Labshake search
Citations for Bel-Art :
51 - 100 of 139 citations since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... then 40μm (Bel-Art #H136800040) strainer to remove clumped cells ...
-
bioRxiv - Genomics 2023Quote: ... The nuclei pellet was resuspended with another 1 ml of RSB washing buffer and then transferred to a 1.5 ml LoBind tube through a 40 μm Flowmi Cell strainer (Bel-Art SP Scienceware, Cat. 14-100-150). The filtered nuclei were pelleted at 500 r.c.f for 5 min in a pre-chilled fixed-angle centrifuge and then resuspended in 25 μl of 1.25x Tagment DNA Buffer (Nextera XT Kit ...
-
bioRxiv - Genomics 2023Quote: ... The homogenate was filtered with a 70-um strainer filter (SP Bel-Art, cat no 136800070) and centrifuged for 5 minutes at 350 RCF ...
-
bioRxiv - Cancer Biology 2023Quote: ... Tumor volumes were determined with digital calipers (Bel-Art Products) using the formula (length*width*height) ...
-
bioRxiv - Developmental Biology 2023Quote: ... Cell suspensions were filtered through a use of Flowmi® micro strainer (SP Bel-Art; Wayne, NJ). LSC clusters were dissociated with trypsin-EDTA (0.05% ...
-
Single-cell analysis of shared signatures and transcriptional diversity during zebrafish developmentbioRxiv - Developmental Biology 2023Quote: ... Cells were filtered through a 40 uM FlowMi cell filter (Bel-Art H13680-0040) into a clean tube.
-
bioRxiv - Developmental Biology 2023Quote: ... Samples were filtered on Flowmi 70µm (Bel-Art H136800070) and analyzed on a Beckman Coulter Cytoflex LX (AMUTICYT platform) ...
-
bioRxiv - Cancer Biology 2023Quote: ... passed through 40 μm Flowmi cell strainer (Bel-Art, 974-25244), and assessed for concentration and viability with an automated cell counter ...
-
bioRxiv - Physiology 2023Quote: Quantitated and lyophilized protein samples were transferred as powder into NMR tubes (Catalog WG-4001-7, Bel-Art Products) and resuspended in 500 µL of water to final concentrations of 5 g/L ...
-
bioRxiv - Cancer Biology 2023Quote: ... the cells were filtered through a 40 um FLOWMI cell strainer (SP Bel-Art; H13680-0040). Whenever necessary ...
-
bioRxiv - Cell Biology 2023Quote: ... resuspended in 1 ml of organoid expansion media and filtered with 40 µm Flowmi cell strainers (SP Bel-Art, Wayne, NJ). Cells were transported to the UNM Analytical and Translational Genomics Core for counting and processing ...
-
bioRxiv - Cell Biology 2023Quote: ... Each cell sample was then passed through a 40 μm pipette tip cell strainer (FLOWMI; SP Bel-Art, Wayne, NJ). Living and dead cells were identified by simultaneously staining with green-fluorescent calcein-AM and red-fluorescent ethidium homodimer-1 ...
-
bioRxiv - Cell Biology 2023Quote: ... then filtered again using Flowmi 40 uM cell strainers (Bel-Art H13680-0040). After staining aliquots of each suspension with Trypan Blue to validate a minimum of 95% cell viability for each sample ...
-
bioRxiv - Neuroscience 2023Quote: ... and filtered through a 70 μm Flowmi Cell Strainer (Bel-Art, H13680-0070), and the cell number was counted ...
-
bioRxiv - Immunology 2023Quote: ... 10ml cells were used for counting with a hemocytometer and 10,000 cells were loaded in 40ml to the 10x chromium cell capture machine after running through a 40µm Flowmi cell strainer (Bel-art catalog no. H13680-0040) to remove clumped cells ...
-
bioRxiv - Cell Biology 2023Quote: ... The cell lyses was gently stirred with a Spinbar® magnetic stirring bar (Bel-Art Products), and the supernatant were collected every 5 minutes ...
