bioRxiv - Neuroscience 2020Quote: ... Electrophysiological signals were sampled at 20 kHz on a DigiData 1550A A/D converter (Molecular Devices).
-
bioRxiv - Physiology 2022Quote: ... Membrane voltage was obtained by using an Axoclamp 1-D amplifier (Molecular Devices, Sunnyvale, CA, USA) connected to a Digidata 1440A (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... Data were digitized with a Digidata 1440A A/D interface and recorded using pCLAMP10 (Molecular Devices). Borosilicate glass pipettes were pulled on a P-97 puller (Sutter Instruments) ...
-
bioRxiv - Physiology 2024Quote: ... This setup was interfaced to a computer with the Digidata 1440A A/D converter (Molecular Devices), where the Clampex software package (v10 ...
-
bioRxiv - Immunology 2023Quote: ... stopped with 100 uL of 1% sodium dodecyl sulfate (SDS) in distilled water and read at 450 nm using a Spectra-Max plate reader (Molecular Devices. Sunnyvale, CA).
-
bioRxiv - Pathology 2022Quote: ... and currents were sampled at 20 KHz through an A/D converter (DigiData 1440, Molecular Devices, CA) and low pass filtered at 5 kHz ...
-
bioRxiv - Neuroscience 2021Quote: ... power supply (TTi PL-303) digitally tuned and controlled using Digidata 1440A A/D interface (Molecular Devices) and pClamp10 software.
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... filtered at 1 kHz and collected at 10 kHz or using an Axopatch 1-D (Molecular Devices), filtered at 2 kHz ...
-
bioRxiv - Neuroscience 2022Quote: ... we used a MultiClamp-700B amplifier equipped with Digidata-1440A A/D converter and Clampex (Molecular Devices).
-
bioRxiv - Neuroscience 2024Quote: ... running on an IBM-compatible computer and a 16-bit A/D converter (Digidata 1322, Molecular Devices). Motility was measured and calibrated by a photodiode-based measurement system (Jia and He ...
-
bioRxiv - Immunology 2024Quote: ... For the R&D Duoset kits the ELISA were read using an i3X Spectrophotometer (Molecular Devices, LLC). For the LegendPlex assays ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... and digitized through a 12-bit A/D converter (Axon Digidata 1440A, Molecular Devices, Sunnydale, CA, USA) with a sampling rate of 1 kHz ...
-
bioRxiv - Cancer Biology 2020Quote: ... Stain was collected using 10% acetic acid and quantified in a spectrophotometer at 590 nm (SpectraMax ID3, Molecular Devices). The average stain quantification was generated from the water control group and each experimental value was divided by this average to produce a normalized fold change value ...
-
bioRxiv - Immunology 2024Quote: ... The reaction was stopped using 2M sulfuric acid and absorbance was measured on a SpectraMax190 Microplate Reader (Molecular Devices) at 450 nm ...
-
bioRxiv - Neuroscience 2021Quote: ... Signals were filtered at 5 kHz with the patch-clamp amplifier (Axopatch 1-D, Molecular Devices, Sunnyvale, CA) and sampling rate was adjusted according to the kinetics of membrane current ...
-
bioRxiv - Physiology 2020Quote: ... Both nerve and intracellular signals were sent to an A/D converter (Digidata 1322A, Molecular Devices, Sunnyvale, CA), digitized at 20 kHz and viewed on a computer monitor using pClamp software (version 10.2 ...
-
bioRxiv - Cancer Biology 2024Quote: ... digitized through a Digidata 1550B A/D converter and acquired and analyzed using pClamp 11 software (Molecular Devices). Recordings commenced only after passive properties had stabilized and these values were used for analysis ...
-
bioRxiv - Physiology 2023Quote: ... Channel currents were recorded at 1 kHz with an Axopatch 1-D amplifier (Molecular Devices Inc., Sunnyvale, CA) with a low-pass 100-Hz 8-pole Bessel filter ...
