Labshake search
Citations for Beckman :
1 - 50 of 1615 citations for Cyclohexyl 2 3 4 5 trifluorophenyl ethyl ketone since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2021Quote: ... and centrifuged at 40,000 rpm (∼128,000 × g) for 3 h at 4°C using an MLS-5 rotor (Beckman Coulter). Aldolase (158 kDa ...
-
bioRxiv - Immunology 2021Quote: ... CD38 APC-AF700 (clone LS198-4-3; Beckman Coulter), CD19 APC-Cy7 (clone SJ25C1 ...
-
bioRxiv - Immunology 2023Quote: ... Bacteria cultures were collected and discarded by centrifugation for 60 min at 4,000-8,000 x g and the supernatants were subjected to high-speed centrifugation at 11,9000 x g for 2-3 h at 4°C (Beckman Coulter Optima Ultracentrifuge). The pellets containing the OMVs were washed with PBS ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 °C for 3 h (SW40 Ti rotor, Beckman-Coulter, Germany), the supernatant was discarded ...
-
bioRxiv - Immunology 2023Quote: ... AlexaFluor 700 anti-human CD38 (clone LS198-4-3, Beckman Coulter), APC-Cy7 anti-human CD19 (clone SJ25C1 ...
-
bioRxiv - Cell Biology 2021Quote: ... for 5 minutes at 4°C with TLA100 rotor (Beckman). 100 µg cell lysate was brought to a final volume of 250 µl BRB80 supplemented with 1 mM GTP ...
-
bioRxiv - Neuroscience 2021Quote: ... KG, Staufen, Germany) (position 6, 4 × 5-s bursts) and subsequently centrifuged at 48,000g at 4°C (Beckman Avanti J-251 Ultracentrifuge ...
-
bioRxiv - Bioengineering 2024Quote: ... for 2 hrs at 4°C in polypropylene tubes (Beckman Coulter). Concentrated Cas9-EDVs were resuspended in Opti-MEM (Gibco ...
-
bioRxiv - Cancer Biology 2020Quote: ... 3 and 5 and counted using a particle counter (Z1; Beckman Coulter, Inc.). Experiments were carried out in triplicate ...
-
bioRxiv - Cancer Biology 2024Quote: ... followed by centrifugation at 36,000 rpm for 3 hours at 4°C (Beckman Coulter). RNA was then extracted from the monosomes fraction using Trizol (Invitrogen ...
-
bioRxiv - Cell Biology 2021Quote: ... Beads were centrifugated at 1000 g for 5 min at 4°C (Beckman Coulter Microfuge 22R ...
-
bioRxiv - Genomics 2020Quote: ... and separated by ultracentrifugation at 4°C for 3 hours (35300 rpm, Beckman, SW41 rotor) through a 5-50% sucrose gradient (40 mM Tris-HCl pH 8.4 ...
-
bioRxiv - Biophysics 2023Quote: ... precipitated by ultracentrifugation (35,000 rpm for 3 h at 4 ° C, Beckman-Coulter L90K, USA), and then redissolved in TNE/5 buffer.
-
bioRxiv - Immunology 2024Quote: ... at 100,000 × g for 3 hours and at 4 °C (Type 45 Ti, Beckman Coulter) to concentrate the exosomes ...
-
bioRxiv - Cancer Biology 2024Quote: ... at 100,000 × g for 3 hours at 4°C (345776, Type 45 Ti, Beckman Coulter). Afterwards ...
-
bioRxiv - Neuroscience 2021Quote: ... 4 × 5-s bursts) and subsequently centrifuged at 48,000g at 4°C (Beckman Avanti J-251 Ultracentrifuge; Beckman Coulter, Fullerton, CA) for 30 min ...
-
bioRxiv - Biophysics 2020Quote: ... After centrifugation at 30,000 rpm (4 ° C for 3 h) in the SW45Ti rotor (Beckman Instruments), eight 1.5-ml fractions were collected from the top of a gradient ...
-
bioRxiv - Biochemistry 2020Quote: ... Gradients were resolved at 36,000 rpm for 3 hours at 4 °C in SW41 rotor (Beckman). Both separation and fractionation of gradients used a Biocomp Gradient Station (BioComp Instruments ...
-
bioRxiv - Biochemistry 2020Quote: ... subjected to centrifugation (36,000 rpm for 3 hours at 4 °C, SW-41Ti Beckman Coulter rotor) and analysed using Biocomp Gradient Station (BioComp Instruments ...
