Labshake search
Citations for Molecular Devices :
1801 - 1850 of 1934 citations for Prostaglandin E2 PGE2 Multi Format ELISA Kit 1 Whole Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2020Quote: ... The cAMP content in the lysates was determined according to the manufacturer’s instruction by catch point cAMP immunoassay kit (Molecular Devices) [20].
-
bioRxiv - Pharmacology and Toxicology 2023Quote: Changes in membrane potential were measured using a proprietary membrane potential assay kit (MPA Blue, #8034, Molecular Devices, Sunnyvale CA) as described previously (Knapman et al ...
-
bioRxiv - Cancer Biology 2019Quote: ... The phosphorylation of the Hsp27 peptide was quantified using IMAP Progressive Screening Express Kit (Molecular Devices, catalog number R8127, Sunnyvale, CA) and the Analyst HT plate reader ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were then lysed and cAMP levels were measured using the cAMP Gs dynamic kit on the FlexStation 3 (Molecular Devices), according to the manufacturer’s protocol.
-
bioRxiv - Physiology 2023Quote: Intracellular Ca2+ was measured using the FLIPR Ca2+ 6 Assay Kit and a FlexStation 3 system (Molecular Devices, Sunnyvale, CA, USA). In brief ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... cells were loaded with 90 μL of fluorescent blue membrane potential dye (supplied in the FLIPR Membrane Potential Assay Kit, Molecular Devices). Membrane potential dye and drug dilutions were prepared in a low potassium buffer (NaCl 145mM ...
-
bioRxiv - Neuroscience 2019Quote: ... and digitized at 1 kHz (CyberAmp 380, Digidata 1440A, AxoScope 10 software, Molecular Devices). EEG synchronized video recordings (Logitech Software and Cerberus 4.0 Beta ...
-
bioRxiv - Biophysics 2021Quote: ... Currents were amplified and low-pass filtered at 1 kHz (Axopatch 200B, Molecular Devices), digitized at a sampling rate of 10 kHz (Digidata 1550B ...
-
bioRxiv - Cancer Biology 2022Quote: ... Traces were digitized at 1 kHz using the Digidata 1322A interface (Molecular Devices, USA) using Clampex 9.2 software (Molecular Devices ...
-
bioRxiv - Cell Biology 2023Quote: ... 1-ms pulse width) and the acquisition sequence driven by MetaMorph Software (Molecular Devices) or Zeiss Zen2 software at 5 Hz frequency ...
-
bioRxiv - Molecular Biology 2023Quote: ... using 50 Hz low-pass filters and digitization at 1 kHz (Molecular Devices, USA). The stock solutions (1 M ...
-
bioRxiv - Biochemistry 2020Quote: ... Cells were then dosed the following day and assayed using the FLIPR Calcium 6-QF Assay Kit (Molecular Devices, San Jose, CA) according to the manufacturer’s protocol ...
-
bioRxiv - Cell Biology 2021Quote: ... The growth medium of the cells was removed 16–20 h after transfection and the cells were loaded with 50 μl of Calcium 5 indicator (FLIPR® Calcium 5 assay kit, R8186, Molecular Devices) prepared in modified Krebs buffer containing 0.2 mM CaCl2 ...
-
bioRxiv - Immunology 2022Quote: ... stop solution (provided in the kit) was added and optical density measured within 5 minutes at 450 nm (SpectraMax iD3 Molecular Devices, USA). The inhibition rate was calculated ...
-
bioRxiv - Immunology 2022Quote: ... Caspase-3 activity was measured by Caspase-3 activity detection kit (Beyotime, China) and tested by a Flex Station II microplate reader (Molecular Devices, USA).
-
bioRxiv - Plant Biology 2024Quote: ... LUC and REN activities of other N benthamiana leaves were measured using a dual-luciferase assay kit (Yeasen Biotech, Shanghai, China) and a Spectra Max M2 (Molecular Devices, America) according to the manufacturer’s instructions.
-
bioRxiv - Molecular Biology 2022Quote: ... The library was cleaned up using Sera-Mag Select (Cytiva) and quantified by SpectraMax® Quant™ dsDNA Assay Kit (Molecular Devices). Pooled amplicon libraries were sequenced using Illumina MiSeq 2×250 kit.