-
bioRxiv - Genomics 2023Quote: ... or a 40 μm Flowmi strainer (SP Bel-Art, Warminster, PA, USA).
-
bioRxiv - Genomics 2023Quote: ... the frozen tissue was ground to a fine powder using a liquid nitrogen cooled mini mortar and pestle set (Bel-Art). The ground tissue was crosslinked first with 3 mM DSG and then with 1% formaldehyde ...
-
bioRxiv - Genomics 2023Quote: Tissue was pulverized inside a microtube while in a liquid-nitrogen cooled mini mortar and pestle (Bel-Art). DNA was then extracted with the Puregene DNA Kit (Qiagen ...
-
bioRxiv - Plant Biology 2023Quote: ... water was replaced with 500 μL of either water or water containing MAMP before pressure-infiltrating for 2 minutes at 30 mm Hg in a vacuum desiccator (SP Bel-Art #F42025-0000). Leaf disks were collected at 0 ...
-
bioRxiv - Molecular Biology 2023Quote: ... Resuspended pellets were filtered through a 40 μm flowmi filter (SP Bel-Art, Wayne, NJ), and measured for cell count and viability using the Cellometer Auto2000 (Nexcelom Bioscience ...
-
bioRxiv - Cell Biology 2023Quote: ... filtered using 40 μm FLOWMI cell strainer (Bel-Art) cell suspension into a 1.5 ml Eppendorf tube ...
-
bioRxiv - Neuroscience 2023Quote: ... Cells were resuspended in PBS with 0.4% DNase and filtered through a 70 μm Flowmi Cell Strainer (Bel-Art, H13680-0070). The samples were centrifuged at 200 x g for 3 minutes and were resuspended in Parse Cell Buffer containing BSA ...
-
bioRxiv - Neuroscience 2023Quote: ... The pellet was resuspended in 130 µL PBS + 0.2% BSA and filtered to remove cell clumps (Bel-Art, H13680-0040), resulting in the final single-cell suspension ...
-
bioRxiv - Neuroscience 2023Quote: ... The suspension from each sample was filtered through a 40um FlowmiTM strainer (Bel-Art), washed ...
-
bioRxiv - Genomics 2023Quote: ... and filtered using 40 μM P1000 Flowmi cell filters (SP Bel-Art, #136800040). After gating with forebrain tissue as a negative control ...
-
bioRxiv - Developmental Biology 2023Quote: ... Cells were resuspended in 200ul of the same solution and filtered with Flowmi Cell Strainers (70um, Bel-Art Products). Debris ...
-
bioRxiv - Developmental Biology 2023Quote: ... Cells were resuspended in 200ul of the same solution and filtered with Flowmi Cell Strainers (70um, Bel-Art Products). Cells were then incubated for 30 mins with LTL (Lotus Tetragonolobus Lectin Biotin conjugated 1:500) ...
-
bioRxiv - Bioengineering 2023Quote: ... In a glove box (Bel-Art, H50028-2001) filled with an atmosphere of medical-grade nitrogen ...
-
bioRxiv - Neuroscience 2023Quote: ... and filtered through FLOWMI tip strainer (Bel-Art Products, Cat# H13680-0040); more NSB was added as needed to help samples go through the FLOWMI tip ...
-
bioRxiv - Microbiology 2023Quote: ... using a sterile plastic pestle (Bel-Art Products, Inc., Wayne, NJ, USA). Larval water from trays containing fourth instar larvae was collected in 50 ml screw-cap tubes (Thermo Fisher Scientific ...
-
bioRxiv - Immunology 2023Quote: ... cells were resuspended in 100 ul and strained through a 40 μM filter (SP Bel-Art cat. H13680-0040). Each longitudinal pool was split across two 10X lanes while the “cross pool” was split across six 10X lanes (6 wells total ...
