Labshake search
Citations for Beckman :
1 - 50 of 763 citations for 6 methoxy 2 phenyl 3 2H tetrazol 5 ylmethylsulfanyl 1H indole since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2020Quote: ... filtered through 45 μm-pore size filters and concentrated onto a 20% sucrose cushion by ultracentrifugation (24,000 rpm, 2h, 6°C) using a SW32 rotor (Beckman). HIV-1-based lentiviral particles were produced by co-transfecting 293T cells with packaging (psPAX2) ...
-
bioRxiv - Cell Biology 2022Quote: ... and the post-nuclear supernatant was loaded onto an 8-step discontinuous sucrose density gradient (HEPES-buffered 0.2–2 M sucrose) and centrifuged at 55,000 rpm for 2h at 4 °C using an MLS50 rotor (Beckman Coulter). Extracellular acidification rate (ECAR ...
-
bioRxiv - Cell Biology 2022Quote: ... were mixed 1:1 with liposomes (6 mg/ml) and floated for 2h at 55 000 rpm in a TLS-55 rotor (Beckman) at 25°C through a sucrose gradient ...
-
bioRxiv - Biochemistry 2020Quote: ... disrupted with a tip sonicator at 1/3 power (8 MHz) for 3 × 30 seconds on ice and fractionated by ultracentrifugation (100’000 x g, 1H, Beckman TLA 120.2 rotor). The luminal fraction was concentrated to around 50 µL on a 3 kDa MWCO Amicon Ultra 0.5 mL centrifugal filter while membrane pellets were dissolved in 50 µL TBS with 2% SDS ...
-
bioRxiv - Cell Biology 2022Quote: ... were mixed 1:1 with liposomes (5 mg/ml) and floated for 2h at 55,000 rpm in a TLS-55 rotor (Beckman) at 25 °C through a sucrose gradient ...
-
bioRxiv - Neuroscience 2022Quote: ... gradient (6 ml 17 %, 6 ml 25 %, 5 ml 40 % and 5 ml 60 %) contained within an OptiSeal tube (Beckman,). Gradients were spun at 242 000 g at 16 °C and the viral fraction was harvested from the 40 % fraction with a 21-gauge needle ...
-
bioRxiv - Cancer Biology 2022Quote: ... 5×10^6 cells counted by Multisizer 4e Coulter Counter (Beckman) were plated on a 60 mm plate and serum starved before analysis unless otherwise indicated ...
-
bioRxiv - Biochemistry 2021Quote: ... 6 mM 2-mercaptoethanol and centrifuged with a 70Ti (Beckman coulter) rotor at 40,000 rpm for 18 hours at 4°C ...
-
bioRxiv - Cell Biology 2020Quote: ... Gradients were then centrifuged for 2h 45 min on 35.000 rpm (Beckman Coulter ...
-
bioRxiv - Microbiology 2020Quote: ... the VLPs were concentrated by ultracentrifugation (40,000 rpm, 2h, 10°C, Beckman SW41 rotor), resuspended in buffer A and observed by TEM ...
-
bioRxiv - Neuroscience 2024Quote: ... and centrifuged at 28,000rpm for 2h at 4 °C in a SW 41 rotor (Beckman). The virus pellet was resuspended in 60μL of PBS ...
-
bioRxiv - Cancer Biology 2020Quote: ... 3 and 5 and counted using a particle counter (Z1; Beckman Coulter, Inc.). Experiments were carried out in triplicate ...
-
bioRxiv - Molecular Biology 2020Quote: ... Samples were ultracentrifuged at 95,000 rpm at 4°C for 2h using a TLA100.2 rotor (Beckman). The pellets were resuspended in 200 µL of W-Buffer and treated with 1% SDS (Sigma cat ...
-
Plasma derived cell-free mitochondrial DNA originates mainly from circulating cell-free mitochondriabioRxiv - Genomics 2021Quote: ... and finally centrifuged at 200,000 g for 2h at 4°C (Beckman MLA-130 Ultracentrifuge Rotor). After each centrifugation step ...
-
bioRxiv - Neuroscience 2021Quote: ... KG, Staufen, Germany) (position 6, 4 × 5-s bursts) and subsequently centrifuged at 48,000g at 4°C (Beckman Avanti J-251 Ultracentrifuge ...
-
bioRxiv - Neuroscience 2021Quote: ... after which the supernatant was filtered (0.45 µm filter) and centrifuged 2h at 19,400 rpm (SW28 Beckman rotor). The pellets were re-suspended in phosphate buffered saline (PBS ...
