Labshake search
Citations for Molecular Devices :
801 - 850 of 1317 citations for Copper;5 10 15 20 tetrakis 4 methylphenyl porphyrin 22 24 diide since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
Kir6.1, a component of an ATP-sensitive potassium channel, regulates natural killer cell developmentbioRxiv - Immunology 2024Quote: ... and data were acquired at 10 kHz (Digidata 1550A and Clampex 10.7; Molecular Devices). The bath solution consisted of (in mM ...
-
bioRxiv - Neuroscience 2024Quote: ... and digitized at 10 kHz using a patch-clamp amplifier (Multiclamp 700B, Molecular Devices). Nearly all recordings were made using 3-5 MΩ borosilicate pipettes (Sutter ...
-
bioRxiv - Neuroscience 2024Quote: ... and digitized using a Digidata 1440A and the Clampex 10 program suite (Molecular Devices). Cells were only accepted for analysis if the initial series resistance was less than 40 MΩ and did not change by more than 20% during the recording period ...
-
bioRxiv - Neuroscience 2024Quote: ... Recordings were digitized on-line and filtered at 10 kHz (Digidata 1550B, Molecular Devices). Pipette and neuronal capacitive currents were canceled and ...
-
bioRxiv - Neuroscience 2021Quote: ... The data was digitized at 5–500 kHz using an analog-to-digital converter (Digidata 1500; Molecular Devices). The sampling frequency was determined by the protocol used ...
-
bioRxiv - Neuroscience 2021Quote: ... The data were digitized at 5–500 kHz using an analog-to-digital converter (Digidata 1500; Molecular Devices). The whole-cell current recordings were done using pCLAMP software (version 10 ...
-
bioRxiv - Neuroscience 2021Quote: ... Signals were filtered at 5 kHz with the patch-clamp amplifier (Axopatch 1-D, Molecular Devices, Sunnyvale, CA) and sampling rate was adjusted according to the kinetics of membrane current ...
-
bioRxiv - Neuroscience 2021Quote: ... Signals were filtered at 5 kHz using a Digidata 1500A data acquisition interface (Molecular Devices, San Jose, CA) and acquired using pClamp 10.6 software (Molecular Devices) ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell measurements were low-pass filtered at 5 kHz using an Axopatch 200B amplifier (Molecular Devices, Inc). Recordings were digitized with the ITC-18 board (Instrutech ...
-
bioRxiv - Biochemistry 2024Quote: ... bioluminescence data were collected for ∼5 min on a SpectraMax iD3 plate reader (Molecular Devices, Sunnyvale, CA, USA). Subsequently ...
-
bioRxiv - Bioengineering 2023Quote: ... and performing an absorbance spectral scan (200–1000 nm; 5 nm increments) using a Spectramax M3 (Molecular Devices).
-
bioRxiv - Biochemistry 2023Quote: ... Samples were incubated at RT for 5 min before fluorescence was measured using a SpectraMax M5 (Molecular Devices) microplate reader with excitation/emission maxima at 490/520 nm ...
-
bioRxiv - Neuroscience 2024Quote: ... low-pass filtered (5 KHz) and digitised (Axopatch-200B, custom amplifier/filters, Digidata 1440, Clampex software; Molecular Devices). Pipettes and electrodes were positioned with Sutter MP265 and 285 manipulators with a diagonal (axial ...
-
bioRxiv - Neuroscience 2024Quote: ... Signals were filtered at 5 kHz using a Digidata 1500B data acquisition interface (Molecular Devices, San Jose, CA) and acquired using pClamp 10.6 software (Molecular Devices) ...
-
bioRxiv - Cell Biology 2021Quote: ... The cells were then washed 4 times with fresh pre-warmed Tyrode’s solution and automatically imaged with an ImageXpress Micro XLS microscope (Molecular Devices) at an acquisition frequency of 100 Hz for a duration of 5 s with excitation 485/20 nm and emission 525/30 nm filters ...
-
bioRxiv - Neuroscience 2023Quote: ... both connected to a 2-way 4-port electric rotary valve (Bio-Chem Fluidics) and the pClamp 10.6 software (Molecular Devices).
