Labshake search
Citations for Electron Microscopy Sciences :
1 - 50 of 79 citations for Rat Proto oncogene Mas MAS1 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: ... or rat-anti-CD63 (MBL, D263-3)) in 0.1% BSAc (Electron Microscopy Sciences) for 1 h ...
-
bioRxiv - Cell Biology 2024Quote: Primary rat and mouse cardiomyocytes were fixed in 4% PFA (Electron Microscopy Sciences) for 10 min ...
-
bioRxiv - Microbiology 2021Quote: ... and 10nm gold bead conjugated goat anti-rat (Electron Microscopy Sciences, 1:100 dilution), or with goat anti-rat only as a negative control ...
-
bioRxiv - Neuroscience 2023Quote: ... and punches of 0.75 mm diameter were taken from the dorsal dentate gyrus and basolateral amygdala (rat AP coordinates -2.9 to -5.28 relative to Bregma) using a Rapid-Core Sampling Tool (Electron Microscopy Sciences, Hatfield, PA). Punches were separated by hemisphere ...
-
bioRxiv - Microbiology 2023Quote: ... The grids were washed twice with blocking buffer before labeling with secondary antibodies (goat anti-rat or goat anti-rabbit, 10nm, Electron Microscopy Sciences), rinsed three times in 1X PBS ...
-
bioRxiv - Cell Biology 2021Quote: ... glow-discharged grids (15 mA for 15 sec) (Electron Microscopy Sciences, Hatfield, PA). The grids were washed with two 20 μL drops of ultrapure water and then stained with two 20 μL drops of 1% (w/v ...
-
bioRxiv - Developmental Biology 2020Quote: ... sperm suspensions (50 µl) were fixed with paraformaldehyde 4 % (w/v; EMS, Hatfield, MA) in phosphate buffered saline (PBS ...
-
bioRxiv - Physiology 2024Quote: ... The brain was removed from the skull and a ∼6 mm thick section collected from the optic chiasm to the mamillary bodies using a rat coronal brain matrix (Electron Microscopy Sciences, 69083-C). The hypothalamus was isolated by removing brain matter above the top of the third ventricle and lateral to the optic tract ...
-
bioRxiv - Bioengineering 2024Quote: ... glow-discharged with 25 mA for 2 min using an EMS 100X (Electron Microscopy Sciences) glow-discharged unit prior to sample application ...
-
bioRxiv - Immunology 2022Quote: ... grids were glow-discharged with 25 mA for 2 min using an EMS 100X (Electron Microscopy Sciences) glow-discharge unit ...
-
bioRxiv - Immunology 2021Quote: ... grids were glow-discharged with 25 mA for 2 minutes using an EMS 100X (Electron Microscopy Sciences) glow-discharge unit ...
-
bioRxiv - Biophysics 2023Quote: ... that were glow-discharged for 5 s at 40 mA in an EMS100X glow discharge unit (EMS) and then blotted for 0.5-1 s (Blot Force −2 ...
-
bioRxiv - Biochemistry 2020Quote: ... 300 mesh grids were glow discharged for 40 sec at 40 mA with a K100X glow discharger (EMS). For freezing a Vitrobot Mark IV (FEI ThermoFisher ...
-
bioRxiv - Neuroscience 2023Quote: ... The grids were negatively glow discharged (13 mA, 45 sec) using GloQube glow discharge system (Model #025235 EMS). A 10 µl fibril sample at appropriate dilution was applied to the glow discharged grid for 5 minutes with carbon side facing the sample drop ...
-
bioRxiv - Cell Biology 2021Quote: ... an epon resin kit (EMS). Beem capsules (EMS ...
-
bioRxiv - Biochemistry 2021Quote: ... 25 sec in air at 25 mA and 0.4 mbar) GF-1.2/1.3-3Au-45nm-50 grid (Electron Microscopy Sciences) and plunged into liquid ethane after 30 sec incubation and blotting for 3 sec using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biochemistry 2021Quote: ... 30 sec in air at 20 mA and 0.4 mbar) C-flat 1.2/1.3-3Au grids (Electron Microscopy Sciences), and blotted for 4 sec using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2020Quote: ... 400 Cu mesh grids were glow discharged for 30 sec at 25 mA with a K100X glow discharger (EMS), 4 μl of sample was added to the grid left for 1 min ...
