Labshake search
Citations for Molecular Devices :
151 - 200 of 1657 citations for Corticosterone ELISA Kit 1 Whole Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2021Quote: ... The reaction was stopped by the addition of 1% SDS per well and the absorbance (A) was measured at 405 nm (A405) using an ELISA reader Spectramax (Molecular Devices, San Jose, CA)) within 30 min of stopping the reaction. ...
-
bioRxiv - Immunology 2023Quote: ... Plates were read using a VERSAmax plate reader (Molecular Devices) and analyzed using MyAssays.com ...
-
bioRxiv - Immunology 2021Quote: ... OD450 was measured using the SpectraMax M5 ELISA reader (Molecular Devices, Catalog # M5) and read at OD450 nm or expressed as Log OD50 ...
-
bioRxiv - Neuroscience 2023Quote: ... ELISA results were analyzed using SoftMax Pro software (Molecular Devices, San Jose, CA).
-
bioRxiv - Immunology 2023Quote: ... Absorbance at 450 nm was determined using an ELISA reader (Molecular Devices SPECTRAmax).
-
bioRxiv - Immunology 2023Quote: ... ELISA results were read in a SpectraMax iD5 microplate reader (Molecular devices, USA) at an absorbance of 450nm and a reference wavelength of 620nm.
-
bioRxiv - Immunology 2024Quote: ... Absorbance at 450 nm was determined using an ELISA reader (Molecular Devices SPECTRAmax).
-
bioRxiv - Neuroscience 2019Quote: ... The whole-cell recording data was acquired using the PClamp 10.6 software (Molecular devices, CA). All recordings were performed in current-clamp mode ...
-
bioRxiv - Neuroscience 2019Quote: ... Whole-cell voltage clamp recordings were acquired using an Axopatch 200B amplifier (Molecular Devices, USA). An M-current blocker ...
-
bioRxiv - Physiology 2019Quote: ... Whole-cell currents were acquired using an Multiclamp 700B amplifier (Molecular Devices, Union City, CA) and Windows PC running pClamp 11 software (Molecular Devices) ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole-cell patch-clamp recordings were performed in current clamp mode (Molecular Devices, Multiclamp 700B) and acquired at 20 kHz with custom software (MATLAB) ...
-
bioRxiv - Neuroscience 2022Quote: ... Current and voltage-clamp whole-cell recordings were performed using Axoclamp 700B amplifier (Molecular Devices) and ITC-1600 digitizer (Heka Electronik) ...
-
bioRxiv - Neuroscience 2020Quote: ... and whole-cell patch-clamp recordings were made using an Axopatch 200B amplifier (Molecular Devices). Recordings were carried out in the lateral portion of the posterior VTA.
-
bioRxiv - Neuroscience 2020Quote: Whole-cell patch clamp data were analyzed offline using the Clampfit 10.5 (Molecular Devices, USA) and Mini Analysis program (Synaptosoft Inc. ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell patch-clamp recordings were performed with a Multiclamp 700B (Molecular Devices, CA, USA) amplifier ...
-
bioRxiv - Developmental Biology 2019Quote: ... Whole cell electrophysiology recordings where made at room temperature with an Axopatch 200B (Molecular Devices) from borosilicate patch electrodes ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole-cell recordings of IPSCs were made using a MultiClamp 700B amplifier (Molecular devices, UK) in CA1 pyramidal neurons voltage clamped at −70mV with a pipette (3-5 MΩ ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings were performed with patch-clamp amplifiers (MultiClamp 700B; Molecular Devices) under the control of pClamp 11 software (Molecular Devices) ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell recordings were made with a multiclamp 700B amplifier (Molecular Devices, San Jose, CA) digitized at 20 KHz (National Instruments BNC-2090A ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch clamp recordings were performed with a Multiclamp 700B amplifier (Molecular Devices, USA) and acquired with WinWCP 4.2.1 freeware (John Dempster ...
-
bioRxiv - Cell Biology 2023Quote: All results were recorded in whole-cell configurations using an Axopatch 200B amplifier (Molecular Devices) and the pClamp 10 software package (Molecular Devices) ...
-
bioRxiv - Neuroscience 2023Quote: ... whole cell voltage and current signals were recorded with an Axopatch 700B amplifier (Molecular Devices). Signals were low pass filtered (5 kHz ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch-clamp (whole-cell) recordings were made using a Multiclamp 700A (Molecular Devices, Sannyvale, CA) with a basic intracellular solution containing (in mM) ...
-
bioRxiv - Cell Biology 2023Quote: ... The whole microscopy system was controlled by the MetaMorph advanced acquisition software (Molecular Devices, USA).
-
bioRxiv - Biophysics 2023Quote: Whole-cell recordings were performed at room temperature using the Axopatch 200B amplifier (Molecular Devices) with a 10 kHz low-pass filter ...
