Labshake search
Citations for Molecular Devices :
1401 - 1450 of 1573 citations for Glutathione Fluorescent 384 Well Detection Kit 2 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2021Quote: ... Plates were incubated for 5-15 minutes at room temperature and luminescence was measured on a Spectramax i3x plate reader (Molecular Devices, San Jose, CA, USA). Data analysis was performed using the Softmax Pro (Molecular Devices ...
-
bioRxiv - Bioengineering 2022Quote: ... was normalized to bacterial growth using optical density measured as absorbance at 600 nm (OD600) on a plate reader (Spectra Max 3, Molecular Devices, San Jose, CA, USA). Bioluminescent signals were quantified using the 8x12 grid ROI for all wells (in vitro thermocycler induction ...
-
bioRxiv - Immunology 2020Quote: ... 1M HCl was used to stop conversion of TMB and optical density was measured at 450nm (OD450) and 540nm (OD540) using a Spectra Max 190 plate reader (Molecular Devices, San Jose, CA USA). Optical imperfections in assay plates were corrected through subtraction of OD540 values ...
-
bioRxiv - Neuroscience 2022Quote: ... the concentration of leaked LY was measured on the basolateral side at excitation/emission wavelengths of 428/536 nm using a SpectraMax I3 plate reader (Molecular Devices, San Jose, California, USA). Only monolayers exhibiting an apparent permeability (Papp ...
-
bioRxiv - Microbiology 2022Quote: ... The growth kinetics of bacteria were determined by reading their optical densities at wavelength of 600 nm using SpectraMax plate reader ((Molecular Devices SpectraMax® ABS Plus) (Molecular Devices LLC. ...
-
bioRxiv - Systems Biology 2023Quote: A kinetic time course to monitor changes in optical density was used to measure at OD595 nm every 15 minutes using a Molecular Devices Filtermax F5 plate reader (Molecular Devices LLC, San Jose, CA) set to “high” shake speed and linear shaking mode in a 24 well microtiter dish plate sealed with a Breathe-EasyⓇ transparent membrane (Sigma-Aldrich) ...
-
bioRxiv - Microbiology 2023Quote: ... The reaction was stopped by the addition of stop solution and the optical density was measured at 450 nm using a muti-mode plate reader (SpectraMax iD5, Molecular Devices, San Jose, CA, USA).
-
bioRxiv - Immunology 2023Quote: ... Samples were incubated 1–16 h at room temperature and absorbance at 490 nm was read on a SpectraMax M2 plate reader (Molecular Devices, San Jose, California, USA). Data were analyzed with SoftMax Pro software 6.2.2 ...
-
bioRxiv - Plant Biology 2023Quote: ... The reaction mixture was incubated at 37°C for 30 min and rate of NADH oxidation was measured at 340 nm in SpectraMax M5 plate reader (Molecular Devices, San Jose, CA, USA). Oxalate in a range of 5 μM to 400 μM was used to determine Km and Vmax ...
-
bioRxiv - Microbiology 2024Quote: ... Redox dye formation was monitored at OD595 24 h and 48 h post inoculation using a Filtermax F5 plate reader (Molecular Devices LLC, San Jose, CA).
-
bioRxiv - Immunology 2024Quote: ... in 1 mM AMP and 0.1 mM MgCl2•6H2O and plates were read at 405 nm using a SpectraMax ABS PLUS spectrophotometer (Molecular Devices, San Jose, CA, United States). A detailed protocol can be found in the supplementary methods section ...
-
bioRxiv - Bioengineering 2019Quote: ... Currents were filtered at 2-3 kHz and sampled at 10 kHz using a Digidata 1440 A (Molecular Devices). Patch pipettes (4-6 MΩ ...
-
bioRxiv - Neuroscience 2020Quote: ... a 2 KHz Bessel filter was applied to the data during collection using the MultiClamp 700B (Molecular Devices, CA). For mPSC recordings ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... Data was quantified by measuring fluorescence intensity at 495 nm excitation and 517 nm emission (Flexstation 2, Molecular devices). Ter-butyl hydroperoxide was used as a positive control ...
-
bioRxiv - Neuroscience 2023Quote: ... Recordings were made using an Axoclamp 2 B amplifier with HS-2A x0.1 head stage (Molecular Devices, CA, USA) on a BX51WI Olympus microscope with a 40X LUMPlanFL/IR water immersion objective (Olympus Corporation ...