-
bioRxiv - Biochemistry 2023Quote: ... followed by centrifugation at ∼28500g for 1h at 4°C (Beckman Coulter centrifuge, JA-14) in order to remove cell debris ...
-
bioRxiv - Immunology 2021Quote: ... Soluble CuMV-CP-containing protein solution was separated from the cellular proteins by ultracentrifugation in a sucrose gradient (20%-60% sucrose; ultracentrifugation at 25,000 rpm for 6 hours at 5°C [SW28 rotor, Beckman]). After dialysis CuMVTT-containing gradient fractions ...
-
bioRxiv - Cancer Biology 2021Quote: ... at the bottom as the cushion and centrifuged at 50,000 × g for 2h using an SW32Ti rotor (Beckman Coulter). After centrifugation ...
-
bioRxiv - Neuroscience 2019Quote: ... of the lysates were loaded on top of the gradients and spun at 36,000 rpm at 4°C for 2h with a SW41-Ti rotor (Beckman). Fractions from each sample were collected every 9 sec using a density gradient fractionation system (Teledyne Isco ...
-
bioRxiv - Microbiology 2022Quote: ... at 4°C for 1.5-2h followed by 180,000 x g (Ti 70i rotor; Beckman Instruments, Inc., Fullerton, CA) at 4°C for 1.5-2h and resuspended in 1mL of phosphate buffered saline (PBS ...
-
bioRxiv - Microbiology 2022Quote: ... which was spun in a ultracentrifuge at 30,000 x g for 2h at 4°C (SW 60 Ti rotor, Beckman) The pellet was resuspended in 20 μl of PBS for 1 h at 4 °C ...
-
bioRxiv - Pathology 2023Quote: ... and culture supernatant was concentrated by ultracentrifugation (2h at 26,000rpm; Ultraclear Tubes; SW28 rotor and Optima L-100 XP Ultracentrifuge; Beckman). Viruses were suspended in cold sterile PBS and titrated by transduction of Jurkat cells for 48h ...
-
bioRxiv - Neuroscience 2024Quote: ... The total 200mL of supernatant was centrifuged at 28,000rpm for 2h at 40 °C in a 45Ti rotor (Beckman), which can sustain faster speeds ...
-
bioRxiv - Cell Biology 2020Quote: ... Both subfractions were centrifuged in a Ti50 rotor at 225,000g for 1h (Beckman Type 70.1Ti rotor) at 4C ...
-
bioRxiv - Biochemistry 2022Quote: ... Insoluble material was removed by ultracentrifugation at 158,000 ×g for 1h (Beckman L-90K, Ti70 rotor), and membranes were filtered with a 0.45 μm syringe filter and applied to a 0.5 mL anti-FLAG M2 affinity gel in a column (Millipore Sigma ...
-
bioRxiv - Biochemistry 2023Quote: ... followed by lysate centrifugation at ∼28500g for 1h at 4°C (Beckman Coulter centrifuge, JA-14). The supernatant was incubated for 45min ...
-
bioRxiv - Biochemistry 2023Quote: ... the lysate was centrifuged at ∼18000g for 1h at 4°C (Beckman Coulter centrifuge, JA-20) and the supernatant incubated for 45min ...
-
bioRxiv - Microbiology 2020Quote: ... for 5 minutes using a FIBERLite F10BCI-6×500y rotor (Piramoon Technologies) in an Avanti JXN-30 centrifuge (Beckman Coulter). The clarified cell lysate was further centrifuged in a JS-24.38 rotor (Beckman Coulter ...
-
bioRxiv - Microbiology 2020Quote: VLPs were collected after removal of cells from the enrichment culture (7,000 rpm, 20 min, Sorvall 1500 rotor) and concentrated by ultracentrifugation (40,000 rpm, 2h, 10°C, Beckman SW41 rotor). The particles were resuspended in buffer A ...
-
bioRxiv - Molecular Biology 2019Quote: ... followed by ultracentrifugation at 100,000 g for 2h in polyallomer tubes at 4 °C in a SW40 rotor (Beckman Coulter). Pelleted material was washed two times in filtered PBS at 100,000 g for 2h and re-suspended in PBS ...
-
bioRxiv - Cancer Biology 2023Quote: ... Filtered supernatants were concentrated by ultracentrifugation at 22.000 rpm for 2h at 4°C with OptimaTM L-90K ultracentrifuge (Beckman Coulter) and stored at −80°C (never refrozen).
-
bioRxiv - Neuroscience 2022Quote: ... Insoluble material was removed by ultracentrifugation (1h, 4°C, 40,000 rpm, Ti70 rotor, Beckman Coulter Cat#337922). The fragments were immobilized onto glutathione Sepharose (Millipore/Cytiva Cat#17-5132-02 ...
