Labshake search
Citations for Beckman :
1 - 50 of 256 citations for 7 Amino 1H benzimidazole 5 carboxylic acid since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Bioengineering 2021Quote: ... or 7-Amino-Actinomycin D (7-AAD, Beckman Coulter, B88526) was added to the cell suspensions ...
-
bioRxiv - Cancer Biology 2023Quote: ... After 5-7 days cells were counted using a Z1 Coulter Particle Counter (Beckman Coulter).
-
bioRxiv - Physiology 2020Quote: The Sfaa was determined through high performance liquid chromatography (HPLC) separation of the free amino acid pool (FAA) and liquid scintillation counting (Beckman Coulter LS 6500, Brea CA) of the alanine elution peak ...
-
bioRxiv - Genetics 2023Quote: ... Libraries were amplified using 5-7 cycles of PCR using KAPA HiFi DNA polymerase and purified with 1.1X SPRI (Beckman Coulter). Nucleosome profiles were manually inspected using a Tapestation with the D1000 Screen Tape system (Agilent) ...
-
bioRxiv - Biochemistry 2023Quote: ... followed by centrifugation at ∼28500g for 1h at 4°C (Beckman Coulter centrifuge, JA-14) in order to remove cell debris ...
-
bioRxiv - Cell Biology 2020Quote: ... Both subfractions were centrifuged in a Ti50 rotor at 225,000g for 1h (Beckman Type 70.1Ti rotor) at 4C ...
-
bioRxiv - Biochemistry 2022Quote: ... Insoluble material was removed by ultracentrifugation at 158,000 ×g for 1h (Beckman L-90K, Ti70 rotor), and membranes were filtered with a 0.45 μm syringe filter and applied to a 0.5 mL anti-FLAG M2 affinity gel in a column (Millipore Sigma ...
-
bioRxiv - Biochemistry 2023Quote: ... followed by lysate centrifugation at ∼28500g for 1h at 4°C (Beckman Coulter centrifuge, JA-14). The supernatant was incubated for 45min ...
-
bioRxiv - Biochemistry 2023Quote: ... the lysate was centrifuged at ∼18000g for 1h at 4°C (Beckman Coulter centrifuge, JA-20) and the supernatant incubated for 45min ...
-
bioRxiv - Neuroscience 2022Quote: ... Insoluble material was removed by ultracentrifugation (1h, 4°C, 40,000 rpm, Ti70 rotor, Beckman Coulter Cat#337922). The fragments were immobilized onto glutathione Sepharose (Millipore/Cytiva Cat#17-5132-02 ...
-
bioRxiv - Biochemistry 2023Quote: ... After ultracentrifugation for 1h at 258,488 x g at 4°C using a TLS-55 rotor (Beckman), the fractions were analysed by SDS-PAGE and the positive fractions were concentrated ...
-
bioRxiv - Biochemistry 2023Quote: ... The lysate was then centrifuged at ∼28500g for 1h at 4°C (Beckman Coulter centrifuge, JA-14) and the supernatant incubated for 1h ...
-
bioRxiv - Microbiology 2020Quote: ... 1mM dithiothreitol and 100μg/ml cycloheximide) and spun for 1h at 100K RPM using TLA-110 rotor (Beckman) at 4c ...
-
bioRxiv - Molecular Biology 2020Quote: ... Lysates were cleared by spinning at 3,000xg followed by 20,000xg for 10min each and supernatant were loaded on a 30% sucrose cushion and spun for 1h at 31,200 r.p.m in SW60 rotor (Beckman Coulter). The non-polysomal supernatant was removed and polysomes collected below the sucrose layer was diluted with the hypotonic buffer [10mM HEPES pH 7.8 ...
-
bioRxiv - Microbiology 2020Quote: ... 1mM dithiothreitol and 100μg/ml cycloheximide) and spun for 1h at 100K RPM using TLA-110 rotor (Beckman) at 4c ...
-
bioRxiv - Microbiology 2021Quote: ... incubated samples for 7 min, centrifuged (650 x g, 7 min, RT) and measured them by flow cytometry (Cytomics FC500, Beckman Coulter, USA) after resuspension in Tyrode’s buffer ...
-
bioRxiv - Microbiology 2020Quote: ... the 100,000xg centrifugation was performed for 1h at 4°C using a SW41 TI swinging bucket rotor (Beckman Coulter). The pellet was then resuspended in 50 μL or 1500 μL of D-MEM for subsequent analysis.
-
bioRxiv - Cell Biology 2020Quote: ... Fractions were diluted and washed in PBS for 1h at 100,000 x g in a TLA 110 rotor (Beckman). Fractions were resuspended in 35 ul of PBS ...