-
bioRxiv - Biochemistry 2020Quote: 300-mesh copper grids with a continuous carbon film (EM Resolutions, C300Cu100) were glow-discharged for 30 s at 45 mA with a 100x glow discharger (EMS). 4-µl samples were applied to glow-discharged grids and incubated for 1 minute ...
-
bioRxiv - Biochemistry 2019Quote: ... with a layer of ultra-thin carbon (Agar Scientific) were glow-discharged at 45 mA for 1 min using a K100X Glow Discharge Unit (EMS). A 4 µl-droplet was then applied directly onto the carbon-side of the grid loaded into the humidity chamber of a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Cell Biology 2020Quote: ... 3 μl of diluted sample was deposited onto a glow-discharged (Edwards S150B, 30sec, 30-50 mA, 1,2kV, 10-2 mbar) continuous carbon grid (CF400-CU-UL, Electron Microscopy Sciences). After one minute at RT ...
-
bioRxiv - Biochemistry 2023Quote: ... 2 mM EDTA was applied onto a freshly glow discharged (1 min at 10 mA) CF300-Cu grid (Electron Microscopy Sciences), incubated for 1 min ...
-
bioRxiv - Microbiology 2023Quote: ... 3 μL of purified proteins or immune complexes (∼0.02 mg/mL) were applied onto glow discharged (20 mA for 30s) carbon-coated 400 mesh copper grids (Electron Microscopy Sciences). After 5 s ...
-
bioRxiv - Cell Biology 2020Quote: Immuno-labeled sections on tape were attached to a 10 cm diameter silicon wafer (University Wafer, South Boston, MA) with double-sided carbon adhesive tape (Electron Microscopy Sciences). Wafers were carbon coated (Denton ...
-
Multimodal tubulin binding by the yeast kinesin-8, Kip3, underlies its motility and depolymerizationbioRxiv - Biophysics 2021Quote: C-flat 1.2/1.3-2C holey carbon grids (Protochips) were glow-discharged for 20 s at 20 mA in a table top plasma cleaner (Electron Microscopy Sciences). Taxol-stabilized MTs were diluted to 0.5 mg/mL in cryoEM buffer supplemented with 100 μM Taxol and GMPCPP microtubules were diluted to 0.25 mg/mL in BRB80 buffer ...
-
bioRxiv - Molecular Biology 2019Quote: ... that had been previously plasma treated for 30 seconds using a 15 mA current operating under atmospheric gases using a glow discharger (Electron Microscopy Sciences). Excess sample was blotted away for 4 s using Whatman No ...
-
bioRxiv - Molecular Biology 2021Quote: 4 µL of 0.05 mg/mL SARS-CoV-2 spike protein was applied onto a freshly glow discharged (1 min at 10 mA) CF300-Cu-50 grid (Electron Microscopy Sciences), incubated for 1 min ...
-
bioRxiv - Molecular Biology 2020Quote: ... Grids were glow discharged before for 30 seconds at 25 mA using a GloQube® Plus Glow Discharge System (Electron Microscopy Sciences). The sample was blotted off ...
-
bioRxiv - Microbiology 2020Quote: Carbon-coated copper grids were glow discharged for 30 seconds at 25 mA using a GloQube® Plus Glow Discharge System (Electron Microscopy Sciences). Four microlitres of diluted sample was applied to the grids and incubated for 30 seconds ...
-
bioRxiv - Bioengineering 2022Quote: ... The tethered EVs were fixed in a 2 % glutaraldehyde (MilliporeSigma, Burlington, MA) and 0.1 M sodium cacodylate solution (Electron Microscopy Sciences, Hatfield, PA) for 3 hr ...
