Labshake search
Citations for Molecular Devices :
1001 - 1050 of 10000+ citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... Electrical signals were digitized and sampled at 10 ms intervals with the Digidata 1550 data acquisition system and the Multiclamp 700B Amplifier (Molecular Devices) using the pClamp10.2 software ...
-
bioRxiv - Neuroscience 2024Quote: Recordings were made with a MultiClamp 700B amplifier (Molecular Devices) at RT using 3-5 MOhm glass patch electrodes (Sutter ...
-
bioRxiv - Neuroscience 2024Quote: ... coupled with Clampex software (Molecular Devices, CA, USA). Recording traces were collected and further analyzed by Clampx software ...
-
bioRxiv - Cancer Biology 2024Quote: ... The absorbance was read at 575 nm with FlexStation3 (Molecular Devices). The experiments were run at least three times.
-
bioRxiv - Cell Biology 2024Quote: ... the fluorescence was measured at Ex/Em = 540/590 nm using a SpectraMax M5 microplate reader or Spectra Max iD5 (Molecular devices) with SoftMax Pro v7 (Molecular devices ...
-
bioRxiv - Cell Biology 2024Quote: Mean currents normalized to cell capacitance were analyzed and plotted using pClamp10.4 (Molecular Devices), Microsoft Excel ...
-
bioRxiv - Cell Biology 2024Quote: ... Whole-cell voltage-clamp recordings were acquired with an AxoClamp200B amplifier (Molecular Devices), using pClamp10.4 ...
-
bioRxiv - Cell Biology 2024Quote: ... was obtained for ratiometric analysis at 37 °C with sampling every 5 minutes for two hours in a microtiter plate reader (Molecular Devices ID3, San Jose CA, USA). The calcium ionophore ionomycin (10 µM ...
-
bioRxiv - Cell Biology 2024Quote: ... The fluorescence was captured by a CCD camera (Orca-ER, Hamamatsu) that was controlled by MetaFluor software (Molecular Devices).
-
bioRxiv - Cell Biology 2024Quote: ... A back-illuminated EMCCD camera (DU-897; Andor Technology) controlled by MetaMorph (Molecular Devices) was used to detect fluorescence ...
-
bioRxiv - Cancer Biology 2024Quote: ... Experimental protocols and data acquisition were performed with the Multiclamp 700 A or Multiclamp 1D amplifiers and pCLAMP 9.2 software (Molecular Devices, Sunnyvale, CA, USA) was used for data analysis ...
-
bioRxiv - Cancer Biology 2024Quote: ... Calcium imaging analysis and quantification (peak amplitude, area, rise time, decay time) were performed using Clampfit software (Axon Pclamp, Molecular Devices; San Jose, CA, USA) and analyzed with GraphPad Prism 8 (GraphPad Software Inc. ...
-
bioRxiv - Cancer Biology 2024Quote: ... Image acquisition (3 s frequency) was performed using Metafluor Imaging System (Molecular Devices; Sunnyvale, CA, USA). For each experiment ...
-
bioRxiv - Biophysics 2024Quote: ... and stored in a computer (pClamp11.1, Molecular Devices). The standard internal pipette solutions for the whole-cell voltage clamp recordings from the ND7/23 cells contained (in mM ...
-
bioRxiv - Cell Biology 2024Quote: ... Metamorph software (Molecular Devices) was used to control the imaging system ...
-
bioRxiv - Cell Biology 2024Quote: ... robotic system (Molecular Devices, San Jose, United States) which employed a 300 W Xenon lamp as previously described (15) ...
-
bioRxiv - Cell Biology 2024Quote: ... with SoftMax Pro v7 (Molecular devices) after 4 h of incubation in a normal culture medium containing resazurin.
-
bioRxiv - Cancer Biology 2024Quote: ... and luciferase signal was read for 1.5 seconds on a SpectraMax M5 (Molecular Devices). To combine replicates for statistical analysis ...
-
bioRxiv - Neuroscience 2024Quote: ... F signals were neuropil corrected and aligned to timing of visual stimulation and arousal state data (i.e. pupil size, whisking) using frame time signals collected in Clampex (Molecular Devices) during recording sessions.
-
bioRxiv - Neuroscience 2024Quote: Whole-cell current- and voltage-clamp data were analyzed using ClampFit (Molecular Devices), Microsoft Excel ...
-
bioRxiv - Plant Biology 2024Quote: ... The fluorescence emission of 20 μM CbCaM/CML was recorded in a SpectraMax Paradigm (Molecular Devices) using 250 μM ANS in TBS in the presence or absence of calcium and magnesium ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell recordings were performed using a Multiclamp 700B amplifier (Molecular Devices) and fire-polished borosilicate pipettes (Sutter Instruments ...
-
bioRxiv - Synthetic Biology 2024Quote: ... cell densities were measured at 595 nm (OD595) using FilterMax F5 (Molecular Devices). The FD score is defined below: where the concentration of D-fucose is 10 mM ...
-
bioRxiv - Neuroscience 2024Quote: ... Data were exported to a spreadsheet using the AcuityXpress software package (Molecular Devices). Three metrics were used ...
-
bioRxiv - Neuroscience 2024Quote: High Content imaging was performed as in (18) using an ImageXpress micro high content imaging system (Molecular Devices, Downingtown, PA) driven by MetaXpress software ...
