Labshake search
Citations for Beckman :
51 - 100 of 885 citations for Pregnanediol 3 Glucuronide PDG ELISA Kit 5 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Systems Biology 2020Quote: ... and 1 mL of 5% (w/v) iodixanol solutions on top of each other in a 5 mL open top polyallomer tube (Beckman Coulter). Crude exosomes were resuspended in 200 µL PBS and overlaid on top of the gradient ...
-
bioRxiv - Biophysics 2022Quote: ... Ribosomes were isolated by ultracentrifugation for 3 hours at 50,000 rpm (Beckman-Coulter Optima-90 ...
-
bioRxiv - Genomics 2019Quote: DNA fragments (3~8 kb) were purified with Agencourt AmpureXP beads (Beckman Coulter ...
-
bioRxiv - Immunology 2021Quote: ... Samples were measured on a Gallios (10 colors, 3 lasers, Beckman Coulter) flow cytometer using FACS Kaluza software v2.1.1 (Beckman Coulter) ...
-
bioRxiv - Cell Biology 2022Quote: ... and cell-size distribution measurements with a Coulter Counter (Beckman Multisizer 3) were conducted as described previously (42) ...
-
bioRxiv - Physiology 2023Quote: ... and monitored twice daily using an electronic particle counter (Multisizer 3, Beckman Coulter ...
-
bioRxiv - Cancer Biology 2023Quote: ... Cell counts were determined using a Multisizer 3 Coulter Counter (Beckman Coulter) with a diameter setting of 10-30 μm ...
-
bioRxiv - Physiology 2024Quote: ... and particle diameter measured using a Multisizer 3 Coulter Counter (Beckman Coulter). A 100 µm aperture was used for all experiments ...
-
bioRxiv - Cell Biology 2023Quote: ... followed by cell counting using a multisizer 3 coulter counter (Beckman Coulter), according to the manufacturer’s instructions41 ...
-
bioRxiv - Cell Biology 2022Quote: ... we used a CytoFLEX 5 flow cytometer (Beckman Coulter) and the CytExpert version 2.3 software ...
-
bioRxiv - Neuroscience 2022Quote: ... anti-CD90 (IM1839U / Beckman Coulter / F15-42-1-5), anti-CD146 (A07483 / Beckman Coulter / TEA1-34) ...
-
bioRxiv - Immunology 2023Quote: ... KIR2DL1/S1 (Beckman Coulter, clone EB6B: PE-Cy5-5) was performed at room temperature for 30 minutes in PBS (w/o Ca or Mg ...
-
bioRxiv - Systems Biology 2019Quote: ... a combination of plate-bound anti-CD3 (Beckman Coulter REF # IM-1304) and soluble anti-CD28 (Beckman coulter REF # IM1376 ...
-
bioRxiv - Cancer Biology 2020Quote: ... All processing was done in 96 well plate formats using robotics (Beckman FXp ...
-
bioRxiv - Genetics 2020Quote: ... Total absorbance at 500 nm was measured in a plate reader (Beckman) and subtracted from a blank before determining the amount of triglyceride using the reference standard curve ...
-
bioRxiv - Biochemistry 2019Quote: ... Plates were centrifuged at 2000 rpm (Allegra X-15R - Beckman Coulter, Inc.) for 2 min followed by 2 additional 10% TCA washes and one ethanol wash followed by centrifugation ...
-
bioRxiv - Microbiology 2022Quote: ... Plate was read immediately using a DTX 880 multimode detector (Beckman Coulter) with an integration time of 1 second.
-
bioRxiv - Cancer Biology 2022Quote: ... into the destination plate by an Echo 550 acoustic liquid dispenser (Beckman Coulter Life Sciences ...
-
bioRxiv - Immunology 2023Quote: ... The plates were analyzed by using a Cytoflex flow cytometer (Beckman Coulter). The data acquired from the flow cytometer experiments described above were processed on Flowjo software for gating strategy ...
-
bioRxiv - Immunology 2023Quote: ... The plates were analyzed by using a Cytoflex flow cytometer (Beckman Coulter). The data acquired from the flow cytometer experiments described above were processed on Flowjo software for gating strategy ...
-
bioRxiv - Cell Biology 2024Quote: ... multiwell plates were processed either manually or robotically (Beckman Coulter Biomek i5). In practice ...
-
bioRxiv - Neuroscience 2023Quote: ... 5 ml of complete Neurobasal medium were added and centrifuged for 5 min at 335 x g (Beckman Coulter Allegra X-12R centrifuge). The complete Neurobasal medium consisted of ...
-
bioRxiv - Cell Biology 2021Quote: ... final cell counts were measured using a Multisizer 3 Coulter Counter (Beckman Coulter). The following formula was used to calculate proliferation rate:
-
bioRxiv - Cell Biology 2020Quote: ... cells were washed 3 times and analyzed with MoFlo (Beckman, Brea, CA, USA) and associated software ...
-
bioRxiv - Cell Biology 2020Quote: Size of HSCs was determined using a Multisizer-3 Coulter Counter (Beckman Coulter) or microscopy ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3 (SAN4024, Sanplatec, Osaka, Japan) in a 10 ml tube (361707, Beckman Coulter). The 2K fraction was placed on the top or bottom of the media after dissolving the pellet in 500 µl of 8% or 48% iodixanol in 0.02 M HEPES ...
