1 - 50 of 433 citations for NGS ChIP Seq kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2019Quote: ... starting with 10 ng of the sheared ChIP DNA and including a double-AMPure bead (Beckman Coulter) size selection ...
-
bioRxiv - Genomics 2019Quote: ... and 3′ RNA-seq libraries were prepared from 500 ng total RNA in 96-well plates on an NXp liquid handler (Beckman Coulter) using QuantSeq FWD kits (Lexogen ...
-
bioRxiv - Plant Biology 2021Quote: ... and 3′ RNA-seq libraries were prepared robotically from 500 ng total RNA in 96-well plates on an NXp liquid handler (Beckman Coulter) using QuantSeq FWD kits (Lexogen ...
-
bioRxiv - Genomics 2021Quote: ... The ATAC-seq and mRNA-seq libraries were purified with AMPure XP beads (Beckman Coulter) and then quantified with Qubit dsDNA HS Assay Kit (Invitrogen).The libraries were pooled and sequenced on Illumina NextSeq550 with paired-end 75-bp reads.
-
bioRxiv - Cancer Biology 2021Quote: ... ChIP DNA was purified using SPRI beads (Beckman Coulter) and quantified using the Qubit 2000 (Invitrogen ...
-
bioRxiv - Cancer Biology 2021Quote: ... ChIP DNA was purified using SPRI beads (Beckman Coulter) and quantified using the Qubit 2000 (Invitrogen ...
-
bioRxiv - Cancer Biology 2020Quote: ... ChIP DNA was collected with Ampure XP beads (Beckman) and quantified using Qubit High Sensitivity DNA kit (Life Technologies) ...
-
bioRxiv - Genomics 2024Quote: ... Surplus PCR primers were further removed by purification using AMPure XP beads (SPRIselect beads for TT-seq and Frac-seq) (Beckman-Coulter, Villepinte, France) and the final cDNA libraries were checked for quality and quantified using capillary electrophoresis ...
-
bioRxiv - Microbiology 2022Quote: ... ATAC-seq libraries were purified using AMPure SPRI beads (Beckman Coulter) and then sequenced on a NextSeq 2000 (Illumina ...
-
bioRxiv - Genomics 2021Quote: ChIP samples were purified using Agencourt AMPure XP beads (Beckman Coulter) and quantified with the Qubit (Invitrogen) ...
-
bioRxiv - Cell Biology 2023Quote: ... ChIP samples were purified with Agencourt AMPure XP beads (Beckman Coulter) and their concentration was quantified with Qubit (Invitrogen) ...
-
bioRxiv - Genomics 2021Quote: ... RNA-seq libraries were purified with AMPure XP beads (A63880, Beckman Coulter) to select 150∼200 bp cDNA fragments ...
-
bioRxiv - Genomics 2021Quote: ... The ATAC-seq libraries were purified with AMPure XP beads (Beckman Coulter) and quantified with Qubit dsDNA HS Assay Kit (Invitrogen) ...
-
bioRxiv - Genomics 2022Quote: ... ATAC-seq libraries generated were purified using AMPure XP beads (Beckman Coulter) and quantified using Qubit DNA high sensitivity assay in combination with Tapestation D1000 prior to sequencing.
-
bioRxiv - Cell Biology 2020Quote: ... ChIP DNA was purified using Agencourt AMPure XP beads (A63881, Beckman Coulter) and DNA amounts determined by Qubit® 2.0 fluorometer (Invitrogen) ...
-
bioRxiv - Immunology 2021Quote: ... Amplified CITE-seq libraries are purified using AMPure XP (Beckman Coulter, Indianapolis, IN) beads and quantified by Qubit dsDNA assay (ThermoFisher ...
-
Naked Mole-Rat Hematopoietic Stem and Progenitors are Highly Quiescent with an Inherent Myeloid BiasbioRxiv - Cell Biology 2021Quote: ... Amplified CITE-seq libraries are purified using AMPure XP (Beckman Coulter, Indianapolis, IN) beads and quantified by Qubit dsDNA assay (ThermoFisher ...
-
bioRxiv - Plant Biology 2021Quote: ... All amplified ATAC-seq libraries were purified using AMPure XP beads (Beckman Coulter), quantified by a Qubit Fluorometer and analyzed on an Agilent 2100 Bioanalyzer prior to pooling and subsequently sequenced using Illumina NovaSeq.
