Labshake search
Citations for Thermo Fisher :
801 - 850 of 3609 citations for Super Resolution microscope since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genetics 2021Quote: ... Total long chain fatty acids were analyzed using a Waters Acquity i-class UPLC coupled with a QExactive high resolution accurate-mass spectrometer (HRAM-MS, Thermo Scientific, Waltham, MA) with heated electrospray ionization (HESI-II ...
-
bioRxiv - Biochemistry 2020Quote: The double bonds of intact glycerophospholipids were determined via mass spectrometry using a modified Orbitrap Elite high-resolution mass spectrometer (Thermo Scientific, Bremen, Germany) capable of ozone-induced dissociation ...
-
bioRxiv - Bioengineering 2021Quote: The spatial resolution of CHAMP was measured by imaging 500-nm-diameter fluorescent beads (B500, excitation/emission: 365/445 nm, Thermo Fisher Scientific Inc.) (Supplementary Fig ...
-
bioRxiv - Synthetic Biology 2021Quote: ... the production of target natural product was qualitatively analysed using a high-resolution Q-Exactive Hybrid Quadrupole-Orbitrap mass spectrometer (Thermo Scientific, Waltham, MA).
-
bioRxiv - Systems Biology 2022Quote: Identification and quantification of nucleotides were performed using an ACQUITY UPLC chromatography system (Waters, UK) coupled online to a high-resolution Orbitrap mass spectrometer (Q-Exactive Focus, Thermo Fisher Scientific, Germany). For chromatographic separation ...
-
bioRxiv - Bioengineering 2022Quote: CSI data reconstructed in MATLAB was zero-filled to 0.5-mm isotropic resolution for volumetric and signal analysis in Amira 3D Visualization Software (Thermo Fisher Scientific, Waltham, MA). A signal threshold generated from the contralateral hemisphere was used to define the ischemic lesion:
-
bioRxiv - Microbiology 2020Quote: ... The total lipid extract was analyzed on an Agilent 1200 reversed phase high performance liquid chromatograph (HPLC) coupled to a ThermoFisher Exactive Plus Orbitrap high resolution mass spectrometer (HRMS; ThermoFisher, Waltham, MA, USA). HPLC and MS conditions are described in Collins et al. ...
-
bioRxiv - Microbiology 2020Quote: ... Samples were injected on a Dionex RSLC 3000 nanoHPLC system (Dionex, Sunnyvale, CA, USA) interfaced via a nanospray source with a high-resolution mass spectrometer QExactive Plus (Thermo Fisher, Bremen, Germany). Peptidoglycan fragments were loaded onto a trapping microcolumn Acclaim PepMap100 C18 (20 mm x 100 μm ID ...
-
bioRxiv - Molecular Biology 2020Quote: ... were analyzed on a high resolution Q Exactive HF Hybrid Quadrupole - Orbitrap Mass Spectrometer equipped with a heated electrospray ionization (HESI)-II source (Thermo Scientific, Rockford, IL) and a Vanquish Horizon UHPLC system (Thermo Scientific ...
-
bioRxiv - Microbiology 2020Quote: ... The grid was screened at the cryo-EM facility at CSSB (Hamburg, Germany) and high-resolution cryo-EM data were collected on a Titan Krios operated at 300 kV (Thermo Fisher Scientific FEI) equipped with a K3 direct detection camera (Gatan ...
-
bioRxiv - Microbiology 2019Quote: ... or a Q-Exactive High Resolution/Accuracy Mass Spectrometer with a heated electrospray ionization (HESI-II) source and an Orbitrap Mass Analyzer (ThermoFisher, Waltham, MA, USA). A detailed description of methods and procedure for data acquisition ...
-
bioRxiv - Microbiology 2020Quote: ... High-resolution experiments were performed with a Vanquish HPLC system coupled to an Orbitrap Qexactive+ mass spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) equipped with a heated electrospray ionization probe ...