-
bioRxiv - Molecular Biology 2023Quote: Carbon-coated copper grids were glow-discharged for 30 s at 25 mA using a GloQube Plus Glow Discharge System (Electron Microscopy Sciences, PA, USA). Grids were applied with 4 μl protein ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... We then mixed the embedding resin following the instructions on our kit (EMbed 812 kit, Electron Microscopy Sciences, Fort Washington, PA, USA) for a hard resin (20ml EMBed-812 ...
-
bioRxiv - Cell Biology 2020Quote: ... infiltrated with Epon resin (Embed-812 kit, EMS 14121), and flat-embedded in the same resin between two pieces of ACLAR embedding film with a 50 μm thickness (EMS 50426 ...
-
bioRxiv - Microbiology 2022Quote: ... with two-part conduction silver epoxy kit (EMS, 12642-14). For imaging ...
-
bioRxiv - Microbiology 2021Quote: ... with two-part conduction silver epoxy kit (EMS, 12642-14). For imaging ...
-
bioRxiv - Cell Biology 2022Quote: ... and Spurr low viscosity embedding kit (Electron Microscopy Sciences, 22050) was used to embed the VOs in resin ...
-
bioRxiv - Cell Biology 2023Quote: EMbed 812 Embedding Kit (Electron Microscopy Science, Cat no. 14121)
-
bioRxiv - Pathology 2019Quote: ... The samples were then sectioned into 5 μm-thick slices and stained with hematoxylin and eosin (H&E; Fisherbrand™ 517-28-2, Waltham, MA) or safranin O and fast green (Saf-O; Electron Microscopy Sciences® 20800, Hatfield, PA), following manufacturer protocols.
-
bioRxiv - Biophysics 2021Quote: Samples described above were diluted in Buffer C and deposited onto freshly glow-discharged (EMS-100 Glow Discharge System, Electron Microscopy Sciences, 30 s at 15 mA) copper Quantifoil (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Pathology 2021Quote: ... Sections were stained with hematoxylin and eosin (H&E; Fisherbrand™ 517-28-2, Waltham, MA) or safranin-O and fast green (Saf-O; Electron Microscopy Sciences® 20800, Hatfield, PA), following manufacturer protocols ...
-
bioRxiv - Neuroscience 2022Quote: ... Silver enhancement (Aurion R-gent Silver enhancer kit, Electron Microscopy Sciences) was performed following the manufacturer’s directions ...
-
bioRxiv - Neuroscience 2023Quote: ... The resin was prepared from the Epon 812 kit (EMS, USA) following the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2022Quote: ... and infiltrated with EPON resin (Electron Microscopy Sciences, EMbed 812 Kit): ascending resin:propylene oxide with pure resin overnight and again the next morning ...
-
bioRxiv - Cancer Biology 2023Quote: ... A Differential Quik III Stain Kit (Electron Microscopy Sciences, Hatfield, PA) was used to stain the cells trapped in the membrane or matrigel ...
-
bioRxiv - Neuroscience 2023Quote: ... samples were embedded with an EMBed-812 embedding kit (EMS, USA) following the manufacturer’s instructions ...
-
bioRxiv - Plant Biology 2024Quote: ... embedded using a Quetol 651 - NSA Kit (no. 14640, Electron Microscopy Sciences), and polymerized at 60°C ...
-
bioRxiv - Bioengineering 2022Quote: ... Then the sample was incubated with cleavage solution (EMS of the MiSeq kit) at 37°C for 3 × 15 min ...
-
bioRxiv - Cell Biology 2022Quote: ... and embedded in epoxy resin (Embed 812 kit for Electron Microscopy, EMS Company) using standard preparative procedure for ultrastructural analyses of tissues and cells ...
-
bioRxiv - Neuroscience 2022Quote: ... and finally embedding using the Technovit 7100 kit (Electron Microscopy Sciences Cat# 14653). Briefly ...
-
bioRxiv - Cancer Biology 2022Quote: ... and embedded in resin mixture of EMbed 812 Kit (Electron Microscopy Sciences cat#: 14120), cured in a 60°C oven ...