Labshake search
Citations for Electron Microscopy Sciences :
1901 - 1950 of 2473 citations for 6 Hydroxy 4 trifluoromethyl 2 3' bipyridine 5 carbonitrile since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2023Quote: Part of the sample collected as described above was fixed with 2% paraformaldehyde (EMS grade) and 0.5% glutaraldehyde (EMS grade ...
-
bioRxiv - Cell Biology 2023Quote: ... 8% methanol and 2% water dissolved in glass-distilled acetone (Electron Microscopy Sciences, Hatfield, USA) at –90°C for 64 h and at –45°C for 24 h ...
-
bioRxiv - Biophysics 2023Quote: ... and stained with 2% uranyl acetate and Reynolds lead citrate (Electron Microscopy Sciences, Hartfield, PA). Measurements were performed on the perpendicular cross-sections of 100 hyphae per culture condition using a JEOL JEM-1400 electron microscope (Peabody ...
-
bioRxiv - Cell Biology 2023Quote: ... Post-fixation was performed using 2% (w/v) osmium tetroxide (Electron Microscopy Sciences, Hatfield, UAS) for 30 min in chilled cacodylate buffer ...
-
bioRxiv - Biophysics 2024Quote: ... samples were thawed and inactivated for 2 hours at room temperature by adding PFA (EMS) to a final concentration of 4 % (v/v) ...
-
bioRxiv - Bioengineering 2024Quote: ... glow-discharged with 25 mA for 2 min using an EMS 100X (Electron Microscopy Sciences) glow-discharged unit prior to sample application ...
-
bioRxiv - Cell Biology 2020Quote: ... the samples were dehydrated through a series of increasing concentration of ethanol (30%, 50%, 70%, 90%, 3 times 100% anhydrous) and embedded in EMBed 812 epoxy resin (EMS, Hatfield, PA). After resin polymerization ...
-
bioRxiv - Bioengineering 2020Quote: ... were prepared by applying 3 µL of 10 mg/mL sample on pretreated lacey carbon 400 mesh TEM grids (Electron Microscopy Sciences). Following a 3 s blot ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 µl of freshly purified full-length S protein was adsorbed to a glow-discharged carbon-coated copper grid (Electron Microscopy Sciences), washed with deionized water ...
-
bioRxiv - Biochemistry 2020Quote: Freshly prepared filament samples (3 μL) were applied to glow-discharged Lacey carbon film grids (LC200-Cu; Electron Microscopy Sciences, Hatfield PA). The grid was blotted for 2.0 s using Whatman #1 filter paper (GE Healthcare ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 µl of freshly purified full-length S protein was adsorbed to a glow-discharged carbon-coated copper grid (Electron Microscopy Sciences), washed with deionized water ...
-
bioRxiv - Biophysics 2020Quote: ... the head was placed onto the scanner directly after cleaving the glued-on 3 mm Muscovite Mica disk (Electron Microscopy Sciences, Hatfield). The concentrated sample was diluted in imaging buffer to 60 µg/mL ...
-
bioRxiv - Immunology 2022Quote: ... and 3 µL of the complex/detergent mixture was immediately applied to QuantiFoil 300 mesh 1.2/1.3 grids (Electron Microscopy Sciences, Hatfield, PA) that had been freshly glow discharged with PELCO easiGLOW (Ted Pella ...
-
bioRxiv - Neuroscience 2023Quote: ... The tissue was rinsed five times for 3 min in DDH2O and then dehydrated through graded alcohols into acetone and flat-embedded in Durcopan resin (Electron Microscopy Sciences) between mylar strips and placed in a 60°C oven for 48h.
-
bioRxiv - Biophysics 2023Quote: ... and cryo-ET grids were prepared by applying 3 μL of sample to glow-discharged (30 s) Lacey carbon grids (Electron Microscopy Sciences). Grids were blotted on both sides for 6 s with 0 blotting force and vitrified immediately by plunge freezing into liquid nitrogen-cooled liquid ethane with an FEI Mark IV Vitrobot cryo-sample plunger ...
-
bioRxiv - Genomics 2023Quote: ... the cells were washed five times with PBS-T and post-fixed with 3% paraformaldehyde and 0.1% glutaraldehyde (Electron Microscopy Sciences #16120) in 1X PBS for 30 minutes at room temperature ...
