Labshake search
Citations for Beckman :
451 - 500 of 908 citations for Human V Set And Immunoglobulin Domain Containing Protein 2 VSIG2 CLIA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2023Quote: ... the obtained supernatant was filtered through a 0.22 μm filter before ultracentrifugation at 150,000 g for 2 h at 4 °C (Beckman Coulter). The nsEV-containing pellet was resuspended in phosphate buffer saline (PBS).
-
bioRxiv - Neuroscience 2023Quote: ... Samples were then centrifuged at 82,600×g at 4°C for 2 h (Beckman ultracentrifuge optima L-100 XP). After the first ultracentrifugation ...
-
bioRxiv - Cell Biology 2024Quote: ... samples were ultracentrifuged at 160,000 xg for 2 h at 4 °C in ultracentrifuge tubes (Beckman Coulter Cat #328874). The resulting pellet contained the insoluble AMB-1 cell fraction and the supernatant contained the soluble fraction ...
-
bioRxiv - Neuroscience 2023Quote: ... The tubes were centrifuged at 100,000 × g for 2 hours using a SW 55Ti swinging-bucket rotor (Beckman Coulter).
-
bioRxiv - Cell Biology 2024Quote: ... The supernatant was then subjected to ultracentrifugation at 100,000 x g for 2 h at 4 °C to sediment small EVs (Optima L-80K ultracentrifuge, Beckman Coulter ...
-
bioRxiv - Cancer Biology 2024Quote: ... 100 μg/mL cycloheximide) for 2 h at 40,000 g at 4 °C using an SW41 rotor (Beckman Coulter). Gradients were fractionated using Teledyne Isco Tris Peristaltic Pump and fractions were collected and pooled according to the UV trace ...
-
bioRxiv - Neuroscience 2022Quote: ... pooled and purified with Agencourt AMPure XP kit (Beckman Coulter). Purified PCR products were quantified using a Qubit dsDNA HS assay kit (Life Technologies ...
-
bioRxiv - Microbiology 2019Quote: ... and Agencourt® RNAClean® XP Kit (Beckman Coulter, USA). Measurement of RNA yield and quality was performed using Qubit® RNA HS assay kit (Thermo Fisher ...
-
bioRxiv - Microbiology 2020Quote: ... and Agencourt® RNAClean® XP Kit (Beckman Coulter, USA). Measurement of RNA yield and quality was performed using Qubit® RNA HS assay kit (Thermo Fisher ...
-
bioRxiv - Microbiology 2021Quote: DNA was extracted using the GenFind v2 kit (Beckman Coulter) and libraries prepared using the NexteraFlex kit (Illumina Inc. ...
-
bioRxiv - Microbiology 2022Quote: ... and the Agencourt RNAdvance Tissue Kit (Beckman Coulter, Krefeld, Germany). FFPE sections were loaded into a microTUBE-130 Screw-Cap (Covaris ...
-
bioRxiv - Cancer Biology 2022Quote: ... single-stained beads (VersaComp Antibody Capture Bead Kit; Beckman Coulter) and a single-stained cell-mix of all samples analyzed were used ...
-
bioRxiv - Bioengineering 2021Quote: ... were performed using the PerFix-nc Kit (Beckman Coulter #B31167), for 30 min at 4 °C in supplemented PBS containing 2 mM EDTA and 2% FBS ...
-
bioRxiv - Microbiology 2021Quote: RNA was extracted using the RNAdvance Tissue kit (Beckman Coulter) and the KingFisher Flex System (Thermo Fisher Scientific) ...
-
bioRxiv - Immunology 2022Quote: ... preamplification and purification with SPRIselect Reagent Kit (Beckman Coulter, B23318). Paired V(D)J sequence were enriched with 10X primers ...
-
bioRxiv - Microbiology 2023Quote: ... purified with the Agencourt AMPure XP kit (Beckman Coulter Genomics), and analyzed by capillary electrophoresis ...
-
bioRxiv - Molecular Biology 2023Quote: ... and cleaned using the Agencourt RNAClean XP Kit (Beckman-Coulter) according to manufacturer’s instructions ...
-
bioRxiv - Genetics 2023Quote: ... Samples were purified with the CleanSEQ kit (Beckman Coulter, A29151) following the Agencourt CleanSEQ Dye-Terminator Removal protocol ...
-
bioRxiv - Molecular Biology 2022Quote: ... were pre-clarified to remove aggregate proteins by spinning at 65,000 rpm for 30 min at 4°C in a TLA100 rotor (Beckman Coulter, Brea, CA) before incubating with F-actin ...