-
bioRxiv - Biophysics 2021Quote: ... 20-24 h), the samples were ultracentrifuged (1h, 288’000 x g) (Optima TLX Ultracentrifuge, Beckman Coulter, TLA-120.2 Beckman rotor) to remove large aggregates ...
-
bioRxiv - Cell Biology 2023Quote: ... Equilibrated tubes were ultra-centrifuged at 100,000xg for 1h at 4°C using a swinging-bucket rotor (SW 32Ti, Beckman Coulter ...
-
bioRxiv - Developmental Biology 2023Quote: ... the supernatant was centrifuged in a TLA100.4 fixed angle rotor at 100000 g for 1h at 37°C in an Optima TL ultracentrifuge (Beckman). The supernatant containing globular actin was collected ...
-
bioRxiv - Cancer Biology 2021Quote: ... The pellet was washed with PBS and ultracentrifuged at 100,000 × g 1h at 4°C to obtain small vesicles (TL-100 Ultracentrifuge, Beckman Coulter). The final pellet was resuspended in PBS for subsequent experiments ...
-
bioRxiv - Biochemistry 2020Quote: ... the crude mitochondria were undergone a sucrose gradient in SEM buffer for 1h at 139,400 x g with an SW40 Ti rotor (Beckman Coulter). Mitochondrial band was pooled and stored at −80 °C.
-
bioRxiv - Microbiology 2021Quote: ... The membrane fraction was prepared using ultracentrifugation (45,000 rpm, 4 °C, 1h; Optima-90 ultracentrifuge, Beckman-Coulter, Brea, CA, USA) and washed once in 200 mM ABC buffer ...
-
bioRxiv - Microbiology 2021Quote: ... The resting supernatants were filtered through 0.45µm syringe filters and ultracentrifuged at 100,000 x g for 1h at 4°C (SW41 Ti swinging-bucket rotor, Beckman Coulter). The supernatant was discarded and the pellet suspended in 0.22 µm-pore filtered or 0.02 µm-pore filtered (for Flow Cytometry analysis ...
-
bioRxiv - Cell Biology 2023Quote: ... Equilibrated tubes were ultra-centrifuged at 100,000xg for 1h at 4°C using a swinging-bucket rotor (SW 32Ti, Beckman Coulter, 369650; Optima XE, Beckman Coulter). Phagosome-containing beads float at the interface between the 10% and 25% layers ...
-
bioRxiv - Neuroscience 2023Quote: ... and samples were centrifuged at 24,000 rpm at 4°C for 1h in a SW41Ti Swinging-Bucket Rotor (Beckman Coulter). After discarding the supernatant ...
-
bioRxiv - Microbiology 2023Quote: ... Cells were washed twice with 200µl BD 1X Perm/Wash solution and stained 1h at 4°C with anti-HIV-1 p24 (RD1/PE, Beckman Coulter #6604667 ...
-
bioRxiv - Microbiology 2022Quote: ... and the viral particles were concentrated by ultracentrifugation for 1h at 30,000 rpm at 4°C in an SW40 rotor (Beckman, Fullerton, CA). Viral pellets were resuspended in TNC buffer (10 mM Tris-HCl [pH 7.5] ...
-
bioRxiv - Cell Biology 2020Quote: ... The supernatants were collected and subjected to high-speed centrifugation at 100,000 × g for 1h (TLS-55 rotor, OptimaTMMAX Ultracentrifuge; Beckman Coulter, Germany). The supernatants (S100 ...
-
bioRxiv - Neuroscience 2023Quote: ... 7-color cell sorter using Summit software (Beckman Coulter Life Sciences). The sorted RFP+ only and RFP+/GFP+ cell populations were collected and replated on coverslips with pre-seeded HA cells in NDM ...
-
bioRxiv - Biochemistry 2020Quote: ... disrupted with a tip sonicator at 1/3 power (8 MHz) for 3 × 30 seconds on ice and fractionated by ultracentrifugation (100’000 x g, 1H, Beckman TLA 120.2 rotor). The luminal fraction was concentrated to around 50 µL on a 3 kDa MWCO Amicon Ultra 0.5 mL centrifugal filter while membrane pellets were dissolved in 50 µL TBS with 2% SDS ...
-
bioRxiv - Cell Biology 2021Quote: ... Apoptosis was analyzed using Annexin V-FITC / 7-AAD kit (Beckman Coulter) according to the manufacturer’s protocol ...