-
bioRxiv - Cell Biology 2022Quote: ... and the post-nuclear supernatant was loaded onto an 8-step discontinuous sucrose density gradient (HEPES-buffered 0.2–2 M sucrose) and centrifuged at 55,000 rpm for 2h at 4 °C using an MLS50 rotor (Beckman Coulter). Extracellular acidification rate (ECAR ...
-
bioRxiv - Neuroscience 2023Quote: ... The resulting supernatant was filtered with a membrane pore size of 0.2 μm (Whatman) and centrifuged at 120,000 × g for 4 h at 4 °C in polycarbonate bottle assemblies (Beckman coulter, 355603) in a 70.1 Ti fixed angle rotor (Beckman coulter ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 mM DTT) and centrifuged for 2 hours and 15 minutes at 39000 rpm at 4°C (Beckman Coulter TLS55 rotor). Fractions corresponding to the large mitochondrial subunit were collected and subjected to buffer exchange (25 mM HEPES-KOH pH = 7.5 ...
-
bioRxiv - Molecular Biology 2022Quote: ... The gradients were centrifuged at 35,000 rpm for 3 hours at 4°C (SW41 Ti rotor; Beckman) and subsequently fractionated using a Piston Gradient Fractionator (Biocomp instruments ...
-
bioRxiv - Biophysics 2023Quote: ... iVCL supernatant was centrifugated for 3 h at 25000 rpm and 4 °C (Beckman-Coulter L90K, USA). Precipitate was resuspended in the TNE buffer (0.1 M Tris-HCl ...
-
bioRxiv - Plant Biology 2023Quote: ... followed by ultracentrifugation at 4°C for 2 h (38000 rpm, Beckman, SW41 rotor) through a 20-60% sucrose gradient (40 mM Tris-HCl pH 8.4 ...
-
Rhes protein transits from neuron to neuron and facilitates mutant huntingtin spreading in the brainbioRxiv - Neuroscience 2021Quote: ... The gradient was spun for 3 h at 180,000 × g (average) at 4°C (SW41 Beckman ultra-centrifuge). After the spin the top of the gradient was removed and discarded ...
-
bioRxiv - Microbiology 2021Quote: ... The outer membrane vesicles (OMVs) were then isolated by ultracentrifugation (140 000xg, 4°C) for 3 hours (Beckman Coulter ...
-
bioRxiv - Molecular Biology 2022Quote: ... Gradients were ultracentrifuged at 28.000g for 3 h at 4°C in a SW 28 Ti rotor (Beckman). 1.13 mL fractions were then collected using the Gradient Station model 153 ...
-
bioRxiv - Biochemistry 2023Quote: ... Gradients were centrifuged at 35K rpm for 3 hrs at 4°C in a SW-41Ti rotor (Beckman) with maximum acceleration and no brake using a Beckman Optima L-90 Ultracentrifuge ...
-
bioRxiv - Developmental Biology 2024Quote: ... followed by ultracentrifugation at 120,000 × g at 4 °C for 2 hours (Beckman, TLA120.4 rotor). The resulting pellets were washed in cold PBS and underwent a second ultracentrifugation at 120,000 × g at 4 °C for 2 hours ...
-
bioRxiv - Plant Biology 2021Quote: ... reinhardtii cells were collected at 1,870 × g and 4°C for 5 min (JLA9.1000, Beckman Coulter). The cells were resuspended at 0.125 mg Chl/mL with disruption buffer containing 25 mM MES-NaOH (pH 6.5) ...
-
bioRxiv - Biochemistry 2021Quote: ... and centrifuged for 5 h with 116,000 xg at 4°C in a TLA100.3 rotor (Beckman). Binding to the different fractions was assessed by Western blot ...
-
bioRxiv - Immunology 2021Quote: ... and centrifuged (400×g for 5 min at 4°C) using a swinging bucket rotor (Beckman Coulter Avanti J-15RIVD with JS4.750 swinging bucket ...
-
bioRxiv - Immunology 2022Quote: ... and centrifuged (400×g for 5 min at 4°C) using a swinging bucket rotor (Beckman Coulter Avanti J-15RIVD with JS4.750 swinging bucket ...
