Labshake search
Citations for Thermo Fisher :
2201 - 2250 of 5258 citations for MT ND1 Blocking Peptide since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2024Quote: ... Peptide samples (15.5 µg) were labelled with TMT10plex™ Isobaric Label (90406, Thermo Fisher Scientific) at 4:1 label-to-peptide ratio for 2 hr at room temperature and quenched with 0.5% (v/v ...
-
bioRxiv - Biochemistry 2023Quote: ... peptides were resolved with an analytical C18 column (Hypersil GOLD 1×50 mm, Thermo Scientific) and quickly eluted into a Bruker maXis-II ETD UHR ESI-QqTOF spectrometer at a flow rate of 40 μL/min for mass determination.
-
bioRxiv - Cell Biology 2023Quote: ... Purified peptide samples were measured on a Q Exactive HF mass spectrometer (Thermo Fisher Scientific) online-coupled to an Easy-nLC 1200 UHPLC (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2024Quote: ... digested peptide samples were labelled using TMT 16-plex isobaric mass tagging reagents (90063, ThermoFisher) for relative quantification ...
-
bioRxiv - Biochemistry 2024Quote: ... the peptides samples were fractionated using a Dionex Ultimate 3000 UPLC system (Thermo Fisher Scientific). Every 8th fractions were combined to a single pool and 12 such pools for each TMT-multiplexed sample set were analyzed by nanoLC-MS/MS as described before 22.
-
bioRxiv - Cancer Biology 2024Quote: Basic reversed-phase (bRP) fractionation of peptides was performed on a Vanquish HPLC (Thermo Scientific). In short ...
-
bioRxiv - Cancer Biology 2024Quote: Phosphorylated TMT-labeled peptides were measured on a Fusion Lumos Tribrid mass spectrometer (Thermo Scientific) coupled to a Dionex UltiMate 3000 RSLCnano System (Thermo Scientific ...
-
bioRxiv - Biophysics 2024Quote: ... 1µg peptides from each sample was introduced to MS using the Vanquish Neo (Thermo Scientific). The trapping column was PEPMAP NEO C18 (5 µm particle size ...
-
bioRxiv - Biochemistry 2023Quote: ... Peptides were analyzed through an Orbitrap Astral mass spectrometer (Thermo Fisher Scientific, the United States) using DIA mode under the liquid chromatography conditions and MS parameters suggested by the Thermo Fisher Scientific (technical note ...
-
bioRxiv - Immunology 2023Quote: ... Eluting peptides were directly sprayed onto the mass spectrometer Q Exactive HF (Thermo Fisher Scientific). Peptides were separated with a flow rate of 250nl/min by a gradient of buffer B (80% ACN ...
-
bioRxiv - Physiology 2022Quote: ... The digested peptides were labeled with iTRAQ reagent according to the manufacturer’s protocol (Applied Biosystems). In brief ...
-
bioRxiv - Pathology 2023Quote: ... The concentration of tryptic peptides was determined (Pierce BCA Protein Assay Kit, Thermo Fisher Scientific) and normalized across samples.
-
bioRxiv - Molecular Biology 2022Quote: ... Peptides were analyzed on a Q-Exactive HF hybrid quadrupole-Orbitrap mass spectrometer (Thermo Fisher) equipped with an Easy LC 1200 UPLC liquid chromatography system (Thermo Fisher) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Peptide fractions were analyzed on a quadrupole Orbitrap mass spectrometer (Q Exactive Plus, Thermo Scientific) equipped with a UHPLC system (EASY-nLC 1000 ...
-
bioRxiv - Molecular Biology 2022Quote: ... Peptides eluted from the column were analysed on an Orbitrap Fusion Lumos (Thermo Fisher Scientific) mass spectrometer ...
-
bioRxiv - Molecular Biology 2022Quote: Peptides were separated through reverse phase nano-HPLC on an Easy-nLC 1000 (Thermo Fisher) coupled on-line to a Thermo Fisher Orbitrap Exploris 480 mass spectrometer ...
