Labshake search
Citations for Molecular Devices :
651 - 700 of 801 citations for Dendritic Cell Specific Transmembrane Protein DCSTAMP Antibody Biotin since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: Whole-cell patch-clamp recordings were performed close to physiological temperature (33-35°C) using a Multiclamp 700B amplifier (Molecular Devices) and fire-polished thick-walled glass patch electrodes (1.85 mm OD ...
-
bioRxiv - Microbiology 2023Quote: ... the cell culture samples were taken at different time points to determine growth spectrophotometrically (SpectraMax M2, Molecular Devices, San Jose, CA) by measuring absorbance at 600 nm (OD600) ...
-
bioRxiv - Physiology 2023Quote: ... The current was induced with a 500 ms depolarization step at 0 mV from the holding potential of −60 mV using barium as the charge carrier and was sampled at 10 kHz and filtered at 2 kHz in the whole-cell voltage patch-clamp configuration with an Axopatch 200B amplifier (Molecular Devices). Peak and residual currents were obtained with Clampfit software (Molecular Devices) ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole cell patch-clamp recordings were made under current-clamp using a Multiclamp 700B amplifier (Molecular Devices, California, USA, RRID: SCR_014300). Recordings were low pass filtered at10 kHz and acquired at 25 kHz with CED Power 1401 AD board and displayed and recorded using Signal software (Cambridge Electronic Design ...
-
bioRxiv - Neuroscience 2023Quote: ... Extranuclear DNA-histone complexes were measured with Cell Death Detection ELISAPlus at 405 nm using the SpectraMax i3x Multi-Mode Microplate Reader (Molecular Devices). Results are expressed as percent change compared with untreated control cells.
-
bioRxiv - Biochemistry 2023Quote: Single-channel currents from devitalized injected oocytes were measured by the cell-attached patch-clamp technique using an Axopatch 200B amplifier (Molecular Devices)(53) ...
-
bioRxiv - Microbiology 2023Quote: ... Images encompassing the central 50% of the well were analyzed using a ImageXpress Pico Automated Cell Imaging System software (Molecular Devices). Representative images were prepared using Fiji ...
-
bioRxiv - Neuroscience 2023Quote: ... Stable whole-cell recordings were acquired at 100 kHz in pClamp 10.3 and pClamp 10.7 (Molecular Devices, San Jose, CA, USA) via an Axon 700B multiclamp amplifier and Digidata 1440 digitizer ...
-
bioRxiv - Biochemistry 2023Quote: The mitochondrial membrane potential in cells was measured with TMRE using the Image Xpress Micro Confocal high-content imaging system (Molecular Devices). NRVMs and iPSC-derived iCell cardiomyocytes were plated onto collagen-coated ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... cells were grown on 12-mm coverslips and whole cell voltage-clamp recordings were performed at room temperature (22-24 °C) with a patch-clamp amplifier (Axopatch 200B, Molecular Devices) using a 5 kHz low-pass filter and a sampling rate of 20 kHz ...
-
bioRxiv - Physiology 2022Quote: Glucose responsiveness of AVP neurons was then assessed in the whole-cell configuration using a MultiClamp 700B amplifier associated with a 1440A Digidata digitizer (Molecular Devices). Borosilicate glass pipettes (resistance ...
-
bioRxiv - Neuroscience 2022Quote: The analysis of the monosynaptic responses evoked by the light stimulation of EC or VMT inputs on CA1 slm GABAergic neurons and pyramidal cells was performed using Clampfit 10 (Molecular Devices). We measured the delay between the onsets of the light pulse and the cell response and its amplitude ...
-
bioRxiv - Neuroscience 2022Quote: ... Whole-cell patch clamp recordings were then made at the soma of CHR2-YFP+ MNs using a Multiclamp 700B amplifier (Molecular Devices) and the data acquired using a Digidata 1440A digitizer (Molecular Devices) ...
-
bioRxiv - Neuroscience 2022Quote: ... Whole-cell recordings from layers II/III GC neurons were performed with an Multiclamp 700B amplifier (Molecular Devices, San Jose, CA) in voltage-clamp (Vhold = −60mV ...
-
bioRxiv - Cell Biology 2024Quote: Invasion assays were quantified in cells stained with Phalloidin and DAPI and an ImageXpress Confocal High-Content Imaging System Confocal (Molecular Devices).
-
bioRxiv - Biophysics 2024Quote: ... Whole cell membrane currents of oocytes were measured using a two-electrode voltage clamp (Gene Clamp 500B, Axon Instruments/Molecular Devices) under constant perfusion according to the protocols described in the figures ...
