bioRxiv - Biophysics 2022Quote: ... All recordings were voltage-clamped at −60 mV and data collected at 5 kHz using an Axopatch 200B amplifier and Digidata 1440A (Molecular Devices, San Jose, CA). Rapid application or washout of agonist were performed using a three-barreled flowpipe mounted to and controlled by a SF-77B fast perfusion system (Warner Instrument Corporation ...
-
bioRxiv - Neuroscience 2022Quote: ... Signals were recorded using a 5 KHz low-pass filter at a sampling frequency of 20 KHz using the Digidata 1440A digitizer (Molecular devices, Sunnyvale, CA, USA) with Clampex (v10.6 ...
-
bioRxiv - Neuroscience 2022Quote: ... Signals were recorded using a 5 KHz lowpass filter at a sampling frequency of 20 kHz using the Digidata 1440A digitizer (Molecular devices, Sunnyvale, CA, USA) with Clampex (v10.6 ...
-
bioRxiv - Neuroscience 2022Quote: ... Recordings were filtered at 5 kHz with the amplifier internal filter and digitized at 50 kHz using a Digidata 1550B digitizer (Molecular Devices, San Jose, CA). The recording pipette was filled with (in mM) ...
-
Development of monoclonal antibody-based blocking ELISA for detecting SARS-CoV-2 exposure in animalsbioRxiv - Microbiology 2023Quote: ... MA) in 5 min and color intensity was quantified at 405 nm using a SpectraMax® iD5 microplate reader (Molecular Devices, San Jose, CA). The percentage of inhibition was calculated using the following formula:
-
bioRxiv - Neuroscience 2023Quote: ... Signals were filtered at 5 kHz and sampled at 10 kHz with a Digidata 1440A digitizer and pClamp10 software (Molecular Devices, San Jose, CA). Series resistance (3–5MΩ ...
-
bioRxiv - Neuroscience 2022Quote: ... Signals were filtered at 200 Hz and digitized at 1 kHz with the MiniDigi 1 digitizer (Molecular Devices) for simultaneous continuous recording of DC potential ...
-
bioRxiv - Physiology 2023Quote: ... Channel currents were recorded at 1 kHz with an Axopatch 1-D amplifier (Molecular Devices Inc., Sunnyvale, CA) with a low-pass 100-Hz 8-pole Bessel filter ...
-
bioRxiv - Immunology 2021Quote: ... The concentration of both mouse and simian IgG antibodies was calculated relative to the standard using a 5-parameter fit curve (Softmax, Molecular Devices, Sn Jose, CA, USA) and results are expressed as µg/mL of HIV-specific antibodies (IgG ...
-
bioRxiv - Immunology 2021Quote: ... Plates were incubated for 5-15 minutes at room temperature and luminescence was measured on a Spectramax i3x plate reader (Molecular Devices, San Jose, CA, USA). Data analysis was performed using the Softmax Pro (Molecular Devices ...
-
bioRxiv - Physiology 2021Quote: Whole-cell membrane currents were filtered at 2 kHz using the low-pass Bessel filter of the Axopatch 200B amplifier and digitized (5-10 kHz) using a Digidata 1440 unit and pCLAMP 10 software (Molecular Devices, San Jose, CA, USA). Patch electrodes were pulled from borosilicate glass and heat-polished to a final resistance between 3 and 5 MΩ ...
-
bioRxiv - Microbiology 2021Quote: ... The reaction was stopped with 3M sulfuric acid 5-10 minutes after OPD addition and absorbance values were measured at a wavelength of 492nm on a spectrophotometer (Molecular Devices Emax system, Sunnyvale, CA). Absorbance values were normalized by subtracting normal/uncoated wells from antigen-coated wells at the corresponding serum dilution ...
-
bioRxiv - Microbiology 2020Quote: ... The reaction was stopped with 3M sulfuric acid 5-10 minutes after OPD addition and absorbance values were measured at a wavelength of 492nm on a spectrophotometer (Molecular Devices Emax system, Sunnyvale, CA). Absorbance values were normalized by subtracting normal wells from antigen-coated wells at the corresponding serum dilution ...
-
bioRxiv - Immunology 2023Quote: ... The optical density was read at 450 nm using a Versamax microplate reader with SoftMax Pro Version 5 (both from Molecular Devices; San Jose, CA, USA), and endpoint titers were calculated with a cutoff three times the optical density over background ...
