Labshake search
Citations for Electron Microscopy Sciences :
101 - 150 of 747 citations for N6 2 aminoethyl 9H purine 2 6 diamine since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2023Quote: ... Quantifoil 200 mesh holey carbon R2/2 (EMS) were glow-discharged for 60s or 90s at 20mA or 15mA using a PELCO easiGlow glow discharge system (Ted Pella) ...
-
bioRxiv - Pathology 2024Quote: ... 4% PFA was supplemented with 2% glutaraldehyde (EMS). For biochemical analyses such as immunoblotting ...
-
bioRxiv - Microbiology 2024Quote: ... and stained with 2% uranyl acetate (EMS # 22400) and lead citrate (VWR #1.07398) ...
-
bioRxiv - Neuroscience 2024Quote: ... by immersion in 2% paraformaldehyde (15710-S, EMS) 1% glutaraldehyde (G7526 ...
-
bioRxiv - Neuroscience 2024Quote: ... with 2% sodium borate (21130, Electron Microscopy Sciences). 60 nm sections were mounted on copper grids (FCF100-Cu-50 ...
-
bioRxiv - Cell Biology 2020Quote: Cells were cultured on cell tight C-2 cell disks (Sumitomo Bakelite) and fixed for 2 h in 2.5% glutaraldehyde (Electron Microscopy Science) in 0.1 M phosphate buffer (pH 7.4 ...
-
bioRxiv - Neuroscience 2021Quote: ... first with PBS (< 2 min), then with fixative (4% paraformaldehyde w/v, Sigma; 0.1-2 glutaraldehyde, v/v, Electron Microscopy Sciences (EMS) or TAAB Laboratories Equipment Ltd. ...
-
bioRxiv - Biochemistry 2021Quote: ... in the presence of 1 mM ATPγS for 5 min prior to Vitrobot freezing on 300 mesh R 2/2 Quantifoil copper grids (Electron Microscopy Sciences). All three datasets were collected on a FEI Titan Krios TEM with a GATAN post column energy filter (20 eV zero-loss filtering ...
-
bioRxiv - Cell Biology 2021Quote: ... cells were plated at 30,000 cells/cm2 on 200 mesh gold R 2/2 carbon Quantifoil EM grids (Electron Microscopy Sciences).
-
bioRxiv - Microbiology 2023Quote: ... 3 μL of concentrated pseudovirus sample was applied to a carbon-coated grid (2/2-4C C-flats; Electron Microscopy Sciences), blotted with filter paper ...
-
bioRxiv - Cell Biology 2020Quote: ... Samples were then washed with 2 drops of water and stained with 2 successive drops of 0.7% (w/v) uranyl formate (EMS, Hatfield, PA, USA) followed by blotting until dry ...
-
bioRxiv - Microbiology 2021Quote: ... Cells were rinsed 5× 2 minutes each in chilled distilled water and then placed in chilled 2% (w/v) uranyl acetate in ddH2O (Electron Microscopy Sciences) overnight ...
-
bioRxiv - Biophysics 2022Quote: ... Samples were then washed with 2 drops of water and stained with 2 successive drops of 0.7% (w/v) uranyl formate (EMS, Hatfield, PA, USA) followed by blotting until dry ...
-
bioRxiv - Biochemistry 2021Quote: ... Samples of the complex (2 μL) were applied to glow-discharged (1 min, easiGlow, Pelco) R2/2 300-mesh Quantifoil holey carbon grids (Electron Microscopy Sciences). The grids were blotted for 2 s with Whatman 41 filter paper and flash-frozen by plunging into liquid ethane using a Leica EM CPC manual plunger ...
-
bioRxiv - Biochemistry 2024Quote: ... Samples were frozen using a FEI Vitrobot Mark IV cooled to 8 ºC at 100% humidity on 2/2 200 mesh UltrAuFoil gold grids (Electron Microscopy Sciences) glow discharged at 15 mA for 25 s (PELCO easyGLOW) ...
-
bioRxiv - Immunology 2023Quote: ... A 3-µl drop of the mixture was applied to a plasma-cleaned C-flat 2/2 holey carbon grid (Electron Microscopy Sciences), manually blotted and vitrified in liquid ethane with a homemade plunger.
-
bioRxiv - Biophysics 2024Quote: ... 3 μL of chromosome solution was applied onto Quantifoil 200 mesh gold or copper R 2/2 extra thick carbon London Finder EM grids (Electron Microscopy Sciences). Excess liquid was blotted from the back (non-sample ...
-
bioRxiv - Biophysics 2024Quote: ... a 4 μL aliquot was applied to a Quantifoil 2/2 carbon-coated 200 mesh copper grid (Electron Microscopy Sciences, Hatfield, PA) that was glow-discharged for 30 sec at 20 mA in a Pelco Easi-Glow discharge device (Ted Pella ...
-
bioRxiv - Biophysics 2022Quote: ... Cells were fixed with 2% paraformaldehyde (Electron Microscopy Sciences) and 2.5% glutaraldehyde (Electron Microscopy Sciences ...
-
bioRxiv - Immunology 2022Quote: ... Quantifoil R 2/1 holey carbon copper grid (EMS) were used for sample vitrification ...
-
bioRxiv - Plant Biology 2022Quote: The Arabidopsis thaliana atg2-2 mutant allele (EMS, Gln803stop) was reported by18 ...
-
bioRxiv - Cell Biology 2022Quote: ... After staining in 2% uranyl acetate solution (EMS #22400) for at least 1.5h and dehydration in an ascending series of ethanol solutions ...
-
bioRxiv - Microbiology 2021Quote: Samples were fixed with 2% glutaraldehyde (Electron Microscopy Sciences) and 4% paraformaldehyde ...