-
bioRxiv - Biochemistry 2019Quote: ... To collect the membrane fraction the cleared supernatant was centrifuged at 100,000g at 4°C for 1h in a Beckman Optima MAX ultracentrifuge with a TLA110 rotor using polycarbonate thick wall centrifuge tubes (Beckman coulter ref. 362305). The supernatant that contains soluble proteins was removed and the pellet-containing membranes was resuspended in 1ml ice-cold homogenization buffer by sonication and re-centrifuged at 100,000g ...
-
bioRxiv - Plant Biology 2023Quote: ... The disrupted cells were subjected to ultracentrifugation at 4°C and 235000 g for 1h (Beckman Optima™ L-80 XP, rotor Ti45). The resulting supernatant was loaded onto an Äkta purifier system (GE HealthCare ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... and supernatants were ultracentrifuged at 37 000 rpm (~100 000 g) and 10°C for 1h (Beckman Optima LE-80 K; rotor 70.1.Ti). Pellets were resuspended in 100μL of buffer (10 mM Tris-HCL ...
-
bioRxiv - Biophysics 2021Quote: ... Following incubation (37 °C, 20-24 h), the samples were ultracentrifuged (1h, 288’000 x g) (Optima TLX Ultracentrifuge, Beckman Coulter, TLA-120.2 Beckman rotor) to remove large aggregates ...
-
bioRxiv - Cell Biology 2020Quote: ... The mixtures were loaded into ultracentrifuge tubes (7 x 20 mm, Beckman Coulter) and fractionated at 100,000Xg using a Beckman TL-100 ultracentrifuge ...
-
bioRxiv - Cancer Biology 2022Quote: ... GFP+7-AAD- cells were sorted using MoFlo XDP Cell Sorter (Beckman Coulter) or FACSAria III Cell Sorter (Becton Dickinson) ...
-
bioRxiv - Biochemistry 2021Quote: ... The UV-Visible spectrum of each sample was recorded for both tannic acid and gallic acid for both pH’s using a DU730 UV-Visible Spectrometer (Beckman Coulter, Pasadena, CA). The spectra were recorded from 250-400 nm with 0.2 nm data intervals ...
-
bioRxiv - Genomics 2022Quote: ... Nucleic acid purification was performed using SPRI Select (BECKMAN COULTER), nucleic acid concentration was determined by Qubit High Sensitivity DNA assay (Thermo Fisher) ...
-
bioRxiv - Cell Biology 2020Quote: ... PEG was removed via centrifugation at 136,000 xg for 7 minutes in TLA100.3 (Beckman Ultracentrifuge), and supernatant was pre-cleared by incubating with Protein A Sepharose beads (GE LifeSciences #17127901 ...
-
bioRxiv - Biochemistry 2020Quote: ... Lysates were transferred to 7 x 20mm polycarbonate thick-wall tubes (Beckman Coulter, Krefeld, Germany) for ultra-centrifugation (centrifuge Optima TLX with rotor TLA 100 ...
-
bioRxiv - Immunology 2021Quote: ... After purification of nucleic acids by Agencourt RNA Clean XP (Beckman Coulter) and subsequent treatment with DNase I ...
-
bioRxiv - Immunology 2023Quote: ... lysates were fractionated on a linear sucrose gradient (7–47%) using the SW-41Ti rotor (Beckman Coulter) at 221,633x g for 2lllhours at 4 °C ...
-
bioRxiv - Genetics 2022Quote: ... 5 mL (Beckman Coulter, B23317) using a DynaMag™-2 Magnet magnetic stand (Thermo Fisher Scientific ...
-
bioRxiv - Cancer Biology 2019Quote: ... Sucrose gradients (7-47%) were centrifuged at 39,000 rpm with a SW41-Ti Rotor (Beckman Coulter, Fullerton, CA) for 90 min at 4 °C ...
-
bioRxiv - Cell Biology 2020Quote: ... Unbound protein was separated from liposomes by transferring 100μl of this mixture to 7×20mm PC ultracentrifuge tubes (Beckman) and carefully layering an equal volume of 0.75M sucrose buffer followed by 25μl of sucrose-free HK buffer ...
-
bioRxiv - Cell Biology 2019Quote: ... Coverslips were mounted on bottomless 35 mm dishes with a 7 mm microwell using silicone vacuum grease (Beckman Coulter). Conditioned media from the coverslip’s well ...
-
bioRxiv - Neuroscience 2023Quote: ... Fractions were washed by diluting with 7 mL of PBS and ultracentrifuged at 100,000 x g (Type 70.1 Ti rotor, Beckman Coulter) for 2 h ...