-
bioRxiv - Cancer Biology 2020Quote: ... Live CD45+ cells were isolated for scRNA-seq using an Astrios (Beckman Coulter) sorter and resuspended in PBS with 0.04% BSA at a concentration of 1000 cells/µL for single-cell RNA sequencing.
-
bioRxiv - Cancer Biology 2024Quote: ... Live CD45+ cells were isolated for scRNA-seq using an Astrios (Beckman Coulter) sorter and resuspended in PBS with 0.04% BSA at a concentration of 1000 cells/µL for single-cell RNA sequencing.
-
bioRxiv - Neuroscience 2024Quote: ... Cell sorting for RNA-seq was performed on a MoFlo Astrios (Beckman Coulter).
-
bioRxiv - Immunology 2021Quote: ... Amplified RNA-seq libraries were purified using AMPure XP System (Beckman Coulter, Brea, CA). Quality of libraries were determined via Agilent 2200 TapeStation using High Sensitivity D1000 tape and quantified using Kappa SYBR®Fast qPCR kit (KAPA Biosystems ...
-
bioRxiv - Immunology 2023Quote: ... ATAC-seq libraries were cleaned up using 90μl of AMPure XP beads (Beckman Coulter) and two 80% Ethanol washes whilst being placed on a magnetic plate stand ...
-
bioRxiv - Immunology 2023Quote: ... The ChIP DNA libraries were size selected using SPRIselect beads (Beckman Coulter, Cat.#B23317) and quantified using Agilent 2100 Bioanalyzer and Qubit (Invitrogen ...
-
bioRxiv - Biophysics 2024Quote: ... ChIP samples and corresponding inputs were purified by AMPure XP beads (Beckman Coulter A63880).
-
bioRxiv - Molecular Biology 2020Quote: ... PCR amplified RNA-seq libraries were size selected using AMPure XP beads (Beckman Coulter, A68831). RNA-seq libraries were subjected to 75 basepair single end sequencing on Illumina NextSeq500 sequencer.
-
bioRxiv - Cancer Biology 2023Quote: ... ChIP DNA was then amplified 12 cycles and purified using AMpure XP beads (Beckman, A63881) twice and then were submitted for150 bp paired-end sequencing on an Illumina novaseq 6000 platform (Novogene).
-
bioRxiv - Microbiology 2020Quote: ... The resulting cDNA was PCR-amplified to about 10-20 ng/μl using a high-fidelity DNA polymerase followed by purification using the Agencourt AMPure XP kit (Beckman Coulter). The cDNA samples were pooled with ratios according to the RNA concentrations of the input samples and a size range of 200-550 bp was eluted from a preparative agarose gel ...
-
bioRxiv - Cancer Biology 2022Quote: ... ATAC-seq libraries were purified by size selection using Ampure XP beads (Beckman Coulter, Brea, CA), and library quality assessed by fragment analyzer and qPCR for GAPDH and a genomic desert region ...
-
bioRxiv - Molecular Biology 2019Quote: The native ChIP DNA (fragments longer than 100bp) was isolated using 1x SPRI beads (Beckman Coulter) and set up in an overnight in vitro transcription reaction (HiScribe T7 Quick High Yield RNA Synthesis kit ...
-
bioRxiv - Molecular Biology 2020Quote: ... The resulting cDNA was PCR-amplified to about 10–20 ng/μl using a high-fidelity DNA polymerase and purified with the Agencourt AMPure XP Kit (Beckman Coulter Genomics). The cDNA samples were pooled based on the ratios according to the RNA concentrations of the input samples ...
-
bioRxiv - Molecular Biology 2022Quote: ... The resulting TGIRT-seq libraries were cleaned up by using 1.4 X AMPure XP beads (Beckman Coulter) and eluted in 25 µL double-distilled H2O ...
-
bioRxiv - Cancer Biology 2023Quote: RNA-seq samples preparation and sequencing: RNA was isolated using magnetic beads (RNAClean XP, Beckman Coulter, A63987) from 10 Drosophila larval brains per sample following the protocol described in (Janic et al. ...