-
bioRxiv - Neuroscience 2024Quote: ... Somatic whole-cell voltage-clamp recordings (¿1 GΩ seal resistance, -70 mV holding potential) were performed using a Multiclamp 700B amplifier (Molecular Devices). Data were acquired using pCLAMP 10.7 on a personal computer connected to the amplifier via a Digidata-1440 interface (sampling rate ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell patch-clamp recordings were performed close to physiological temperature (32–34 °C) using a Multiclamp 700B amplifier (Molecular Devices) and fire-polished thick-walled glass patch electrodes (1.85 mm OD ...
-
bioRxiv - Cancer Biology 2023Quote: ... The percentage of viable cells at each concentration was estimated by the absorbance at 450 nm using a Microplate Reader (SpectraMax M5, Molecular Devices). IC50 value for each chemo drug was determined using GraphPad Prism (version 10.0.2).
-
bioRxiv - Neuroscience 2023Quote: ... current clamp recordings targeted FusionRed/mCherry expressing cells were performed using an Axopatch 700B amplifier and a Digidata 1440A data acquisition system (Molecular Devices) on an Olympus upright microscope (BX51WIF ...
-
bioRxiv - Neuroscience 2023Quote: ... were measured in GluK1 and GluK2 expressing cells cultured in 96-well plates using a FlexStation I plate reader (Molecular Devices).
-
bioRxiv - Pharmacology and Toxicology 2024Quote: Whole-cell patch-clamp measurements were performed on transfected HEK293 cells expressing rat version of the GluN1-4a/GluN2A (GluN1/GluN2A) receptors using an Axopatch 200B amplifier (Molecular Devices) as described 25,51 ...
-
bioRxiv - Neuroscience 2023Quote: ... The current traces of the cell-attached recordings were recorded in voltage-clamp mode using a Axopatch 200B amplifier (Molecular Devices), digitized at 40 kHz (National Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... Spontaneous synaptic activity and evoked responses were recorded at room temperature (21-23 °C) in whole-cell conditions using a MultiClamp 700B amplifier (Molecular Devices). Intracellular voltage and current traces were sampled at 20 kHz and stimulus command waveforms were generated by the data acquisition software DASYLab v.11 (National Instruments) ...
-
bioRxiv - Developmental Biology 2022Quote: ... 50 µL of CellTiterGlo reagent and buffer mix was added to 50 µL of cell media in each well and luminescence was measured by SpectraMax M3 (Molecular Devices,).
-
bioRxiv - Bioengineering 2022Quote: Action potential recording was recorded by patch clamp under a whole-cell configuration using Axon 700B amplifier system (Molecular Devices, USA). The pipette solution contained (in mmol/L) ...
-
bioRxiv - Neuroscience 2022Quote: ... Action potential deflections in cell-attached configuration and voltage/current recordings under whole-cell configuration were sampled at 5kHz (low pass filter 2kHz; Axograph X, Molecular Devices). Data from cell-attached and whole-cell recordings were only included in analyses if (1 ...
-
bioRxiv - Neuroscience 2022Quote: ... was added to the cells and absorbance was measured at 570 nm via a SpectraMax iD5 MultiMode Microplate Reader (Molecular Devices). Ferroptotic cell death was monitored continuously using the IncuCyte (Essen Biosciences) ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings (electrode resistance 5-9 MΩ) were performed at room temperature using a Multiclamp 700B amplifier (Molecular Devices). Layer 2/3 chandelier cells were patched in current-clamp configuration using potassium-based internal solution (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... the IK12 and IA formulations were converted to Cybercyte channel definition files using Cybersolver software and validated by applying the simulated currents to a model cell (Molecular Devices) with an input resistance of 500 MΩ and a capacitance of 30 pF in whole-cell mode ...
-
bioRxiv - Neuroscience 2023Quote: ... Cell migration speed and distances were analysed by tracing at least 6 cells per slice using the motion tracking function in MetaMorph software (Molecular Devices).
-
bioRxiv - Animal Behavior and Cognition 2022Quote: ... and patched in the whole-cell (4-8 MΩ electrode resistance; 20-40 MΩ series resistance) current clamp configuration (MultiClamp 700B, Molecular Devices). Using a potassium-based internal solution (136mM K-gluconate ...
-
bioRxiv - Cell Biology 2023Quote: Time-lapse live-cell imaging related to the knockdown-rescue experiments was performed on an ImageXpress Nano Automated Imaging System (Molecular Devices). A SOLA Light Engine (Lumencor ...