-
bioRxiv - Microbiology 2023Quote: ... cells were counted with an electronic particle counter (Multisizer 3 counter; Beckman Coulter) and 250 mL of SM ...
-
bioRxiv - Immunology 2024Quote: ... and then ultracentrifuged for 3 hours with a SW32 Ti rotor (Beckman Coulter) at 100,000 x g at 4°C ...
-
bioRxiv - Cell Biology 2021Quote: ... for 5 minutes at 4°C with TLA100 rotor (Beckman). 100 µg cell lysate was brought to a final volume of 250 µl BRB80 supplemented with 1 mM GTP ...
-
bioRxiv - Molecular Biology 2023Quote: ... 5 mM MgCl2) and spun in an SW41Ti rotor (Beckman) for 20 hours at 30,900 rpm ...
-
bioRxiv - Microbiology 2019Quote: ... The luminescence was measured using a DTX-800 multimode plate reader (Beckman Coulter). Standard curves were generated using serial dilutions of standard GSH (provided by the kit ...
-
bioRxiv - Microbiology 2020Quote: ... Luciferase activity was measured on a DTX-800 multimode plate reader (Beckman Coulter) using Luciferase Assay Reagent (Promega E4550) ...
-
bioRxiv - Cell Biology 2022Quote: ... PCR plates were loaded using the Biomek FX liquid handling robot (Beckman Coulter) and reactions [10 ng cDNA ...
-
bioRxiv - Biochemistry 2022Quote: ... Fluorescence intensity (FI) was measured using a fluorescence multi-well plate reader (Beckman Coulter AD340C ...
-
bioRxiv - Cell Biology 2021Quote: ... equipped with 3 lasers (405 nm, 488 nm, 633 nm, Beckman Coulter, Milan, Italy) and data were analysed with Kaluza Analysis Software v ...
-
bioRxiv - Neuroscience 2022Quote: ... Each stained sample was analyzed on a 3-laser Navios flow cytometer (Beckman-Coulter), based on a protocol standardized with Megamix-Plus FSC beads (BioCytex ...
-
bioRxiv - Developmental Biology 2023Quote: ... and ultracentrifuged at 50,000 x g for 3 hours in a SW41Ti rotor (Beckman). 12 fractions of 1 ml each were manually separated ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... using a special magnetic stand and plate according to the protocols described by Beckman coulter ...
-
bioRxiv - Plant Biology 2021Quote: ... 384-well plates were prepared using Beckman Biomek NXR Liquid Handling Workstation (Beckman, USA), with 2 µL lysis buffer (0.1% Triton X-100 ...
-
bioRxiv - Molecular Biology 2019Quote: ... GFP-positive cell per well in 96-well plates using a MoFlo (Beckman Coulter) or a Synergy (Sony ...
-
bioRxiv - Biochemistry 2020Quote: ... Reaction mixes were then transferred to Greiner plate using a Biomek I5 automate (Beckman). Picogreen® fluorescent reagent was diluted to 1/800° in TE buffer according to the data manufacturer and 60 µl of reagent were distributed into each well of the Greiner plate ...
-
bioRxiv - Biochemistry 2020Quote: ... Reaction mixes were transferred to a Greiner plate using a Biomek I5 Automate (Beckman). Picogreen fluorescent reagent was diluted to 1/800 in TE buffer according to manufacturer’s data ...
-
bioRxiv - Cancer Biology 2019Quote: Plates were thawed and RNA was purified using 2.2X RNAclean SPRI beads (Beckman Coulter) without final elution (Shalek et al. ...
-
bioRxiv - Immunology 2021Quote: ... The 10 cDNA plates were cleaned-up using AMPure XP beads (Beckman Coulter #A63881), deep 96 well plates (Abgene #AB-0765 ...
-
bioRxiv - Genomics 2023Quote: ... Luminescence and absorbance were measured in a multimode plate reader (Beckman Coulter, DTX-880). Cell number was also estimated using the CellTox Green Cytotoxicity Assay (Promega ...
-
bioRxiv - Molecular Biology 2023Quote: ... Luminescence and absorbance were measured in a multimode plate reader (Beckman Coulter, DTX-880).
-
bioRxiv - Immunology 2021Quote: ... for 5 minutes (TEMP) and labeled with Viakrome 808 (Beckman Coulter) and fluorochrome-labeled antibodies against CD4 ...
-
bioRxiv - Immunology 2022Quote: ... anti-NKG2A-APC (clone Z199; 5 μL; cat. # A60797) from Beckman Coulter ...
-
bioRxiv - Cancer Biology 2022Quote: ... 5×10^6 cells counted by Multisizer 4e Coulter Counter (Beckman) were plated on a 60 mm plate and serum starved before analysis unless otherwise indicated ...
-
bioRxiv - Cell Biology 2021Quote: ... About 9 ml interface that came from 3×SW28 tubes (25×89 mm, Beckman Coulter) was loaded in a SW41 tube (14×89 mm ...