Labshake search
Citations for Beckman :
351 - 400 of 1950 citations for 6 9 Methano 4 1 benzoxazepin 2 3H one octahydro 3 methyl 3 α 5a bta 6 bta 9 bta 9a bta 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2023Quote: ... Virus particles were collected by centrifugation at 32,000rpm for 2 hours at 4°C using the Optima XE-90 ultracentrifuge (Beckman Coulter). Virus was aliquoted and stored at -80°C until further use ...
-
bioRxiv - Cancer Biology 2023Quote: ... The gradients were ultracentrifuged at 35,000 rpm for 2 hrs at 4°C using an SW41 Ti rotor (Beckman Coulter). The gradients were then displaced into a UA-6 continuous UV detector (Teledyne ISCO ...
-
bioRxiv - Immunology 2023Quote: ... and purified and concentrated by ultracentrifugation on a 20% sucrose cushion (24,000 rpm and 4°C for 2 hours with a SW32Ti or SW28 rotor (Beckman Coulter)) ...
-
bioRxiv - Developmental Biology 2023Quote: ... The resulting supernatant was subjected to ultracentrifugation at 120,000 × g at 4°C for 2 h (Optima Max TL, Beckman Coulter). Pellets were resuspended in 1 ml cold PBS and centrifuged at 120,000 × g at 4°C for 2 h ...
-
bioRxiv - Cell Biology 2024Quote: ... Gradients were centrifuged at 36,000 rpm for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Following centrifugation ...
-
bioRxiv - Cell Biology 2024Quote: ... The same amounts of proteins were loaded on a double sucrose cushion (20% and 30% sucrose) and centrifuged at 190,000 g for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Extracts were incubated with pre-washed anti-Flag beads (Sigma ...
-
bioRxiv - Cell Biology 2023Quote: ... The samples were sedimented by velocity centrifugation at 36,000 x rpm for 2 h at 4°C using SW40Ti rotor in Optima L-80XP ultracentrifuge (Beckman Coulter). Absorbance at 254 nm was measured from lower to higher sucrose gradients using an ISCO gradient fractionation system and the optical density at 254 nm was continuously recorded with a Foxy JR Fractionator (Teledyne ISCO).
-
bioRxiv - Biochemistry 2021Quote: ... 1□mM EDTA) and centrifuged at 25000 rpm for 1 hour at 4°C (Beckman Coulter SW41-Ti rotor). Mitochondria forming a band at the interphase between the 1 M and 1.5 M sucrose were collected and resuspended in 10 mM Tris-HCl pH = 7.5 in 1:1 ratio ...
-
bioRxiv - Microbiology 2021Quote: ... Pool 1 and pool 2 amplicons were combined and purified with a 1:1 ratio of AMPureXP beads (Beckman Coulter) and eluted in 30 μL of sterile water ...
-
bioRxiv - Microbiology 2022Quote: ... Pool 1 and pool 2 amplicons were combined and purified with a 1:1 ratio of AMPureXP beads (Beckman Coulter) and eluted in 30 µL of RNAase free water ...
-
bioRxiv - Plant Biology 2023Quote: ... at 10,000 x g for 1 h at 4 ⁰C (JA-17 rotor, Beckman Coulter ...
-
bioRxiv - Biophysics 2023Quote: ... and at 4 °C for 1 hour for ultracentrifugation (70,658 g, Beckman, Type 70Ti) in vacuum ...
-
bioRxiv - Developmental Biology 2023Quote: ... cleared by ultracentrifugation at 100,000Lg for 1 hour at 4□°C (Beckman Coulter, 343775), then and vacuum-dried overnight.
-
bioRxiv - Biochemistry 2023Quote: ... for 1 hour at 4°C in a Type 45 Ti rotor (Beckman Coulter). The clarified lysate was then incubated with 5 mL of Ni-NTA agarose beads (Qiagen) ...
-
bioRxiv - Microbiology 2024Quote: ... 4°C for 1 h in a SW 41 Ti rotor (Beckman Coulter, Inc). The pellet was resuspended in 1 ml of PBS pH 7.4 ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... using a Beckman Coulter TLA100 rotor at 70,000 rpm at 4 C for 2 hours in a 13 mm x 51 mm polycarbonate ultracentrifuge tube (Beckman Coulter 349622). The sucrose solution was removed from the tube ...
-
Adaptive translational pausing is a hallmark of the cellular response to severe environmental stressbioRxiv - Molecular Biology 2020Quote: ... and centrifuged at 4°C at 31,000 rpm for 2 h and 30 min using an SW 32 Ti rotor(Beckman Coulter, 369694). The gradients were fractionated using a Teledyne ISCO Density Gradient Fractionation System and 12 fractions were collected ...