-
bioRxiv - Physiology 2023Quote: ... and the data were sampled at 2 kHz and filtered at 1 kHz using pClamp 10 software (Molecular Devices). Light stimulation was applied using LEDs and a multi-LED driver through the microscope optics (DC4100 ...
-
bioRxiv - Neuroscience 2023Quote: ... filtered at 2 kHz and digitized at 10 kHz using a MultiClamp 700B amplifier and Digidata 1550 (Molecular Devices). Clampex version 11.4 (Molecular Devices ...
-
CDK5 activity in retinal pigment epithelium contributes to gap junction dynamics during phagocytosisbioRxiv - Cell Biology 2023Quote: ... All recordings were made in current-clamp mode with a 2-channel patch-clamp amplifier (MultiClamp 700B, Molecular Devices). To analyze the input resistance ...
-
bioRxiv - Neuroscience 2023Quote: ... The data were filtered at 2 kHz and sampled at 10 kHz via a digitizer (Digidata 1440, Molecular Devices) and recorded using Clampex 10.6 software (Molecular Devices) ...
-
bioRxiv - Bioengineering 2022Quote: ... an EarlyTox Live/Dead Assay kit was used (Molecular Devices) and the microplate was imaged with a laser and GFP and TXR filters ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... The level of pNfH of each sample was measured as an absorbance at 450 nm in a SpectraMax plate reader (Molecular Devices, LLC., San Jose, CA, USA). The 8-OHdG levels in urine collected from 7-week-old mice were measured once for each sample by using the 8-OHdG DNA Damage ELISA kit manufactured by Cell Biolabs ...
-
bioRxiv - Neuroscience 2021Quote: ... and maintained at room temperature for > 1.5 h before recording (34⁰ C; 2-3 ml/min perfusion; Olympus BX-51WI microscope; Molecular Devices Multiclamp 700B amplifier ...
-
bioRxiv - Neuroscience 2019Quote: ... filtered at 2 kHz and digitized at 20 kHz with a DigiData 1440 data acquisition board (Molecular Devices, Sunnyvale, CA). Analysis of electrophysiological parameters was done using Clampfit (Molecular Devices ...
-
bioRxiv - Neuroscience 2019Quote: ... Data were low-pass filtered at 2 kHz and acquired via an Axopatch 700B amplifier (Molecular Devices, Foster City, CA) and later analyzed using pClamp 10 software (Molecular Devises ...
-
bioRxiv - Neuroscience 2020Quote: ... Signals were low-pass filtered (Bessel, 2 kHz) and collected at 10 kHz using the data acquisition software pClamp 10.5 (Molecular Devices). Optical stimulation was applied through the microscope with two LEDs (460 nm and 525 nm ...
-
bioRxiv - Neuroscience 2020Quote: ... The data were low-pass filtered at 2 kHz and digitized at 10 kHz using a Digidata 1322A (Molecular Devices) and stored using Clampex version10 ...
-
bioRxiv - Cell Biology 2021Quote: ... Fluorescence was measured after 2 hours of incubation at 37°C using the SpectraMax® iD3 microplate reader (Molecular Devices). To compare growth rates ...
-
bioRxiv - Neuroscience 2020Quote: ... Signals were low-pass filtered (Bessel, 2 kHz) and collected at 10 kHz using the data acquisition software pClamp 10.5 (Molecular Devices). Electrophysiological recordings were extracted using Clampfit (Molecular Devices ...
-
bioRxiv - Cell Biology 2021Quote: ... Data were digitized at 10 kHz with a 2 kHz low-pass filter using a Multiclamp 700A amplifier (Molecular Devices). For all electrophysiological experiments ...
-
bioRxiv - Neuroscience 2021Quote: ... filtered at 2 kHz and sampling rate at 20 kHz with an Axon Digidata 1550B plus HumSilencer digitizer (Molecular Devices). Slices were maintained under continuous perfusion of aCSF at 32-33°C with a 2-3 mL/min flow ...
-
bioRxiv - Neuroscience 2021Quote: ... Signals were low pass filtered (Bessel, 2 kHz) and collected at 10 kHz using the data acquisition software pClamp 10.5 (Molecular Devices). All the electrophysiological recordings were extracted using Clampfit (Molecular Devices ...
-
bioRxiv - Developmental Biology 2021Quote: ... 340/386 nm image pairs were acquired every 2 s with the MetaFluor software (Molecular Devices Corp, Downington, PA, USA). [Ca2+]i was calculated from the background-corrected Fura-2 LR 340/380 nm fluorescence excitation ratio from manually defined cell-sized regions of interest ...