-
bioRxiv - Biochemistry 2023Quote: ... After ultracentrifugation for 1h at 258,488 x g at 4°C using a TLS-55 rotor (Beckman), the fractions were analysed by SDS-PAGE and the positive fractions were concentrated ...
-
bioRxiv - Biochemistry 2023Quote: ... The lysate was then centrifuged at ∼28500g for 1h at 4°C (Beckman Coulter centrifuge, JA-14) and the supernatant incubated for 1h ...
-
bioRxiv - Biochemistry 2020Quote: ... One was through twice daily measurement of 2 or 3 levels of QC specimens obtained from Beckman Coulter Inc ...
-
bioRxiv - Biochemistry 2021Quote: ... Cells were incubated for 2h at 20°C in an AN60-Ti rotor in the Optima-AUC analytical ultracentrifuge (Beckman Coulter) before data acquisition for 15h at 42,000 rpm ...
-
bioRxiv - Molecular Biology 2020Quote: ... The gradients were centrifuged at 40000 rpm for 2h at 4°C in a SW 60 Ti swinging-bucket rotor (Beckman Coulter). Afterwards ...
-
bioRxiv - Microbiology 2024Quote: ... 450 µl of the lysate was carefully layered on top of the sucrose gradient and centrifuged at 35000 rpm (210000g) for 2h on a pre-chillled SW40 Ti rotor with the OptimaXL-100K ultracentrifuge system (Beckman Coulter). After the centrifugation ...
-
bioRxiv - Microbiology 2020Quote: ... 1mM dithiothreitol and 100μg/ml cycloheximide) and spun for 1h at 100K RPM using TLA-110 rotor (Beckman) at 4c ...
-
bioRxiv - Molecular Biology 2020Quote: ... Lysates were cleared by spinning at 3,000xg followed by 20,000xg for 10min each and supernatant were loaded on a 30% sucrose cushion and spun for 1h at 31,200 r.p.m in SW60 rotor (Beckman Coulter). The non-polysomal supernatant was removed and polysomes collected below the sucrose layer was diluted with the hypotonic buffer [10mM HEPES pH 7.8 ...
-
bioRxiv - Microbiology 2020Quote: ... 1mM dithiothreitol and 100μg/ml cycloheximide) and spun for 1h at 100K RPM using TLA-110 rotor (Beckman) at 4c ...
-
bioRxiv - Cell Biology 2021Quote: ... and centrifuged at 40,000 rpm (∼128,000 × g) for 3 h at 4°C using an MLS-5 rotor (Beckman Coulter). Aldolase (158 kDa ...
-
bioRxiv - Microbiology 2020Quote: ... were added into cells (1×106 cells/sample in 100 μL) and incubated for 60 min at 2-6°C and analyzed using flow cytometry (CytoFLEX, Beckman Coulter).
-
bioRxiv - Neuroscience 2023Quote: ... After PCR the samples were combined into small pool of 2-6 samples and size selection was carried out by adding 0.55x volume of AMPure XP beads (Beckman Coulter, #A68831). The concentrations of purified library pools were quantified with Collibri™ Library Quantification Kit (ThermoFisher ...
-
bioRxiv - Genomics 2020Quote: ... The PCR products were purified by using 1.3X Agencourt AMPure XP beads (2 or 3 cycles; Beckman Coulter) and evaluated by using an Agilent High Sensitivity DNA Kit on an Agilent 2100 Bioanalyzer (Agilent) ...
-
bioRxiv - Microbiology 2019Quote: ... and adding this to 3 ml sterile inoculum water (Beckman Coulter, Inc. Brea, CA, cat no B1015-2) and 840 μl phenol red solution ...
-
bioRxiv - Biochemistry 2021Quote: ... Lentivirus from the cell supernatant was collected 24h later by ultracentrifugation with a Sw28 rotor (Beckman Coulter; 22,000 rpm, 2h, 4°C). Finally ...
-
bioRxiv - Cancer Biology 2024Quote: ... The plates were then centrifuged at 2000 rpm (931 x g) for 2h at 30°C (Allegra® X-15R Centrifuge (Beckman Coulter), rotor SX4750A) ...
-
bioRxiv - Microbiology 2020Quote: ... the 100,000xg centrifugation was performed for 1h at 4°C using a SW41 TI swinging bucket rotor (Beckman Coulter). The pellet was then resuspended in 50 μL or 1500 μL of D-MEM for subsequent analysis.