-
bioRxiv - Physiology 2021Quote: Sample peptides were processed using an externally calibrated high-resolution electrospray tandem mass spectrometer (Thermo Q Exactive HF; Thermo Fisher Scientific, Waltham, MA) in conjunction with a Dionex UltiMate 3000 RSLCnano System (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2022Quote: ... Five μL of the above sample was infused by nESI direct infusion using a TriVersa NanoMate (Advion Biosciences, Ithaca, NY, USA) coupled to a Q-Exactive Plus high-resolution MS (Thermo Scientific, MA, USA) (nESI-DIMS ...
-
bioRxiv - Plant Biology 2022Quote: ... MS spectra were acquired from 1-20 min by Thermo Scientific Q Exactive in Full MS mode (resolution 70000, max. injection time 100 ms, automatic gain control value 3E6; Thermo Fisher Scientific, Waltham, USA) in the scan range 100-1500 m/z ...
-
Tryptophan specialized metabolism and ER body-resident myrosinases modulate root microbiota assemblybioRxiv - Plant Biology 2022Quote: The LC-MS system consisted of UPLC with a photodiode-array detector PDAeλ (Acquity System; Waters) hyphenated with a high-resolution QExactive hybrid MS/MS quadrupole Orbitrap mass spectrometer (Thermo Scientific, http://www.thermofisher.com/). Chromatographic profiles of metabolites and the quantitative measurements were obtained using water acidified with 0.1% formic acid (solvent A ...
-
bioRxiv - Microbiology 2022Quote: ... Identification and quantification of choline and TMAO was performed using a uHPLC (Dionex 3000) coupled to a high-resolution mass spectrometer (Thermo Scientific Q Exactive). Liquid chromatography separation was achieved on a Dikma Bio-Bond C4 column (150 mm by 2.1 mm ...
-
bioRxiv - Biophysics 2023Quote: ... The HPLC was connected to an Orbitrap Fusion Tribrid in positive ESI MS only mode (Orbitrap resolution 120,000, 4 microscans, Thermo Scientific, Waltham, MA, USA).
-
bioRxiv - Systems Biology 2023Quote: ... raw files generated by the QExactive™ HF hybrid quadrupole orbitrap high-resolution mass spectrometer were checked manually using the Xcalibur™ Qual Browser software (version 4.1.31.9, Thermo Fisher Scientific™, Bremen, Germany) by comparing reference spectra from the LIPIDMAPS depository library from July 2020.75 In general ...
-
bioRxiv - Immunology 2023Quote: Metabolites were analyzed for relative abundance by high resolution accurate mass detection (HRAM) on two QExactive™ Orbitrap mass spectrometers (Thermo Fisher Scientific) coupled to Thermo Vanquish liquid chromatography systems as previously described (18) ...
-
bioRxiv - Biochemistry 2023Quote: High resolution accurate mass analysis was performed on an Thermo Scientific™ Orbitrap Ascend™ Tribrid™ mass spectrometer (Thermo Fisher Scientific, CA.) interfaced with a heated electrospray (H-ESI ...
-
bioRxiv - Physiology 2023Quote: ... metabolites Metabolites were analyzed for relative abundance by high resolution accurate mass detection (HRAM) on two QExactive™ Orbitrap mass spectrometers (Thermo Fisher Scientific) coupled to Thermo Vanquish liquid chromatography systems ...
-
bioRxiv - Neuroscience 2023Quote: ... untargeted mass spectrometry analyses were performed on a high-resolution Q-Exactive HF hybrid quadrupole-Orbitrap mass spectrometer (Thermo Fisher Scientific, Bremen, Germany) equipped with a Vanquish UHPLC binary system (Thermo Fisher Scientific ...
-
bioRxiv - Plant Biology 2023Quote: ... samples were injected to a Orbitrap high-resolution mass spectrometer:Fourier-transform mass spectrometer (FT-MS) attached to a linear ion trap (LTQ) Orbitrap XL (ThermoFisher Scientific, Waltham, MA, U.S.A.). To obtain mass spectra ...
