Labshake search
Citations for Electron Microscopy Sciences :
701 - 750 of 806 citations for Oligodendrocyte transcription factor 1 OLIG1 Antibody since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2024Quote: ... and placed on a slot (1 × 2 mm) EM copper grids covered with a formvar film (Electron Microscopy Sciences, FF2010-Cu). Grids were placed (section face-down ...
-
bioRxiv - Bioengineering 2024Quote: A 20 µL droplet of 10 nM origami solution diluted in 1×TAE buffer sup- plemented with 12.5 mM MgCl2 was deposited onto a freshly cleaved mica substrate (Electron Microscopy Sciences). The sample was incubated for 1 minute ...
-
bioRxiv - Microbiology 2024Quote: 3 µl of sheath preparation sample was incubated for 1 min on glow-discharged carbon-coated formvar grids (Electron Microscopy Sciences). To stain the sample ...
-
β-1,6-glucan plays a central role in the structure and remodeling of the bilaminate fungal cell wallbioRxiv - Microbiology 2024Quote: ... 1 mL of culture was fixed at ambient temperature in the dark (1-2 h) with paraformaldehyde 3.8% (PFA, Electron Microscopy Sciences). Cells were then centrifuged 3 min at 8000 g and washed 3 times with 500 µL PBS ...
-
Superresolution microscopy reveals photoreceptor-specific subciliary location and function of Cep290bioRxiv - Cell Biology 2020Quote: Eye cups from mice aged 4-8 months (Figures 2–5) or 10 days postnatal (Figures 6, 7, 9) were fixed for five minutes in 1% PFA (Electron Microscopy Science) diluted in 1x PBS ...
-
bioRxiv - Cell Biology 2020Quote: 4 μL of the GUV COPII BR was applied to negatively glow-discharged C-flat holey carbon coated gold grids (CF-4/1-4AU, Electron Microscopy Sciences), blotted from both sides (60 seconds pre-blot wait ...
-
bioRxiv - Microbiology 2022Quote: ... grids were washed by contact with 2 drops of milliQ water and were negatively stained with 20 µl of 1% uranyl acetate (Electron Microscopy Sciences) for 1 min ...
-
bioRxiv - Cell Biology 2019Quote: ... resuspended in 1 ml fixative (40 mM KHPO4 pH 7.0 containing 1% EM grade glutaraldehyde and 0.2% EM grade formaldehyde from Electron Microscopy Sciences (EMS, Munich, Germany) and incubated for 3 min.
-
bioRxiv - Neuroscience 2020Quote: ... Shi/Shi:Rag2-/- mice grafted with control and RRMS hiOLs (n=4 per group) were perfused with 1% PBS followed by a mixture of 4% paraformaldehyde/5% glutaraldehyde (Electron Microscopy Science) in 1% PBS ...
-
bioRxiv - Biochemistry 2021Quote: ... The samples were diluted to ~20 μg mL−1 and applied for 60 s to glow discharged Cu grids with continuous carbon film (300 mesh) (Electron Microscopy Sciences). Excess sample was blotted using a Whatman filter paper and stained for an additional 60 s using Nano-W (Nanoprobes) ...
-
bioRxiv - Microbiology 2019Quote: ... The agarose block containing the bacteria was cut into small cubes (max. 1 mm3) and cubes were post-fixed was performed with 2% osmium tetroxide (Electron Microscopy Sciences) in buffer containing 1.5% potassium ferricyanide (Sigma ...
-
bioRxiv - Biophysics 2021Quote: ... 2uL of dialyzed sample was then applied to glow-discharged (1 min, easiGlow, Pelco) R2/2 200- or 300-mesh Quantifoil holey carbon grids (Electron Microscopy Sciences). The grids were subsequently blotted for 2 or 3 seconds ...
-
bioRxiv - Cell Biology 2021Quote: ... The grids were washed with two 20 μL drops of ultrapure water and then stained with two 20 μL drops of 1% (w/v) uranyl acetate (Electron Microscopy Sciences); the first for 10 sec and the second for 1 min ...
-
bioRxiv - Cell Biology 2022Quote: ... the flow chamber was washed with a second reaction mix containing 25 µM tubulin before fixing with 1% glutaraldehyde (Electron Microscopy Sciences) for 5 minutes at room temperature ...
-
bioRxiv - Microbiology 2020Quote: ... and placed on a slot (1 × 2 mm) EM copper grid covered with a formvar film (FF2010-Cu, Electron Microscopy Sciences, USA). Sections were covered by 0.1 μm TetraSpeck microsphere fiducials (Thermo Fisher Scientific) ...
-
bioRxiv - Bioengineering 2022Quote: ... 4 mm diameter PDMS wells were passively adhered to #1 9 mm x 9 mm glass coverslips (Electron Microscopy Sciences #72190-09). Wells were passivated overnight using vapor deposition of Trichloro(1H,1H,2H,2H-perfluorooctyl)silane (Sigma 448931 ...
