Labshake search
Citations for BMG Labtech :
1 - 50 of 184 citations for Mouse Cytochrome C Oxidase Subunit II COX2 MT CO2 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Bioengineering 2024Quote: ... 5% CO2 for 2 h after which MTS absorbance was measured at 490 nm using a plate reader (BMG Labtech Clariostar). For the LDH assay ...
-
bioRxiv - Microbiology 2023Quote: ... The cells were pelleted and the remaining cytochrome C in the supernatant was measured spectrophotometrically at OD410 using a FLUOstar OMEGA plate reader (BMG Labtech, UK).
-
Dual MAPK and HDAC inhibition rewires the apoptotic rheostat to trigger colorectal cancer cell deathbioRxiv - Cancer Biology 2021Quote: ... by incubating cells for 90 minutes at 37°C and measuring absorbance at 490 nm (MTS) and 630 nm (background absorbance) on a SPECTROstar Nano Spectrophotometer (BMG LabTech, Germany).
-
bioRxiv - Microbiology 2021Quote: ... Cells were incubated at 37°C and 5% CO2 in a CLARIOstar fluorescence plate reader (BMG Labtech) for the indicated time periods ...
-
bioRxiv - Microbiology 2021Quote: ... The plates were returned to 37°C/5% CO2 for 72 h and GFP signal imaged on a Mirrorball plate reader (BMG Labtech). The fluorescence signals of the test wells were normalized to percent activation relative to the average of the positive control wells on each plate by the formula:
-
bioRxiv - Cancer Biology 2023Quote: ... Absorbances of media containing MTS were then measured at 490nm using the ClarioStar plate reader (BMG LabTech). Each cell condition was measured every 24h over the course of 4d ...
-
bioRxiv - Systems Biology 2019Quote: ... Luciferase activity was measured over time in a CO2 luminometer (Lumistar Omega, BMG Labtech).
-
bioRxiv - Neuroscience 2020Quote: ... The ELISA was read on a PheraStar plate reader (BMG Labtech) as per the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2020Quote: ... ELISA absorbance acquisitions were acquired on a FLUOstar OPTIMA (BMG Labtech) and data were analyzed and exported to Excel with MARS Data Analysis Software (BMG Labtech).
-
bioRxiv - Biophysics 2022Quote: ... and 24h after OGD using a spectrophotometer (ELISA SPECTROstar Nano, BMG LABTECH). The MTS assay was repeated three times.
-
bioRxiv - Neuroscience 2024Quote: ... ELISA signal was detected by CLARIO star plate reader (BMG Labtech, Ortenberg, Germany).
-
bioRxiv - Neuroscience 2020Quote: ... ELISA plates were then read on a spectrophotometer plate reader (FLOUstar Omega, BMG Labtech). The ELISA protocol was originally described for its use in zebrafish (Cachat et al. ...
-
bioRxiv - Cell Biology 2019Quote: ... Optical density was read on a spectrophotometric ELISA plate reader (FLUOstar Omega, BMG Labtech) and analysed using MARS data analysis software.
-
bioRxiv - Immunology 2024Quote: ... ELISA plate was read an optical density (OD) at 405nm (ClarioStar instrument, BMG Labtech). Concentration of IgM (µg/mL ...
-
bioRxiv - Biophysics 2022Quote: ... OD at 450 nm was immediately read using a microplate reader (ELISA SPECTROstar Nano, BMG LABTECH).
-
bioRxiv - Neuroscience 2019Quote: ... 5% CO2 for 1 hour and viability was assessed by fluorescence reading (Exc 390/ Em 505 nm) at the PHERAstar (BMG Labtech). Ten μL of Steady-Glo Luciferase Assay System were subsequently added to each well ...
-
bioRxiv - Microbiology 2019Quote: ... Samples were acquired on a FACSCantoII (BC Biosciences, CA) or a FLUOstar Omega ELISA Reader (BMG Labtech).
-
bioRxiv - Biophysics 2020Quote: ... formazan crystals were dissolved in DMSO and absorbance was measured by spectrophotometer (ELISA SPECTROstar Nano, BMG LABTECH) at 570 nm wavelength for dissolved formazan and 690 nm for a background.
