Labshake search
Citations for Thermo Fisher :
1 - 50 of 3203 citations for Ion Exchange Chromatography since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Pathology 2024Quote: ... Pierce strong ion exchange columns (ThermoFisher) were used following supplier’s instructions ...
-
bioRxiv - Biochemistry 2021Quote: ... The Strep (II) elution fractions were further purified via ion exchange chromatography (Poros HQ 50 μm, Life Technologies) and subjected to size-exclusion chromatography in a buffer containing 50 mM HEPES pH 7.4 ...
-
bioRxiv - Biochemistry 2021Quote: ... The protein was additionally purified by ion-exchange chromatography on a “POROS HQ/20” 4.6×100 mm column (Applied Biosystems) using 0-20%B gradient over 12 column volumes at 0.5 ml/min flow rate using 20 mM Tris-HCl buffer (pH 8.9 at 25 °C ...
-
bioRxiv - Cell Biology 2022Quote: ... The Strep (II) and Ni-NTA elution fractions were further purified via ion exchange chromatography (Poros HQ 50 μm, Life Technologies) and subjected to size-exclusion chromatography in a buffer containing 50 mM HEPES pH 7.4 ...
-
bioRxiv - Immunology 2023Quote: ... The antibodies were captured from the cell supernatants using protein A resin (MabSelect SuRe, Cytiva), then purified by anion exchange chromatography (Capto Adhere, Cytiva) and cation exchange chromatography (Poros 50HS, Thermo Fisher).
-
bioRxiv - Molecular Biology 2020Quote: An untargeted analysis workflow was applied using a reagent-free ion exchange chromatography system with eluent generation (RFIC-EG) hyphenated with a high-field Orbitrap platform (Thermo Scientific, Bremen, Germany). The autosampler and columns were thermostated at 8 °C and 40°C ...
-
bioRxiv - Biochemistry 2022Quote: ... Before metabolite assay to each sample 140 pmoles of the appropriate standard was added and then selected metabolites were separated and quantitively analyzed with the use of an ion-exchange chromatography system (Dionex ICS-3000 chromatograph, Thermo Fisher Scientific Inc.) coupled with Waters ZQ mass spectrometer (Waters Corporation) ...
-
bioRxiv - Neuroscience 2023Quote: ... and analyzed via ion chromatography (Dionex Integrion, Thermofisher) as previously described [11].
-
bioRxiv - Microbiology 2020Quote: ... Major ion concentrations were determined by ion chromatography (Thermo Scientific Dionex capillary ICS-5000) (Hawkings et al. ...
-
bioRxiv - Cancer Biology 2023Quote: ... Using an Ion Chromatography System (ICS) 5000 (Thermo Scientific), 100 μl extract was loaded onto a Dionex IonPac AS11-HC-4μm anion-exchange column using a flow rate of 350 μl/min and separated using a 13 min gradient of 5-95 mM KOH ...
-
bioRxiv - Cancer Biology 2020Quote: ... the peptide pool was fractionated by Pierce Strong Ion Exchange Spin Columns (ThermoFisher). Briefly ...
-
bioRxiv - Plant Biology 2019Quote: ... high-performance anion exchange (HPAE) chromatography (ICS-5000, Thermo-Fisher Scientific) was used to analyze the neutral fraction of the extract ...
-
bioRxiv - Biochemistry 2023Quote: ... and the sample was loaded on the DNAPac PA200 ion exchange column (Thermo Fisher). Buffer A (2 mM Tris (pH 8.0) ...
-
bioRxiv - Microbiology 2023Quote: ... and sulfate (SO42-) using electrolytic-suppression ion chromatography (Dionex, Thermo Scientific; average recovery of standards was 10.3% ...
-
bioRxiv - Biophysics 2021Quote: ... The sample was loaded onto a 10-mL POROS HQ ion exchange column (Applied Biosystems) equilibrated with buffer B (60 mM NaCl ...
-
bioRxiv - Biochemistry 2024Quote: ... Ion exchange TBC-DEG purified fractions were then immediately concentrated using Amicon concentrators (Fisher Scientific) and then loaded on a HiLoad 16/600 Superdex-200 gel filtration column (GE Healthcare ...