-
bioRxiv - Cell Biology 2024Quote: ... was obtained for ratiometric analysis at 37 °C with sampling every 5 minutes for two hours in a microtiter plate reader (Molecular Devices ID3, San Jose CA, USA). The calcium ionophore ionomycin (10 µM ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... background reaction rates were measured by tracking the change in absorbance at 412 nm over 5 min using a SpectraMax® iD3 Multi-Mode Microplate Reader (Molecular Devices, LLC., San Jose, CA, USA). After the addition of oxaloacetate to start the reaction ...
-
bioRxiv - Biochemistry 2020Quote: ... Data were collected on a BLItz instrument and analyzed with a 1:1 binding model using BLItz Pro Data Analysis Software (Molecular Devices). The assay buffer was 10 mM HEPES pH 7.6 ...
-
bioRxiv - Biochemistry 2020Quote: BLI kinetics were collected on an Octet RED96a and analyzed with a 1:1 binding model (global fit) using instrument software (Molecular Devices). IgG1 Fc-fused sACE22 (wild type or engineered variant sACE22.v2.4 ...
-
bioRxiv - Microbiology 2020Quote: ... and filtered at 1 kHz (Digidata 1550A, Molecular Devices). All experiments were performed at −60 mV holding membrane potential (Vh ...
-
bioRxiv - Neuroscience 2021Quote: ... A patch-clamp headstage (Molecular Devices #1-CV-7B) mounted on a motorized 4-axis Siskiyou MX7600 manipulator ...
-
bioRxiv - Neuroscience 2020Quote: Recordings were made using an Axopatch 1-D (Molecular Devices), filtered at 5 kHz and collected at 20 kHz using custom procedures written for NIDAQ and IGOR Pro (National Instruments and WaveMetrics ...
-
bioRxiv - Neuroscience 2019Quote: ... were digitized at 1 kHz using a Digidata 1440a (Molecular Devices).
-
bioRxiv - Cell Biology 2020Quote: ... digitized at 1 kHz using MiniDigi 1A (Molecular Devices, CA, USA) and analyzed using pCLAMP 9 (Molecular Devices).
-
bioRxiv - Neuroscience 2023Quote: ... RMP was sampled every 1 s using Clampfit 10.7 (Molecular Devices) and binned into 30 s increments ...
-
bioRxiv - Biophysics 2024Quote: ... and digitized at 1 kHz using Digidata 1550B digitizer (Molecular Devices). Representative traces and dose response plots were generated in GraphPad Prism 9 (GraphPad Software ...
-
bioRxiv - Bioengineering 2023Quote: ... filtered at 1 kHz and digitized at 10 kHz (Digidata 1440; Molecular devices). Recordings were made in the outside-out excised patch configuration after gigaseals were obtained and currents were recorded by voltage ramp protocols from −100 to +100mV with and without 10 mM capsaicin addition by perfusion (ALA Scientific VM8 manifold perfusion system).
-
bioRxiv - Bioengineering 2023Quote: ... which was inserted in a micropipette holder (1-HL-U, Molecular Devices LLC) fixed on a stereotaxic stage equipped with a motorized linear translation stage (860A motorizer and 460A linear stage ...
-
bioRxiv - Neuroscience 2024Quote: ... filtered at 1 kHz and digitized at 10 kHz (Digidata 1440; Molecular devices). Recordings were made in the outside-out excised patch configuration after gigaseals were obtained and currents were recorded by voltage ramp protocols from -100 to +100mV with and without 10 mM capsaicin addition by perfusion (ALA Scientific VM8 manifold perfusion system).
-
bioRxiv - Neuroscience 2019Quote: ... and digitized at 1 kHz (CyberAmp 380, Digidata 1440A, AxoScope 10 software, Molecular Devices). EEG synchronized video recordings (Logitech Software and Cerberus 4.0 Beta ...
-
bioRxiv - Biophysics 2021Quote: ... Currents were amplified and low-pass filtered at 1 kHz (Axopatch 200B, Molecular Devices), digitized at a sampling rate of 10 kHz (Digidata 1550B ...