-
bioRxiv - Immunology 2021Quote: ... ELISA plate results were measured with light absorbance at 450 nm using a plate reader (Fluostar Omega, BMG labtech).
-
bioRxiv - Microbiology 2022Quote: ... The plate was then incubated at 30°C or 37°C in a SPECTROstar Omega plate reader (BMG LABTECH), with shaking and optical density measurements every 30 minutes.
-
bioRxiv - Immunology 2021Quote: ... The developing reaction was stopped by adding 50 μl 1 M H2SO4 and absorbance was measured at 450 nm with an ELISA microplate reader (FluoStar Omega 5.11, BMG Labtech) with Omega MARS software for analysis ...
-
bioRxiv - Immunology 2020Quote: ... then the developing reaction was stopped by adding 50μl 1M H2SO4 and absorbance was measured at 450nm with an ELISA microplate reader (FluoStar Omega, BMG Labtech). For plasma samples ...
-
bioRxiv - Immunology 2022Quote: ... The developing reaction was stopped by adding 50 μl of 1 M H2SO4 and absorbance was measured at 450 nm with an ELISA microplate reader (FluoStar Omega, BMG Labtech) with Omega and Omega MARS software for analysis ...
-
bioRxiv - Immunology 2021Quote: ... The developing reaction was stopped by adding 50 μl of 1 M H2SO4 and absorbance was measured at 450 nm with an ELISA microplate reader (FluoStar Omega, BMG Labtech) with Omega and Omega MARS software for analysis ...
-
bioRxiv - Immunology 2022Quote: ... then the developing reaction was stopped by adding 50 μl 1 M H2SO4 and absorbance was measured at 450 nm with an ELISA microplate reader (FluoStar Omega, BMG Labtech) with Omega and Omega MARS software for analysis ...
-
bioRxiv - Immunology 2022Quote: ... The developing reaction was stopped by adding 50 μl of 1 M H2SO4 and absorbance was measured at 450 nm with an ELISA microplate reader (FluoStar Omega, BMG Labtech) with Omega and Omega MARS software for analysis ...
-
bioRxiv - Immunology 2021Quote: ... then the developing reaction was stopped by adding 50 μl 1 M H2SO4 and absorbance was measured at 450 nm with an ELISA microplate reader (FluoStar Omega, BMG Labtech) with Omega and Omega MARS software for analysis ...
-
bioRxiv - Immunology 2022Quote: ... 50 μl of 1 M H2SO4 was used to stop the reaction and absorbance was measured at 450 nm with an ELISA microplate reader (FluoStar Omega, BMG Labtech) with Omega and Omega MARS software for analysis ...
-
bioRxiv - Neuroscience 2024Quote: ... The reaction was terminated by the addition of 100 µl of HCl 2N and the results were measured at 450 nm in a microtiter plate ELISA reader (FLUOstar OPTIMA, BMG LABTECH).
-
bioRxiv - Neuroscience 2020Quote: ... 4°C) using a Soniprep 150 (BMG Labtech, UK), centrifuged at 14000g and 4°C for 10 min ...
-
bioRxiv - Biochemistry 2021Quote: ... Color intensity was read at 450 nm with a reference filter of 570 nm in an ELISA plate reader (FLUOstar, BMG LABTECH, Inc., Cary, NC). IL-6 concentrations were extrapolated from a standard curve plotted using known concentrations of IL-6 ...
-
bioRxiv - Molecular Biology 2019Quote: ... at 30 °C using a FLUOstar Omega plate reader (BMG Labtech). ThT fluorescence was recorded by bottom reading every 5 min with excitation/emission wavelengths set to 440/480 nm ...
-
bioRxiv - Cell Biology 2020Quote: ... Incubation proceeded at 37°C inside ClarioSTAR microplate reader (BMG Labtech) with fluorescence emission at 515 nm being detected after 470 nm excitation 2.75 hours post GFP11 addition (the time at which peak fluorescence intensity was observed).
