Labshake search
Citations for Molecular Devices :
151 - 200 of 374 citations for 2 Triisopropylsilyl Oxazole 5 Carbaldehyde since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Systems Biology 2022Quote: ... and the EtBr accumulation was measured by measuring the fluorescence in a microplate reader (spectramax multimode M 5, Molecular devices) at 37°C using 530 nm excitation wavelength and 585 nm as the emission wavelength ...
-
bioRxiv - Biochemistry 2023Quote: ... Data were sampled at 10 kHz and filtered at 5 kHz using a Digidata 1550A device controlled by pCLAMP 10.5 (Molecular Devices). Capacitance transients and leak currents were removed by subtracting a scaled control trace utilizing a P/4 protocol.
-
bioRxiv - Cancer Biology 2023Quote: ... Whole-cell currents were filtered at 5 kHz and digitized at 10 kHz using the software pCLAMP 10 (Molecular Devices). Micropipettes were pulled from Corning 8161 capillary glass tubes (Warner Instruments ...
-
bioRxiv - Neuroscience 2023Quote: Spontaneous IPSCs were detected and analyzed for 5-minute epochs during baseline and following drug exposure (Clampfit 11.1, Molecular Devices). For electrically-evoked IPSCs ...
-
bioRxiv - Neuroscience 2024Quote: ... Continuous current traces of 5-min duration (recorded at least 5 min after achieving whole-cell configuration) were acquired and analyzed with Clampfit 10.7 (Molecular Devices). The frequency and amplitude of recorded sIPSCs were quantified.
-
bioRxiv - Neuroscience 2024Quote: ... We detected the evoked qEPSCs 0.5-1.5s after the light onset and calculated the average number of qEPSCs from 5 sweeps using Clampfit 11 (Molecular Devices).
-
bioRxiv - Neuroscience 2021Quote: ... filtered at 2 kHz and digitized at 10 kHz with a MultiClamp 700B amplifier (Molecular Devices, CA, USA) and a Digidata 1550 digitizer (Molecular Devices) ...
-
bioRxiv - Neuroscience 2020Quote: ... low-pass filtered at 2 kHz using a Digidata 1550B low noise data acquisition system (Molecular Devices, USA). For whole-cell recordings ...
-
bioRxiv - Neuroscience 2021Quote: ... Recordings were made using an Axoclamp 2 B amplifier with HS-2A x0.1 headstage (Molecular Devices, CA, USA) and on a BX51WI Olympus microscope with a 40X LUMPlanFL/IR water immersion objective (Olympus Corporation ...
-
bioRxiv - Neuroscience 2020Quote: ... Signals were filtered at 2 kHz and sampled at 10 kHz with Digidata 1322A (Molecular Devices, Sunnyvale, CA). Patch pipettes made from thin-walled borosilicate glass (outer diameter 1.5 mm ...
-
bioRxiv - Neuroscience 2020Quote: ... Data acquisition (filtered at 2–3 kHz and digitized at 15 kHz; Digidata 1440A, Molecular Devices, CA, USA) was performed using the Axopatch 200B amplifier and the Clampex 10.6 software (Molecular Devices) ...
-
bioRxiv - Neuroscience 2020Quote: ... Data were filtered during acquisition with a low pass filter set at 2 kHz using pClamp10 (Molecular Devices). Data analysis was performed offline with Clampfit 10.2 (Molecular Devices).
-
bioRxiv - Neuroscience 2022Quote: ... Data were filtered at 2 kHz and digitized at 20 kHz using a 1440A Digidata Digitizer (Molecular Devices). Series-resistance (<20 MΩ ...
-
bioRxiv - Neuroscience 2020Quote: ... Signals were low-pass filtered at 2 kHz and sampled at 10kHz with a Digidata 1440A (Molecular Devices). All data were stored on a computer for subsequent off-line analysis ...
-
bioRxiv - Animal Behavior and Cognition 2021Quote: ... Data acquisition (filtered at 2–3 kHz and digitized at 15 kHz; Digidata 1440A, Molecular Devices, CA, USA) was performed using the Axopatch 200B amplifier and the Clampex 10.6 software (Molecular Devices) ...
-
bioRxiv - Neuroscience 2022Quote: ... low-pass filtered at 2 kHz and acquired using a Digidata 1550B and pClamp 10 software (Molecular devices). All reported voltages are corrected for a −13mV liquid junction potential calculated using Liquid Junction Potential Calculator in pClamp.
-
bioRxiv - Neuroscience 2023Quote: Image analysis methods to quantify relative ubiquilin 2 and TDP-43 aggregate deposition were developed in MetaMorph v7.10.5.476 (Molecular Devices), similar to those previously described [8 ...