-
bioRxiv - Physiology 2024Quote: ... Data were collected from at least three independent passages from each cell line and analysed using Clampfit 11 software (Molecular Devices). Nifedipine and mibefradil were solubilized in dimethyl sulfoxide (DMSO ...
-
bioRxiv - Physiology 2024Quote: Electrophysiological measurements by whole-cell patch-clamp were performed on H295R-S2 control cells and clones 17 and 42 using an Axopatch 200B amplifier (Molecular Devices) controlled by Axon pClamp 11 software through an A/D converter (Digidata 1550B ...
-
bioRxiv - Systems Biology 2024Quote: Cells that contained the red GEDI biosensor were imaged on an ImageXpress Micro Confocal High-Content Imaging System from Molecular Devices for 7-10 days starting on differentiation day 7 ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell configuration patch clamp recordings were conducted in HEK293T cells and cultured neurons using an amplifier (EPC 800, HEKA) and a digitizer (Digidata 1550A, Molecular Devices). The signals were sampled at 20 kHz and filtered at 5 kHz ...
-
bioRxiv - Immunology 2024Quote: ... Staining solution was replaced by live-cell visualization medium DMEMgfp-2 with 10 % FCS and images were acquired with a MetaXpress Micro XL system (Molecular Devices) at 20 x magnification.
-
bioRxiv - Immunology 2024Quote: ... Cells were stained for IE-1 expression and DAPI 12 days post infection and images were acquired and analyzed using the ImageExpress Pico Automated Cell Imaging Platform as previously described (Molecular Devices). Data was reported as the reduction in virus spread ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell patch-clamp recordings were performed in PV-INs and pyramidal cells (PYRs) in V1 using a Multiclamp 700A amplifier (Molecular Devices). To identify PV-INs ...
-
bioRxiv - Neuroscience 2024Quote: ... Voltage-clamp recordings were done holding the cell at a membrane potential of −70mV using a MultiClamp 700B patch-clamp amplifier (Molecular Devices) filtered at 2.8kHz and digitized at 20kHz ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell patch-clamp recordings were performed close to physiological temperature (32–34°C) using a Multiclamp 700B amplifier (Molecular Devices) and fire-polished thick-walled glass patch electrodes (1.85 mm OD ...
-
bioRxiv - Neuroscience 2024Quote: ... Whole-cell patch clamp on OHCs were conducted with a holding potential of -70 mV (Axon Axopatch 700B, Molecular Devices Corp.). Sinusoidal fluid jet stimuli at 40 Hz were produced using a 27-mm-diameter piezoelectric disc.
-
bioRxiv - Neuroscience 2024Quote: Whole-cell patch-clamp recordings were amplified and digitized using an EPC-9 (HEKA Electronik GmbH) or MultiClamp 700B (Molecular Devices) and Digidata 1550B (Molecular Devices ...
-
bioRxiv - Neuroscience 2024Quote: ... current-clamp whole-cell recordings on NAc neurons were performed using an Axon MultiClamp 700B amplifier (Molecular Devices, San Jose, CA). Borosilicate glass pipettes pulled on a P-97 Puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... Voltage-clamp recordings in the whole-cell configuration were performed using an Axopatch-200B amplifier (Molecular Devices LLC, San Jose, CA) with a holding potential of −70 mV.
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... iCa2+ mobilisation was measured as a change in fluorescence of the cell permeable Ca2+ indicator dye Fluo-8AM at room temperature using Flexstation I and/or III (Molecular Devices) as described previously (Gregory et al. ...
-
bioRxiv - Neuroscience 2024Quote: ... Whole-cell patch clamp measurements were recorded at 28°C using a MultiClamp 700B amplifier and Digidata 1550B digitizer (Molecular Devices). The recorded signals were filtered at 6 kHz and digitalized at 20 kHz ...
-
bioRxiv - Molecular Biology 2024Quote: ... Image acquisition of fluorescently labeled cells was performed with the ImageXpress Micro High-Content Screening (HCS) Microscopy system (Molecular Devices, LLC), and image analysis was carried out using the MetaXpress 3.1 software (Molecular Devices) ...
-
bioRxiv - Neuroscience 2024Quote: ... Cells were visualized on an upright microscope using “Dodt-type” gradient contrast infrared optics and whole-cell recordings were made using a MultiClamp 700B amplifier (Axon Instruments, Molecular Devices). Recording electrodes (3-5 MΩ ...