023Quote: Water samples were analysed for total ammonia (NH3/4 +) colourometrically (Verdouw et al.) in triplicate using a SpectraMax 190 microplate reader (Molecular Devices, USA) as in Sackville et al ...
-
bioRxiv - Cell Biology 2022Quote: ... CM-DCF fluorescence inside cells was measured at 485 nm for excitation and 538 nm for emission with FlexStation® 3 Multi-Mode Microplate Reader (Molecular Devices, Sunnyvale, CA, USA). The amount of emitted fluorescence was correlated to the quantity of reactive oxygen species (ROS) ...
-
bioRxiv - Bioengineering 2022Quote: ... was normalized to bacterial growth using optical density measured as absorbance at 600 nm (OD600) on a plate reader (Spectra Max 3, Molecular Devices, San Jose, CA, USA). Bioluminescent signals were quantified using the 8x12 grid ROI for all wells (in vitro thermocycler induction ...
-
bioRxiv - Microbiology 2021Quote: ... The plates were then incubated for 3 min at room temperature and the luminescence was assessed using a plate luminometer (Molecular Devices, San Jose, CA, USA) with 1 sec integration time ...
-
bioRxiv - Plant Biology 2023Quote: ... The plate was cooled for 3 min at room temperature before measuring the absorbance with a SpectroMax M5 UV/Vis spectrophotometer (Molecular Devices, San Jose, CA, USA) at 630 nm ...
-
bioRxiv - Plant Biology 2024Quote: ... LUC signals were measured using the Dual-Luciferase Reporter Assay Kit (Vazyme, Nanjing, China) and analyzed on a FlexStation 3 Multi-Mode Microplate Reader (Molecular Devices, San Jose, CA, USA). Relative luciferase activity was calculated based on LUC:REN ratios.
-
bioRxiv - Neuroscience 2021Quote: ... filtered at 2 kHz and digitized at 10 kHz with a MultiClamp 700B amplifier (Molecular Devices, CA, USA) and a Digidata 1550 digitizer (Molecular Devices) ...
-
bioRxiv - Neuroscience 2020Quote: ... low-pass filtered at 2 kHz using a Digidata 1550B low noise data acquisition system (Molecular Devices, USA). For whole-cell recordings ...
-
bioRxiv - Neuroscience 2021Quote: ... Recordings were made using an Axoclamp 2 B amplifier with HS-2A x0.1 headstage (Molecular Devices, CA, USA) and on a BX51WI Olympus microscope with a 40X LUMPlanFL/IR water immersion objective (Olympus Corporation ...
-
bioRxiv - Neuroscience 2020Quote: ... Signals were filtered at 2 kHz and sampled at 10 kHz with Digidata 1322A (Molecular Devices, Sunnyvale, CA). Patch pipettes made from thin-walled borosilicate glass (outer diameter 1.5 mm ...
-
bioRxiv - Neuroscience 2020Quote: ... Data were filtered during acquisition with a low pass filter set at 2 kHz using pClamp10 (Molecular Devices). Data analysis was performed offline with Clampfit 10.2 (Molecular Devices).
-
bioRxiv - Neuroscience 2022Quote: ... Data were filtered at 2 kHz and digitized at 20 kHz using a 1440A Digidata Digitizer (Molecular Devices). Series-resistance (<20 MΩ ...
-
bioRxiv - Neuroscience 2020Quote: ... Signals were low-pass filtered at 2 kHz and sampled at 10kHz with a Digidata 1440A (Molecular Devices). All data were stored on a computer for subsequent off-line analysis ...
-
bioRxiv - Cell Biology 2024Quote: ... Changes in fluorescence due to rise in intracellular Ca 2+ were monitored using FlexStation®III (Molecular Devices). Cells were simultaneously excited at 340 nm and 380 nm and emission was recorded at 5s intervals at 510 nm to determine Ca 2+-bound and Ca2+-free Fura-2 respectively ...
-
bioRxiv - Neuroscience 2023Quote: Image analysis methods to quantify relative ubiquilin 2 and TDP-43 aggregate deposition were developed in MetaMorph v7.10.5.476 (Molecular Devices), similar to those previously described [8 ...
