Labshake search
Citations for Beckman :
201 - 250 of 1885 citations for 6H Imidazo 4 5 h quinolin 6 one 1 9 dihydro 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2022Quote: ... The gradients were ultra-centrifuged for 3 h at 175,000g at 4°C in a SW41Ti rotor (Beckman-Coulter, USA) and analyzed by measuring the absorbance continuously at 260 nm using a piston gradient fractionator (Biocomp Instruments) ...
-
bioRxiv - Microbiology 2023Quote: ... The filtrate was ultracentrifuged at 100,000 ×g at 4 °C for 2 h using an Optima XE-90 (Beckman Coulter) to collect EMVs ...
-
bioRxiv - Molecular Biology 2023Quote: 8 mL of viral supernatant on a 3 mL of 20% sucrose cushion were ultracentrifugated for 3 h at 100,000 x g at 4°C using an Optima L80-XP instrument (Beckman Coulter). After ultracentrifugation ...
-
bioRxiv - Systems Biology 2023Quote: ... Gradients were centrifuged at 4°C for 17 h at 100,000 g using an L7 ultracentrifuge with an SW28 swing out rotor (Beckman Coulter). Fractions (F ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was centrifuged at 300,000×g at 4°C for 3 h in a TLA-110 fixed angle rotor (k-factor 13) (Beckman Coulter). The pellet was resuspended in 10 µL PBS of which 3 µL was adsorbed onto glow-discharged 2 nm carbon layer coated Quantifoil R1.2/1.3 400 mesh gold grids ...
-
bioRxiv - Cell Biology 2023Quote: ... Each fraction was subjected to a washing step in ice-cold PBS at 100,000 × g at 4°C for 2 h using a SW28Ti rotor (Beckman Coulter). The pelleted EVs were resuspended in ice-cold PBS ...
-
bioRxiv - Cell Biology 2023Quote: ... The obtained supernatant was layered onto 30 w/v% sucrose solution in ultracentrifugation tubes and subjected to ultracentrifugation at 100,000 × g for 3 h at 4°C using SW32Ti rotor (Beckman courter). The collected sucrose solutions were mixed with PBS and washed by ultracentrifugation at 100,000 × g for 1 h ...
-
bioRxiv - Plant Biology 2023Quote: ... Approximately 250 µl of crude EV sample resuspended in 20 mM Tris-HCl pH 6.0 was slowly dispensed on top of the column and centrifuged at 100,000 x g for 17 h at 4 ⁰C (SW 41 Ti rotor, Beckman Coulter; OptimaTM L-90K, Beckman Coulter). After the ultracentrifugation ...
-
bioRxiv - Plant Biology 2023Quote: ... The resulting solution was then centrifuged again at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Avanti J-20TM centrifuge, Beckman Coulter). The supernatant was decanted ...
-
bioRxiv - Plant Biology 2023Quote: ... The supernatant from this step was decanted into the new tubes and centrifuged at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Beckman Coulter; Avanti J-20TM centrifuge, Beckman Coulter). The supernatant was then decanted and discarded ...
-
bioRxiv - Neuroscience 2023Quote: ... The gradients were centrifuged for 18 h at 100,000 xg at 4 °C in a SW 40 rotor (Beckman Coulter). 500 µl fractions were collected from the top of the ultracentrifuge tubes and analyzed by WB analysis.
-
bioRxiv - Cell Biology 2023Quote: ... The gradient was centrifuged at 4 °C and 100,000 ˗ g for 18 h (Optima L-80 XP Ultracentrifuge with Swing Rotor (Beckman Coulter)) ...
-
bioRxiv - Developmental Biology 2023Quote: ... The resulting supernatant was subjected to ultracentrifugation at 120,000 × g at 4°C for 2 h (Optima Max TL, Beckman Coulter). Pellets were resuspended in 1 ml cold PBS and centrifuged at 120,000 × g at 4°C for 2 h ...
-
bioRxiv - Microbiology 2023Quote: ... sucrose gradients prepared with buffer C and centrifuged for 16 h at 71,935 g at 4 °C in a SW28 rotor (Beckman Coulter). Gradients were fractionated on a Biocomp Piston Gradient Fractionator (BioComp Instruments ...
-
bioRxiv - Microbiology 2023Quote: ... Medium was cleared from EVs by ultracentrifugation at 100,000 ×g for 18 h at 4°C in a LE-80 ultracentrifuge (Beckman Coulter) with a 60Ti rotor [13] ...
-
bioRxiv - Microbiology 2023Quote: ... Media was cleared from EVs by ultracentrifugation at 100,000×g for 18 h at 4 °C in a LE-80 ultracentrifuge (Beckman Coulter) with a 60Ti rotor ...
