Labshake search
Citations for Thermo Fisher :
1951 - 2000 of 4833 citations for Tryptase gamma Blocking Peptide since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2021Quote: Peptide samples were separated on a Thermo Scientific™ Ultimate™ 3000 UHPLC (ThermoFisher Scientific) using a 10 min loading at 3 µL/min flow rate to a trap column (Acclaim™ PepMap™ 100 ...
-
bioRxiv - Biochemistry 2021Quote: Tryptic peptides (1 μg) were analyzed with an LTQ-Orbitrap Velos ETD (Thermo Fisher Scientific) coupled with Easy NanoLC II (Thermo Scientific) ...
-
bioRxiv - Biochemistry 2021Quote: TMT-labelled high pH peptide fractions were analysed by Orbitrap™ Eclipse MS (Thermo Scientific) with on-line separation on a reversed-phase nanoLC column (450mm × 0.075mm ID ...
-
bioRxiv - Cancer Biology 2020Quote: ... The conjugated peptide was intracutaneously injected with Imject™ Freund’s Complete Adjuvant (Themo Fisher SCIENTIFIC) into the footpads of anesthetized eight-week-old female rats ...
-
bioRxiv - Cell Biology 2020Quote: ... The peptides recovered were analyzed with a Q Exactive Plus mass spectrometer (Thermo Fisher Scientific) coupled on-line with a capillary high-performance liquid chromatography (HPLC ...
-
bioRxiv - Cell Biology 2019Quote: ... the peptides were separated by C18 reversed phase chromatography with an Easy nLC 1200 (ThermoFisher) coupled to a Q Exactive HF mass spectrometer (ThermoFisher) ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... and the peptide concentration was quantified using a Nanodrop 2000 spectrophotometer (Thermo Fisher Scientific, USA). LC-MS/MS analysis was performed on an Easy-nLC 1200 (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: ... Peptides separated using a chromatographic system connected to an Eclipse Tribrid Orbitrap mass spectrometer (ThermoFisher). Raw data files were processed for protein identification using MaxQuant (version 1.6.3.4 ...
-
bioRxiv - Immunology 2020Quote: For peptide identification Mascot (57) integrated into proteome discoverer (v2.2 Thermo Fisher Scientific, MA, USA) was used to search peak lists against the H ...
-
bioRxiv - Microbiology 2020Quote: All peptide analyses were performed on a Q Exactive Plus mass spectrometer (Thermo Fisher Scientific) connected to an EASY-nLC 1000 ultra-high-performance liquid chromatography system (Thermo Fisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: ... Peptides eluted from the C18 column were analyzed by Q-Exactive instruments (Thermo Fisher Scientific) using an electrospray voltage of 1.9 kV ...
-
bioRxiv - Immunology 2021Quote: ... peptides were separated using PepMap C18 (3 μm, 100 Å, Thermo Fisher Scientific, MA, USA) and analysed using a Dionex Ultimate 3000 RSLCnano system coupled to a Q Exactive tandem mass spectrometry (Thermo Fisher Scientific ...
-
bioRxiv - Immunology 2020Quote: ... For separation of peptides Hypersil gold C18 (100x2.1 mm; particle size: 1.9 µm, ThermoFisher, USA) column was used ...
-
bioRxiv - Microbiology 2021Quote: For MS analysis peptides were loaded on an EASY-nLC 1000 system (Thermo Fisher Scientific) equipped with an in-house built 20 cm column (inner diameter 100 µm ...
-
bioRxiv - Plant Biology 2021Quote: ... Peptide separation was carried out on an Ultimate 3000 rapid separation system (Thermo Fisher Scientific) on 25 cm long C18 columns using a 54 min separation gradient (2 h for G ...
-
bioRxiv - Neuroscience 2021Quote: ... monomeric peptide was diluted to ∼400 µl (100 µM final concentration) in Neurobasal medium (GIBCO), incubated 24-48 hours at 4° C with rocking ...