-
bioRxiv - Genomics 2022Quote: ... and SAD hpNPCs were treated with 100µM of c-JUN peptide (19-891, Fisher Scientific) for 5 days in a proliferative condition ...
-
bioRxiv - Biochemistry 2023Quote: ... Acidified eluted peptides were analyzed on a QExactive HF-X mass spectrometer (Thermo Fisher Scientific) online coupled to a UItimate 3000 RSLC nano-HPLC (Dionex) ...
-
bioRxiv - Microbiology 2023Quote: ... to generate peak lists and protein and peptides identifications using Sequest HT (Thermo Fisher Scientific) and the ToxoDB release 49 GT1 protein database ...
-
bioRxiv - Molecular Biology 2023Quote: ... Peptide concentrations were determined by the Lowry protein assay using Folin & Ciocalteu Reagent (Thermo Fisher).
-
bioRxiv - Systems Biology 2023Quote: Peptides were separated using reversed-phase liquid chromatography (EASY nLC II 1200, Thermo Fisher Scientific) with self-made C18 microcolumns (20 cm long ...
-
bioRxiv - Molecular Biology 2023Quote: ... labelled AQUA version of the peptide derived from XUT0741 (AQUA Basic Heavy grade, Thermo Scientific). The sequence of the synthetic peptide was MPY(I)TNTAEATMSTV ...
-
bioRxiv - Cell Biology 2023Quote: ... All reported data were based on high-confidence peptides assigned in Proteome Discoverer (Thermo Scientific) with a 5% FDR by Percolator ...
-
bioRxiv - Cell Biology 2023Quote: ... Peptide concentration was estimated by measuring absorbance at A280 on a NanoDrop spectrophotometer (ThermoFisher Scientific).
-
bioRxiv - Cell Biology 2023Quote: ... Peptides were separated using a 75µm x 50cm C18 reversed-phase-UHPLC column (Thermo Scientific) on an Ultimate 3000 UHPLC (Thermo Scientific ...
-
bioRxiv - Cancer Biology 2023Quote: ... the peptide mixtures were extracted and desalted using Pierce C18 Spin Tips (Thermo Scientific, #84850) according to the manufacturer’s protocol ...
-
bioRxiv - Molecular Biology 2023Quote: ... resuspended in 50 mM TEAB and quantified using Pierce Quantitative fluorometric Peptide Assay (Thermo Scientific).
-
bioRxiv - Cell Biology 2023Quote: ... and fractionated using the Pierce high pH reversed-phase peptide fractionation kit (Thermo Fisher Scientific). Eight fractions were collected using 10% ...
-
bioRxiv - Microbiology 2023Quote: ... to generate peak lists and protein and peptides identifications using Sequest HT (Thermo Fisher Scientific) and the ToxoDB release 34 GT1 protein database ...
-
bioRxiv - Microbiology 2023Quote: ... to generate peak lists and protein and peptides identifications using Sequest HT (Thermo Fisher Scientific) and the ToxoDB release 49 GT1 protein database ...
-
bioRxiv - Biochemistry 2023Quote: ... Peptides were gradient eluted from the column directly to the Orbitrap Fusion Eclipse (Thermo Scientific) using a 88 min gradient with Solvent A (Water ...
-
bioRxiv - Biochemistry 2022Quote: ... which was separated using a high-pH reverse-phase peptide separation kit (Thermo Fisher Scientific). The mixed polypeptide sample was added to a chromatographic column and eluted with a solution of increasing acetonitrile concentration gradient ...
-
bioRxiv - Cell Biology 2022Quote: Peptide mixtures were analysed using an Ultimate 3000 RSLC nano liquid chromatography system (Thermo Scientific) coupled to a Fusion mass spectrometer (Thermo Scientific) ...
-
bioRxiv - Immunology 2023Quote: ... and the digested peptides were captured on a C18 PepMap300 trap column (Thermo Fisher Scientific) and desalted ...