-
bioRxiv - Plant Biology 2023Quote: The concentration of NO3− ions in tissues was determined using an ion chromatography system (Dionex Aquion, Thermo Fisher Scientific). Shoots of 14-day-old plants were powdered in liquid nitrogen and mixed with 1 ml of water to extract nitrate ...
-
bioRxiv - Microbiology 2022Quote: ... Sulfate concentrations were measured by an ICS-1100 ion chromatography (Thermofisher, USA) with an analytical error of ±1% ...
-
bioRxiv - Neuroscience 2023Quote: ... The samples were then transferred to ion chromatography vials (5 mL, Thermofisher) and analyzed via ion chromatography (Dionex Integrion ...
-
bioRxiv - Cancer Biology 2023Quote: ... Ion chromatography was performed using a Dionex ICS-5000+ system (ThermoFisher Scientific), which included a Thermo IonPac AS11 column (4-µm particle size ...
-
bioRxiv - Biochemistry 2019Quote: ... Ion exchange resin was recovered by filtration and washed successively with distilled H2O (Fisher Scientific, UK) at 60°C with two volumes of water and 10 volumes of 1 M NaCl at r.t ...
-
bioRxiv - Molecular Biology 2022Quote: ... in the positive ion mode with a Captivespray ion source on-line connected to a Dionex Ultimate 3000RSnano chromatography systems (Thermo Fisher). Peptides from rat tissue were separated on an Aurora column with captive spray insert (C18 1.6 uM particles ...
-
bioRxiv - Immunology 2020Quote: ... coupled to the chromatography system via a nano-electrospray ion source (Thermo Scientific). On the Q Exactive ...
-
bioRxiv - Cell Biology 2020Quote: ... connected to a high performance ion-chromatography system (ICS-5000+, Thermo Fisher Scientific) that enables us to perform highly selective and sensitive metabolite quantification owing to the IC-separation and Fourier Transfer MS principle ...
-
bioRxiv - Microbiology 2019Quote: ... pyruvate and sulfate concentrations using Ion Chromatography (Dionex ICS-5000+ DP, Thermo Scientific) as described previously [37].
-
bioRxiv - Immunology 2020Quote: ... coupled to the chromatography system via a nano-electrospray ion source (Thermo Scientific). On the Q Exactive ...
-
bioRxiv - Microbiology 2020Quote: ... Nitrite concentrations were determined by Ion Chromatography (Dionex IC-2500, Thermo Fisher Scientific).
-
bioRxiv - Bioengineering 2021Quote: ... and PO43- were measured by an ion chromatography (IC) (Thermo Fisher Scientific, USA) with Dionex ICS-2100 model ...
-
bioRxiv - Physiology 2022Quote: ... using an ion chromatography system connected to a conductivity detector (Dionex, Thermofisher Germany) and a triple quadrupole Mass Spectrometer QQQ6490 (Agilent Technologies ...
-
bioRxiv - Microbiology 2023Quote: ... Sulfate was measured by Dionex™ ICS-2100 Ion Chromatography System (Thermo Scientific), and sulfide was analyzed photometrically as previously described (22).
-
bioRxiv - Neuroscience 2024Quote: ... the remaining 100 µl were transferred to polypropylene autosampler vials (Chromatography Accessories Trott, Germany) before performing Anion exchange chromatography (Integrion, Thermo Fisher Scientific), coupled to high resolution mass spectrometry (Q-Exactive HF ...
-
bioRxiv - Physiology 2022Quote: The metabolite analysis was conducted using a Dionex ICS-5000 anion exchange chromatography (ThermoFisher Scientific). Separation was performed with a Dionex Ionpac AS11-HC column (2 mm x 250 mm ...
-
bioRxiv - Microbiology 2021Quote: ... Major ions (ammonium, sodium, potassium, calcium, magnesium, chloride, nitrate and sulphate) were determined using Ion Chromatography DIONX ICS-1100 (Thermo Scientific, USA). Total nitrogen and total organic carbon (TOC ...
-
bioRxiv - Biochemistry 2023Quote: ... in positive ion mode with a CaptiveSpray ion source on-line connected to a Dionex Ultimate 3000RSLC-nano chromatography system (Thermo Fisher Scientific). Peptides were separated on a 25 cm × 75 μm Aurora column (IonOpticks ...