-
bioRxiv - Cell Biology 2024Quote: ... Changes in fluorescence due to rise in intracellular Ca 2+ were monitored using FlexStation®III (Molecular Devices). Cells were simultaneously excited at 340 nm and 380 nm and emission was recorded at 5s intervals at 510 nm to determine Ca 2+-bound and Ca2+-free Fura-2 respectively ...
-
bioRxiv - Cell Biology 2023Quote: ... and videos were recorded at 2 frames/sec with 100ms exposure time using MetaMorph acquisition software (Molecular Devices). The excitation light was passed through a cyan excitation filter (Chroma) ...
-
bioRxiv - Biophysics 2024Quote: ... HEK293 cells were recorded at room temperature (25 ± 2 °C) using an Axopatch 200B amplifier (Molecular Devices, USA) with a holding potential of -60 mV ...
-
bioRxiv - Cell Biology 2024Quote: ... were mixed with 50 µL of Component A from the Fura-2 QBT Calcium Kit (#R6193, Molecular Devices) and incubated in the dark at room temperature for 30 min ...
-
bioRxiv - Neuroscience 2020Quote: Membrane currents from voltage-clamp electrophysiology experiments were amplified and low-pass filtered at 5 kHz using a MultiClamp 700B amplifier (Molecular Devices), digitized at 10 kHz and acquired using a Digidata 1550A digitizer (Molecular Devices) ...
-
bioRxiv - Cell Biology 2020Quote: ... were acquired at 20–100 kHz and filtered at 5–10 kHz (low-pass Bessel filter) using a computer attached to a DigiData 1200 (Molecular Devices). Patch pipettes were pulled from borosilicate glass (Kimble® Queretaro ...
-
bioRxiv - Cancer Biology 2022Quote: ... Blood samples were centrifuged to obtain plasma (300g for 5 min at room temperature) and OG fluorescence was read with a plate reader (FlexStation II Molecular Devices) at 480nm excitation/520nm emission.
-
bioRxiv - Neuroscience 2021Quote: ... 5-minute traces were recorded and mEPSCs events were detected using a template matching built-in feature in Clampfit (Molecular devices).
-
bioRxiv - Biophysics 2022Quote: ... The data was passed through a low-pass filter (1 kHz cutoff frequency) and stored in PC using an analog-to-digital converter (5 kHz sampling; Digidata 1550A; Molecular Devices) and pCLAMP software (Molecular Devices).
-
bioRxiv - Immunology 2021Quote: ... cells were lysed using a previously described assay buffer (109) and shaken for 5 min prior to quantitation of luciferase expression using a Spectramax L luminometer (Molecular Devices). Percent neutralization was determined by subtracting background luminescence measured from cells control wells (cells only ...
-
bioRxiv - Plant Biology 2020Quote: ... using 10mM EDTA for 15 min while shaking followed by the addition of CaCl2 to a final concentration of 5 or 50mM after which the optical density at 600nm (Versamax, Molecular Devices) was measured over time.
-
bioRxiv - Biochemistry 2021Quote: ... centrifugal drying (1,000 rpm for 5 min at RT) was performed and the arrays scanned using a GenePix scanner (4100A by Molecular Devices). Microarray images were gridded and quantitated using GenePix Pro (v7 ...
-
bioRxiv - Systems Biology 2020Quote: ... DNA concentrations were measured using the SpectraMax Microplate Reader integrated on the robot (5 μl DNA samples on the SpectraDrop Micro-Volume Microplates, Molecular Devices).
-
bioRxiv - Cell Biology 2020Quote: ... The data from whole-cell patch-clamp recordings were acquired at 10 kHz and filtered at 5 kHz for analysis (Axopatch 200B amplifier with pCLAMP software, Molecular Devices). Membrane potential was clamped at 0 or −60 mV and voltage ramp-pulses from −100 to +100 mV (300 ms ...
-
bioRxiv - Biophysics 2021Quote: ... The measured membrane currents were low-pass filtered at 5 kHz and digitized at 10 kHz using a Digidata 1440A device (Molecular Devices). Data analysis was performed with Clampfit 10.2 (Molecular Devices ...
-
bioRxiv - Neuroscience 2022Quote: ... live imaging is performed with a live cell chamber-equipped to maintain 5% CO2 and 37 degrees on an IXM High throughput microscope (Molecular Devices) using a 10x objective ...
-
bioRxiv - Microbiology 2021Quote: ... aureus grown in DMEM supplemented with 10% FBS and 1% L-Glu at pH 5.5 for three days were washed with PBS before measuring luminescence on a SpectraMax i3 MiniMax 300 plate reader (Molecular Devices) in white 96-well flat bottom plates ...