-
bioRxiv - Molecular Biology 2023Quote: Primed and naïve hESCs were prepared as described in the above section and fixed for 10 min in a 3% paraformaldehyde solution (Electron Microscopy Science). Cells were then permeabilized for 7 min with ice-cold PBS supplemented with 0.5% Triton X-100 (Sigma-Aldrich) ...
-
bioRxiv - Microbiology 2023Quote: ... The buffer was removed and samples stained with post-fixative for 3 hours (Osmium tetroxide, Ted Pella; Tannic Acid, Electron Microscopy Sciences). After washing with distilled water ...
-
bioRxiv - Microbiology 2023Quote: Negatively stained samples were made by standard methods: 3 µl of sample was placed on a glow-discharged grid with ultrathin carbon layered on lacey carbon (Electron Microscopy Sciences), washed with three drops of water and stained with 1% uranyl acetate ...
-
bioRxiv - Biochemistry 2023Quote: 3 μg of purified NHE9*CC sample was applied to freshly glow-discharged Quantifoil R2/1 Cu300 mesh grids (Electron Microscopy Sciences) and blotted for 3.0s with a 20s waiting time prior ...
-
bioRxiv - Cell Biology 2023Quote: ... Samples were gradually dehydrated in an ethanol series (50%,75%,95%, 3×100%) and then embedded in EMbed-812 epoxy resin (Electron Microscopy Sciences), followed by polymerization for 48h at 60°C.Thin sections (70nm ...
-
bioRxiv - Cell Biology 2020Quote: ... 5 μl of γ-tubulin mixture was pipetted onto EM grids (Electron Microscopy Sciences, Catalog number: CF400-Cu), which were glow discharged for 25 seconds ...
-
bioRxiv - Plant Biology 2020Quote: ... seedlings were washed twice in MOPS buffer for 5 min and fixed in glutaraldehyde solution (EMS, Hatfield, PA) 2.5% in 100 mM phosphate buffer (pH 7.4 ...
-
bioRxiv - Cancer Biology 2020Quote: ... RT) for 5 min and fixed with PFA (1.6%, Paraformaldehyde 16% solution EM grade, Electron Microscopy Sciences, 15710) before freezing ...
-
bioRxiv - Neuroscience 2020Quote: ... Ribbons of ~5 sections were oriented and collected on formvar/carbon coated nickel slot grids (Electron Microscopy Sciences) using a perfect loop (Electron Microscopy Sciences).
-
bioRxiv - Plant Biology 2022Quote: ... seedlings were washed twice in MOPS buffer for 5 min and fixed in glutaraldehyde solution (EMS, Hatfield, PA) 2.5% in 100 mM phosphate buffer (pH 7.4 ...
-
bioRxiv - Biophysics 2023Quote: ... 5 μL of protein sample was applied to freshly-ionized carbon-coated copper mesh grids (Electron Microscopy Science). After 15 minutes ...
-
bioRxiv - Microbiology 2023Quote: ... 5 μL of each fixed sample was deposited onto carbon-coated copper grids (Electron Microscopy Sciences, CF400-Cu). Grids were UV-glow discharged immediately prior to sample addition ...
-
bioRxiv - Immunology 2024Quote: ... Cells were fixed by adding a warm double strength fixative solution (5% glutaraldehyde (GA, Electron Microscopy Sciences, #16310) and 4% paraformaldehyde (PFA ...
-
bioRxiv - Cell Biology 2020Quote: Ovaries were dissected in IMADS (Singleton and Woodruff 1994) or 1X PBS and fixed with 4% PFA (Electron Microscopy Sciences) in 1X PBS plus 0.3% Triton-X 100 ...
-
bioRxiv - Cell Biology 2022Quote: ... trypsinized cells in FACS buffer (PBS with 1% BSA) were fixed using 4% paraformaldehyde (cat no. 15710; Electron Microscopy Sciences) for 20 min at room temperature ...
-
bioRxiv - Cell Biology 2022Quote: ... samples were washed once in wash buffer and fixed with a 4% Paraformaldehyde + 0.1% Glutaraldehyde (Electron Microscopy Sciences, Hatfield, PA) solution made in PBS ...
-
bioRxiv - Molecular Biology 2020Quote: ... The grid was quickly washed using a 4-μL drop of milli-Q (MilliporeSigma) water and stained with 4 μL of negative stain solution composed of either 1% (w/v) uranyl acetate (EMS) with 0.5% (w/v ...
