Labshake search
Citations for Electron Microscopy Sciences :
2651 - 2700 of 2753 citations for 7H Pyrrolo 2 3 d pyrimidine 7 3 5 bis O 2 4 dichlorophenyl methyl 2 C methyl b D ribofuranosyl 4 chloro since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... rats were deeply anesthetized with sodium pentobarbital (180 mg/kg; Fatal-Plus C IIN, Vortech Pharmaceuticals, Dearborn, MI) and perfused with paraformaldehyde (#15710, Electron Microscopy Sciences (EMS), Hatfield ...
-
bioRxiv - Neuroscience 2021Quote: ... The 40 μm cryosections were cut at -18°C and placed over glass slides treated with tissue capture pen (Electron Microscopy Sciences) and stored at -80°C ...
-
bioRxiv - Neuroscience 2021Quote: ... samples were placed on a Durcupan block with a flat surface and covered with ACLAR® 33 C Film (Electron Microscopy Science). Samples were let polymerize for 72 h at 60 °C.
-
bioRxiv - Cell Biology 2022Quote: ... 3.5 µl of each sample was applied to the plasma-cleaned C-flat grids (Electron Microscopy Sciences, CF-1.2/1.3-4Au-50), pre-blotted and blotted with filter paper (Whatman 1 ...
-
bioRxiv - Biophysics 2022Quote: ... 3.5 μL of purified virions at 1 × 1010 PFU mL-1 was applied to a 400-mesh C-flat holey carbon-coated grid (Electron Microscopy Sciences) at 10 °C with 90% humidity in a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Molecular Biology 2022Quote: ... 1 ug of RNA was denatured at 95°C for 1 minute and subsequently refolded by incubating in 340mM sodium cacodylate buffer (Electron Microscopy Sciences) and 5mM MgCl2 for 20 minutes at 37°C in a thermomixer ...
-
bioRxiv - Neuroscience 2023Quote: ... At −50 °C samples were washed four times in ethanol for 30 minutes each before gradual infiltration with HM20 resin (Electron Microscopy Sciences). Polymerization of the resin was done with a UV light source and was carried out at −50 °C for 48 hours followed by post-polymerization at room temperature for 2 days.
-
bioRxiv - Molecular Biology 2024Quote: ... pH 7.4 buffer for P116 without the N-terminal domain (246–818)) was applied to a 45 s glow- discharged R1.2/1.3 C-flat grid (Electron Microscopy Science, Hatfield, USA), and plunge-frozen in liquid ethane (Vitrobot Mark IV ...
-
bioRxiv - Microbiology 2024Quote: ... Three to four microliters of rsVLP or rsVLP-compound-GSH mixture were applied to either glow-discharged C-flatTM holey carbon copper grids (product No. CF312, Electron Microscopy Sciences) for the PV1-SC6b yeast sample or Lacey carbon copper grids with an ultra-thin carbon support film (product No ...
-
bioRxiv - Cell Biology 2020Quote: ... 5 μl of γ-tubulin mixture was pipetted onto EM grids (Electron Microscopy Sciences, Catalog number: CF400-Cu), which were glow discharged for 25 seconds ...
-
bioRxiv - Plant Biology 2020Quote: ... seedlings were washed twice in MOPS buffer for 5 min and fixed in glutaraldehyde solution (EMS, Hatfield, PA) 2.5% in 100 mM phosphate buffer (pH 7.4 ...
-
bioRxiv - Cancer Biology 2020Quote: ... RT) for 5 min and fixed with PFA (1.6%, Paraformaldehyde 16% solution EM grade, Electron Microscopy Sciences, 15710) before freezing ...
-
bioRxiv - Neuroscience 2020Quote: ... Ribbons of ~5 sections were oriented and collected on formvar/carbon coated nickel slot grids (Electron Microscopy Sciences) using a perfect loop (Electron Microscopy Sciences).
-
bioRxiv - Plant Biology 2022Quote: ... seedlings were washed twice in MOPS buffer for 5 min and fixed in glutaraldehyde solution (EMS, Hatfield, PA) 2.5% in 100 mM phosphate buffer (pH 7.4 ...
-
bioRxiv - Immunology 2024Quote: ... Cells were fixed by adding a warm double strength fixative solution (5% glutaraldehyde (GA, Electron Microscopy Sciences, #16310) and 4% paraformaldehyde (PFA ...
-
bioRxiv - Biophysics 2023Quote: ... 5 μL of protein sample was applied to freshly-ionized carbon-coated copper mesh grids (Electron Microscopy Science). After 15 minutes ...