-
bioRxiv - Genomics 2022Quote: ... The amplified RNA-seq library was purified by immobilization onto AMPure XP PCR purification system (Beckman Coulter, A63881). The library fragments originated from rRNA and mitochondrial rRNA were treated with ZapR v2 and R-Probes according to manufacturer’s protocol ...
-
bioRxiv - Genomics 2022Quote: ... RNA-seq libraries were purified using the Agencourt® AMPure® XP system (Beckman Coulter Genomics, Danvers, MA, USA) according to the manufacturer’s instructions for double size selection (0.75× followed by 1.0× ratio).
-
bioRxiv - Cell Biology 2024Quote: ... CD81-APC (Beckman Coulter, clone JS64, A87789; 0.6 ng/µl), H3-AF488 (Invitrogen ...
-
bioRxiv - Molecular Biology 2022Quote: ... or a 384-well plate containing 1x Takara lysis buffer (STORM-seq) using a MoFlo Astrios cell sorter running Summit v6.3 (Beckman Coulter). The Astrios was equipped with a 100 um nozzle at 25 psi ...
-
bioRxiv - Genomics 2021Quote: ... the amplified ATAC-seq library was subjected to double-sided size-selection using magnetic beads (AMPure XP, Beckman Coulter BC-A63880). Firstly ...
-
bioRxiv - Microbiology 2022Quote: ... 50 μL of the amplified ATAC-seq library was subjected to double-sided size selection using magnetic beads (AMPure XP, Beckman Coulter). DNA bound to the beads was washed twice with 80% ethanol and then eluted in 20 μL H2O ...
-
bioRxiv - Cancer Biology 2023Quote: ... MULTI-seq barcode fragments were separated from endogenous cDNA fragments during the first round of size selection using SPRIselect beads (Beckman coulter). Next ...
-
bioRxiv - Immunology 2023Quote: ... and soluble anti-CD28 (500 ng/ml; Beckman Coulter, REF# IM1376) antibodies in presence of cytokines i.e. ...
-
bioRxiv - Physiology 2022Quote: ... the library preparation step followed the CEL-Seq 2 protocol85: the RT product was digested by ExoI and HinFI and purified using AMpure XP beads (Beckman Coulter™, USA). Then ...
-
bioRxiv - Microbiology 2021Quote: ... The final RNA-Seq library was obtained after 15 cycles of PCR amplification and purified using Agencourt AMPure XP beads (Beckman and Coulter, Beverly, MA, USA). The library size distribution was evaluated by running samples on the Agilent 2100 Bioanalyzer ...
-
bioRxiv - Genomics 2020Quote: ... 50 ng genomic DNA was purified using AgencourtAMPure XP Reagent (Beckman Coulter Inc, Brea, CA, USA) according to manufacturer’s protocol ...
-
bioRxiv - Cancer Biology 2020Quote: DNA preparation: 200 ng genomic DNA was purified using Agencourt AMPure XP Reagent (Beckman Coulter, Inc.) according to the manufacturer’s protocol ...
-
bioRxiv - Biochemistry 2021Quote: ... using 1-10 ng DNA and libraries were size selected with AMPure XP beads (Beckman Coulter). Illumina 50 bp single-end read sequencing was performed on a NextSeq 500 or NovaSeq 6000 ...
-
bioRxiv - Microbiology 2022Quote: ... Equal amounts of amplicons (240 ng) from each sample were pooled and AMPure XP (Beckman Coulter) beads were used to clean the sample library ...
-
bioRxiv - Microbiology 2023Quote: ... 100 ng of DNA from each sample was buffer exchanged via Ampure XP bead purification (Beckman Coulter Life Sciences product number A63881 ...
-
bioRxiv - Genomics 2021Quote: ... using an input of 50 ng gDNA and outputs were purified with AMpure XP beads (Beckman Coulter). WGS libraries were quality controlled with the high-sensitivity DNA kit on the Bioanalyzer (Agilent) ...
-
bioRxiv - Microbiology 2022Quote: ... 2 ng of each product were pooled for subsequent cleanup using the AmpureXP PCR cleanup protocol (Beckman). The pooled library was quantified by a picogreen assay and loaded onto an Illumina MiSeq Reagent Kit v3 (600-cycle ...