-
bioRxiv - Neuroscience 2022Quote: ... low-pass filtered at 2 kHz and acquired using a Digidata 1550B and pClamp 10 software (Molecular devices). All reported voltages are corrected for a −13mV liquid junction potential calculated using Liquid Junction Potential Calculator in pClamp.
-
bioRxiv - Cell Biology 2023Quote: ... and videos were recorded at 2 frames/sec with 100ms exposure time using MetaMorph acquisition software (Molecular Devices). The excitation light was passed through a cyan excitation filter (Chroma) ...
-
bioRxiv - Biophysics 2024Quote: ... HEK293 cells were recorded at room temperature (25 ± 2 °C) using an Axopatch 200B amplifier (Molecular Devices, USA) with a holding potential of -60 mV ...
-
bioRxiv - Cell Biology 2024Quote: ... were mixed with 50 µL of Component A from the Fura-2 QBT Calcium Kit (#R6193, Molecular Devices) and incubated in the dark at room temperature for 30 min ...
-
bioRxiv - Biophysics 2022Quote: ... 4-pole Bessel), sampled at 5 kHz (Digidata, 1440A) and written into digital files with pClamp 10 acquisition software (Molecular Devices, Sunnyvale, CA). Clamped cells were extracellularly perfused with solutions using BPS-8SP solenoid-valve perfusion system (ALA Scientific Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... Signals were filtered at 4–10 kHz and digitized at 10–20 kHz (Digidata 1322A and pClamp 10.2 Software; Molecular Devices, Sunnyvale, CA, USA). For analyses of K+-channel currents in NGFCs ...
-
bioRxiv - Neuroscience 2021Quote: ... amplifier and filtered online at 10 kHz with the built-in 4-pole Bessel filter and digitized at 20 kHz (Digidata1550B, Molecular Devices, CA, USA).)
-
bioRxiv - Cell Biology 2020Quote: ... incubated at 37°C for 4 h protected from light and read by a plate reader (Spectramax i3, Molecular Devices, Sunnyvale, CA, USA) at 585 nm using an excitation wavelength of 555 nm.
-
bioRxiv - Neuroscience 2021Quote: ... All recordings were filtered online at 10 kHz with the built-in 4-pole Bessel Filter and digitized at 20 kHz (Digidata1440, Molecular Devices, CA, USA). Traces were recorded in pCLAMP 9 (Molecular Devices ...
-
bioRxiv - Physiology 2022Quote: ... the supernatant was centrifuged at 900 g for 5 min under 4°C and then measured by a luminometer (SpectraMax Plus384, Molecular Devices, CA, USA).
-
bioRxiv - Physiology 2023Quote: ... Relative changes in mag-fluo-4 fluorescence from baseline (F/F0) were recorded using Clampex 9.0 software (Molecular Devices, San Jose, CA, USA). The maximum rate of electrically evoked Ca2+ release was approximated from the peak of the first derivative of the mag-fluo-4 fluorescence (dF/dt ...
-
bioRxiv - Neuroscience 2024Quote: ... Signals were filtered at 4 – 10 kHz and digitized at 10 – 20 kHz (Digidata 1322A and pClamp 10 Software; Molecular Devices, Sunnyvale, CA). For cell attached recordings pipettes were filled with our standard extracellular solution.
-
bioRxiv - Neuroscience 2020Quote: ... a 2 KHz Bessel filter was applied to the data during collection using the MultiClamp 700B (Molecular Devices, CA). For mPSC recordings ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... Data was quantified by measuring fluorescence intensity at 495 nm excitation and 517 nm emission (Flexstation 2, Molecular devices). Ter-butyl hydroperoxide was used as a positive control ...
-
bioRxiv - Neuroscience 2023Quote: ... filtered at 2 kHz and digitized at 10 kHz using a MultiClamp 700B amplifier and Digidata 1550 (Molecular Devices). Clampex version 11.4 (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... Recordings were made using an Axoclamp 2 B amplifier with HS-2A x0.1 head stage (Molecular Devices, CA, USA) on a BX51WI Olympus microscope with a 40X LUMPlanFL/IR water immersion objective (Olympus Corporation ...
