Citations for Molecular Devices :
51 - 100 of 1100 citations for 10 14 Cadinene 4 5 Diol since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... Recordings were made with pClamp 10.3 software using a MultiClamp 700B amplifier set with 4 kHz low-pass Bessel filter and 10 kHz digitization (Molecular Devices, Sunnydale, CA). The light beam of the same laser was directed at the preparation using an 200μm optic fiber submerged into the bath with light beam aimed at the STN ...
-
bioRxiv - Neuroscience 2020Quote: ... All recordings were sampled at 10 kHz and filtered with a 5 kHz low-pass filter using an Axopatch 200B amplifier (Molecular Devices, U.S.A.) and AxoGraph ...
-
bioRxiv - Biophysics 2020Quote: Clampfit 10 (pCLAMP 10, Molecular Devices), Origin 9.1 (OriginLab Corp. ...
-
bioRxiv - Biophysics 2020Quote: ... Clampex 10 (pCLAMP 10, Molecular Devices) was used to control voltage protocols and for data acquisition.
-
bioRxiv - Neuroscience 2021Quote: Cortical neurons (DIV 14-19) with GFP fluorescence were patched at room temperature using a Multiclamp 700B amplifier (Molecular Devices). Recording pipettes were pulled from borosilicate glass (Sutter Instruments ...
-
bioRxiv - Cell Biology 2024Quote: Plates were imaged using a Molecular Devices Confocal Imager at 20x resolution with an extra long working distance (ELWD) objective (n/a =0.45) with at least 14 fields per well on an Image Xpress Confocal (Molecular Devices) while avoiding the corners of the well ...
-
bioRxiv - Neuroscience 2020Quote: ... All recordings swere filtered (4 kHz low-pass filter) and sampled (10 kHz) for online and later offline analysis with Multiclamp 700B amplifier (Molecular Devices, Sunnyvale, CA, USA) and Clampfit v.10.5 software (Molecular Devices).
-
bioRxiv - Neuroscience 2022Quote: ... Signals were low-pass filtered at 5 kHz and sampled at 10 kHz using a digitizer (Digidata 1440A; Molecular Devices, Sunnyvale, CA, USA). In ex vivo slice recordings ...
-
bioRxiv - Neuroscience 2021Quote: ... Data were low-pass filtered at 5 kHz and acquired at 10 kHz with Axopatch 200B amplifiers and CV-7B headstages (Molecular Devices, Sunnyvale, CA). Data were acquired using an in-house program written either in Igor Pro (Wavemetrics ...
-
bioRxiv - Neuroscience 2021Quote: ... membrane voltages were adjusted for liquid junction potentials (approximately –14 mV) calculated using JPCalc software (P. Barry, University of New South Wales, Sydney, Australia; modified for Molecular Devices). Signals were filtered at 4–6 kHz through a –3 dB ...
-
bioRxiv - Neuroscience 2021Quote: ... Membrane voltages were adjusted for liquid junction potentials (approximately –14 mV) calculated using JPCalc software (P. Barry, University of New South Wales, Sydney, Australia; modified for Molecular Devices). Signals were filtered at 4–6 kHz through a –3 dB ...
-
bioRxiv - Cell Biology 2022Quote: ... Images were acquired at the 2-week endpoint (day 14 of CSE treatment) at 4X magnification using the ImageXpress confocal microscope (Molecular Devices) to observe changes to spheroid size due to compound treatment ...
-
bioRxiv - Neuroscience 2021Quote: ... All recordings were performed using a Multiclamp 700B amplifier and filtered at 4 kHz and digitized with a Digidata 1440 with pClamp 10 software for data acquisition (Axon, Molecular Devices, LLC, Sunnyvale, CA, USA). Recording pipette was filled with the same extracellular solution as the perfusion bath (2-4 MΩ resistance).
-
bioRxiv - Biophysics 2021Quote: ... Currents were digitized at a sampling rate of 5 kHz with an Axon CNS 1440A Digidata system using pCLAMP 10 (Molecular Devices, Sunnyvale, CA, USA). Each pH response was measured as the peak current after 1 minute exposure to activation buffer ...
-
bioRxiv - Neuroscience 2023Quote: ... Signals were filtered at 5 kHz and sampled at 10 kHz with a Digidata 1440A digitizer and pClamp10 software (Molecular Devices, San Jose, CA). Series resistance (3–5MΩ ...
-
bioRxiv - Microbiology 2021Quote: ... The reaction was stopped with 3M sulfuric acid 5-10 minutes after OPD addition and absorbance values were measured at a wavelength of 492nm on a spectrophotometer (Molecular Devices Emax system, Sunnyvale, CA). Absorbance values were normalized by subtracting normal/uncoated wells from antigen-coated wells at the corresponding serum dilution ...
-
bioRxiv - Microbiology 2020Quote: ... The reaction was stopped with 3M sulfuric acid 5-10 minutes after OPD addition and absorbance values were measured at a wavelength of 492nm on a spectrophotometer (Molecular Devices Emax system, Sunnyvale, CA). Absorbance values were normalized by subtracting normal wells from antigen-coated wells at the corresponding serum dilution ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ImageXpress Micro 4 epifluorescent microscope (Molecular Devices) with 20x air objective was used for recording the fluorescent images (16-bit) ...