-
bioRxiv - Neuroscience 2019Quote: ... Dissected larvae were fixed for 20 (VNC) or 45 minutes (NMJs) in 4% formaldehyde solution (Electron Microscopy Sciences, Hatfield, PA) in phosphate-buffered saline (PBS) ...
-
bioRxiv - Neuroscience 2019Quote: ... When animals reached the indicated age they were anaesthetized with isoflurane and intracardiac perfusion with 4% paraformaldehyde (Electron Microscopy Sciences) in PBS was performed ...
-
bioRxiv - Immunology 2019Quote: ... The right-side half brains were harvested and fixed in 4% paraformaldehyde (made in PBS; #15710, Electron Microscopy Sciences, USA) at 4◻ for 6 days ...
-
bioRxiv - Biochemistry 2020Quote: ... Cell were then fixed for 10 minutes at room temperature in PBSM + 4% paraformaldehyde (Electron Microscopy Sciences 50-980-492). Following fixation ...
-
bioRxiv - Neuroscience 2021Quote: ... Canada) diluted in water combined (1:1) with 4% aqueous osmium tetroxide (cat#19170, Electron Microscopy Sciences, Hatfield, PA, USA) for 1 hr ...
-
bioRxiv - Neuroscience 2020Quote: ... perfused intracardially with ice-cold phosphate-buffered saline (PBS) and fixed with 4 % paraformaldehyde (PFA, 19210, Electron Microscopy Sciences, USA) in phosphate buffer (PB) ...
-
bioRxiv - Neuroscience 2020Quote: Adult mice were anesthetized with isoflurane and transcardial perfusion was performed with 7.5 ml of 1x PBS following by 7.5 ml of ice cold 4% PFA in 1x PBS (EMS – 15710-S). Brains were then dissected out and post-fixed in 4% PFA in 1x PBS for 2 hours at 4°C ...
-
bioRxiv - Microbiology 2020Quote: ... Post infection coverslips were rinsed in PBS then fixed for 10 minutes in 4% Paraformaldehyde in PBS (Electron Microscopy Sciences) for 10 min ...
-
bioRxiv - Cell Biology 2022Quote: ... and lens were gently removed and the resulting posterior eyecup was fixed in freshly prepared ice-cold 4% (w/v) PFA (171010, EMS) in PBS for 30 min ...
-
bioRxiv - Neuroscience 2022Quote: ... mice were perfused transcardially with heparinized saline (10 units/ml of heparin) and 4% paraformaldehyde (PFA) that was prepared from 32% PFA Aqueous Solution (Cat# 15714, EMS), using a peristaltic pump at a rate of 7 mL/min ...
-
bioRxiv - Biochemistry 2022Quote: ... followed by application of 4 μl of the mix onto glow discharged continuous carbon electron microscopy grid (400 mesh, EMS) and was incubated on grid for 1 min ...
-
bioRxiv - Biochemistry 2022Quote: ... and then 4 μl of the mixture was added to a Quantifoil R1.2/1.3 Au 300 mesh grid (Electron Microscopy Sciences) that had been glow discharged for 60 seconds at 20 mA using a Pelco easiGlow ...
-
bioRxiv - Bioengineering 2022Quote: ... the media is removed from the wells and the cells are fixated via a 4% paraformaldehyde (PFA, Electron Microscopy Sciences) solution incubation for 10 minutes ...
-
bioRxiv - Neuroscience 2021Quote: Adult animals were perfused with 4% paraformaldehyde (PFA) in 1× phosphate-buffered saline (PBS) (15710-Electron Microscopy Sciences, Hatfield, PA), brains ...
-
bioRxiv - Immunology 2021Quote: ... to a final concentration of 0.005 mM and 4 μL of this solution was applied to plasma-cleaned 1.2/1.3 C-Flat holey carbon grids (Electron Microscopy Sciences) using a Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Bioengineering 2020Quote: ... Fixation buffer consisting of 4% paraformaldehyde (Alfa Aeser, USA, CAT#:43368) and 0.1% glutaraldehyde (Electron Microscopy Sciences, USA, CAT#: 16100) was used to fix cells on the coated surfaces.
-
bioRxiv - Neuroscience 2022Quote: ... the recipient mice eyes and cultured retinal organoids were fixed with 4% paraformaldehyde (PFA) (Electron Microscopy Sciences, Hatfield, PA, USA) in PBS and dehydrated in a sucrose gradient (10% ...