-
bioRxiv - Microbiology 2022Quote: ... 5 mM CaCl2 buffer background) were placed in a 4 mL UltraClear ultracentrifuge tube (Beckman-Coulter), with the particle sample as the top layer ...
-
bioRxiv - Cancer Biology 2024Quote: ... and centrifuged at 100,000 × g for 5 hours at 4°C (MLS-50, Beckman Coulter, 326819). Afterwards ...
-
bioRxiv - Biochemistry 2020Quote: ... One was through twice daily measurement of 2 or 3 levels of QC specimens obtained from Beckman Coulter Inc ...
-
bioRxiv - Biophysics 2021Quote: ... The VP2 capsid protein fractions were pooled and subjected to centrifugation at 28,000 rpm (139,065 × g) for 3 h at 4°C (Sw40Ti rotor, Beckman Coulter). The pellet was resuspended in 50 mM Tris (pH 7.4) ...
-
bioRxiv - Cell Biology 2021Quote: ... and centrifuged at 97,658 x g for 3 h at 4°C using a SW41Ti rotor (Beckman & Coulter, # 331362). The polysome fractions were collected using the Foxy R1 Fraction Collector and immediately snap frozen with liquid nitrogen and stored at −80 °C ...
-
bioRxiv - Plant Biology 2020Quote: ... 50 μg/ml cycloheximide) and centrifuged for 3 h at 55,000 g and 4 °C in a Type 70 Ti rotor (Beckman). The pellet was dissolved in 1% SDS ...
-
bioRxiv - Molecular Biology 2022Quote: ... Gradients were spun for 3 hours at 4° C and 36,000 RPM (221,632 x g) on SW41-Ti rotor (Beckman Coulter). Monosome fractions were isolated from each sucrose gradient with Brandel Density Gradient Fractionator using 1.5 mL/min flow speed and 60% CsCl ...
-
bioRxiv - Biochemistry 2022Quote: ... The membrane was solubilized for 3 hours at 4°C before separation by ultracentrifugation at 100,000 g (Ti45, Beckman) for 45 min ...
-
bioRxiv - Neuroscience 2022Quote: ... supernatant was centrifuged for 3 h at 115,000 g and 4°C using the XPN-80 ultracentrifuge equipped with a Ti70 rotor (Beckman). EV pellets were resolved in 1 mL ice-cold PBS (Gibco ...
-
bioRxiv - Microbiology 2023Quote: ... The tube was centrifuged for 3 hours at 150’000 x g (4°C) using a SW 32.1 Ti swinging bucket (369651, Beckman Coulter). Finally ...
-
bioRxiv - Neuroscience 2023Quote: ... the liposomes were isolated by centrifugation for 3 h 40 mins at 55,000 rpm at 4°C in a SW 60 rotor (SW 60 Ti, Beckman). 20 µl were harvested from the top of the gradient and mixed with 8 µl of 4x Laemmli buffer (final 62.5 mM Tris-HCl ...
-
bioRxiv - Neuroscience 2024Quote: ... Tubes were centrifugated at 100,000 x g (32,500 RPM) for 3 hours at 4°C using a SW55Ti rotor (Beckman Coulter). Synaptosomes enriched in the interface between 1.0-1.25 M sucrose were collected and diluted with ice-cold 0.1 mM CaCl2 ...
-
bioRxiv - Microbiology 2024Quote: ... the supernatants were loaded onto 1 mL of 30% sucrose in PBS buffer and centrifuged at 25,000 rpm at 4°C for 3 hours using the 90AT rotor (Beckman). The pelleted viral particles were resuspended in 100 μL of PBS and fixed with formaldehyde (working concentration 0.1% ...
-
bioRxiv - Cell Biology 2024Quote: ... The 100,000xg SEV-containing pellets were resuspended in 3 ml sterile cold PBS and repelleted at 100,000xg for 4 hrs in a TLA110 rotor (Beckman). SEVs were analyzed for size and number by nanoparticle tracking (ZetaView ...
-
bioRxiv - Cell Biology 2021Quote: ... After centrifugation (285, 000 g for 2 h at 4 °C using a Beckman SW40Ti rotor), polysome profiles were recorded using an Äktaprime plus chromatography system (GE Healthcare) ...
-
bioRxiv - Microbiology 2022Quote: ... 4°C for 2 h (SW 32 Ti swinging-bucket rotor, Optima LE-80K Beckman Coulter) using a 25% w/v sucrose cushion ...