-
bioRxiv - Neuroscience 2023Quote: ... using Clampex 10 softwarMe (pClamp 10, Molecular Devices, San Jose, USA). For evoked recordings ...
-
bioRxiv - Immunology 2021Quote: ... Calcium 5 Assay Kit (Molecular devices) for 1 h at 37° C ...
-
bioRxiv - Biophysics 2022Quote: ... 5 software (Molecular Devices LLC, UK). After flushing both chambers with DIW ...
-
bioRxiv - Neuroscience 2023Quote: ... digitized at 10 kHz using Digidata 1550A and pClamp 10 (Molecular Devices). Recordings were low pass filtered at 4 kHz ...
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass pipettes (3–4 MΩ, Molecular Devices) filled with internal solution (295–305 mOsm ...
-
bioRxiv - Neuroscience 2021Quote: ... pCLAMP 10 (Molecular Devices), Clampfit ...
-
bioRxiv - Neuroscience 2020Quote: Clampfit 10 (Molecular Devices), Prism (Graphpad) ...
-
bioRxiv - Neuroscience 2020Quote: ... PClamp 10 (Molecular Devices) and Matlab (MathWorks ...
-
bioRxiv - Cell Biology 2021Quote: ... Clampfit 10 (Molecular Devices), and SigmaPlot 12 were used to analyze data ...
-
bioRxiv - Cell Biology 2021Quote: ... Clampfit 10 (Molecular Devices), and SigmaPlot 12 were used to analyze data.
-
bioRxiv - Neuroscience 2022Quote: ... pCLAMP 10 (Molecular Devices), Clampfit ...
-
bioRxiv - Neuroscience 2020Quote: Clampfit 10 (Molecular Devices), minianalysis (Synaptosoft) ...
-
bioRxiv - Neuroscience 2020Quote: ... pCLAMP 10 (Molecular Devices), Clampfit ...
-
bioRxiv - Neuroscience 2020Quote: ... pCLAMP 10 (Molecular Devices), Clampfit ...
-
bioRxiv - Neuroscience 2023Quote: ... pCLAMP 10 (Molecular Devices), Clampfit ...
-
bioRxiv - Neuroscience 2022Quote: ... pCLAMP 10 (Molecular Devices). Data and results obtained from the clamps were indistinguishable.
-
bioRxiv - Physiology 2023Quote: ... Clampfit 10 (Molecular Devices), Excel (Microsoft Co) ...
-
bioRxiv - Neuroscience 2024Quote: ... pCLAMP 10 (Molecular Devices), Clampfit ...
-
bioRxiv - Physiology 2024Quote: ... Clampfit 10 (Molecular Devices), and SigmaPlot 15 software ...
-
bioRxiv - Neuroscience 2024Quote: ... pCLAMP 10 (Molecular Devices). Signals were filtered at 3 kHz and digitized at 10 kHz ...
-
bioRxiv - Cell Biology 2024Quote: ... Clampfit 10 (Molecular Devices) was used for data analysis ...
-
bioRxiv - Genomics 2023Quote: ... Whole-cell recordings were performed using a Multiclamp 700B amplifier (10 kHz sampling rate, 10 kHz low-pass filter) and Digidata 1440A and pClamp 10 software (Molecular Devices). Patch pipettes (4–6 MΩ ...
-
bioRxiv - Neuroscience 2023Quote: ... Data were low-pass filtered at 10 kHz and acquired at 10 kHz using Multiclamp 700B and pClamp 10 (Molecular Devices). Series and membrane resistance was continuously monitored ...
-
bioRxiv - Neuroscience 2020Quote: ... low-pass filtered at 4 kHz and digitized at 10Hz (current clamp) or 4 Hz (voltage clamp) (Digidata 1440A, Molecular devices, UK). Activation of Arch was obtained after illumination of the recorded area at 570 nm (pE-2 CoolLED excitation system ...
-
bioRxiv - Neuroscience 2020Quote: ... low-pass filtered at 4 kHz and digitized at 10Hz (current clamp) or 4 Hz (voltage clamp) (Digidata 1440A, Molecular devices, UK). Signals were analyzed offline (Clampfit software ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Calcium 4 dye was from Molecular devices (CA, USA). Assay buffer (physiology saline solution - PSS ...
-
bioRxiv - Neuroscience 2023Quote: ... and recorded with a 10 kHz sampling rate using pClamp 10 software (Molecular Devices). After achieving whole-cell configuration in voltage-clamp mode (−70 mV) ...
-
bioRxiv - Neuroscience 2020Quote: ... pCLAMP 10 software (Molecular Devices) was used for data acquisition and analysis ...
-
bioRxiv - Neuroscience 2021Quote: ... with Clampex 10 (Molecular Devices) and analyzed with pClamp 10 (Molecular Devices) ...
-
bioRxiv - Neuroscience 2021Quote: ... and pClamp 10 (Molecular Devices), using appropriate bridge balance and electrode-capacitance compensation ...
-
bioRxiv - Neuroscience 2023Quote: ... pClampfit 10 (Molecular Devices, U.S.A.), or MiniAnalysis (6.0.3 Synaptosoft ...
-
bioRxiv - Neuroscience 2023Quote: ... pClamp 10 software (Molecular Devices) was used for visualization and analysis of recorded traces.