-
bioRxiv - Neuroscience 2020Quote: ... Z-stacks (200-250 slices, 5 μm step) of explants were then acquired using the ImageXpress high content imaging system (Molecular Devices). 2-D projections were used for analysis of positively labelled nuclei with the Custom Module Editor (image analysis pipeline described in detail in supplementary data (fig ...
-
bioRxiv - Neuroscience 2021Quote: ... Extracellular recordings were made with a pipette (tip diameter, 5–10 μm) connected to the headstage of a patch-clamp amplifier (Multiclamp 700A, Molecular Devices). Gentle suction was applied to draw the soma and a small portion of neurite into the pipette ...
-
bioRxiv - Biochemistry 2020Quote: ... Conversion of GTP to the product 2,5-diamino-6-β-ribosyl-4(3H)-pyrimidinone-5’-phosphate (DARPP) was monitored by measuring absorbance at 310 nm for 5 min using a microplate reader (Spectramax M5, Molecular Devices). The reaction rate was calculated using the extinction coefficient for DARPP (7.43 cm-1 mM-1 ...
-
bioRxiv - Immunology 2022Quote: ... The optical density was measured at 450 nm with SpectraMax ID3 microplate reader with SoftMax Pro Version 5 (both from Molecular Devices) and either titers or concentrations were calculated using as cutoff three times the optical density of the background.
-
bioRxiv - Biophysics 2020Quote: ... Currents were digitized at 5 kHz and low pass filtered at 1 kHz using a voltage clamp amplifier (Axopatch 200B, Molecular Devices) via a digitizer (DigiData 1440A ...
-
bioRxiv - Immunology 2020Quote: ... and kept at 37°C with 5% (v/v) CO2 incubator and Sytox Green fluorescence intensities were detected by a SpectraMax M2 fluorescence microplate reader (Molecular Devices) every 30 min for 180 min ...
-
bioRxiv - Neuroscience 2020Quote: ... Data were collected with a modified electrochemical headstage (CB-7B/EC retrofit with 5 MΩ resistor) using a Multiclamp 700B amplifier (Molecular Devices) after being low-pass filtered at 10 kHz and digitized at 100 kHz using custom-written software in Igor Pro running mafPC (courtesy of M.A ...
-
bioRxiv - Immunology 2021Quote: ... and the excitation spectra (with λem = 555 nm) were recorded after 5 min of incubation at 25°C using a SpectraMax iD5 plate reader (Molecular Devices). The polybuffer solution consisted of sodium acetate (10 mM) ...
-
bioRxiv - Biochemistry 2021Quote: ... All recordings were voltage-clamped at −60 mV and data collected at 5 kHz using an Axopatch 200B amplifier and Digidata 1440A (Molecular Devices) with Axopatch software ...
-
Interleukin 4 controls the role of macrophages in pulmonary metastatic tumor cell seeding and growthbioRxiv - Cancer Biology 2021Quote: ... Aliquots of 100 μL from the receiving and bottom chambers were taken and diluted 1:5 in DMEM before reading using a SpectraMax M5 plate reader (emission/excitation = 557/586 nm; Molecular Devices). Concentrations were calculated using a standard curve ...
-
α-catenin links integrin adhesions to F-actin to regulate ECM mechanosensing and rigidity-dependencebioRxiv - Cell Biology 2021Quote: ... The cells where then imaged at 10X magnification every 15 minutes at 37°C and 5% CO2 using an ImageXpress micro system (Molecular Devices). Quantifications were performed using the Manual Tracking plugin in FIJI and the Chemotaxis and Migration Tool (ibidi ...
-
bioRxiv - Immunology 2022Quote: ... following incubation (2 hrs 37 °C/5% CO2) fluorescence of the bottom well was determined using a FlexStation 3 fluorescent plate reader (Molecular Devices). Data were expressed and plotted relative to vehicle controls.
-
bioRxiv - Microbiology 2022Quote: ... OD600 was measured every 5 minutes at 37 °C for 20 hours (shaking at 200 rpm) in a SpectraMax Plus 384 Microplate reader (Molecular Devices).
-
bioRxiv - Plant Biology 2022Quote: ... The reaction velocity was measured spectrophotometrically at 450 nm for 5 min using a SpectraMax M5e plate reader (Molecular Devices, USA). Experiments were performed in triplicates and velocities were reported as means ± SD.
-
bioRxiv - Neuroscience 2022Quote: ... Data were acquired at 10-20 kHz and low-pass filtered at 5 kHz (Bessel) with a Digidata 1550B (Molecular Devices) using the Clampex 11.2 acquisition software (pClamp ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings (electrode resistance 5-9 MΩ) were performed at room temperature using a Multiclamp 700B amplifier (Molecular Devices). Layer 2/3 chandelier cells were patched in current-clamp configuration using potassium-based internal solution (in mM ...