Labshake search
Citations for Molecular Devices :
351 - 400 of 1677 citations for Oxytocin ELISA Kit 5 Whole Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: Whole-cell voltage-clamp and current-clamp recordings were obtained using Multiclamp 700B and Clampex 10.7 software (Molecular Devices). GFP+ cells in cortical layer 2/3 in the motor cortex were targeted for patching ...
-
bioRxiv - Immunology 2019Quote: ... The absorbance at wavelength 450 nm was measured by an ELISA reader (Molecular Devices, Sunnyvale, CA, USA). Endpoint titers were calculated as the titer of dilution that gave an absorbance value (O.D. ...
-
bioRxiv - Biochemistry 2020Quote: ... Kinetic measurements were performed in 96-well plates using a plate reader (Molecular Devices SpectraMax Paradigm). Reactions contained 150 μL pNP-val and 30 μL enzyme dissolved in 50 mM TRIS-HCl buffer ...
-
bioRxiv - Molecular Biology 2020Quote: ... Protein assay plates were quantified using a SpectraMax M2e plate reader (Molecular Devices, San Jose, CA).
-
bioRxiv - Biophysics 2023Quote: ... the plate was wrapped in aluminum foil and transferred to SpectraMax M3 plate reader (Molecular Devices). Fluorescence signals were read at an excitation of 560nm and emission of 590nm.
-
bioRxiv - Physiology 2023Quote: ... the plate was read under a SpectraMax M5 plate reader (Molecular Devices, San Jose, CA, USA) with top-read chemiluminescent detection and a 500 ms integration time.
-
bioRxiv - Biophysics 2022Quote: ... A SpectraMax plate reader (Molecular Devices) was used to read the fluorescence intensity (Excitation 540 ...
-
bioRxiv - Physiology 2022Quote: ... and a plate reader (Molecular Devices). For leukocyte determinations ...
-
bioRxiv - Physiology 2022Quote: ... and a plate reader (Molecular Devices) to standardize protein loading in Laemmli 2X Concentrate sample buffer (Sigma ...
-
bioRxiv - Cancer Biology 2023Quote: ... and SpectraMax plate reader (Molecular Devices) following manufacturer’s instructions.
-
bioRxiv - Immunology 2023Quote: ... Spectramax M3 plate readers (Molecular Devices) were used to measure luminescence ...
-
bioRxiv - Systems Biology 2019Quote: ... assay plates were monitored for bacterial growth with a SPECTRAmax380 microtiter plate reader (Molecular Devices, Sunnyvale, CA) at 600 nm ...
-
bioRxiv - Immunology 2021Quote: ... was added to each well and the plate read on a Spectramax id3 plate reader (Molecular Devices) at 450 nm and 620 nm.
-
bioRxiv - Microbiology 2023Quote: ... Plates were read at an absorbance of 450 nm using a SpectraMax F5 plate reader (Molecular Devices). All experiments were done under the same conditions with each sample tested three times.
-
bioRxiv - Bioengineering 2023Quote: ... black 384-well plate in 30 μL reaction volumes in a SpectraMax M2 plate reader (Molecular Devices), quantitating FAM fluorescence using 490 nm excitation and 520 nm emission ...
-
bioRxiv - Physiology 2022Quote: All whole-cell recordings were obtained utilizing the Axon Axopatch 200B amplifier and Digidata 1440B data acquisition system (Molecular Devices), as previously described.16 Cell capacitance was recorded after adjusting for transients’ post-membrane rupture ...
-
bioRxiv - Neuroscience 2021Quote: Whole-cell patch clamp recordings were carried out at room temperature using a Multiclamp 700B amplifier (Molecular Devices, CA, USA). The resistances of borosilicate glass electrodes were measured ranging from 3 to 5 MΩ ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell recordings in current-clamp mode were made with a Multiclamp 700B amplifier and a Digidata 1440A (Molecular Devices). The electrodes (3−5 MΩ ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole-cell voltage-clamp recordings were made at room temperature using an Axopatch 200B amplifier (Molecular Devices, Sunnyvale, CA, USA). Patch pipettes were pulled from borosilicate glass capillaries (Harvard Apparatus Ltd. ...
-
bioRxiv - Neuroscience 2020Quote: Neuronal cultures were recorded in patch-clamp whole-cell configuration using Axopatch 200B amplifier (Molecular Devices, San Jose, CA, U.S.A.) with pClamp software 10.6 ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell voltage-clamp recording techniques were used to measure synaptic responses using a Multiclamp 700B (Molecular Devices, Sunnyvale, CA). Signals were collected and stored using a Digidata 1440A converter and pCLAMP 10.2 software (Molecular Devices ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Whole-cell recordings from substantia nigra pars compacta neurons were performed with a Multiclamp 700B amplifier (Molecular Devices, Sunnyvale, CA) in voltage-clamp mode (Vhold = -60mV ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole-cell current and voltage-clamp recordings were conducted at 32-23°C with an Axopatch-200B amplifier (Molecular Devices) using 5-8 MOhm glass electrodes filled with an internal solution containing (in mM ...
-
bioRxiv - Neuroscience 2021Quote: Whole-cell recordings in autaptic neurons were performed on an Olympus IX73 microscope using a Multiclamp 700B amplifier (Molecular Devices) under control of Clampex 10 (Molecular Devices) ...
-
bioRxiv - Neuroscience 2022Quote: ... MSNs were voltage-clamped in whole-cell configuration at −60 mV using Axopatch 200B amplifiers (Molecular Devices, San Jose, CA), and signals were acquired with Axograph X at 5 kHz and filtered to 2 kHz or acquired with LabChart (ADInstruments ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings were obtained with Multiclamp 700B amplifiers and pCLAMP 10 software (Molecular Devices; Sunnyvale, California, USA) and was guided using an Olympus BX51 Microscope equipped with both transmitted and epifluorescence light sources (Olympus Corporation ...