-
bioRxiv - Microbiology 2020Quote: ... Plates were fluorescently imaged using an Image Xpress Micro 4 (Molecular Devices). Images were analyzed for N stain per nuclei with the CellProfiler 3.1.9 software (Broad Institute ...
-
bioRxiv - Neuroscience 2022Quote: ... with a high content screening confocal microscope (ImageXpress Micro 4, Molecular Devices). Acquired images were transferred and stored on a Columbus (PerkinElmer ...
-
bioRxiv - Biochemistry 2024Quote: ... 4-MU fluorescence was measured by SpectraMax ID3 (Molecular Devices, Sunnyvale, CA) [30] with 360 nm excitation ...
-
bioRxiv - Neuroscience 2020Quote: ... and stored (MultiClamp 700B amplifier; ITC-18 or Digidata 1440A A-D board) using either pClamp 10.0 (Molecular Devices) or IGOR Pro software (Wavemetrics) ...
-
bioRxiv - Bioengineering 2024Quote: ... Following the manufacturer’s instructions D-dimer was measured using a Molecular Devices Spectramax Plus (Molecular Devices, San Jose, California) plate reader ...
-
bioRxiv - Neuroscience 2023Quote: ... or NI USB-6341 A/D board (National Instruments) and WinLTP version 2.2027 or pClamp 11.0 software (Molecular Devices) were used for data collection ...
-
bioRxiv - Cancer Biology 2020Quote: ... Destaining for quantification was performed using 10% acetic acid and absorbance was read at 590 nm using a spectrophotometer (SpectraMax iD3, Molecular Devices). An average value of non-targeting vehicle was generated ...
-
bioRxiv - Cell Biology 2020Quote: ... The reaction was stopped by adding 100 μL 2M sulfuric acid and absorbance was measured at 450 nm on a Spectramax M5 (Molecular Devices).
-
bioRxiv - Microbiology 2021Quote: ... The reaction was stopped using 1N sulfuric acid and the ELISA plates were read in multi-mode reader (Molecular devices, USA) at 450 nm.
-
bioRxiv - Immunology 2022Quote: ... the reaction was stopped using 2 N sulfuric acid and the optical density (O.D) was read at 492nm in a multiplate reader (FilterMax F3, Molecular Devices, USA). For antibody response measured in sera data was represented in the graphics as log10 titers ...
-
bioRxiv - Biophysics 2020Quote: ... The supernatants were transferred to a fresh microfuge tube and protein concentrations of the clarified cellular lysates were determined by using the bicinchoninic acid assay (Rapid Gold BCA Assay, Pierce) in a microtiter plate format with a plate reader (Molecular Devices). Using the results from the BCA Assay ...
-
bioRxiv - Microbiology 2022Quote: ... the reaction was stopped with 2N sulfuric acid and the absorbance was measured at 450nm using VersaMax Microplate Reader (Molecular Devices).
-
bioRxiv - Microbiology 2024Quote: ... and quantified by solubilization in 30% acetic acid and measurement of absorbance at 550 nm on a SpectraMax M2 microplate reader (Molecular Devices).
-
bioRxiv - Bioengineering 2022Quote: ... The HRP reaction was stopped with 1M hydrochloric acid and absorbance values at 450 nm were measured on a SpectraMax i3x plate reader (Molecular Devices).
-
bioRxiv - Synthetic Biology 2023Quote: ... Reactions were terminated by adding 50 μL of 1M orthophosphoric acid and absorbance (450 nm) was measured with SpectraMax iD5 microplate reader (Molecular Devices).
-
bioRxiv - Immunology 2024Quote: ... The reaction was stopped with 2N of sulfuric acid (Ricca Chemical Cat# 8310-32) and read at 450 nm on a FlexStation 3 plate reader (Molecular Devices).
