Labshake search
Citations for Beckman :
151 - 200 of 351 citations for TRAILR 2 TNFRSF10B Human HEK 293 His since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Physiology 2019Quote: ... plasma samples were deproteinized with ZnSO4 and Ba(OH)2 and counted using a Liquid Scintillation Counter (Beckman Coulter LS6500 Multi-purpose Scintillation Counter) ...
-
bioRxiv - Cell Biology 2020Quote: ... the cleared supernatant was ultracentrifuged at 47,000 g for 2 hours at 4 °C using the JA25.50 rotor (Beckman). The virus was resuspended overnight in 180 μL D10 medium at 4 °C ...
-
bioRxiv - Microbiology 2019Quote: ... and adding this to 3 ml sterile inoculum water (Beckman Coulter, Inc. Brea, CA, cat no B1015-2) and 840 μl phenol red solution ...
-
bioRxiv - Cell Biology 2021Quote: ... 4 °C for 2 h in an Optima L-100XP ultracentrifuge (with SW 55 Ti rotor, Beckman Coulter). Fractionation was done manually by collecting every 200 μl volume from the top till the bottom of each centrifuge tube ...
-
bioRxiv - Cell Biology 2022Quote: ... Lentiviral particles were then concentrated by centrifugation for 2 hours at 20,000 rcf (Beckman Coulter, Optima L-100K) in round bottom polypropylene tubes (Beckman Coulter ...
-
bioRxiv - Molecular Biology 2023Quote: ... Digested extracts were then loaded on 1 M sucrose cushions 116 and centrifuged at 70,000 rpm for 2 hours at 4°C in a TLA100.4 rotor (Beckman). Ribosome pellets were resuspended in 300 µl of TRIzol reagent (Invitrogen) ...
-
bioRxiv - Microbiology 2023Quote: ... The filtrate was subjected to ultracentrifugation at 200,000xg for 2 h (Optima L-100 XP ultracentrifuge; Beckman Coulter). Supernatants were discarded ...
-
bioRxiv - Immunology 2023Quote: ... CD27 and BA.1 or BA.2 were sorted using a MoFlo Astrios EQ Cell Sorter (Beckman Coulter). FACS data were collected by Summit 6.0 (Beckman Coulter ...
-
bioRxiv - Microbiology 2024Quote: ... (The filtrate was subjected to ultracentrifugation at 100,000g for 2 h (Optima L-90 K ultracentrifuge; Beckman Coulter). The supernatant was discarded and the pellet was washed with sterile PBS and filtered through a sterile 0.2 μm-pore polyvinylidene difluoride (PVDF ...
-
bioRxiv - Neuroscience 2021Quote: ... 2 mL of 20% (w/v) sucrose in DPBS (-Ca, -Mg) is prepared in ultracentrifuge tubes (Beckman Coulter, 344058) to which the divided EnvA- pseudotyped viral media is added before pelleting (20,000 RPM for 2 hours at 4°C) ...
-
bioRxiv - Cell Biology 2019Quote: ... Sucrose gradients were subjected to ultracentrifugation (SW41 Ti 11E1698 rotor; Beckman at 260,000xg for 2 h at 4□°C) and fractionated by displacement using 60% sucrose/0.01% bromophenol blue on an ISCO Foxy fraction collector (35 s for each fraction ...
-
bioRxiv - Cell Biology 2020Quote: ... Lysates were loaded on the top of the gradient and centrifuged at 260,000 × g and 4 °C for 2 h using SW 41 rotor (Beckman). Collection of polysomal fractions were done using Piston Gradient Fractionator (BioComp) ...
-
Human Sex Matters: Y-linked lysine demethylase 5D drives accelerated male osteogenic differentiationbioRxiv - Cell Biology 2021Quote: ... Virus was transferred into conical tubes and spin at 20000rpm for 2 hours at 4°C in (Beckman TST2838) swinging bucket rotor ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 mM DTT) by being centrifuged at 73000 rpm for 45 minutes at 4°C (Beckman Coulter TL120.2 rotor). The mitoribosomal pellet was subsequently resuspended in ribosome resuspension buffer (25 mM HEPES-KOH pH = 7.5 ...
-
bioRxiv - Biochemistry 2020Quote: ... The functional complex was recovered as a jelly-like pellet by centrifugation at 60,000 rpm at 25°C for 2 h in an ultracentrifuge (128,000 g in a TLA 120.2 Beckman rotor) and packed into a 1.9 mm rotor ...