-
bioRxiv - Biochemistry 2023Quote: ... Peptides were analyzed with an Orbitrap Fusion Lumos Tribrid Mass Spectrometer (Thermo Fisher Scientific, MA).
-
bioRxiv - Molecular Biology 2023Quote: ... Peptides were then analysed on mass spec with an EASY nanospray source (Thermo Fisher, MA) at an electrospray potential of 1.9 kV ...
-
bioRxiv - Cancer Biology 2023Quote: ... Tryptic peptides were labeled using tandem mass tag isobaric labeling reagents (Cat. No. A34808, ThermoFisher) following the manufacturer’s instructions and combined into one 11-plex sample group ...
-
bioRxiv - Cancer Biology 2023Quote: ... and 10 μg of peptide per sample was labeled with TMTpro reagents (Thermo Scientific, A44520). TMT labeled samples were adjusted to equal amounts and pooled ...
-
bioRxiv - Immunology 2022Quote: ... Peptides were eluted in positive ion mode into an Orbitrap Elite mass spectrometer (Thermo Fisher) via a Nanospray Flex Ion Source (Thermo Fisher) ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... peptides were labeled with TMT 16-plex reagents according to manufacturer’s protocol (Thermo Scientific Pierce). After quenching ...
-
bioRxiv - Microbiology 2023Quote: ... Eluting peptides were analyzed on an Orbitrap Exploris 480 mass spectrometer (Thermo Fisher Scientific, USA) as described [56].
-
bioRxiv - Biochemistry 2023Quote: ... Peptides were analyzed with an Orbitrap Fusion Lumos Tribrid Mass Spectrometer (Thermo Fisher Scientific, MA).
-
bioRxiv - Cancer Biology 2023Quote: ... Analysis of peptides was carried out on an Orbitrap Fusion Lumos MS platform (Thermo Scientific) coupled to an Easy-nLC 1200 system (Thermo ...
-
Borrelia PeptideAtlas: A proteome resource of common Borrelia burgdorferi isolates for Lyme researchbioRxiv - Biochemistry 2023Quote: ... Peptides were chromatographically separated on a 50-cm analytical column [(EASY-Spray ES803A, Thermo Scientific); 75 µm × 50 cm ...
-
bioRxiv - Biophysics 2023Quote: Peptides of Ub (WT, L67A, L69A) were identified via LC-MS/MS (ThermoFisher Orbitrap Fusion). The raw data were imported into Proteome Discover 2.4 software to identify high-score peptides ...
-
bioRxiv - Cell Biology 2023Quote: An equal amount (54 µg, determined by Pierce Quantitative Fluorometric peptide assay, 23275, Thermo Scientific) of peptides from each sample was subjected to isobaric labelling using Tandem Mass Tag (TMT-10plex ...
-
bioRxiv - Microbiology 2023Quote: ... to generate peak lists and protein and peptide IDs using Sequest HT (Thermo Fisher Scientific) and the ToxoDB release 49 GT1 protein database ...
-
bioRxiv - Cell Biology 2023Quote: ... and peptides were separated using a 25 cm EasySpray nanoLC column (Thermo Fisher Scientific ES902) protected by a 2 cm Acclaim PepMap 100 guard column (Thermo Fisher Scientific 164946) ...
-
bioRxiv - Plant Biology 2023Quote: Tryptic peptide mixtures were analyzed by LC/MS/MS using nanoflow Easy-nLC1000 (Thermo Scientific) as an HPLC-system and a Quadrupole-Orbitrap hybrid mass spectrometer (Q-Exactive Plus ...
-
bioRxiv - Plant Biology 2023Quote: ... Resulted peptides were separated in a nano-HPLC (EASY-nLC 1000, Thermo Fisher Scientific, Germany) coupled to a mass spectrometer with Orbitrap technology (Q-Exactive with High Collision Dissociation cell and Orbitrap analyzer ...