-
bioRxiv - Microbiology 2022Quote: ... RT-qPCR was performed using 1 μg each of total RNA as template for reverse transcription reaction with Super Script III (Thermo Fisher Scientific, USA). 4 μL from the 100-μL cDNA samples were subjected to RT-qPCR with appropriate primer sets shown in Table S1 and Fast SYBR Green Master Mix (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2019Quote: ... Following washes by 0.1% Tween-20 in TBS the detection of the target proteins was carried out using Super Signal West Femto (Thermo Fisher Scientifics, 34095) and ChemiDoc imaging system (BioRad).
-
bioRxiv - Cell Biology 2019Quote: ... Following washes by 0.1% Tween-20-1X TBS the detection of the target proteins was carried out using Super Signal West Femto (Thermo Fisher Scientifics, 34095) and ChemiDoc imaging system (BioRad).
-
bioRxiv - Neuroscience 2019Quote: ... 16 μm coronal sections of VP were cut using a cryostat and mounted directly onto Super Frost Plus slides (Fisher Scientific, NH, USA). Slides were stored at −80 °C until use ...
-
bioRxiv - Cell Biology 2020Quote: ... Following washes by 0.1% Tween-20-1X TBS the detection of the target proteins was carried out using Super Signal West Femto (Thermo Fisher Scientifics, 34095) and ChemiDoc imaging system (BioRad).
-
bioRxiv - Plant Biology 2022Quote: ... approximately 700 ng of total RNA was denatured at 65°C for 5 min and then reverse-transcribed using the Super-Script II kit (Invitrogen, Carlsbad, CA, USA) at 25°C for 10 min ...
-
bioRxiv - Plant Biology 2022Quote: ... membranes were washed with TBST buffer and the chemiluminescence of the protein samples was visualized using Super Signal West Femto reagents (Thermo Scientific, Waltham, USA) through Image Quant LAS500 (GE Healthcare ...
-
A new vulnerability to BET inhibition due to enhanced autophagy in BRCA2 deficient pancreatic cancerbioRxiv - Cancer Biology 2023Quote: ... The membranes were then incubated in primary antibody overnight with rocking at 4°C followed by incubation in appropriate secondary antibodies conjugated to horseradish peroxidase (1:5000) for 1 hr and detection by Super Signal West Pico PLUS Chemiluminescent Substrate (Thermo Fisher Scientific, 34577). Primary antibodies used were ...
-
bioRxiv - Cancer Biology 2023Quote: ... PB-CAGGS-dCas9-KRAB- MeCP2 was co-transfected with the Super PiggyBac transposase expression vector (SPBT) into PEO1-OR cells using Neon Transfection System (Thermo Fisher, Cat. #MPK5000). The pB-CAGGS- dCas9-KRAB-MeCP2 construct was a gift from Alejandro Chavez & George Church (Addgene plasmid # 110824) ...
-
bioRxiv - Plant Biology 2024Quote: ... We conducted quantitative reverse transcription PCR (qRT-PCR) with three technical replicates for each sample using SYBR Green super mix dye (Thermo Fisher Scientific™) and the CFX Opus 384 and Bio-Rad CFX Maestro platforms ...
-
bioRxiv - Molecular Biology 2022Quote: Microscope slides (Fisher Scientific, #12550003) were prepared by drawing a 2 cm diameter circular staining area on the upper slide face using a hydrophobic pen (Fisher Scientific ...
-
bioRxiv - Neuroscience 2021Quote: ... An EVOS FL microscope (Invitrogen) was used to pick colonies for individual clones ...
-
bioRxiv - Microbiology 2022Quote: ... or an F20 microscope (ThermoFisher), both operating at 120 kV.
-
bioRxiv - Bioengineering 2023Quote: ... Fluorescent microscope (EVOS, Life technologies) was used to record videos in the CL- 3 facility.