-
bioRxiv - Cell Biology 2023Quote: ... The concentrated CFS was then ultracentrifuged at 100,000 ˗ g and 4 °C for 3 h (Optima L-80 XP Ultracentrifuge with Type 70.1 Ti Fixed-Angle Titanium Rotor (Beckman Coulter)) ...
-
bioRxiv - Biophysics 2023Quote: ... Centrifugation was performed at 154,300 × g for 24 h at 4◦C (SW 41 Ti swinging-bucket rotor, Beckman Coulter). The separated bands were collected dropwise from the bottom of the tube ...
-
bioRxiv - Cell Biology 2024Quote: ... Gradients were centrifuged at 36,000 rpm for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Following centrifugation ...
-
bioRxiv - Cell Biology 2024Quote: ... The same amounts of proteins were loaded on a double sucrose cushion (20% and 30% sucrose) and centrifuged at 190,000 g for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Extracts were incubated with pre-washed anti-Flag beads (Sigma ...
-
bioRxiv - Cell Biology 2023Quote: ... The samples were sedimented by velocity centrifugation at 36,000 x rpm for 2 h at 4°C using SW40Ti rotor in Optima L-80XP ultracentrifuge (Beckman Coulter). Absorbance at 254 nm was measured from lower to higher sucrose gradients using an ISCO gradient fractionation system and the optical density at 254 nm was continuously recorded with a Foxy JR Fractionator (Teledyne ISCO).
-
bioRxiv - Molecular Biology 2024Quote: ... and spun at 32,000 rpm (max 124,436 rcf) and 4 ºC for 13 h using an SW55Ti rotor in an Optima L80 centrifuge (Beckman Coulter). The samples were fractionated from the top of the sucrose gradient ...
-
bioRxiv - Biochemistry 2024Quote: ... The protein samples were carefully applied to the gradient and centrifuged for 16 h at 130,000 g at 4 °C (Optima XPN-80 Ultracentrifugation from Beckman Coulter). 200 µl fractions were taken from the top of the gradient and the glutaraldehyde quenched with 20 mM Tris pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: ... and 1 mM dithiothreitol) and spun for 1 h at 100,000 rpm using TLA-110 rotor (Beckman) at 4 °C ...
-
bioRxiv - Biophysics 2020Quote: ... After ultra-centrifugation at 40,000 rpm for 1 h in Ti45 rotor (Beckman), the supernatant was loaded onto 7 ml MBP resin ...
-
bioRxiv - Immunology 2021Quote: ... centrifuged at 42,000 RPM for 1 h (45 Ti fixed-angle rotor, Beckman), and the supernatant was used for affinity chromatography with anti-FLAG M2 affinity gel (Sigma ...
-
bioRxiv - Immunology 2021Quote: ... Soluble CuMV-CP-containing protein solution was separated from the cellular proteins by ultracentrifugation in a sucrose gradient (20%-60% sucrose; ultracentrifugation at 25,000 rpm for 6 hours at 5°C [SW28 rotor, Beckman]). After dialysis CuMVTT-containing gradient fractions ...
-
bioRxiv - Cell Biology 2023Quote: ... down to 6 ml and ultracentrifuged at 10,000xg for 16 min at 4°C in MLA-80 rotor (Beckman Coulter). The pellet was resuspended and washed with PBS at the same conditions (volume ...
-
bioRxiv - Cancer Biology 2023Quote: ... cells were seeded into 6-well plates at a concentration of 4×105 cells per well and counted cumulatively with a Coulter counter (Beckman) every three days for two weeks ...
-
bioRxiv - Cell Biology 2019Quote: ... by ultracentrifugation at 150,000 × g for 12 h at 4°C using an Optima L-100XP centrifuge equipped with a SW55Ti rotor (Beckman Coulter). Eleven fractions were collected from the top of the sucrose gradient.
-
bioRxiv - Plant Biology 2020Quote: ... The loaded density gradients were centrifuged at 33,000 g for 14.5 h at 4°C using a six-position SW41 Ti rotor (Beckman Coulter, Kerfeld, Germany). The positions of ribosome complexes varied slightly with each centrifugation run that comprised a set of six samples ...
-
Adaptive translational pausing is a hallmark of the cellular response to severe environmental stressbioRxiv - Molecular Biology 2020Quote: ... and centrifuged at 4°C at 31,000 rpm for 2 h and 30 min using an SW 32 Ti rotor(Beckman Coulter, 369694). The gradients were fractionated using a Teledyne ISCO Density Gradient Fractionation System and 12 fractions were collected ...