-
bioRxiv - Neuroscience 2022Quote: ... The suspension was filtered through a 40 µm Flowmi filter (Bel-Art H13680-0040) into a pre-wet 20 µm PluriStrainer (pluriSelect 43-10020-40 ...
-
bioRxiv - Bioengineering 2022Quote: ... The vacuum desiccator (Bel-Art SP™ Scienceware™ Lab Companion Round Style Vacuum Desiccator ...
-
bioRxiv - Neuroscience 2022Quote: ... the nuclei suspension was filtered twice through Flowmi Cell Strainers (Bel-Art, H13680-0040).
-
bioRxiv - Developmental Biology 2022Quote: ... Cells were passed through a 40µm filter (Bel-Art Flowmi, Cat#136800040), and centrifuged at 300g for 3 minutes at 4°C ...
-
bioRxiv - Neuroscience 2022Quote: ... nuclease free hand-held homogenizer (Bel-art) for ∼30 seconds on ice ...
-
bioRxiv - Cell Biology 2022Quote: ... Nuclei suspensions were passed through a 40 µm Flowmi filter (VWR Bel-Art SP Scienceware). Nuclei concentration was assessed using the LUNA-FL Dual Fluorescence Cell Counter.
-
bioRxiv - Cancer Biology 2022Quote: ... filtered through 70 μm (Flowmi, Bel-Art SP Scienceware, Wayne, NJ), followed by 40 μm filter (Flowmi) ...
-
bioRxiv - Cell Biology 2022Quote: Flash frozen liver tissue (20 mg) was pulverized with a mortar and pestle on liquid nitrogen (H37260-0100, Bel-Art Products), 80% methanol was added ...
-
bioRxiv - Developmental Biology 2022Quote: ... Cells were passed through a 40µm filter (Bel-Art Flowmi, Cat#136800040), and centrifuged at 300g for 3 min at 4°C ...
-
bioRxiv - Developmental Biology 2022Quote: ... The suspension was then filtered through a 40 μm Flowmi Cell strainer (Bel-Art H13680-0040). The filtered suspension was centrifuged at 2000 rpm for 5 min at 4°C ...
-
bioRxiv - Genomics 2022Quote: ... We then filtered cells with a 40 Flowmi™ Tip Strainer (H136800040, Bel-Art, Wayne, NJ). Cell suspensions were stored on ice and immediately transported to the Roy J ...
-
bioRxiv - Bioengineering 2022Quote: ... moved to a nitrogen-filled glove box (H50028-2001, Bel-Art), rehydrated with 200-300 μl ssDNA solution ...
-
bioRxiv - Developmental Biology 2022Quote: ... while stirring gently with a Spinbar® magnetic stirring bar (Bel-Art Products). Supernatants were collected every 5 min and neutralized with sheep serum ...
-
bioRxiv - Cancer Biology 2022Quote: ... The pellet was resuspended in wash buffer1 and filtered with a 40µm Flowmi cell strainer (Bel-Art). Nuclei were stained with DAPI 1:200 dilution (2µg/ml stock concentration ...
-
bioRxiv - Cancer Biology 2022Quote: ... Nuclear homogenates were filtered through a 70µm Flowmi cell strainer (Bel-Art) and centrifuged for 5 min at 500g ...
-
bioRxiv - Immunology 2022Quote: ... filtered using Flowmi 1000 uL pipette strainers (SP Bel-Art, Wayne, NJ), and resuspended in 300 uL FACS buffer.
-
bioRxiv - Genomics 2022Quote: ... the cell pellet was resuspended in 1 ml ice cold PBS/BSA and passed through a Flowmi cell strainer (Bel-Art, H13680-0040) into a clean precooled 15 ml Falcon tube ...
-
bioRxiv - Developmental Biology 2022Quote: ... 40 μm Flowmi Cell Strainers (Bel-Art, H13680-0040) were equilibrated by passing 100 μL of 0.04% PBS-BSA through the strainer using a P1000 pipette tip ...