-
bioRxiv - Physiology 2023Quote: ... and the data were sampled at 2 kHz and filtered at 1 kHz using pClamp 10 software (Molecular Devices). Light stimulation was applied using LEDs and a multi-LED driver through the microscope optics (DC4100 ...
-
CDK5 activity in retinal pigment epithelium contributes to gap junction dynamics during phagocytosisbioRxiv - Cell Biology 2023Quote: ... All recordings were made in current-clamp mode with a 2-channel patch-clamp amplifier (MultiClamp 700B, Molecular Devices). To analyze the input resistance ...
-
bioRxiv - Neuroscience 2023Quote: ... The data were filtered at 2 kHz and sampled at 10 kHz via a digitizer (Digidata 1440, Molecular Devices) and recorded using Clampex 10.6 software (Molecular Devices) ...
-
bioRxiv - Neuroscience 2024Quote: ... filtered at 2/6/10 kHz and digitised at 10/50/500 kHz (DigiData 1400 or 1550B, Molecular Devices) using the Clampex software (Version 10.6 and 11.1).
-
bioRxiv - Biochemistry 2024Quote: ... fluorescence was measured every 60 seconds for 2 h at 37°C using the SpectraMax Gemini XPS (Molecular Devices) at an excitation wavelength of 330 nm and an emission wavelength of 390 nm ...
-
bioRxiv - Neuroscience 2020Quote: ... All recordings swere filtered (4 kHz low-pass filter) and sampled (10 kHz) for online and later offline analysis with Multiclamp 700B amplifier (Molecular Devices, Sunnyvale, CA, USA) and Clampfit v.10.5 software (Molecular Devices).
-
bioRxiv - Neuroscience 2022Quote: ... band filtered at 0.1-400Hz) were collected (all in current-clamp mode) by using two multiClamp 700B amplifiers (total 4 channels, Molecular devices Inc., Union City, CA) and Clampex 10 software (Molecular Devices Inc. ...
-
bioRxiv - Neuroscience 2024Quote: ... Electrical signals were acquired at 20 – 50 kHz and filtered at 4 kHz using a Multiclamp 700B amplifier (Molecular Devices, San Jose, CA, USA) connected to a Digidata 1440A digitizer (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... Electrical signals were acquired at 20 – 50 kHz and filtered at 4 kHz using a Multiclamp 700B amplifier (Molecular Devices, San Jose, CA, USA) connected to a Digidata 1440A digitizer (Molecular Devices ...
-
bioRxiv - Bioengineering 2022Quote: ... Electrophysiological data were acquired using a MultiClamp 700B amplifier filtered at 4 kHz and digitized at 10 kHz using a Digidata 1440A digitizer in combination with pCLAMP 10 software (Molecular Devices, San Jose, CA). Voltage clamp recordings were limited to neurons that had a stable access resistance of <20 MΩ ...
-
bioRxiv - Biophysics 2023Quote: ... and the decrease in 485-nm excited fluorescence of Fluo-4 was monitored at 520 nm for 15 min using a FLIPR Tetra (Molecular Devices, San Jose, CA).
-
bioRxiv - Neuroscience 2020Quote: ... Signals were low-pass filtered (Bessel, 2 kHz) and collected at 10 kHz using the data acquisition software pClamp 10.5 (Molecular Devices). Optical stimulation was applied through the microscope with two LEDs (460 nm and 525 nm ...
-
bioRxiv - Neuroscience 2020Quote: ... The data were low-pass filtered at 2 kHz and digitized at 10 kHz using a Digidata 1322A (Molecular Devices) and stored using Clampex version10 ...
-
bioRxiv - Cell Biology 2021Quote: ... Fluorescence was measured after 2 hours of incubation at 37°C using the SpectraMax® iD3 microplate reader (Molecular Devices). To compare growth rates ...
-
bioRxiv - Neuroscience 2020Quote: ... Signals were low-pass filtered (Bessel, 2 kHz) and collected at 10 kHz using the data acquisition software pClamp 10.5 (Molecular Devices). Electrophysiological recordings were extracted using Clampfit (Molecular Devices ...