-
bioRxiv - Biochemistry 2024Quote: ... and microscope slides (Fisher Scientific) passivated with mPEG (Laysan Bio ...
-
bioRxiv - Physiology 2019Quote: ... in combination with measurements of pH by handheld probe (Mettler Toledo pH probe; resolution: 1 mV, 0.01 pH; accuracy: ± 1 mV, ± 0.01 pH; Thermo Scientific Orion Star A series A325), salinity (Orion 013010MD Conductivity Cell ...
-
bioRxiv - Neuroscience 2019Quote: ... A measured PSF was generated by imaging 200 nm diameter fluorescent Tetraspeck beads (a sub-resolution particle in this imaging system) (Life Technologies, Waltham, MA, USA) mounted in 97% TDE and inputting the obtained images into the Huygens software’s PSF distiller application ...
-
bioRxiv - Cancer Biology 2020Quote: ... MS and data-dependent acquisition (MS/MS) analyses were performed on a high resolution Q-Exactive HF hybrid quadrupole-Orbitrap mass spectrometer (Thermo Fisher Scientific, Bremen, Germany) equipped with a Vanquish UHPLC binary system and autosampler (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2022Quote: ... The LC eluent (with a total flow rate of 300 µl/min) was introduced into the ESI source of a high resolution TripleTOF5600 mass spectrometer (Applied Biosystems, Foster City, CA). Instrumental settings for negative ion ESI and MS/MS analysis of lipid species were as follows ...
-
bioRxiv - Molecular Biology 2020Quote: ... mass spectrometry (MS) on an Agilent 1200 HPLC coupled to a Thermo Fisher Exactive Plus Orbitrap high resolution mass spectrometer (ThermoFisher Scientific, Waltham, MA, USA). HPLC and MS conditions are described in detail in [38] and [80] ...
-
bioRxiv - Microbiology 2022Quote: LC-MS and LC-MS/MS analyses were performed on a high-resolution Q-Exactive HF hybrid quadrupole-Orbitrap mass spectrometer (Thermo Fisher Scientific, Bremen, Germany) equipped with a Vanquish UHPLC binary system and autosampler (Thermo Fisher Scientific ...
-
bioRxiv - Synthetic Biology 2019Quote: ... coupled to a UV/Vis diode array detector (DAD) and a high-resolution mass spectrometer (HRMS) Orbitrap Fusion mass spectrometer (ThermoFisher Scientific, Waltham, MA, USA). UV-Vis detection was done using a DAD-3000 in the range 200 – 700 nm ...
-
bioRxiv - Cancer Biology 2019Quote: Global metabolomics was performed by ultra-high performance liquid chromatography coupled with high-resolution mass spectrometry (UHPLC-HRMS) on a Thermo Q Exactive with Dionex UHPLC (Thermo Fisher Scientific, Waltham, MA). To 50 μL of urine ...
-
bioRxiv - Physiology 2020Quote: ... by handheld probe (Mettler Toledo pH probe; resolution: 1 mV, 0.01 pH; accuracy: ± 1 mV, ± 0.01 pH; Thermo Scientific Orion Star A series A325), salinity (Orion 013010MD Conductivity Cell ...
-
bioRxiv - Plant Biology 2022Quote: ... MS spectra were acquired from 1-19 min by ThermoScientific Q Exactive in MS mode (resolution 25000, max. injection time 100 ms, automatic gain control value 1E6; Thermo Fisher Scientific, Waltham, USA;) in the scan range 100-1500 m/z ...
-
bioRxiv - Plant Biology 2023Quote: The exact masses of the compounds were determined using an Orbitrap Exactive high-resolution mass spectrometer with high mass determination accuracy coupled to a Dionex Ultimate 3000 UHPLC chromatograph (Thermo-Fisher Scientific, Waltham, MA, USA). The chromatographic conditions and column were identical to those previously described for unit resolution LCMS ...