-
bioRxiv - Neuroscience 2020Quote: Signals were low-pass filtered at 2 kHz and digitised at 10 kHz using an Axopatch 200B amplifier (Molecular Devices) and WinLTP v1.11 acquisition software [46].
-
bioRxiv - Neuroscience 2020Quote: Data were digitized at 10 kHz with a 2 kHz low-pass filter using a Multiclamp 700A amplifier (Molecular Devices). Data were analyzed using Clampfit 9.02 software ...
-
bioRxiv - Biochemistry 2021Quote: ... All currents were sampled at 10 kHz and low-pass filtered at 2 kHz through pCLAMP software (Molecular Devices, Sunnyvale). Origin 9.0 software (OriginLab Corp. ...
-
bioRxiv - Neuroscience 2022Quote: ... Signals were low-pass filtered (Bessel, 2 kHz) and collected at 10 kHz using the data acquisition software pClamp 10.5 (Molecular Devices). All the electrophysiological recordings were extracted using Clampfit (Molecular Devices ...
-
bioRxiv - Molecular Biology 2022Quote: ... filtered at 2 kHz and digitized at 5 kHz using Digidata 1440A interface with pClamp 10 software (Molecular Devices Corporation). Series resistance was typically 5–20 MΩ ...
-
bioRxiv - Neuroscience 2023Quote: ... both connected to a 2-way 4-port electric rotary valve (Bio-Chem Fluidics) and the pClamp 10.6 software (Molecular Devices).
-
bioRxiv - Neuroscience 2023Quote: ... Neurons were recorded from layers 2/3 (100 to 400 μm below the pia) using a Multiclamp 700B (Molecular Devices). Series resistance for recordings typically ranged from 20 to 80 MΩ ...
-
bioRxiv - Neuroscience 2023Quote: ... and data were digitized at 10 kHz and filtered at 1-2 kHz using a 1440A Digidata Digitizer (Molecular Devices). Series and input resistances (10-20 MΩ ...
-
bioRxiv - Cell Biology 2023Quote: ... Dual channel live acquisition was performed using 2 EMCCD cameras (QuantEM Model 512SC, Princeton Instruments) controlled by Metamorph 7.10 software (Molecular Devices). The gain of the EMCCD cameras was kept constant at 600 ...
-
bioRxiv - Neuroscience 2023Quote: ... the slope of the first 1-2 ms of the fEPSP was obtained using Clampfit software (version 10.6; Molecular Devices) and averaged in 1-min bins ...
-
bioRxiv - Molecular Biology 2019Quote: ... and Earlytox live/dead assay kit (Molecular Devices, San Jose, CA) were used for studies of INS-1 cells treated with CSE or AC extract with or without 5 mM N-Acetyl Cysteine (NAC ...
-
bioRxiv - Immunology 2022Quote: ... in conjunction with the FLIPR Calcium 6 dye kit (Molecular Devices) as previously described (Dal Porto et al. ...
-
bioRxiv - Immunology 2023Quote: ... in conjunction with the FLIPR Calcium 6 dye kit (Molecular Devices). On the day of the experiments ...
-
bioRxiv - Cell Biology 2020Quote: ... incubated for 2 hours with 100 nM Coelenterazine Cp and washed before initiating measurements using a spectrophotometer (SpectraMax M, Molecular Devices) equipped with injectors allowing the detection of luminescence in a kinetic mode.
-
bioRxiv - Cell Biology 2020Quote: Mitochondrial morphology was assessed in a strain carrying bcIs78 (Pmyo-3::gfpmt) using a Zeiss Axioskop 2 with a 63x objective and MetaMorph software (Molecular Devices).
-
bioRxiv - Neuroscience 2021Quote: ... in time-lapse mode either at 1 fps (for imaging in response to 200-APs stimulation) or 2 fps (for imaging in response to 50-APs stimulation) under the control of MetaMorph software (Molecular Devices). SEP fluorescence was imaged with 470/22 nm excitation and 514/30 nm emission filters ...
-
bioRxiv - Cell Biology 2019Quote: ... Signals were recorded at 10 kHz and low-pass filtered at 2 kHz with an Axopatch 200B amplifier and digitized with a Digidata 1440 (Molecular Devices). Recording pipettes were pulled from borosilicate capillary glass (0.86 OD ...
-
bioRxiv - Cell Biology 2019Quote: ... and 2) a Nikon Eclipse 80i microscope using a 100X/1.4NA oil objective lens and Metamorph (Molecular Devices, San Jose, CA). Yeast were grown in SD media to log phase ...