-
bioRxiv - Microbiology 2020Quote: ... and separated in potassium tartrate-glycerol gradient 10–35% for 2 hrs at 175,000 ×g (Beckman SW41 Ti rotor). Purified viral particles were suspended in 10 µg/ml BSA solution or 10 µg/ml CbAE-1 solution and incubated for 1 hr at room temperature ...
-
bioRxiv - Neuroscience 2022Quote: ... and centrifuged at 24,000 rpm for 2 h at 4°C using a SW-Ti32 swinging bucket (Beckman Coulter). The upper layer was discarded ...
-
bioRxiv - Cell Biology 2019Quote: ... MT seeds were diluted in BRB80 containing 2 μM taxol and centrifuged at 100,000 g (Optima TL100; Beckman Coulter) for 15 min ...
-
bioRxiv - Cell Biology 2021Quote: ... The supernatant was cleared again by 2 rounds of ultracentrifugation at 100,000 rpm (358,400 x g; Beckman TLA-120.2) for 10 minutes at 0°C ...
-
bioRxiv - Cell Biology 2021Quote: ... Pellets were resuspended in 0.9% NaCl and spun at 110,000 × g for 2 hours at 4°C in an XPN-80 ultracentrifuge equipped with a Type 50.4 Ti rotor (Beckman Coulter ...
-
bioRxiv - Microbiology 2021Quote: ... The VLPs were concentrated by ultracentrifugation for 2 h at 31,000 rpm at 4 °C (Beckman SW-31Ti rotor), and then resuspended in 500 μL of Ex-Cell 405 medium ...
-
bioRxiv - Molecular Biology 2021Quote: ... and the tube was centrifuged for 2 hours at 190,000 x g in a swing-out rotor (SW40 Ti; Beckman Coulter ...
-
bioRxiv - Microbiology 2021Quote: ... and either aliquoted or concentrated by ultracentrifugation using 20% (w/v) sucrose cushions for 2 hours at 25,000 rpm in an SW41 rotor (Beckman).
-
bioRxiv - Cell Biology 2022Quote: ... milk was prevented from cooling down and was processed within 20 minutes after collection by 2 rounds of centrifugation at 3,000xg for 10 minutes at 23°C (Beckman Coulter Allegra X-12R ...
-
bioRxiv - Microbiology 2022Quote: ... The pellet was resuspended in 2 ml (per fraction) of the supernatant and ultracentrifuged (Optima MAX-TL, Beckman Coulter) at 12,000 rpm (TLA55 rotor ...
-
bioRxiv - Molecular Biology 2023Quote: ... The gradients were centrifuged at 38,300 rpm for 2 hours and 45 min at 4 °C in a SW-40Ti (Beckman) rotor using an Optima XE-100 Ultracentrifuge (Beckman) ...
-
bioRxiv - Molecular Biology 2023Quote: ... The gradients were centrifuged at 38,300 rpm for 2 hours and 45 min at 4 °C in a SW-40Ti (Beckman) rotor using an Optima XE-100 Ultracentrifuge (Beckman) ...
-
bioRxiv - Plant Biology 2023Quote: ... Extract was then centrifuged at 40 000 rpm for 2 hours at 4°C using the 50Ti rotor (Beckman). A protocole previsouly used in the laboratory and described in Maclot et al ...
-
bioRxiv - Microbiology 2023Quote: ... The filtrate was subjected to ultracentrifugation at 200,000 xg for 2 h (Optima L-100 XP ultracentrifuge; Beckman Coulter). Supernatants were discarded ...
-
bioRxiv - Cancer Biology 2023Quote: ... RNA clean-up was performed by incubating RNA solution in 2 volumes of AMPure XP Beads (Beckman Coulter, A63881) for 2 minutes at room temperature ...
-
bioRxiv - Molecular Biology 2023Quote: ... 1-1.5 μg of total protein was loaded onto a 10% to 50% sucrose gradient and centrifuged at 36,000 rpm for 2 hours at 4°C using an SW41 rotor (Beckman). Polysome profiles were visualized ...
-
bioRxiv - Microbiology 2023Quote: ... 500 μ g of the lysate was loaded on the top of 15–50% sucrose gradient containing 100μ g/ml cycloheximide and the gradients were centrifuged at 36,000 rpm for 2 h at 4°C in SW41 rotor (Beckman). Density Gradient Fractionation System (ISCO ...
-
bioRxiv - Plant Biology 2023Quote: ... The supernatant from this step was decanted into the new tubes and centrifuged at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Beckman Coulter ...
-
bioRxiv - Microbiology 2023Quote: ... The samples were centrifugated at 70000 rpm for 2 h at 4°C in an Optima TLX Ultracentrifuge (Beckman Coulter ...