-
bioRxiv - Neuroscience 2024Quote: ... Recordings were made using a Multiclamp 700B amplifier (Molecular devices, CA, USA) and signals were obtained in bridge mode ...
-
bioRxiv - Neuroscience 2024Quote: ... filtered at 3 kHz and digitized at 10 kHz via a Digidata 1440A interface (Molecular Devices, CA, USA). Experimental protocol was adjusted from (Le Bail et al. ...
-
bioRxiv - Neuroscience 2024Quote: Data were analyzed using pClamp10 software (Molecular Devices, CA, USA). For paired-pulse ratio analysis ...
-
bioRxiv - Neuroscience 2024Quote: ... the photocurrent signal was low-pass filtered by an anti-aliasing filter before being digitized by a 16-bit A/D board (Digidata 1322, Molecular Devices). The photodiode system had a cutoff (3 dB ...
-
bioRxiv - Neuroscience 2024Quote: ... running on an IBM-compatible computer and a 16-bit A/D converter (Digidata 1322, Molecular Devices). Motility was measured and calibrated by a photodiode-based measurement system (Jia and He ...
-
bioRxiv - Neuroscience 2024Quote: ... Current was recorded with an Axopatch 200B amplifier (Molecular Devices, Foster City, CA) filtered with a 10-kHz low-pass Bessel filter and digitized at 25 kHz (ITC-18 board ...
-
bioRxiv - Neuroscience 2024Quote: ... Electrophysiological data were acquired by an AxoPatch 200B amplifier and pClamp 10.7 software (Molecular Devices, Wokingham, UK). The current-voltage (I-V ...
-
bioRxiv - Neuroscience 2024Quote: ... recordings were done using an Axopatch-200A amplifier and pCLAMP acquisition software (Molecular Devices). Data was low pass filtered at 2 kHz and acquired at 10 kHz ...
-
bioRxiv - Neuroscience 2024Quote: ... The amount of internalized KCC2-pHext (Fi, internalized fluorescence pool) was quantified post-hoc using MetaMorph software (Molecular Devices) and included only Alexa 555 ...
-
bioRxiv - Neuroscience 2024Quote: ... Confocal micrographs are digital composites of a Z-series scan of 9 optical sections through a depth of 4 – 5 µm and processed using MetaMorph software (Molecular Devices).
-
bioRxiv - Neuroscience 2024Quote: ... The fluorescence signal was sampled at 0.1 Hz using a CoolSNAPHQ Monochrome CCD camera and MetaMorph software (Molecular Devices Corp). Excitation lasted 100 ms for F480 and 50 ms for F577 ...
-
bioRxiv - Neuroscience 2024Quote: ... Both fluorescence and luminescence signals in these assays were quantified using a SpectraMax iD3 plate reader (Molecular Devices).
-
bioRxiv - Neuroscience 2024Quote: ... a Multiclamp 700B amplifier (Molecular Devices) and Ephus software 94 ...
-
bioRxiv - Neuroscience 2024Quote: ... sampled at 25 kHz (Digidata 1550B, Molecular Devices), and low-pass filtered at 10 kHz using pCLAMP 11 ...
-
bioRxiv - Neuroscience 2024Quote: ... Data were acquired with a MultiClamp 700B amplifier (Molecular Devices, Sunnyvale, CA, USA) digitized using a Digidata 1550 interface and the Pclamp10.6 software package ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell patch-clamp recordings were performed from the transfected HEK293 cells ∼16-48 h after the transfection using an Axopatch 200B amplifier (Molecular Devices, San Jose, CA, USA) with series resistance (<10 MΩ ...
-
bioRxiv - Neuroscience 2024Quote: ... and digitized at 10 kHz using a patch-clamp amplifier (Multiclamp 700B, Molecular Devices). Nearly all recordings were made using 3-5 MΩ borosilicate pipettes (Sutter ...
-
bioRxiv - Neuroscience 2024Quote: ... All mPSC raw traces were first lowpass filtered in Clampfit (Molecular Devices) using a boxcar filter ...
-
bioRxiv - Neuroscience 2024Quote: ... Signals were acquired using the MultiClamp 700B amplifier and digitized at 20 kHz using DigiData1550B (Molecular Devices). The recorded electrophysiological data were analyzed using Clampfit (Molecular Devices ...
-
bioRxiv - Neuroscience 2024Quote: Data for Na+ and K+ current or APs were analyzed with Axon Clampfit (Molecular Devices), and data for sEPSC and sIPSC were analyzed with Mini Analysis (Synaptosoft).
-
bioRxiv - Neuroscience 2024Quote: ... Data collection was controlled using pClamp 10.4 (Molecular Devices). Recordings were made with fire polished glass pipettes (4-8 MΩ ...
-
bioRxiv - Neuroscience 2024Quote: ... An Axon Digidata 1440A (Molecular Devices, San Jose, CA, USA) and Clampex 11 software (Molecular Devices ...
-
bioRxiv - Neuroscience 2024Quote: ... RNA concentration was determined using a Quick Drop device (Molecular Devices). Complementary DNA (cDNA ...
-
bioRxiv - Neuroscience 2024Quote: ... The recorded electrophysiological data were analyzed using Clampfit (Molecular Devices) and MATLAB (Mathworks).
-
bioRxiv - Neuroscience 2024Quote: ... using Multiclamp 700B amplifier (Molecular Devices, Inc.). Recordings were performed at room temperature ...