-
bioRxiv - Biochemistry 2021Quote: ... peptides were loaded onto a nanoHPLC-MS/MS system (Dionex Ultimate 3000 UHPLC; Thermo Scientific) coupled to a Q-Exactive hybrid quadrupole orbitrap mass spectrometer (Thermo Scientific) ...
-
bioRxiv - Microbiology 2020Quote: ... tryptic peptides were reconstituted and analyzed on an Orbitrap Fusion Tribrid mass spectrometer (Thermo Scientific) following the parameters described in (42) ...
-
bioRxiv - Immunology 2022Quote: ... Eluting peptides were directly analyzed on a Q-Exactive HF mass spectrometer (Thermo Fisher Scientific) operated in data-dependent acquisition mode with repeating cycles of one MS1 full scan (300-1 650 m/z ...
-
bioRxiv - Immunology 2022Quote: ... Peptides were first loaded onto either Acclaim PepMap RSLC NanoTrap column (Dionex; Thermo Fisher Scientific) or a prior to separation on a 75 μm×15 cm Acclaim PepMap RSLC C18 column (Dionex ...
-
bioRxiv - Cell Biology 2022Quote: ... The digested peptides were then desalted using Pierce C18 tips (Thermo Fisher Scientific, Waltham, MA), dried and resuspended in 5% formic acid ...
-
bioRxiv - Cell Biology 2022Quote: ... was carried out as follows: biotinylated peptides were incubated with streptavidin conjugated Dynabeads (65001, ThermoFisher) for 30 min RT followed by 2 h incubation with supernatant ...
-
bioRxiv - Biochemistry 2022Quote: ... Peptides were separated on a 5.5 cm brick shape pillar column prototype (μPACTM, Thermo Fisher) or on a nanoEase M/Z Peptide CSH C18 column (130Å ...
-
bioRxiv - Biophysics 2022Quote: Peptide fragments were identified using LC-MS/MS with a LTQ Orbitrap XL (Thermo Scientific). Full-scan mass spectra were obtained in positive mode (m/z = 350 to 1800 ...
-
bioRxiv - Biochemistry 2022Quote: ... Eluted peptides were analyzed by QExactive HF or Fusion Tribrid mass spectrometer (Thermo Fisher Scientific). MS1 spectra were acquired using Orbitrap mass analyzer at the resolution of 60,000 (QExactive HF ...
-
bioRxiv - Biochemistry 2022Quote: ... peptides were then injected into an Orbitrap Exploris™ 480 mass spectrometer (Thermo Fisher Scientific). Samples were scheduled in triplicates and a subsequent washing step while the column temperature was constantly at 60°C ...
-
bioRxiv - Cell Biology 2022Quote: ... Peptide fractions were analyzed on a quadrupole Orbitrap mass spectrometer (Q Exactive Plus, Thermo Scientific) equipped with a UHPLC system (EASY-nLC 1000 ...
-
bioRxiv - Cell Biology 2022Quote: ... and the resulting peptides were separated on an EASY-nLC 1200 system (Thermo Fisher Scientific). The nano liquid chromatography gradient was as follows ...
-
bioRxiv - Cell Biology 2022Quote: ... Peptide reverse phase offline fractionation was performed on a Dionex Ultimate 5000 HPLC (Thermo Scientific) as described previously (Udeshi et al. ...
-
bioRxiv - Cancer Biology 2022Quote: Reserved peptides were enriched with High-Select™ TiO2 phosphopeptides enrichment kit from Thermo Scientific (Cat No ...
-
bioRxiv - Developmental Biology 2022Quote: ... Resuspended peptides were desalted using 100 μl Pierce™ C18 pipette tips (Thermo Scientific™) following the manufacturer’s instructions ...
-
bioRxiv - Immunology 2022Quote: ... native control peptides and control antigens using a custom-designed antigen microarray (ThermoFisher Scientific, Immunodiagnostics)9 ...
-
bioRxiv - Microbiology 2022Quote: ... peptide lysate was injected into a nanoLC system (UltiMate 3 000, Dionex, Thermo Fisher Scientific). Peptides were first trapped for 3 min on a C18-reverse phase trapping column (Acclaim PepMap® 100 ...