-
bioRxiv - Neuroscience 2023Quote: ... and targeted for single or dual whole-cell recordings using a MultiClamp 700B amplifier (Molecular Devices, San-Jose, CA, USA). Upon break-in ...
-
bioRxiv - Pathology 2023Quote: ... Whole-cell recordings (for OHCs and HEK293T cells) were performed at room temperature using the Axopatch 200B amplifier (Molecular Devices) with a 10 kHz low-pass filter ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell recordings were performed using a software-controlled MultiClamp 700B amplifier and a Digidata 1440A digitizer (Molecular Devices, USA). Recording pipettes were pulled from borosilicate glass capillaries (WPI ...
-
bioRxiv - Neuroscience 2024Quote: ... Whole-cell voltage-clamp recordings were obtained from pyramidal cells in the IL using Axon Multiclamp 700B amplifiers (Molecular Devices). Data were acquired and analyzed using AxoGraph X (AxoGraph Scientific) ...
-
bioRxiv - Physiology 2024Quote: Whole-cell potassium currents in HEK293T cells and β-cells were recorded using a Multiclamp 700B amplifier (Molecular Devices, USA). The extracellular solution contained (in mM) ...
-
bioRxiv - Physiology 2024Quote: ... Membrane potentials were recorded under current-clamp conditions in the whole-cell configuration using a MultiClamp 700B amplifier (Molecular Devices). Acquisition was done using the Clampex 10 software driving an Axon Digidata 1550 (Molecular Devices) ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch-clamp recordings were made using a Multiclamp 700B amplifier and pCLAMP 10 software (Molecular Devices; Sunnyvale, CA). Signals were digitized at 20–40 kHz and filtered at 10 kHz by Digidata 1440A (Molecular Devices) ...
-
bioRxiv - Immunology 2021Quote: ... ELISA data was acquired on a SpectraMax M5 Multi-Mode Microplate Reader (Molecular Devices, San Jose, CA, USA).
-
bioRxiv - Cancer Biology 2022Quote: Absorbance values of the ELISA were measured at 450 nm using a SpectraMax M5 microplate reader (Molecular Devices). To calculate interferon-β titers ...
-
bioRxiv - Microbiology 2020Quote: ... Plates were read at OD 450 nm with a SpectraMax plus plate reader (Molecular Devices, Sunnyvale, CA, USA) and data analyzed with SoftMax software ...
-
bioRxiv - Microbiology 2020Quote: ... Plates were read at OD 450 nm with a SpectraMax Plus plate reader (Molecular Devices, Sunnyvale, CA, USA) and data analyzed with SoftMax software ...
-
bioRxiv - Biophysics 2021Quote: ... Fluorescence spectra of each assay plate were also recorded with a SpectraMax Gemini EM plate reader (Molecular Devices). FLT waveforms for each well of 1536-well plates were fit based on a one-exponential decay function using least-squares minimization global-analysis software ...
-
bioRxiv - Immunology 2021Quote: ... Plates were read at OD 450 nm with a SpectraMax Plus plate reader (Molecular Devices, Sunnyvale, CA, USA) and data analyzed with SoftMax Pro 6.5.1 GxP software ...
-
bioRxiv - Cell Biology 2021Quote: ... The plate was read in a fluorescence plate reader (FLIPR® Tetra System or SpectraMax i3; Molecular Devices) at 37°C ...
-
bioRxiv - Immunology 2021Quote: ... Plates were read at OD 450 nm with a SpectraMax plus plate reader (Molecular Devices, Sunnyvale, CA, USA) and data analyzed with SoftMax Pro 6.5.1 GxP software ...
-
bioRxiv - Immunology 2021Quote: ... Plates were read at OD 450 nm with a SpectraMax Plus plate reader (Molecular Devices, Sunnyvale, CA, USA). EC50 values and endpoint titer values were calculated by 4-parameter fitting using SoftMax Pro 6.5.1 GxP software ...
-
bioRxiv - Immunology 2021Quote: ... Plates were read at OD 450 nm with a SpectraMax Plus plate reader (Molecular Devices, Sunnyvale, CA, USA) and data analyzed with SoftMax Pro 6.5.1 GxP software ...
-
bioRxiv - Immunology 2021Quote: ... Plates were read at OD 450 nm with a SpectraMax Plus plate reader (Molecular Devices, Sunnyvale, CA, USA). EC50 values were calculated by 4-parameter fitting using SoftMax Pro 6.5.1 GxP software ...
-
bioRxiv - Immunology 2020Quote: ... Plates were read at OD 450 nm with a SpectraMax plus plate reader (Molecular Devices, Sunnyvale, CA, USA) and data analyzed with SoftMax software ...
-
bioRxiv - Neuroscience 2022Quote: ... The plate was incubated for 1 h at RT and read on an HTRF plate reader (Molecular Devices).
-
bioRxiv - Neuroscience 2022Quote: ... The plate was read within 1 hour after cell lysis using a SpectraMax plate reader (Molecular Devices, CA). Samples were excited at 480nm ...
-
bioRxiv - Molecular Biology 2022Quote: ... according to the manufacturer’s instructions and the plate absorbance was read in the SpectraMAX plate reader (Molecular Devices) at 562 nm ...
-
bioRxiv - Cell Biology 2023Quote: ... Supernatants were transferred to a 96-well plate and absorbance was measured using a plate reader (Molecular Devices) at OD = 490 nm.
-
bioRxiv - Cancer Biology 2019Quote: ... with a SpectraMax plate reader (Molecular Devices) following the manufacture’s protocol ...