-
bioRxiv - Cell Biology 2019Quote: For negative staining 3 µl of purified 40S+60S ribosome fractions or alternatively 3 µl of 40S+60S ribosome fractions in the presence of (PR)20 (1:10 molar ratio) were deposited onto freshly glow-discharged carbon-coated 400 mesh copper electron microscopy (EM) grids (Electron Microscopy Sciences) and retained on the grid for 1 min ...
-
bioRxiv - Neuroscience 2019Quote: ... and then immersed in 50% ethanol before being dehydrated in ascending concentrations of ethanol (50%, 70%, 90%, 100%) containing 1% uranyl acetate (UA; Electron Microscopy Sciences) with application of microwave irradiation (250 W ...
-
bioRxiv - Developmental Biology 2021Quote: ... Tissue was lysed until no visible pieces remained just prior to use in 15 μL of lysis buffer (50 mM Tris pH 8.0, 150 mM NaCl, 1% Triton X-100) with a pestle (Electron Microscopy Sciences, 64788) and a LabGen 7B homogenizer (ColePalmer ...
-
bioRxiv - Physiology 2021Quote: ... Cells were then incubated with the DNA intercalator Iridium (Fluidigm, 201192A) at a dilution of 1:4,000 in 2% paraformaldehyde (Electron Microscopy Sciences, 15714) in DPBS (Corning ...
-
bioRxiv - Biochemistry 2021Quote: ... Samples of the complex (2 μL) were applied to glow-discharged (1 min, easiGlow, Pelco) R2/2 300-mesh Quantifoil holey carbon grids (Electron Microscopy Sciences). The grids were blotted for 2 s with Whatman 41 filter paper and flash-frozen by plunging into liquid ethane using a Leica EM CPC manual plunger ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 1/4 300 mesh Cu, Electron Microscopy Sciences) followed by plunging into liquid ethane using an FEI Vitrobot Mark IV set to a blot time of 22 and a blot force of 22 for QYNNENNFV and 24 for GSTVYAPFT ...
-
bioRxiv - Biochemistry 2021Quote: ... 1.8 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 2/1 200 mesh Cu, Electron Microscopy Sciences) and plunge frozen into liquid ethane using a FEI Vitrobot Mark IV using a blot time of 25-30 seconds and a blot force of 22 ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 2/1 200 mesh Cu, Electron Microscopy Sciences) and plunge frozen into liquid ethane using a FEI Vitrobot Mark IV ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 μl of SKD3 with 1 mM ATP was applied to glow-discharged 400 mesh formvar carbon film grids with copper supports (Electron Microscopy Sciences, EMS) and stained with a 5 mg/ml uranyl formate solution ...
-
bioRxiv - Pathology 2021Quote: ... slides were washed twice with 1 mL of PBS wash buffer and fixed in a solution of 2% glutaraldehyde (Electron Microscopy Sciences) solution in low-barium PBS for 5 minutes ...
-
bioRxiv - Molecular Biology 2021Quote: 4 µL of 0.05 mg/mL SARS-CoV-2 spike protein was applied onto a freshly glow discharged (1 min at 10 mA) CF300-Cu-50 grid (Electron Microscopy Sciences), incubated for 1 min ...
-
bioRxiv - Microbiology 2021Quote: 8 μl of 1 x 1010 pfu/mL of phages was applied to a copper mesh grid coated with formvar and carbon (Electron Microscopy Sciences) for 2 minutes and then gently blotted off with a piece of Whatman filter paper ...
-
bioRxiv - Neuroscience 2021Quote: ... was applied to glow-discharged Quantifoil holey carbon grids (Gold R2/1; 200 mesh) overlaid with an additional 2-nm carbon layer (Electron Microscopy Sciences). The grids were blotted for 3-5 s and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Genomics 2021Quote: ... Cells were then incubated with the DNA intercalator Iridium (Fluidigm, 201192A) at a dilution of 1:4,000 in 2% paraformaldehyde (Electron Microscopy Sciences, 15714) in DPBS (Corning ...
-
bioRxiv - Biochemistry 2022Quote: ... a 3-μl aliquot of the protein sample was applied to a glow-discharged Quantifoil holey carbon grid (Au 300 2/1 mesh) (Electron Microscopy Sciences), blotted for 2 s ...
-
bioRxiv - Biochemistry 2022Quote: Washed and deglycosylated RBCs were diluted 1:100 and added to carbon coated 400 mesh copper grids (CF400-CU, Electron Microscopy Sciences) that had been glow discharged and pre- coated in poly-d-lysine solution ...
-
bioRxiv - Neuroscience 2023Quote: ... Coverslips were then counterstained with Hoechst 33342 (1:10,000) and mounted using Fluoro-gel in TES Buffer (Electron Microscopy Sciences, 17985-30). The slides were imaged using a Zeiss Observer D1 microscope with a 40x objective.