-
bioRxiv - Systems Biology 2022Quote: ... Separation of peptides was performed on an Ultimate 3000 Nano LC System (Thermo Fisher Scientific), coupled to a Q Exactive HF mass spectrometer (Thermo Fisher Scientific ...
-
bioRxiv - Plant Biology 2022Quote: ... Two rabbits were immunized by injecting two synthetic peptides: GRRKRESGA and STKSGIKRIGEEKN (Thermo Fisher Scientific). Sera before peptide co-injection and 72 days after co-injection were used as primary antibodies to check for specific bands in infected compared to non-infected roots ...
-
bioRxiv - Neuroscience 2023Quote: ... we used a high pH reverse-phase peptide fractionation kit (Thermo Fisher Scientific, Cat # 84868) to get eight fractions (5.0% ...
-
bioRxiv - Plant Biology 2022Quote: ... Then 1μg of peptides was separated by an online reversed-phase (RP) HPLC (Thermo Scientific Dionex Ultimate 3000 RSLC nano LC system ...
-
bioRxiv - Genetics 2022Quote: Peptide and protein identification and quantification was conducted using Proteome Discoverer 2.2 (PD 2.2, ThermoFisher) based on the human reference database UniProt (http://www.uniprot.org) ...
-
bioRxiv - Biochemistry 2022Quote: ... The peptide concentration was spectrophotometrically determined at 280 nm using a NanoDrop instrument (Thermo Scientific) and the equivalent of 500 ng of each sample were loaded onto Evotips (Evosep ...
-
bioRxiv - Pathology 2023Quote: ... The concentration of tryptic peptides was determined (Pierce BCA Protein Assay Kit, Thermo Fisher Scientific) and normalized across samples.
-
bioRxiv - Molecular Biology 2022Quote: ... Peptides were analyzed on a Q-Exactive HF hybrid quadrupole-Orbitrap mass spectrometer (Thermo Fisher) equipped with an Easy LC 1200 UPLC liquid chromatography system (Thermo Fisher) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Peptide fractions were analyzed on a quadrupole Orbitrap mass spectrometer (Q Exactive Plus, Thermo Scientific) equipped with a UHPLC system (EASY-nLC 1000 ...
-
bioRxiv - Molecular Biology 2022Quote: ... Peptides eluted from the column were analysed on an Orbitrap Fusion Lumos (Thermo Fisher Scientific) mass spectrometer ...
-
bioRxiv - Molecular Biology 2022Quote: Peptides were separated through reverse phase nano-HPLC on an Easy-nLC 1000 (Thermo Fisher) coupled on-line to a Thermo Fisher Orbitrap Exploris 480 mass spectrometer ...
-
bioRxiv - Genomics 2022Quote: ... and SAD hpNPCs were treated with 100µM of c-JUN peptide (19-891, Fisher Scientific) for 5 days in a proliferative condition ...
-
bioRxiv - Immunology 2023Quote: ... Eluting peptides were directly sprayed onto the mass spectrometer Q Exactive HF (Thermo Fisher Scientific). Peptides were separated with a flow rate of 250nl/min by a gradient of buffer B (80% ACN ...
-
bioRxiv - Physiology 2022Quote: ... The digested peptides were labeled with iTRAQ reagent according to the manufacturer’s protocol (Applied Biosystems). In brief ...
-
bioRxiv - Cancer Biology 2023Quote: ... Analysis of peptides was carried out on an Orbitrap Fusion Lumos MS platform (Thermo Scientific) coupled to an Easy-nLC 1200 system (Thermo ...
-
bioRxiv - Biophysics 2023Quote: Peptides of Ub (WT, L67A, L69A) were identified via LC-MS/MS (ThermoFisher Orbitrap Fusion). The raw data were imported into Proteome Discover 2.4 software to identify high-score peptides ...
-
bioRxiv - Biochemistry 2023Quote: ... Peptides were analyzed with an Orbitrap Fusion Lumos Tribrid Mass Spectrometer (Thermo Fisher Scientific, MA).