-
bioRxiv - Plant Biology 2020Quote: ... Sea effluent water was analyzed by Ion chromatography IC-5000 (Dionex ICS-5000, ThermoFisher) with separator column (3×100 ...
-
bioRxiv - Neuroscience 2022Quote: ... The samples were analysed using a Dionex ion chromatography system (Integrion, Thermo Fisher Scientific) as described previously(90) ...
-
bioRxiv - Microbiology 2023Quote: ... and isocitrate were determined using a Dionex ICS-2100 ion chromatography system (Thermo Scientific) equipped with a Dionex™ IonPac™ AS11 IC column (Thermo Scientific ...
-
bioRxiv - Microbiology 2022Quote: ... Liquid chromatography tandem-mass spectrometry spectra were collected on a linear ion-trap instrument (ThermoFisher) (SPARC BioCentre ...
-
bioRxiv - Plant Biology 2023Quote: ... Chlorine (Cl-) concentration was measured using ion chromatography on a Dionex ICS-2100 (Thermo Scientific) equipped with a Dionex IonPac AS17 column (Thermo Scientific).
-
bioRxiv - Systems Biology 2023Quote: ... The bottom tips were packed sequentially with three plugs of C18 membrane (3 M Empore) and mixed-mode ion exchange beads (SCX:SAX = 1:1, Applied Biosystems). The quantity of C18 membrane and mixed-mode ion exchange beads was adjusted based on the protein amount.
-
bioRxiv - Microbiology 2022Quote: ... and NO3− concentrations were measured by ion chromatography (ICS1000 and Aquion, Thermo Fisher Scientific, Sunnyvale, CA). The exhausted gas in the aeration compartment was collected with an airtight syringe to measure gaseous N2O concentration using a quadrupole gas chromatography–mass spectrometry (GCMS-QP2010 Ultra ...
-
bioRxiv - Microbiology 2023Quote: ... and PO4 3− were measured by ion chromatography (IC) (Thermo Fisher Scientific, Dionex ICS-2100, USA) with anion and cation exchange columns ...
-
bioRxiv - Microbiology 2021Quote: ... The ion chromatography system comprised an ICS-5000+ SP pump (Thermo Fisher Scientific Inc. Sunnyvale, CA, USA), a column oven ICS-5000+ DC ...
-
bioRxiv - Microbiology 2021Quote: ... Monosaccharides present in hydrolyzed EPS were identified using Ion Chromatography System (Thermo Scientific Dionex ICS 5000+, UK) with AminoPac PA10 column (250 mm × 4 mm ...
-
bioRxiv - Bioengineering 2021Quote: ... Dionex ICS-2100 ion chromatography using a Dionex IonPac AS-18 IC column (Thermo Fisher Scientific, MA) was used to confirm ion selective electrode and colorimetric measurements of NO3- and NO2- concentrations ...
-
bioRxiv - Microbiology 2022Quote: ... Nitrate and sulfate were measured by a Dionex ICS-5000 Ion Chromatography System (Thermo Scientific, CA, USA) equipped with an anion-exchange column (Dionex IonPac AS22 ...
-
bioRxiv - Microbiology 2022Quote: ... The analyses of acidification metabolites were conducted through ion chromatography (IC) Dionex 2000 (Thermo Scientific, Sunnyvale, CA), which was equipped with an AS11 column (2 × 250 mm) ...
-
bioRxiv - Bioengineering 2019Quote: ... Concentrations of Cl- were identified using an ICS- 1100 ion chromatography system (Thermo Scientific Dionex, Bannockburn, United States). The underground water sample was collected in wells Z-159 ...
-
bioRxiv - Microbiology 2021Quote: The SO42− content was determined by anion exchange column chromatography using the ISC-2100 system (Thermo Fisher Scientific, USA, Massachusetts). The column was eluted via a gradient of 0–1.0 M KOH ...
-
bioRxiv - Microbiology 2021Quote: ... Metabolites were analysed by liquid anion exchange chromatography Dionex ICS-5000+ Reagent-Free HPIC (Thermo Fisher Scientific, Sunnyvale, CA, USA) system coupled to Thermo Scientific LTQ Orbitrap Velos hybrid FT mass spectrometer (Thermo Fisher Scientific ...