Labshake search
Citations for Thermo Fisher :
2601 - 2650 of 10000+ citations for Zinc Finger Protein 50 ZNF50 Blocking Peptide since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2023Quote: ... peptide concentration was also determined using NanoDrop 2000c Spectrophotometry (Thermo-Fisher Scientific, MA) to confirm concentrations determined by the BCA assay.
-
bioRxiv - Neuroscience 2023Quote: ... These peptides were desalted using Pierce C18 columns (Thermo Fisher Scientific, Cat#89870) following manufacturer’s protocol ...
-
bioRxiv - Biochemistry 2023Quote: ... Peptides were loaded on an Acclaim Pepmap trap column (Thermo Fisher Scientific #164750) with prior analysis on a PepMap RSLC C18 analytical column (Thermo Fisher Scientific #ES903 ...
-
bioRxiv - Cell Biology 2023Quote: ... Peptides were analysed in an Orbitrap Fusion Tribrid mass spectrometer (Thermo Fisher Scientific) in data-dependent mode ...
-
bioRxiv - Molecular Biology 2023Quote: Identification and quantification of peptides were performed in Proteome Discoverer 2.4 (Thermo Fisher) using a UniProt Drosophila melanogaster proteome database (downloaded February 6th ...
-
bioRxiv - Immunology 2023Quote: Eluting peptides were analyzed on an Exploris 480 Orbitrap mass spectrometer (Thermo Fisher) coupled to the column with a FAIMS pro ion-source (Thermo-Fisher ...
-
bioRxiv - Biochemistry 2023Quote: ... peptides were loaded onto a μPAC™ Neo trap column (Thermo Fisher Scientific) at a flow rate of 1 μL/minute using a gradient of 5-22.5% solvent B (0.1% FA ...
-
bioRxiv - Cancer Biology 2023Quote: ... Peptides were separated by LC and analyzed on a QExactive HF Orbitrap (ThermoFisher) mass spectrometer ...
-
bioRxiv - Neuroscience 2023Quote: ... Peptides were analyzed on a Q Exactive HF mass spectrometer (Thermo Fisher Scientific) online coupled to a UItimate 3000 RSLC nano-HPLC (Dionex) ...
-
bioRxiv - Biochemistry 2023Quote: Tryptic and peptic peptides were analyzed by Mascot/Proteome Discoverer 1.4 (Thermo Scientific). Raw files were searched against a SwissProt database containing 16.992 mus musculus entries and the manually added sequence of tagged PCRDtrunc ...
-
bioRxiv - Cancer Biology 2023Quote: ... The resolved peptides were ionized by an EASY-Spray ion source (Thermo Scientific), and mass spectra were acquired in a data-dependent manner (DDA ...
-
bioRxiv - Biochemistry 2023Quote: ... 0.2% FA and quantified using the Pierce™ Peptide Quantification (Thermo Fisher Scientific) assay as per the manufacturer’s instructions.
-
bioRxiv - Neuroscience 2023Quote: ... Resulting peptides were analyzed by nanoLC-MSMS using an easynLC1200 (Thermo Fisher Scientific) liquid chromatography system coupled with an Orbitrap Fusion Lumos mass spectrometer (Thermo Fisher Scientific) ...
-
bioRxiv - Neuroscience 2023Quote: ... Trypsin and peptide desalting columns were obtained as Pierce products from Thermo Fisher Scientific (Waltham ...
-
bioRxiv - Biophysics 2023Quote: ... peptides were desalted by flowing across a hand-packed trap column (Thermo Scientific POROS R2 reversed-phase resin 1112906 ...
-
bioRxiv - Molecular Biology 2023Quote: ... The peptides were injected into an integrated separation column/nanospray device (Thermo Scientific EASY-Spray PepMap RSLC C18 ...
-
bioRxiv - Cell Biology 2023Quote: ... Peptides were washed on pre-column (Acclaim™ PepMap™ 100 C18, ThermoFisher) with 60 μL of mobile phase A (0.1% FA in HPLC grade water ...
-
bioRxiv - Biochemistry 2023Quote: ... and digested peptides were purified with PierceTM C18 Spin Tips (Thermo Scientific #84850) according to the manufacturer’s protocol ...
-
bioRxiv - Biochemistry 2023Quote: ... Peptides were washed on pre-column (Acclaim™ PepMap™ 100 C18, ThermoFisher) with 60 μL of mobile phase A (0.1% FA in HPLC grade water ...
-
bioRxiv - Cell Biology 2024Quote: The tryptic peptides were resolved with the EASY-nLC 1000 (Thermo Fisher Scientific) connected to the Q-Exactive Orbitrap mass spectrometer (Thermo Fisher Scientific ...
-
bioRxiv - Developmental Biology 2024Quote: TMT-labeled peptides were analyzed on Orbitrap Eclipse Tribrid Mass Spectrometer (Thermo Scientific) with a FAIMS Pro interface ...
-
bioRxiv - Biochemistry 2024Quote: ... de-salted with a peptide cleanup C18 spin column (Thermo Scientific catalog #89870), then resuspended in 35 µL 0.1% formic acid (FA) ...
-
bioRxiv - Neuroscience 2024Quote: ... The peptides were separated by Ultimate 3000 LC system (Dionex, Thermo Scientific, USA) equipped with a reverse-phase trapping column RP-2TM C18 trap column (0.075 x 10mm ...
-
bioRxiv - Biochemistry 2024Quote: ... Eluting peptides were analyzed on an Orbitrap Exploris 480 instrument (Thermo Scientific™). The following MS settings were used ...