-
bioRxiv - Biophysics 2021Quote: ... Recordings were filtered at 1 kHz and digitized at 10 kHz (Digidata 1440A; Molecular Devices). Pressure application through patch pipettes was performed with a high-speed pressure clamp (ALA Scientific ...
-
bioRxiv - Neuroscience 2020Quote: ... for acquisition (1-10 kHz) by pCLAMP10.2 software (Molecular Devices, LLC, San Jose, CA, USA). Glass recording microelectrodes were filled with aCSF (tip resistance ∼3MΩ ...
-
bioRxiv - Neuroscience 2019Quote: ... filtered at 1 kHz and analyzed offline using pClamp10 software (Molecular Devices, Sunnyvale, CA, USA).
-
bioRxiv - Neuroscience 2019Quote: ... filtered at 1 kHz and analyzed offline using pClamp10 software (Molecular Devices, Sunnyvale, CA, USA).
-
bioRxiv - Neuroscience 2024Quote: ... Electrical signals were filtered at 1 kHz by a Multiclamp 700B amplifier (Molecular Devices, USA), and digitized by an Axon DigiData 1550A converter with a sampling frequency of 10 kHz ...
-
bioRxiv - Neuroscience 2023Quote: ... Recorded currents were filtered at 1 kHz and digitized by a Digidata 1550A (Molecular Devices) digitizer at a sampling rate of 10 kHz ...
-
bioRxiv - Biophysics 2021Quote: The total content of cAMP in quenched samples was determined by using the CatchPoint cAMP Fluorescent Assay Kit (Molecular Devices, San Jose, USA) with some modifications ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... cells were incubated with 100 μL of a Ca2+-sensitive dye-loading buffer (FLIPR calcium 5 assay kit, Molecular Devices; Sunnyvale, CA, USA) containing 2.5 mM probenecid (Sigma-Aldrich ...
-
bioRxiv - Neuroscience 2020Quote: ... The data was low-pass filtered at 1 kHz (Molecular devices DigiData 1440A and Multiclamp 700B). Pipette series resistance and membrane holding current were monitored throughout all recordings to ensure stability of the recording.
-
bioRxiv - Physiology 2022Quote: ... Membrane voltage was obtained by using an Axoclamp 1-D amplifier (Molecular Devices, Sunnyvale, CA, USA) connected to a Digidata 1440A (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... at a sampling rate of 1 kHz and acquired using Clampex software (v. 10.7, Molecular Devices). To temporally match the EEG/EMG data with two-photon images ...
-
bioRxiv - Physiology 2019Quote: Fatty acid uptake was measured on paraformaldehyde fixed cells after 35 minutes incubation with the QBT™ Fatty acid uptake assay kit (Molecular Devices, California, USA) according to manufacturer’s instructions ...
-
bioRxiv - Microbiology 2023Quote: ... DNA quantification was performed in a 96-well microplate using the SpectraMax Quant dsDNA Assay Kit and the Gemini XPS Fluorometer (Molecular Devices, San Jose, CA), or in a single tube using the Qubit 2.0 fluorometer (Thermo Fisher Scientific ...
-
bioRxiv - Cancer Biology 2023Quote: ... Cell viability was assessed using the CCK-8 kit (Dojindo, Rockville, MD) by measuring absorbance at 450 nm (SpectraMax, Molecular Devices, San Jose, CA) according to the manufacturer’s instructions.
-
bioRxiv - Cell Biology 2024Quote: ... The PCR amplified RNA-Seq library products were then quantified using the Quant-iT™ dsDNA Assay Kit, High Sensitivity (In Vitrogen, reference Q33120) on a Gemini XPS (Molecular Devices, reference XPS05542). The library profiles were checked using High Sensitivity NGS Fragment Analysis kit (1-6000bp ...
-
bioRxiv - Biochemistry 2020Quote: ... Cell Signaling Technology) as the primary antibody (1:2000 dilution) and ScanLater anti-rabbit antibody (Molecular Devices) as the secondary antibody (1:5000 dilution) ...