-
bioRxiv - Neuroscience 2023Quote: Whole cell and cell attached recordings were made using an Axopatch 200B Amplifier (Molecular Devices). Data were acquired with Axograph X (Axograph Scientific ...
-
bioRxiv - Pathology 2024Quote: Whole-cell recordings were performed at room temperature using the Axopatch 200B amplifier (Molecular Devices) with a 10 kHz low-pass filter ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell recordings were conducted on Axopatch-200B amplifier (Molecular Devices, San Jose, CA, USA) using 5-8 MOhm glass electrodes filled with an internal solution containing (in mM ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell patch-clamp recordings were performed using an Axopatch 200B amplifier (Molecular Devices, USA) at a holding membrane potential of -60 mV and +40 mV in the human embryonic kidney 293 (HEK293 ...
-
bioRxiv - Immunology 2021Quote: ... and plates were read using a SectraMaxiD3 plate reader (Molecular Devices) for absorbance at 405 nm.
-
bioRxiv - Neuroscience 2021Quote: ... Plates were analyzed using a Versa Max Plate Reader (Molecular Devices) at OD 450 nm.
-
bioRxiv - Neuroscience 2023Quote: ... Plates were scanned using a SpectraMax M2 plate reader (Molecular Devices).
-
bioRxiv - Microbiology 2020Quote: ... and absorption was measured at 595 nm in an ELISA reader (Spectramax, Molecular Devices).
-
bioRxiv - Microbiology 2021Quote: ... The reading was performed on the ELISA reader (FlexStation® 3, Molecular Devices, USA) at a wavelength of 540 nm ...
-
bioRxiv - Physiology 2020Quote: ... employing an ELISA microplate reader (SpectraMax M2, Molecular Devices LLC, San Jose, CA, USA) at 562 nm absorbance.
-
bioRxiv - Microbiology 2021Quote: ... Yolk triglyceride and cholesterol were determined by ELISA (SMP500-15859-SBRE, Molecular Devices, America) using commercial kits ...
-
bioRxiv - Immunology 2023Quote: ... and then read at 450nm using an ELISA microplate reader (Molecular Devices SpectraMax iD3).
-
bioRxiv - Neuroscience 2021Quote: Whole cell patch clamp recordings were obtained using a Multiclamp 700B amplifier (Molecular Devices, California, USA), low pas filtered at 1 kHz and digitized at a sampling rate of 20 kHz using Digidata 1440A (Molecular Devices) ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole-cell recordings from CA1 pyramidal cells were made with a Multiclamp 700B amplifier (Molecular Devices) under the control of Ephus software written in Matlab (The MathWorks)62 ...
-
bioRxiv - Neuroscience 2019Quote: ... Whole cell recordings were made using a Multiclamp 700B amplifier (Molecular Devices, Union City, CA, USA), filtered at 4 kHz ...
-
bioRxiv - Neuroscience 2019Quote: Astrocytes were recorded in whole-cell voltage-clamp mode using Multiclamp 700B amplifier (Molecular Devices, USA). Borosilicate pipettes (3 - 5 MΩ ...
-
bioRxiv - Neuroscience 2019Quote: ... All whole-cell patch recordings were performed with a Multiclamp 700B patch-clamp amplifier (Molecular Devices). Bipolar cell intracellular solution contained (in mM) ...
-
bioRxiv - Pathology 2019Quote: ... Whole-cell patch-clamp recordings were performed at room temperature using a Multiclamp amplifier (Molecular Devices). The signal was sampled at 20 kHz and stored for offline analysis ...
-
bioRxiv - Cell Biology 2021Quote: iPodo whole-cell patch clamp was performed using an Axopatch 700B and Digidata 1550A (Molecular Devices). Bath solution contained (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell voltage clamp recordings were performed using a MultiClamp 700B (Molecular Devices, San Jose CA), WinLTP software (WinLTP Ltd ...
-
bioRxiv - Neuroscience 2020Quote: ... Membrane currents were recorded in the whole-cell configuration using a MultiClamp 700B amplifier (Molecular Devices). Acquisition and command voltage were done using the Clampex 10 software driving an Axon Digidata 1550 (Molecular Devices) ...
-
bioRxiv - Neuroscience 2019Quote: ... Whole-cell voltage or current-clamp recordings were made with a MultiClamp 700B amplifier (Molecular Devices), filtered with a low pass Bessel filter at 10 kHz and digitized at 20-50 kHz (Digidata 1440A ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole-cell recording was made in current clamp mode using Axon Multiclamp 700B amplifiers (Molecular Devices). Data was acquired using pClamp v.10 software (Molecular Devices) ...
-
bioRxiv - Neuroscience 2019Quote: ... Whole-cell current- and voltage-clamp recordings were made with a Multiclamp 700B amplifier (Molecular Devices).
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell currents were recorded on Axopatch-200B amplifier using pClamp 9 or 10 (Molecular Devices). The cells were held at −90 mV ...