-
bioRxiv - Microbiology 2023Quote: ... 5 μL of each fixed sample was deposited onto carbon-coated copper grids (Electron Microscopy Sciences, CF400-Cu). Grids were UV-glow discharged immediately prior to sample addition ...
-
bioRxiv - Neuroscience 2020Quote: ... rats were deeply anesthetized with sodium pentobarbital (180 mg/kg; Fatal-Plus C IIN, Vortech Pharmaceuticals, Dearborn, MI) and perfused with paraformaldehyde (#15710, Electron Microscopy Sciences (EMS), Hatfield ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μL of the sample was repeatedly applied and manually blotted three times onto 300 mesh R1.2/R1.3 C-flat Holey carbon grids (Electron Microscopy Sciences, Hatfield, PA, USA) using the multiple blotting technique prior to the Vitrobot step to increase the concentration of pili (34) ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM samples of both EVs and LUVs were prepared on either lacey carbon or C – flat EM grids (Electron Microscopy Sciences, USA), on which 10 nm Protein A colloidal gold particles (Au – NP ...
-
bioRxiv - Neuroscience 2022Quote: ... The 40 μm cryosections were cut at −18°C and placed over glass slides treated with tissue capture pen (Electron Microscopy Sciences 71314) and stored at −80°C ...
-
bioRxiv - Cell Biology 2020Quote: ... The samples were dehydrated in graded acetone series and embedded for 72 hours at 60°C in Embed-812 resin (EMS, Hatfield, PA, USA). Ultrathin sections were collected on copper grids ...
-
bioRxiv - Plant Biology 2022Quote: ... from −30 °C to 0° in 6 h) This was followed by washing in acetone and then infiltration in Spurr resin (EMS, Hatfield, PA, US) at graded concentration and temperature (30% for 10 h from 0 °C to 20°C ...
-
bioRxiv - Neuroscience 2021Quote: ... and washed again twice for 5 minutes each in PBS before coverslipping with Fluoro-Gel (#17985, Electron Microscopy Sciences). Primary antibodies used include ...
-
bioRxiv - Cell Biology 2019Quote: ... homozygous pans1-1 seeds were incubated for 17 h at room temperature in 5 mL of 0.3% (v/v) ethyl methanesulfonate (EMS) (SIGMA ...
-
bioRxiv - Cell Biology 2019Quote: ... and 5 µl of this diluted sample was immediately applied onto glow-discharged grids (Electron Microscopy Sciences, CF400-Cu). The samples were stained with 2% uranyl acetate ...
-
bioRxiv - Biochemistry 2019Quote: 5 µl of TorsinA filaments or TorsinA-liposome mixtures were loaded on glow-discharged (EMS 100, Electron Microscopy Sciences) continuous carbon film grids (CF200-Cu ...
-
bioRxiv - Biochemistry 2019Quote: 5 µl of TorsinA filaments or TorsinA-liposome mixtures were loaded on glow-discharged (EMS 100, Electron Microscopy Sciences) continuous carbon film grids (CF200-Cu ...
-
bioRxiv - Synthetic Biology 2021Quote: ... samples (5 μL) were loaded onto a glow discharged Formvar/carbon-coated copper grid (400 mesh, Electron Microscopy Sciences) and stained with 2% uranyl formate ...
-
bioRxiv - Neuroscience 2019Quote: ... The tissue was immersed for 5 min in reduced osmium solution containing 1% osmium tetroxide (OsO4; Electron Microscopy Sciences) and 1.5% potassium ferrocyanide (Sigma-Aldrich ...
-
bioRxiv - Neuroscience 2023Quote: ... and subsequently mounted on glass slides in Citifluor Mountant Solution (Electron Microscopy Sciences, cat no. AF100-5 & 17977-150). Slides were imaged on a W1-Tokogawa spinning disk confocal microscope using a Nikon 100x ...
-
bioRxiv - Biochemistry 2024Quote: ... 5 μL of sample was applied to a glow discharged QF-R2/1 Cu 200M grid (Electron Microscopy Sciences). Grids were frozen into -185 °C liquid ethane using a Leica EM GP2 automatic plunge freezer equilibrated to 80% humidity and 10 °C with a 10 second sample incubation time and a 2.5 second blot time on Whatman 1 paper ...
-
bioRxiv - Biophysics 2023Quote: ... Grids were picked up from the glass bottom MatTek dish using 5/15 Style Dumont Tweezers (Electron Microscopy Sciences), transferred to their respective tweezers and placed into the EM GP chamber set at 25°C and 99% humidity or the CP3 chamber ...