-
bioRxiv - Cancer Biology 2024Quote: ... Peptide separation was performed on the Vanquish Neo UHPLC System (Thermo Fisher Scientific) using established protocols [29] ...
-
bioRxiv - Cancer Biology 2024Quote: ... the peptides were then sprayed into the Q-Exactive mass spectrometer (Thermo Scientific) and survey scans of 45000 resolution (based on m/z 200 ...
-
bioRxiv - Neuroscience 2024Quote: ... Phospho-peptides were then dried in the SpeedVac (Thermo Fisher Scientific, Waltham, USA). For MS/MS-analysis ...
-
bioRxiv - Biochemistry 2024Quote: ... desalted peptides were injected in an Ultimate 3000 RSLCnano system (Thermo Fisher Scientific) and separated in a 25-cm analytical column (75µm ID ...
-
bioRxiv - Biochemistry 2024Quote: ... The eluted peptides were dried down in a vacuum concentrator (SpeedVac, ThermoFisher Scientific) and resuspended in 2% acetonitrile and 0.2% formic acid ...
-
bioRxiv - Microbiology 2024Quote: ... Peptide concentrations were determined using the Pierce Micro BCA assay (Thermo Scientific Pierce) according to the manufacturer’s instructions.
-
bioRxiv - Immunology 2024Quote: ... Peptide-MHC monomers were tetramerized by incubation with streptavidin-PE (BioLegend and Invitrogen), -BV421 ...
-
bioRxiv - Molecular Biology 2024Quote: ... The digested peptides were purified using a C18 spin column (Thermo Fisher Scientific), concentrated and dried via SpeedVac (Eppendorf) ...
-
bioRxiv - Plant Biology 2024Quote: ... The enriched peptides were desalted using 200 µl C18 StageTips (SP301, Thermo Scientific) that were supplemented with an additional layer of EmporeTM SPE Disk C18 material (66883-U Sigma-Aldrich) ...
-
bioRxiv - Physiology 2024Quote: ... peptides directly sprayed into an Orbitrap Ascend Tribrid mass spectrometer (Thermo Fisher Scientific). A synchronous precursor selection (SPS ...
-
bioRxiv - Cell Biology 2024Quote: ... Eluting peptides were analyzed on an Exploris 480 Orbitrap mass spectrometer (Thermo Fisher) coupled to the column with a FAIMS pro ion-source (Thermo-Fisher ...
-
bioRxiv - Cell Biology 2024Quote: ... The peptides were subsequently separated on an UltiMateTM 3000 HPLC System (ThermoFisher Scientific) using a 90 min gradient from 5-60% acetonitrile with 0.1% formic acid and directly sprayed via a nano-electrospray source in a quadrupole Orbitrap mass spectrometer (Q ExactiveTM ...
-
bioRxiv - Immunology 2024Quote: HLA peptides were separated by an Ultimate 3000 RSLC nano system (Thermo Scientific) using a PepMap C18 EASY-Spray LC column ...
-
bioRxiv - Genomics 2024Quote: ... Tryptic peptides were labeled using tandem mass tag isobaric labeling reagents (Thermo Fisher) following the manufacturer’s instructions and combined into one 16-plex TMT pro sample group ...
-
bioRxiv - Molecular Biology 2022Quote: ... wells were washed three times with PBS-T and three times with PBS and incubated with Quanta Red™ enhanced chemifluorescent HRP substrate (50:50:1, 50 μl per well, ThermoFisher Scientific, Waltham, MA, USA) at room temperature for 15 min ...
-
bioRxiv - Molecular Biology 2022Quote: ... For detection chitin magnetic beads were washed three times with 500 μl PBS-T and three times with 500 μl PBS before being taken up in 100 μl Quanta Red™ enhanced chemifluorescent HRP substrate (50:50:1, 50 μl per well, ThermoFisher Scientific, Waltham, MA, USA) and transferred to a black 96-well microtiter plate ...
-
bioRxiv - Genomics 2020Quote: ... and Protein A or Protein G Dynabeads (Invitrogen). After incubation ...
-
bioRxiv - Neuroscience 2019Quote: ... Protein reagent (Thermo Scientific PierceTM BCA Protein assay) was added to the supernatant and the standards and incubated for 30 min at 37°C ...
-
bioRxiv - Immunology 2022Quote: ... or with Dynabeads protein A/protein G (Thermofisher) combined with Abatacept ...
-
bioRxiv - Biochemistry 2021Quote: ... protein marker (NativeMark Unstained protein standard, LC0725, ThermoFisher) was diluted 50x in the working buffer (40 mM HEPES pH 7.5) ...
-
bioRxiv - Immunology 2020Quote: ... protein A and protein G magnetic beads (Invitrogen) were added to capture the antibody-chromatin complexes ...
-
bioRxiv - Immunology 2021Quote: ... For protein purification protein G dynabeads (Thermo Fisher), coupled with 2.5 µg of antibody (Table S8 ...
-
bioRxiv - Neuroscience 2022Quote: ... Magentic dynabeads Protein G or Protein A (Invitrogen) were washed with 0.05% Triton X-100 in PBS ...
-
bioRxiv - Developmental Biology 2022Quote: ... Protein A and Protein G Dynabeads (Thermofisher Scientific) were washed twice with IP dilution buffer (150 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Plant Biology 2022Quote: ... Magnetic Protein A and Protein G Dynabeads (Invitrogen) were added and incubated at 4°C for two hours ...
-
bioRxiv - Plant Biology 2022Quote: ... Magnetic Protein A and Protein G Dynabeads (Invitrogen) were added and incubated at 4 °C for 2 hours ...