-
bioRxiv - Biochemistry 2024Quote: ... and bioluminescence data were immediately collected for ∼4 min on a SpectraMax iD3 plate reader (Molecular Devices, Sunnyvale, CA, USA) with an interval of 11 s ...
-
Structural and functional organization of visual responses in the inferior olive of larval zebrafishbioRxiv - Neuroscience 2021Quote: ... duration of 1s and magnitude of 20-30 V were applied to inject DNA constructs into a single cell using an Axoporator 800A (Molecular Devices, Silicon Valley, CA). After electroporation ...
-
bioRxiv - Bioengineering 2020Quote: ... and digitized at a sample rate of 20 kHz via a Digidata 1440A A/D digitizer (both Axon Instruments/Molecular Devices, Union City, CA). All recordings were performed at room temperature ...
-
Dynamic Effects of Ventral Hippocampal NRG3/ERBB4 Signaling on Nicotine Withdrawal-Induced ResponsesbioRxiv - Neuroscience 2023Quote: Currents were low pass filtered at 2 kHz and digitized at 20 kHz using a Digidata 1550B acquisition system (Molecular Devices, San Jose, CA) coupled to the Multiclamp 700B amplifier (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... Recordings were done by impaling body-wall muscle 6-7 in abdominal segment 3 with a 20-25 MÙ electrode and were amplified using an Axoclamp 900A amplifier (Molecular Devices, San Jose, CA). Recordings were exported to a computer using an Axon Digidata 1550B (Molecular Devices ...
-
bioRxiv - Cell Biology 2022Quote: ... and the 340/11 nm/380/20 nm ratios were measured for each ROI using MetaMorph image analysis software (Molecular Devices, San Jose, CA). Single-cell Ca2+ traces were normalized to their respective baseline intracellular Ca2+ level obtained by averaging the 340/11 nm/380/20 nm ratios during the first minute of each experiment in the absence of stimulus ...
-
bioRxiv - Microbiology 2022Quote: ... The plates were read between 20-24hrs following inoculation with a pre-grown isolate using spectrophotometer microplate reader (Molecular Devices, LLC, San Jose, CA) and reading data acquisition was performed using SoftMax Pro 7 software (Molecular Devices ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell and cell-attached patch-clamp recordings were obtained from RGCs (soma diameter ≥ 20 µm) using an Axopatch 200B amplifier (Molecular Devices, San José, CA). For current-clamp recordings (I = 0 ...
-
bioRxiv - Neuroscience 2021Quote: ... Peak current amplitudes were searched identified manually using pCLAMP 10 (Molecular Devices, San Jose, CA), and visually monitored to exclude the erroneous noise ...
-
bioRxiv - Neuroscience 2020Quote: ... amplified and filtered (10 kHz low pass bessel) using an Axopatch 200B amplifier (Molecular Devices), digitized at 100 kHz and stored on disk for offline analysis.
-
bioRxiv - Biophysics 2021Quote: ... Recordings were filtered at 1 kHz and digitized at 10 kHz (Digidata 1440A; Molecular Devices). Pressure application through patch pipettes was performed with a high-speed pressure clamp (ALA Scientific ...
-
bioRxiv - Neuroscience 2022Quote: ... The data was digitized using a Digidata 1440B digitizer using pClamp 10 (Molecular Devices, USA). Coverslips containing transfected HEK293T cells were perfused with an external solution containing the following (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Data were digitized at 10 kHz and analyzed on-line using pClamp software (Molecular Devices). All values were reported as means ± standard errors of the mean ...
-
bioRxiv - Neuroscience 2020Quote: ... for acquisition (1-10 kHz) by pCLAMP10.2 software (Molecular Devices, LLC, San Jose, CA, USA). Glass recording microelectrodes were filled with aCSF (tip resistance ∼3MΩ ...
-
bioRxiv - Neuroscience 2020Quote: ... Electrophysiological data were acquired and analyzed using pClamp 10 software (Molecular Devices, San Jose, USA). Whole-cell recordings were performed with borosilicate glass electrodes (0.69 mm OD ...