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... pH 7.4 at 30°C in a FLUOstar Omega plate reader (BMG Labtech). Progress curves were fitted by non-linear regression using OriginPro 2018 (OriginLab Corporation ...
-
bioRxiv - Biophysics 2020Quote: ... at 25 °C and fluorescence monitored in a microplate reader (BMG Labtech ClarioStar). Every well contained a 50-μL solution of 40 nM S-htelo in 20 mM Tris-HCl buffer (5 mM MgCl2 ...
-
bioRxiv - Biophysics 2020Quote: ... at 25 °C and fluorescence monitored in a microplate reader (BMG Labtech ClarioStar). To a 10-μL solution of 40 nM S-hTelo in 20 mM Tris-HCl buffer pH 7.2 (5 mM MgCl2 ...
-
Fatty acid binding proteins shape the cellular response to activation of the glucocorticoid receptorbioRxiv - Pharmacology and Toxicology 2021Quote: ... fluorescence polarisation was measured at 37°C using a PHERAstar FS (BMG Labtech) plate reader with fluorescence excitation and emission wavelengths set at 485 nm and 520 nm ...
-
bioRxiv - Neuroscience 2020Quote: ... Plates were then incubated at 37°C in a FLUOstar Omega (BMG Labtech Inc) by shaking at 200 rpm using the ‘meander corner well shaking’ mode ...
-
bioRxiv - Biophysics 2021Quote: ... Samples were incubated at 37 °C in a POLARstar Omega microplate reader (BMG Labtech), with excitation at 440 nm and the fluorescence emission recorded at 480 nm under quiescent conditions.
-
bioRxiv - Biochemistry 2021Quote: ... The measurements were performed at 37 °C using plate reader POLARstar OPTIMA (BMG LABTECH), which allows for the detection of signals using filters at 485-and 530-nm wavelengths ...
-
bioRxiv - Cell Biology 2022Quote: BRET measurements were performed at 37 °C using a PHERAstar Microplate Reader (BMG Labtech) with a dual-luminescence readout BRET1 plus filter (460-490 nm band-pass ...
-
bioRxiv - Microbiology 2023Quote: ... Plates were incubated at 37°C for 6h in a FLUOstar Omega (BMG Labtech) with fluorescence readings taken at 10 min intervals ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... BRET measurements were performed at 37 °C using a PHERAstar Microplate Reader (BMG Labtech) with a dual-luminescence BRET1 plus readout filter (460-490 nm band-pass ...
-
bioRxiv - Systems Biology 2024Quote: ... BRET measurements were performed at 37 °C using a PHERAstar Microplate Reader (BMG Labtech) with a dual-luminescence readout BRET1 plus filter (460-490 nm band-pass ...
-
bioRxiv - Bioengineering 2023Quote: ... and incubated at 30 °C in a plate reader (CLARIOstarPlus, BMG Labtech, Ortenberg, Germany). The optical density at 600 nm (OD600 ...
-
bioRxiv - Molecular Biology 2020Quote: ... Seeded assembly proceeded for 120 h at 37 °C in a FLUOstar Omega (BMG Labtech) microplate reader where the samples were alternatingly shaken for 1 minute at 400 rpm ...
-
bioRxiv - Biophysics 2022Quote: ... Samples were then incubated at 37 °C in a plate reader (Fluostar Optima, BMG Labtech). The fibrillation process was followed by monitoring the fluorescence over time for additional Aβ42 samples that were also supplemented with 20 μM ThT ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... which was incubated for 3 h at 37°C and 700 rpm (THERMOstar, BMG Labtech). From the preculture plate we used 5 μl to inoculate each of four different wells of a 384-well plate (Sigma-Aldrich ...
-
bioRxiv - Molecular Biology 2022Quote: ... All experiments were performed on a CLARIOstar Plus plate reader at 37°C (BMG Labtech).
-
bioRxiv - Microbiology 2023Quote: ... The plate was incubated at 37 °C in a FLUOstar Omega Microplate Reader (BMG LABTECH) with 300 rpm double-orbital shaking ...