-
bioRxiv - Molecular Biology 2019Quote: ... EDS was obtained after 18 h ultracentrifugation at 100,000 g and 4 °C (SW55 Ti rotor, Beckman Coulter, Fullerton, California, USA), followed by 0.22 µm filtration ...
-
bioRxiv - Molecular Biology 2019Quote: ... followed by 3 h ultracentrifugation at 100,000 g and 4 °C using SW 32.1 Ti rotor (Beckman Coulter, Fullerton, California, USA). Resulting pellets were resuspended in 100 µl PBS and stored at −80 °C until further use ...
-
bioRxiv - Cell Biology 2020Quote: ... Reconstituted nucleosome samples were overlaid onto the sucrose gradient and spun at 32000 rpm for 20 h at 4 ° using SW55Ti rotor (Beckman Coulter) in Beckman Optima L80 ...
-
bioRxiv - Microbiology 2020Quote: ... The supernatant was ultracentrifuged at 120,000 g for 3 h at 4°C using an MLS-50 rotor (Beckman Coulter, USA) to collect 120k pellet vesicles ...
-
bioRxiv - Genomics 2021Quote: ... The samples were then centrifuged at 28,600 rpm for 2 h at 4°C (Beckman Optima XE-90; SW32 Ti rotor). After centrifugation ...
-
bioRxiv - Immunology 2020Quote: ... Vesicles recovered by ultracentrifugation of filtered supernatant at 150,000 x g for 2 h at 4 °C using a Ti 45 rotor (Beckman Instruments, USA), were washed with phosphate-buffered saline (PBS ...
-
bioRxiv - Biophysics 2023Quote: ... the SWCNT suspension was centrifuged at 30000 rpm (164 000 x g) for 4 h at 25 °C (Optima XPN-80, Beckman Coulter) to remove any remaining nanotube aggregates.
-
bioRxiv - Biophysics 2022Quote: ... EVs were separated from protein aggregates and free reagents by bottom-up density gradient centrifugation in sucrose for 17.30 h at 192,000 g and 4°C using a SW40 rotor (k-factor 144.5; Beckman Coulter, Fullerton, California, USA). Twelve fractions of 1 mL were then collected from the top of the gradient and respective densities were determined by refractometry using an Atago Illuminator (Japan) ...
-
bioRxiv - Bioengineering 2023Quote: ... The gradient tubes were balanced and subjected to centrifugation at 135,000 × g for 2 h at 4 °C using a fixed-angle rotor (TLA-55, Beckman Coulter, USA). After DGUC ...
-
bioRxiv - Bioengineering 2023Quote: ... The gradient tubes were subjected to centrifugation at 135,000 × g for 2 h at 4 °C using a fixed-angle rotor (TLA-55, Beckman Coulter, USA). After DGUC ...
-
bioRxiv - Bioengineering 2023Quote: ... The gradient tube was balanced and subjected to ultracentrifugation at 150,000 × g for 2 h at 4 °C using a swinging-bucket rotor (SW 41 Ti Beckman Coulter, USA).
-
bioRxiv - Cell Biology 2024Quote: ... The samples were ultracentrifuged at 39,000 rpm at 4°C for 2.5 h in an SW41 rotor (Beckman Coulter, California, USA). Finally ...
-
bioRxiv - Cell Biology 2024Quote: ... Samples were then spun at 100,000 xg for 16 h at 4°C using a TLS-55 swinging-bucket rotor and benchtop ultracentrifuge (Optima Max-XP, Beckman Coulter). Fractions were collected and loaded in SDS-PAGE for WB.
-
bioRxiv - Molecular Biology 2022Quote: ... Stained cells and fluorescence minus one controls were then resuspended in SB + 1:1000 DNase + 1:1000 Draq7 (Beckman Coulter) as a live/dead stain ...
-
bioRxiv - Cell Biology 2019Quote: ... Samples were then centrifuged for 1 h in an SW 40 Ti rotor (Beckman) at 141,000 × g ...
-
bioRxiv - Biochemistry 2020Quote: ... The supernatant was centrifuged at 40,000 rpm for 1 h in Ti45 rotor (Beckman) to harvest cell membrane in pellets ...
-
bioRxiv - Cell Biology 2020Quote: ... Exosomes were then pelleted (TLA-100 rotor Beckman, 1 h at 90 000 rpm). Supernatants and pellets were then loaded on 12% SDS-PAGE and the indicated proteins were analyzed by Western blot.
-
bioRxiv - Immunology 2020Quote: ... and ultracentrifuged at 40,000 RPM for 1 h (45 Ti fixed-angle rotor, Beckman). The soluble proteome was incubated with pre-equilibrated anti-FLAG M2 affinity gel (Sigma ...