-
bioRxiv - Genetics 2023Quote: ... Fifteen A260 units of WCEs were layered on a pre-chilled 10-50% sucrose gradient and centrifuged at 40,000 rpm for 2 h at 4°C in a SW41Ti rotor (Beckman). Gradient fractions were continuously scanned at A260 using the BioComp Gradient Station and polysome to monosome (P/M ...
-
bioRxiv - Cancer Biology 2023Quote: ... the obtained supernatant was filtered through a 0.22 μm filter before ultracentrifugation at 150,000 g for 2 h at 4 °C (Beckman Coulter). The nsEV-containing pellet was resuspended in phosphate buffer saline (PBS).
-
bioRxiv - Neuroscience 2023Quote: ... Samples were then centrifuged at 82,600×g at 4°C for 2 h (Beckman ultracentrifuge optima L-100 XP). After the first ultracentrifugation ...
-
bioRxiv - Cell Biology 2024Quote: ... samples were ultracentrifuged at 160,000 xg for 2 h at 4 °C in ultracentrifuge tubes (Beckman Coulter Cat #328874). The resulting pellet contained the insoluble AMB-1 cell fraction and the supernatant contained the soluble fraction ...
-
bioRxiv - Neuroscience 2023Quote: ... The tubes were centrifuged at 100,000 × g for 2 hours using a SW 55Ti swinging-bucket rotor (Beckman Coulter).
-
bioRxiv - Cell Biology 2024Quote: ... The supernatant was then subjected to ultracentrifugation at 100,000 x g for 2 h at 4 °C to sediment small EVs (Optima L-80K ultracentrifuge, Beckman Coulter ...
-
bioRxiv - Cancer Biology 2024Quote: ... 100 μg/mL cycloheximide) for 2 h at 40,000 g at 4 °C using an SW41 rotor (Beckman Coulter). Gradients were fractionated using Teledyne Isco Tris Peristaltic Pump and fractions were collected and pooled according to the UV trace ...
-
bioRxiv - Microbiology 2020Quote: ... Excess dye was removed by ultracentrifugation of the virus through a 10% sucrose cushion for 2 h at 107,000 × g and 4°C using an SW41 rotor (Beckman Coulter). Labeled virus pellets were resuspended at a viral protein concentration of 1 mg/ml ...
-
bioRxiv - Genomics 2020Quote: ... RAD library quality was inspected on a 2% agarose gel before undergoing a final AMPure XP (Beckman Coulter, Indianapolis, IN) purification and quantification on a Qubit 2.0 Fluorometer (ThermoFisher Scientific ...
-
bioRxiv - Genomics 2020Quote: ... The crude nuclei were stained with 4,6-diamidino-2-phenylindole and loaded into a flow cytometer (Beckman Coulter MoFlo XDP). Nuclei were purified by flow sorting and washed in accordance with (70) ...
-
bioRxiv - Molecular Biology 2019Quote: ... for 2 h at 4°C and then further purified using CsCl equilibrium gradient ultracentrifugation at 35,000 rpm (Beckman SW56) for 18 h at 4°C ...
-
bioRxiv - Microbiology 2019Quote: ... Sucrose gradient ultracentrifugation was performed for 2 hours and 45 minutes at 35,000 rpm in a SW 41 Ti rotor (Beckman-Coulter) at 4°C ...
-
bioRxiv - Neuroscience 2019Quote: ... with 2 ml of 20% sucrose in dPBS cushion and ultracentrifugated at 20,000 RPM (Beckman Coulter SW 32 Ti rotor) at 4°C for 2 hours ...
-
bioRxiv - Molecular Biology 2020Quote: ... 100 ug/ml cycloheximide) and macromolecular complexes were separated by velocity gradient ultracentrifugation (SW41Ti – Beckman, 39,000 rpm, 2 hr, 4oC). Fractions were collected using Biocomp Gradient Station and pooled to obtain separate monosomal and polysomal fractions ...
-
bioRxiv - Biophysics 2021Quote: ... The unbound cyt c was separated from liposome-bound cyt c by ultracentrifugation at 435,000 g for 2 hours at 4 °C in an Optima TLX ultracentrifuge with a TLA-100 rotor (Beckman Coulter). Immediately after the ultracentrifugation ...
-
bioRxiv - Cell Biology 2021Quote: ... Collected FT were then subjected to ultracentrifugation for 2 hours at 200 000g using the TLA 45 rotor (Beckman Coulter) and resuspended in 20μL of Laemmli 1X (BioRad) ...