-
bioRxiv - Immunology 2024Quote: ... The reaction was stopped with 2N of sulfuric acid (Ricca Chemical, Cat#: 8310-32) and read at 450 nm on a FlexStation 3 plate reader (Molecular Devices).
-
bioRxiv - Developmental Biology 2022Quote: ... Calcium Imaging: Cardiomyocytes were incubated with 1x FLIPR Calcium 4 dye (Molecular Devices) diluted in RPMI + B27 for 1.5 h at 37°C ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Cells were loaded with 20 μl per well Calcium 4 dye (Molecular Devices) reconstituted in assay buffer containing (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... Data were stored on a PC for offline analysis after digitization using an A/D converter (Digidata 1440A, Molecular Devices).
-
bioRxiv - Neuroscience 2021Quote: ... together with the Clampator One amplifier (model CA-1B, Dagan Co.) and the A/D converter Digidata 1440A (Molecular Devices). Borosilicate glass capillary electrodes were pulled using a vertical pipette puller (PIP 5 ...
-
bioRxiv - Neuroscience 2020Quote: ... Data were collected and digitized at 50 kHz using a Digidata 1440 16-bit A/D converter controlled by pCLAMP 10.5 software (Molecular Devices).
-
bioRxiv - Cancer Biology 2021Quote: ... All recordings were performed at RT using an Axopatch 200B amplifier and a Digidata 1322A A/D board (Molecular Devices) and acquired at 5 kHz ...
-
bioRxiv - Neuroscience 2022Quote: ... and an Axopatch 200B patch-clamp amplifier (in combination with a Digidata 1550 A/D converter and pClamp 10.7 software; all Molecular Devices) cell-attached and then whole-cell configurations were established to excise outside-out patches ...
-
bioRxiv - Cell Biology 2020Quote: ... Stacks were processed into 2-color overlays of maximal intensity 2-D projections and analyzed with MetaMorph software (Molecular Devices). Linescans for fluorescence intensity along the spindle axis were generated with the line tool set to 3-pixel width and normalized intensity plots produced in Microsoft Excel ...
-
bioRxiv - Neuroscience 2022Quote: ... Data were acquired with a low pass filter at 3.0 kHz and sampled at 10.0 kHz using an A/D converter Digidata 1320A (Axon Instruments) or Axon Digidata 1550B (Molecular Devices). Digidata 1320A with pClamp 10.7 software (Molecular Devices ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Stimulation and data recordings were performed using an Axopatch 200B amplifier controlled by Axon pClamp 10.6 software through an A/D converter (Digidata 1440A, Molecular Devices). The data were analyzed using home-made R scripts ...
-
bioRxiv - Neuroscience 2023Quote: ... high-pass filtering at 0.2 Hz and sampling at 10 kHZ using a Digidata 1320 A/D interface (Molecular Devices). LFP data was stored on a PC computer running AxoScope 10.3 software (Molecular Devices ...
-
bioRxiv - Microbiology 2021Quote: ... Reaction was terminated using 1 N sulfuric acid and the absorbance was read at 450 nm in a multi-mode plate reader (Molecular devices, USA).
-
bioRxiv - Biophysics 2022Quote: ... Protein concentrations of clarified lysates were determined using the bicinchoninic acid assay (Rapid Gold BCA Assay, Pierce) in a microtiter format with a plate reader (Molecular Devices iD3) using BSA as a calibration standard ...
-
bioRxiv - Microbiology 2023Quote: ... The biofilms were dissolved in 100 µl of 30% acetic acid and the optical density at 595 nm (OD595nm) was measured using a SpectraMax® ID3 plate reader (Molecular Devices) to quantify the biofilm biomass ...
-
bioRxiv - Immunology 2020Quote: ... An equal volume of assay loading buffer (FLIPR Calcium 4 assay kit, Molecular Devices) in Hank’s balanced salt solution supplemented with 20 mM HEPES and 2 mM probenecid was added ...