-
bioRxiv - Neuroscience 2020Quote: ... the signal was amplified by 10 fold in axoClamp 2B (in bridge mode; Molecular Devices). Then ...
-
bioRxiv - Neuroscience 2020Quote: ... and digitized at 10 kHz using a MultiClamp 700B amplifier and Digidata 1550 (Molecular Devices). Clampex 11.4 software (Molecular Devices ...
-
bioRxiv - Neuroscience 2021Quote: Data were acquired using PCLAMP 10 and a Multiclamp 700B amplifier (Molecular Devices, Sunnyvale, CA), low-pass filtered at 4 kHz and digitized at 10 kHz ...
-
Audiovisual stimuli enhance narrowband gamma activity along the mouse thalamocortical visual circuitbioRxiv - Neuroscience 2023Quote: ... digitalized at 10 kHz (Axon Digidata 1550 B; Molecular Devices, LLC. San Jose, CA, USA) and visualized with the pClamp 11 software (Molecular Devices).
-
bioRxiv - Physiology 2023Quote: ... digitized and sampled at 10 kHz with an A/D board (Digidata 1550, Molecular Devices). Recordings were acquired using the software PClamp 10.4 (Molecular Devices).
-
bioRxiv - Neuroscience 2022Quote: ... filtered at 3 kHz and sampled at 10 kHz using a Digidata 1550 (Molecular devices). All recordings were carried out in current-clamp mode ...
-
bioRxiv - Neuroscience 2022Quote: ... Data acquisition and analysis were performed with Digidata 1440A and software pCLAMP 10 (Molecular Devices). Skatole (98% ...
-
bioRxiv - Biophysics 2024Quote: ... Voltage clamp control and data acquisition were under software control (pClamp version 10, Molecular Devices). All experiments were performed at 18-20 °C ...
-
bioRxiv - Neuroscience 2024Quote: ... and stored and analyzed on computer using pCLAMP 9 and Clampfit 10 software (Molecular Devices).
-
bioRxiv - Neuroscience 2024Quote: ... Voltage clamp control and data acquisition were under software control (pClamp version 10, Molecular Devices). All experiments were performed at 18-20°C ...
-
bioRxiv - Neuroscience 2024Quote: ... amplified and filtered (10 kHz low pass bessel) using an Axopatch 200B amplifier (Molecular Devices) and digitized at 100 kHz ...
-
bioRxiv - Neuroscience 2023Quote: ... Traces were analyzed while blinded to the experimental conditions using Clampfit 10 software (Molecular Devices). mEPSCs / mIPSCs were automatically detected in a template-based search and visually inspected for inclusion or rejection.
-
bioRxiv - Physiology 2024Quote: ... Acquisition was done using the Clampex 10 software driving an Axon Digidata 1550 (Molecular Devices). Data were analyzed with Clampfit 10 (Molecular Devices ...
-
bioRxiv - Biochemistry 2022Quote: ... Fluorescent spectra were recorded every 10 minutes for 24hours with a SpectraMax i3 (Molecular Devices). For each well ...
-
bioRxiv - Biophysics 2024Quote: ... mEPSCs were analyzed using a mEPSC current-template search through Clampfit 10 software (Molecular Devices), with a detection threshold of -6 pA.
-
bioRxiv - Neuroscience 2024Quote: ... collected at a sampling rate of 10 kHz with a Multiclamp 700B amplifier (Molecular Devices), low-pass filtered at 3 kHz and digitized with a digital-to-analog converter board (National Instruments ...
-
bioRxiv - Biophysics 2024Quote: ... Recordings were stored directly onto a computer hard drive using Clampex 10 software (Molecular Devices). For recording of Kv currents in heterologous cells ...
-
bioRxiv - Neuroscience 2024Quote: ... low pass filtered at 10 kHz and digitized using a Digidata 1322A digitizer (Molecular Devices). Slow and fast capacitive components were semi-automatically compensated ...
-
bioRxiv - Cell Biology 2020Quote: ... Each sample was split into 4 wells of a 384 well clear bottom polystyrene plate and read on a Spectramax M2 plate reader (Molecular Devices) at 37°C ...