-
bioRxiv - Cell Biology 2019Quote: ... The obtained supernatant (containing membrane and cytosolic proteins) was then centrifuged at 180,000 × g for 90 min at 4°C using a TLA-55 rotor (Beckman Coulter, Brea, CA). The obtained pellet (containing intact membranes ...
-
bioRxiv - Microbiology 2020Quote: ... Excess dye was removed by ultracentrifugation of the virus through a 10% sucrose cushion for 2 h at 107,000 × g and 4°C using an SW41 rotor (Beckman Coulter). Labeled virus pellets were resuspended at a viral protein concentration of 1 mg/ml ...
-
bioRxiv - Genomics 2020Quote: ... RAD library quality was inspected on a 2% agarose gel before undergoing a final AMPure XP (Beckman Coulter, Indianapolis, IN) purification and quantification on a Qubit 2.0 Fluorometer (ThermoFisher Scientific ...
-
bioRxiv - Genomics 2020Quote: ... The crude nuclei were stained with 4,6-diamidino-2-phenylindole and loaded into a flow cytometer (Beckman Coulter MoFlo XDP). Nuclei were purified by flow sorting and washed in accordance with (70) ...
-
bioRxiv - Molecular Biology 2019Quote: ... for 2 h at 4°C and then further purified using CsCl equilibrium gradient ultracentrifugation at 35,000 rpm (Beckman SW56) for 18 h at 4°C ...
-
bioRxiv - Microbiology 2019Quote: ... Sucrose gradient ultracentrifugation was performed for 2 hours and 45 minutes at 35,000 rpm in a SW 41 Ti rotor (Beckman-Coulter) at 4°C ...
-
bioRxiv - Neuroscience 2019Quote: ... with 2 ml of 20% sucrose in dPBS cushion and ultracentrifugated at 20,000 RPM (Beckman Coulter SW 32 Ti rotor) at 4°C for 2 hours ...
-
bioRxiv - Molecular Biology 2020Quote: ... 100 ug/ml cycloheximide) and macromolecular complexes were separated by velocity gradient ultracentrifugation (SW41Ti – Beckman, 39,000 rpm, 2 hr, 4oC). Fractions were collected using Biocomp Gradient Station and pooled to obtain separate monosomal and polysomal fractions ...
-
bioRxiv - Biophysics 2021Quote: ... The unbound cyt c was separated from liposome-bound cyt c by ultracentrifugation at 435,000 g for 2 hours at 4 °C in an Optima TLX ultracentrifuge with a TLA-100 rotor (Beckman Coulter). Immediately after the ultracentrifugation ...
-
bioRxiv - Cell Biology 2021Quote: ... Collected FT were then subjected to ultracentrifugation for 2 hours at 200 000g using the TLA 45 rotor (Beckman Coulter) and resuspended in 20μL of Laemmli 1X (BioRad) ...
-
bioRxiv - Biochemistry 2021Quote: ... Equal parts of 30% and 10% iodixanol gradient solutions were layered on the mitochondrial fraction and then samples were centrifuged at 50,000 x g for 2 h (Beckman SW41TI). The mitochondrial layer was collected ...
-
bioRxiv - Cell Biology 2021Quote: Microtubules were sedimented onto poly-L-lysine coated coverslips by centrifuging through 20% glycerol BRB80 cushion at 4700 rpm for 2 h in S6096 rotor (Beckman). Coverslips were subsequently fixed with 20°C methanol ...
-
bioRxiv - Synthetic Biology 2021Quote: ... The collected supernatants were centrifuged at 300,000 x g for 2 hr with Optima MAX-XP ultracentrifuge with SW 55 Ti Swinging-Bucket Rotor (Beckman Coulter). The pellets consisting of the cell membrane fractions were resuspended into 10 mL of the same glycan containing media and incubated in the anaerobic chamber at 37°C for 16 hr ...
-
bioRxiv - Microbiology 2021Quote: ... Pool 1 and pool 2 amplicons were combined and purified with a 1:1 ratio of AMPureXP beads (Beckman Coulter) and eluted in 30 μL of sterile water ...
-
bioRxiv - Genomics 2021Quote: ... lentiviral supernatant was ultracentrifuged at 23,000 RPM at 4 °C for 2 hours in an SW 32 Ti swinging bucket rotor (Beckman Coulter). After centrifugation ...
-
bioRxiv - Cell Biology 2020Quote: ... The supernatant was then overlaid onto a 2 ml 60% iodixanol cushion and centrifuged at 100,000 × g (SW32 rotor, Beckman Coulter) for 18h ...