-
bioRxiv - Cancer Biology 2022Quote: ... Traces were digitized at 1 kHz using the Digidata 1322A interface (Molecular Devices, USA) using Clampex 9.2 software (Molecular Devices ...
-
bioRxiv - Cell Biology 2023Quote: ... 1-ms pulse width) and the acquisition sequence driven by MetaMorph Software (Molecular Devices) or Zeiss Zen2 software at 5 Hz frequency ...
-
bioRxiv - Molecular Biology 2023Quote: ... using 50 Hz low-pass filters and digitization at 1 kHz (Molecular Devices, USA). The stock solutions (1 M ...
-
bioRxiv - Biophysics 2021Quote: ... Recordings were filtered at 1 kHz and digitized at 10 kHz (Digidata 1440A; Molecular Devices). Pressure application through patch pipettes was performed with a high-speed pressure clamp (ALA Scientific ...
-
bioRxiv - Neuroscience 2020Quote: ... for acquisition (1-10 kHz) by pCLAMP10.2 software (Molecular Devices, LLC, San Jose, CA, USA). Glass recording microelectrodes were filled with aCSF (tip resistance ∼3MΩ ...
-
bioRxiv - Neuroscience 2019Quote: ... filtered at 1 kHz and analyzed offline using pClamp10 software (Molecular Devices, Sunnyvale, CA, USA).
-
bioRxiv - Neuroscience 2019Quote: ... filtered at 1 kHz and analyzed offline using pClamp10 software (Molecular Devices, Sunnyvale, CA, USA).
-
bioRxiv - Neuroscience 2024Quote: ... Electrical signals were filtered at 1 kHz by a Multiclamp 700B amplifier (Molecular Devices, USA), and digitized by an Axon DigiData 1550A converter with a sampling frequency of 10 kHz ...
-
bioRxiv - Neuroscience 2023Quote: ... Recorded currents were filtered at 1 kHz and digitized by a Digidata 1550A (Molecular Devices) digitizer at a sampling rate of 10 kHz ...
-
bioRxiv - Neuroscience 2021Quote: ... whole-cell patch-clamp recordings were performed with an Axopatch 1-D amplifier (Molecular Devices, USA) operated with Clampex 9.2 software and a DigiData 1200 series interface (Molecular Devices ...
-
bioRxiv - Neuroscience 2020Quote: ... The data was low-pass filtered at 1 kHz (Molecular devices DigiData 1440A and Multiclamp 700B). Pipette series resistance and membrane holding current were monitored throughout all recordings to ensure stability of the recording.
-
bioRxiv - Physiology 2022Quote: ... Membrane voltage was obtained by using an Axoclamp 1-D amplifier (Molecular Devices, Sunnyvale, CA, USA) connected to a Digidata 1440A (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... at a sampling rate of 1 kHz and acquired using Clampex software (v. 10.7, Molecular Devices). To temporally match the EEG/EMG data with two-photon images ...
-
bioRxiv - Biochemistry 2020Quote: ... Cell Signaling Technology) as the primary antibody (1:2000 dilution) and ScanLater anti-rabbit antibody (Molecular Devices) as the secondary antibody (1:5000 dilution) ...
-
bioRxiv - Cell Biology 2021Quote: ... spin-dried (200 g for 1 min) and scanned with a Genpix 4000B microarray scanner (Molecular Devices, made available by EMBL Genomics Core Facility) ...
-
bioRxiv - Neuroscience 2022Quote: ... were filtered at 1 kHz and digitized at 10 kHz with Digidata 1322A interface board (Molecular Devices) to record fEPSPs ...
-
bioRxiv - Biophysics 2021Quote: ... The reference electrode was a grounded Ag/AgCl pellet electrode (1-HLA-003, Molecular devices, California, USA). Borosilicate glass pipettes with filaments (BF150-86-7.5 ...
-
bioRxiv - Biophysics 2021Quote: ... a chlorinated silver wire (0.25 mm in thickness) was used (1-HLA-005, Molecular Devices, California, USA). The electrode was regularly abraded with sandpaper and immersed in commercial bleach solution for about 30 min in order to keep it chlorinated ...
-
bioRxiv - Neuroscience 2022Quote: ... Data were sampled at 1 kHz and recordings were analyzed offline using PClamp10 software (Molecular Devices, USA). Breathing frequency was calculated on a breath-to-breath basis ...
-