-
bioRxiv - Physiology 2022Quote: ... freshly isolated pituitary glands were fixed with 2.5% formaldehyde/glutaraldehyde in 0.1 M Sodium Cacodylate Buffer (pH 7.4, Emsdiasum) and 1% OsO4 (Electron Microscopy Science, Cat No. 15949), followed by dehydration and staining with uranyl acetate/lead citrate ...
-
bioRxiv - Molecular Biology 2022Quote: ... 1 ug of RNA was denatured at 95°C for 1 minute and subsequently refolded by incubating in 340mM sodium cacodylate buffer (Electron Microscopy Sciences) and 5mM MgCl2 for 20 minutes at 37°C in a thermomixer ...
-
bioRxiv - Neuroscience 2024Quote: ... iPS cell-derived neuronal cultures were fixed using 4% paraformaldehyde diluted in 1 PBS from a 16% aqueous solution (Electron Microscopy Sciences) for 20 min and then permeabilized with 0.2% Triton X-100 (Sigma) ...
-
bioRxiv - Biochemistry 2023Quote: ... In-house graphene grids were prepared from Trivial Transfer Graphene sheets (ACS Material) and QUANTIFOIL R2/1 mesh 300 gold (Electron Microscopy Sciences) by following a protocol introduced by Ahn et. ...
-
bioRxiv - Cancer Biology 2024Quote: ... then resuspended in 60 µl PBS with 1% BSA and 5 µl of cells was added to each well of a multi-well microscope slide (Electron Microscopy Sciences) pre-coated with 0.1% poly-L-lysine (Sigma Aldrich) ...
-
bioRxiv - Biophysics 2024Quote: ... These cells in the log-growth phase were collected and deposited on glow-discharged Quantifoil grids (R 2/1, Cu 200-mesh grid, Electron Microscopy Sciences), as described previously (5) ...
-
bioRxiv - Cell Biology 2024Quote: ... were immersed in and fixed by 4 % glutaraldehyde (48 h/4 °C), post-fixed by 1% osmium tetroxide (2 h, RT) and were embedded into Epon resin (Electron Microscopy Sciences) as described previously32 ...
-
bioRxiv - Cell Biology 2024Quote: ... cells were first fixed with 1 mL of the fixative (2% paraformaldehyde [Electron Microscopy Sciences] dissolved in 250 mM HEPES [pH 7.4]) for 10 min at room temperature (approximately 25°C) ...
-
bioRxiv - Microbiology 2023Quote: ... Sample aliquots (40 µl) were taken at regular time points over 40 h and fixed with 10 µl of 1% glutaraldehyde each (Electron Microscopy Sciences). The number of food vacuoles in 10 cells was counted under light microscopy ...
-
bioRxiv - Neuroscience 2022Quote: ... Grids were washed with two drops of double-distilled H2O and stained with two drops of freshly prepared 1% (w/v) uranyl formate (Electron Microscopy Sciences). The samples were analysed at room temperature using a Tecnai Spirit (FEI ...
-
bioRxiv - Microbiology 2022Quote: ... Washed tardigrades were dried onto one field of a 76 × 26 × 1 mm 10-well (6mm) polytetrafluoroethylene-printed slide (Electron Microscopy Sciences). Fixation of specimens was performed by adding 30 μL of ice-cold 3:1 4% paraformaldehyde:1x phosphate buffered saline (PBS ...
-
bioRxiv - Cancer Biology 2023Quote: Organoids were dissociated and 75,000 cells were replated overnight in 2D on 12 mm round #1 coverglass (Electron Microscopy Sciences 72231-01) coated with 75 μg/ml Poly-D-lysine followed by 3% Matrigel ...
-
bioRxiv - Cell Biology 2023Quote: ... The diluted sperm solution was mixed at a ratio of 1:1with 10 X concentrated 10 nm protein A-coated gold fiducials (Electron Microscopy Sciences). 2.7 μL of the mixture was applied onto the grids and blotted for 1.5 to 2.5 s in 100% relative humidity and 4 °C ...
-
bioRxiv - Cell Biology 2023Quote: ... The cell pellet was washed with PBS and fixed in 1 mL ice cold 4% PFA (Electron Microscopy Science, Hatfield, PA, USA) diluted in PBS ...
-
bioRxiv - Cell Biology 2022Quote: ... Samples were then washed in cytoskeletal buffer and fixed for 1 hour at room temperature in 4% formaldehyde (Cat# 1570, Electron Microscopy Sciences) in PBS ...
-
bioRxiv - Biochemistry 2024Quote: 3 μg of purified NHE9*CC sample was applied to freshly glow-discharged Quantifoil R2/1 Cu300 mesh grids (Electron Microscopy Sciences) and blotted for 3.0s with a 20s waiting time prior ...
-
bioRxiv - Plant Biology 2024Quote: ... the samples were washed five times for 10 min each with sterile deionized water and then transferred to fresh solution containing 1% (w/v) thiocarbohydrazide (EMS, Cat# 21900) in deionized water and incubated for 1 hour under rotation at room temperature ...