-
bioRxiv - Molecular Biology 2022Quote: ... Single-cell clones were then assessed for binding to His-tagged SARS-CoV-2 Spike using a Cytoflex S (Beckman) cell analyser ...
-
bioRxiv - Microbiology 2022Quote: Extracellular HSV-1 or HSV-2 particles were harvested by sedimentation at 12,000 rpm for 90 minutes at 4°C (Type 19 rotor, Beckman-Coulter) from the medium of BHK-21 cells (40 x 175 cm² flasks ...
-
bioRxiv - Cell Biology 2022Quote: ... and concentrated by 20% sucrose gradient ultracentrifugation in an Optima XPN-100 ultracentrifuge at 26,000 rpm at 4°C for 2 hours in a SW32 Ti swinging bucket rotor (Beckman-Coulter). Viral particles were resuspended in PBS and stored at −80°C.
-
bioRxiv - Developmental Biology 2020Quote: ... Virus-containing supernatant was collected for two consecutive days and concentrated by ultracentrifugation for 2 hours at 19,400 rpm using an Optima L-80 XP Ultracentrifuge (Beckman Coulter).
-
bioRxiv - Cancer Biology 2020Quote: ... samples were suspended in FACS buffer (PBS, 20 mM EDTA pH 8.0, 2% FCS) and acquired using a CyAn ADP9 flow cytometer (Beckman Coulter), FACS LSRII Fortessa or FACSymphony (both BD Biosciences) ...
-
bioRxiv - Microbiology 2021Quote: ... pspAX.2 and oligonucleotides were incubated for 48 h and GFP expression level was analyzed by CytoFLEX flow cytometer (Beckman).
-
bioRxiv - Microbiology 2021Quote: ... Concentrated supernatants were then subjected to ultracentrifugation at 160,000 x g for 2 hours at 4°C using a Beckman Ti 45 rotor (Beckman, Germany). Supernatants were completely removed and the pellet containing the crude MV fraction was resuspended in 400 μL of chilled PBS ...
-
bioRxiv - Neuroscience 2022Quote: ... The gradient was subjected to high-speed centrifugation at 100,000 x g for 2 h at 4° C using a SW41Ti rotor (Beckman Coulter). 12 fractions of 1ml each were collected from the top of the gradient ...
-
bioRxiv - Neuroscience 2022Quote: ... Lentiviral supernatant was collected 48 hours after transfection and centrifuged for 2 hours by ultracentrifugation at 25,000 RPM at 4°C (Beckman Coulter). Pellets were resuspended in DPBS and frozen in -80°C until used ...
-
bioRxiv - Neuroscience 2022Quote: ... new medium was added for another round of production and supernatant was filtered (0.45 μm filter) and centrifuged for 2 hours at 19400 rpm (SW28 Beckman rotor). The pellets were suspended in phosphate buffer saline (PBS) ...
-
bioRxiv - Microbiology 2022Quote: ... was added before ultracentrifugation at 20,000 × g for 2 hours at 10°C in an Optima L-90K Ultracentrifuge with the SW32Ti rotor (Beckman Coulter). Supernatants were carefully discarded by aspiration and the 6 phage pellets were resuspended with 0.1 ml of TM buffer (50 mM Tris-HCl ...
-
bioRxiv - Synthetic Biology 2021Quote: Reactions were assembled in a final volume of 2 μL using a Labcyte Echo® 550 (Beckman Coulter, Brea, CA) via a two-step strategy ...
-
bioRxiv - Neuroscience 2021Quote: ... The resulting homogenate was mixed with 6 mL sucrose (2 mol/L) and 2.5 mL CaCl2 (0.1 mmol/L) in an ultra-clear centrifuge tube (#344059, Beckman Coulter, USA). Then ...
-
bioRxiv - Molecular Biology 2021Quote: ... cell lysates were cleared by centrifugation at 4 °C for 5 minutes at 16000 x g and loaded onto ice-cold 15-50 % sucrose-CHX gradients and ultracentrifuged at 4 °C for 2 hours at 274 000 x g in a SW-41Ti rotor (Beckman). Gradients were fractionated and monitored at an absorbance of 254 nm with a fraction collector (BioComp Instruments ...
-
bioRxiv - Cancer Biology 2021Quote: ... Samples were ultracentrifugated at 100,000g for 2 hours using OPTIMA MAX XP ULTRACENTRIFUGE with MLA-130 fixed-angle rotor (Beckman-Coulter) and pellets were resuspended in 0.22 μm-filtered PBS ...