-
bioRxiv - Cell Biology 2021Quote: ... spin-dried (200 g for 1 min) and scanned with a Genpix 4000B microarray scanner (Molecular Devices, made available by EMBL Genomics Core Facility) ...
-
bioRxiv - Neuroscience 2022Quote: ... were filtered at 1 kHz and digitized at 10 kHz with Digidata 1322A interface board (Molecular Devices) to record fEPSPs ...
-
bioRxiv - Biophysics 2021Quote: ... The reference electrode was a grounded Ag/AgCl pellet electrode (1-HLA-003, Molecular devices, California, USA). Borosilicate glass pipettes with filaments (BF150-86-7.5 ...
-
bioRxiv - Biophysics 2021Quote: ... a chlorinated silver wire (0.25 mm in thickness) was used (1-HLA-005, Molecular Devices, California, USA). The electrode was regularly abraded with sandpaper and immersed in commercial bleach solution for about 30 min in order to keep it chlorinated ...
-
bioRxiv - Neuroscience 2022Quote: ... Data were sampled at 1 kHz and recordings were analyzed offline using PClamp10 software (Molecular Devices, USA). Breathing frequency was calculated on a breath-to-breath basis ...
-
bioRxiv - Biophysics 2023Quote: ... Data were filtered at 1–3 kHz and digitized at 20 kHz using pClamp software (Molecular Devices) and a Digidata 1440A digitizer (Axon Instruments) ...
-
bioRxiv - Microbiology 2024Quote: ... 121 sites per well were imaged using a Plan-Apochromat 40x objective (Molecular Devices, #1-6300-0412). Automated image analysis was performed using a modular image analysis workflow built with the MetaXpress software (version 6.5.4.532 ...
-
bioRxiv - Neuroscience 2021Quote: ... Signals were low-pass filtered at 1 kHz and sampled at 10 kHz using Digidata 1440A (Molecular Devices). For mEPSC recordings ...
-
bioRxiv - Neuroscience 2021Quote: ... Signals were filtered at 5 kHz with the patch-clamp amplifier (Axopatch 1-D, Molecular Devices, Sunnyvale, CA) and sampling rate was adjusted according to the kinetics of membrane current ...
-
bioRxiv - Neuroscience 2022Quote: ... The signal was filtered at 1 kHz and digitized at 10 kHz using Axon Digidata 1550B (Molecular Devices). Recording pipettes (3.5-5 MΩ ...
-
bioRxiv - Cell Biology 2021Quote: ... 36 sites per well were imaged using a Plan-Apochromat 40x objective (Molecular Devices, cat# 1-6300-0297). Automated image analysis was performed using the MetaXpress software (version 6.5.4.532 ...
-
bioRxiv - Biophysics 2020Quote: ... The recording electrode was a chlorinated silver wire (0.25 mm thickness, 1-HLA-005, Molecular Devices, California, USA).
-
bioRxiv - Neuroscience 2021Quote: ... fEPSPs were recorded and filtered (low pass at 1 kHz) with an Axopatch 200A amplifier (Molecular Devices, LLC) and digitized at 10 kHz with an A/D converter (Digidata 1322A ...
-
bioRxiv - Synthetic Biology 2024Quote: ... The reaction was diluted 1:20 and the absorbance was measured in a spectrophotometer (Spectramax 190, Molecular Devices) in Nunc 96-well plates (ThermoFisher) ...
-
bioRxiv - Developmental Biology 2023Quote: ... which is repeated every 1 h from late E2.5 to E3.5 using a custom Metamorph journal (Molecular Devices). A 60 μm z-stack with a 5 μm step size is acquired before every time lapse to discern TE and ICM cells.
-
bioRxiv - Neuroscience 2023Quote: ... Data were filtered at 1 kHz and digitized at 20 kHz using a 1440A Digidata Digitizer (Molecular Devices). Series-resistance (10-20 MΩ ...
-
bioRxiv - Biophysics 2021Quote: Recordings containing 1-9 channels were idealized through half-amplitude threshold crossing and analyzed using Clampfit software (Molecular Devices).