-
bioRxiv - Microbiology 2021Quote: Samples were fixed in 2% (v/v) glutaraldehyde (EMS) + 0.5% (v/v ...
-
bioRxiv - Cell Biology 2020Quote: ... cells were fixed with 2% paraformaldehyde (PFA) (EMS 15714) in PBS(+/+ ...
-
bioRxiv - Neuroscience 2020Quote: ... ON were stained with 2% osmium (Electron Microscopy Sciences), rinsed in sodium cacodylate ...
-
bioRxiv - Immunology 2020Quote: ... fixed in 2% paraformaldehyde (Electron Microscopy Sciences, Hatfield, PA), then permeabilized and stained intracellularly for granzyme B in 2.4G2 supernatant containing 10% normal mouse serum and 0.5% saponin (Sigma) ...
-
bioRxiv - Genetics 2022Quote: ... 2% formaldehyde (#15710, Electron Microscopy Sciences, Hatfield, PA, USA) and 0.1% glutaraldehyde (#16220 ...
-
bioRxiv - Neuroscience 2023Quote: ... tissues were incubated in 2% uranyl acetate (EMS, USA) at overnight and lead aspartate solution at for 30 minutes to enhance membrane contrast ...
-
bioRxiv - Physiology 2023Quote: ... for 2□min and 3% lead citrate (EMS, 22410) for 1□min ...
-
bioRxiv - Microbiology 2022Quote: ... cells were fixed with 2% glutaraldehyde (Electron Microscopy Sciences) in HEPES buffer (pH 7.4 ...
-
bioRxiv - Plant Biology 2024Quote: ... Samples were post-fixed in 2% osmium tetroxide (EMS) and potassium ferrocyanide (Mallinkckrodt Baker Inc ...
-
bioRxiv - Neuroscience 2023Quote: ... for 2 min and 3% lead citrate (EMS, #22410) for 1 min ...
-
bioRxiv - Neuroscience 2023Quote: ... The grids were stained with 2% uranyl acetate (EMS).
-
bioRxiv - Neuroscience 2022Quote: ... and fixed in 2% paraformaldehyde (PFA, Electron Microscopy Sciences) in 1xPBS for 55 minutes at room temperature ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μL of 2% uranyl formate (Electron Microscopy Sciences) was deposited on the grid for 90 s then blotted off ...
-
bioRxiv - Immunology 2024Quote: ... cells were fixed in 2% PFA (Electron Microscopy Sciences) during 20’ at room temperature ...
-
bioRxiv - Cell Biology 2024Quote: ... Quantifoil R2/2 grids (Electron Microscopy Sciences, #Q225CR-06) were treated using 1 mL of chloroform overnight followed by negative glow discharge (30 seconds at 25 mAh) ...
-
bioRxiv - Microbiology 2024Quote: ... and fixed for 10 min in 2% paraformaldehyde (EMS). Permeabilization was carried out with 0.5% Triton X-100 and labelling with either 1/200 VE-cadherin conjugated Alexa Fluor 647 (A22287 ...
-
bioRxiv - Neuroscience 2024Quote: ... and fixed in 2% paraformaldehyde (PFA) in PBS (EMS) for 10-15 min ...
-
bioRxiv - Neuroscience 2024Quote: ... 100 mL fixative solution (2% glutaraldehyde (EMS cat. #16320) + 4% paraformaldehyde (EMS cat ...
-
bioRxiv - Neuroscience 2021Quote: Coronal sections (n=2 mice, P30) and whole mounts (n=2 mice, P28) were incubated with Immunosaver (1:200; EMS, Fort Washington, PA) for 20 min at 60°C ...
-
bioRxiv - Biochemistry 2022Quote: ... sarkosyl and 4 μl of the suspension was applied directly to a glow-discharged C-flat™ Holey Carbon CF-2/2-4C Cu 400 mesh cryo-EM grid (Electron Microscopy Sciences) or Quantifoil R2/2 Cu 300 mesh grids in the chamber of the Leica GP2 plunging robot ...
-
bioRxiv - Biochemistry 2021Quote: ... sarkosyl and 4 μl of the suspension was applied directly to a glow-discharged C-flat™ Holey Carbon CF-2/2-4C Cu 400 mesh cryo-EM grid (Electron Microscopy Sciences) in the chamber of the Leica GP2 plunging robot ...
-
bioRxiv - Biophysics 2024Quote: Cryo-EM samples of concentrated peptide solutions were prepared on either 300 mesh 2/2 Quantifoil or C-flat EM grids (Electron Microscopy Sciences, USA), on which 10 nm protein A-conjugated colloidal gold particles (Au–NP ...
-
bioRxiv - Neuroscience 2024Quote: ... samples were incubated in a 2% OsO4 in 0.15 M cacodylate buffer solution containing 2 mM calcium chloride (19152, Electron Microscopy Sciences, Hatfield, PA, USA) for 2 hours in the dark ...
-
bioRxiv - Cell Biology 2020Quote: ... 5A were fixed with warm 2% PFA (Electron Microscopy Sciences) in PBS containing 0.4% w/v Sucrose for 12 minutes at room temperature and quenched with 0.25% Ammonium Chloride (SIGMA ...
-
bioRxiv - Neuroscience 2021Quote: ... Slices were stained in 2% osmium tetroxide (Electron Microscopy Sciences) in cacodylate buffer for 1 h at room temperature ...
-
bioRxiv - Microbiology 2021Quote: ... the cells were fixed in 2% glutaraldehyde (Electron Microscopy Sciences) in 100 mM sodium cacodylate with 2 mM CaCl2 ...
-
bioRxiv - Neuroscience 2020Quote: ... a pre-warmed 2% (w/v) glutaraldehyde (Electron Microscopy Sciences) in 0.1 M sodium cacodylate buffer ...