-
bioRxiv - Bioengineering 2024Quote: ... Micelle solution (5 µM) was added to a carbon support TEM grid (200 mesh, Electron Microscopy Sciences, Hatfield, PA). After 5 minutes of incubation ...
-
bioRxiv - Biophysics 2020Quote: Solutions of extruded vesicles were mixed with 6 nm colloidal gold fiducial markers (Aurion, Wageningen, Netherlands) and applied to glow-discharged C-flat holey carbon grids (Electron Microscopy Science, Hatfield, PA) or QUANTIFOIL R 2/2 holey carbon grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2022Quote: ... for four hours at room temperature (ref: “C. elegans: a practical approach”, chapter “Conventional Genetics” by Jonathan Hodgkin, “Protocol 1-EMS Mutagenesis”, pages 252-253) and selected for increased survival NGM-OP50-1 plates with on 5 mM −7.5 mM DTT ...
-
bioRxiv - Physiology 2024Quote: ... The brain was removed from the skull and a ∼6 mm thick section collected from the optic chiasm to the mamillary bodies using a rat coronal brain matrix (Electron Microscopy Sciences, 69083-C). The hypothalamus was isolated by removing brain matter above the top of the third ventricle and lateral to the optic tract ...
-
bioRxiv - Immunology 2021Quote: For negative staining 5 µl of NLRP3 sample was placed on a copper grid (Electron Microscopy Sciences, cat. no: FCF400CU50), incubated for 1 min ...
-
bioRxiv - Bioengineering 2021Quote: ... An aliquot (5 μl) of each sample was placed onto a CF300-Ni mesh Nickel grid (Electron Microscopy Sciences, EMS). The sample grid was deposited for 1 minute using 2% uranyl acetate solution ...
-
bioRxiv - Bioengineering 2021Quote: ... An aliquot (5 μl) of each sample was placed onto a CF300-Ni mesh Nickel grid (Electron Microscopy Sciences, EMS). The sample grid was deposited for 1 minute using 2% uranyl acetate solution ...
-
bioRxiv - Microbiology 2019Quote: ... The pellet was resuspended in buffer (0.2 M HEPES, pH 7.4, 5 mM CaCl2) and bacteria were fixed by addition of glutaraldehyde (Electron Microscopy Sciences) in buffer to a final concentration of 2.5% for 1 h at 37 °C ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3.5 μl of protein solution were applied onto the glow discharged Quantifoil Cu R1.2/1.3 200 grids (Electron Microscopy Sciences). The grids were blotted for 3s and plunge frozen into liquid ethane using a Vitrobot (Thermo Fisher Scientific) ...
-
bioRxiv - Microbiology 2020Quote: ... The sample was then mounted on a SEM sample holder with double-sided carbon tape and sputter-coated with 5 nm of Pt/Pd (EMS 150 T S Metal Sputter Coater ...
-
bioRxiv - Biophysics 2021Quote: ... after which 5-μL were deposited in a glow-discharged Quantifoil grid (200-mesh copper R2/1, Electron Microscopy Sciences), followed by manual blotting and plunge freezing in a 50/50 ethane propane mix (Airgas ...
-
IL-27R signaling serves as immunological checkpoint for NK cells to promote hepatocellular carcinomabioRxiv - Immunology 2020Quote: For collagen staining deparaffinized and re-hydrated slides were stained for 5 min in Van Gieson solution (EMS, 26374-06) followed by dehydration by 2 changes in 100% ethanol and cleared by 2 changes of xylenes ...
-
bioRxiv - Bioengineering 2024Quote: ... 5 μl of the mixed solution was dropped onto the 200 mesh formvar/carbon copper grid (Electron Microscopy Sciences, USA), allowing it to almost dry for 20 minutes ...
-
bioRxiv - Microbiology 2024Quote: ... A 5 μl aliquot of the sample was deposited onto a 300 mesh copper grid coated with carbon film (EMS). After allowing the sample to interact with the grid for 60 seconds ...
-
bioRxiv - Biochemistry 2023Quote: ... 5 µL of the endosomal suspension was spotted on a mica sheet (Muscovite Mica-V1, Electron Microscopy Sciences, Hatfield, PA) and dried for 15 minutes ...
-
bioRxiv - Biophysics 2023Quote: Four μL of 5 μM GLS2 were applied to plasma-cleaned grids (300 mesh UltraAu Foil R1.2/1.3, Electron Microscopy Sciences, EMS) for a 30-second incubation ...
-
bioRxiv - Cell Biology 2024Quote: ... The stock solution was first diluted in DMSO to make a 5 mM solution and then further diluted in perfusion media (EMS) to give the final concentration of 1 μM for drug treatment and 0.02% DMSO for the vehicle control ...