-
bioRxiv - Cancer Biology 2019Quote: ... Gradients were ultra-centrifuged at 221,600 × g for 2 hours at 4°C (SW-41Ti rotor, 331362, Beckman Coulter, Brea, CA). Gradients were fractionated (Piston Fractionator ...
-
bioRxiv - Immunology 2021Quote: ... Samples were spun at 76,650 x g for 2 hours at 4° C inside a SW 32i rotor using an Optima L-90K Ultracentrifuge (Beckman Coulter). Purified virus was quantified using a bicinchoninic acid assay (BCA ...
-
bioRxiv - Genomics 2021Quote: ... The samples were then centrifuged at 28,600 rpm for 2 h at 4°C (Beckman Optima XE-90; SW32 Ti rotor). After centrifugation ...
-
bioRxiv - Immunology 2020Quote: ... Vesicles recovered by ultracentrifugation of filtered supernatant at 150,000 x g for 2 h at 4 °C using a Ti 45 rotor (Beckman Instruments, USA), were washed with phosphate-buffered saline (PBS ...
-
bioRxiv - Neuroscience 2022Quote: ... layers F1/2 were removed before transferring the combined F3/4 layer into a clean 25mL centrifuge tube (Beckman Coulter, #355618) and diluting in GM buffer (at least 1:4 ...
-
bioRxiv - Bioengineering 2023Quote: ... The gradient tubes were balanced and subjected to centrifugation at 135,000 × g for 2 h at 4 °C using a fixed-angle rotor (TLA-55, Beckman Coulter, USA). After DGUC ...
-
bioRxiv - Bioengineering 2023Quote: ... The gradient tubes were subjected to centrifugation at 135,000 × g for 2 h at 4 °C using a fixed-angle rotor (TLA-55, Beckman Coulter, USA). After DGUC ...
-
bioRxiv - Bioengineering 2023Quote: ... The gradient tube was balanced and subjected to ultracentrifugation at 150,000 × g for 2 h at 4 °C using a swinging-bucket rotor (SW 41 Ti Beckman Coulter, USA).
-
A laboratory framework for ongoing optimisation of amplification based genomic surveillance programsbioRxiv - Genomics 2023Quote: ... PCR amplicons for pools 1 and 2 were combined for each sample and purified with a 1:1 ratio of AMPureXP beads (Beckman Coulter) and eluted in 30μL of sterile water ...
-
bioRxiv - Microbiology 2023Quote: ... Extracellular vesicles were isolated by ultracentrifugation (one hour at 100,000xg, Beckman Coulter The Optima™ MAX-XP ...
-
bioRxiv - Immunology 2021Quote: ... The pelleted exosomes from above supernatants were further centrifuged at 100,000g (26,450rpm) for 2 h at 4 °C (Beckman Coulter, Optima XE-90) and resuspended in PBS ...
-
bioRxiv - Microbiology 2021Quote: ... Samples were centrifuged at 130,000 × g for 2 h at 4°C in a TLA100.3 rotor (Beckman Optima TLX table top centrifuge). Following centrifugation ...
-
bioRxiv - Neuroscience 2021Quote: ... The post nuclear supernatant was transferred to an ultracentrifuge tube and centrifuged for 2 h at 245,000 g at 4 °C in a Beckman L90 Ultracentrifuge (Beckman Coulter, Mississauga, Canada) to pellet remaining membrane.
-
bioRxiv - Immunology 2022Quote: ... Ultracentrifugation in a Beckman L7-65 ultracentrifuge at 25,000 rpm for 2 hours at 4°C using a Beckman SW28 rotor (Beckman Coulter, CA, USA) was performed to pellet the viruses through the sucrose cushion while soluble egg proteins were removed ...
-
bioRxiv - Microbiology 2019Quote: ... and viruses were pelleted via ultracentrifugation for 2 hours at 125,000 x g at 4°C using an SW55-Ti rotor (Beckman Coulter, Indianapolis, IN). Following centrifugation ...
-
bioRxiv - Cell Biology 2023Quote: ... cells were blocked in 2% human serum and PBS for 30 min at 4°C and stained with DC-SIGN (Beckman Coulter #A07407), CD80 (BioLegend #305214) ...
-
bioRxiv - Plant Biology 2023Quote: ... 700 μl of obtained extract was applied to a chilled sucrose density gradient and centrifuged at 4 °C for 2 hours 45 minutes at 151,000 ×g using the SW 41 Ti rotor (Beckman Culture Life Sciences). After centrifugation ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysates were loaded onto the sucrose gradients and centrifuged at 40’000 rpm for 2 h at 4°C using the SW 41 Ti rotor (Beckman Coulter, Cat# 331362). Subsequently ...
-
bioRxiv - Biochemistry 2023Quote: ... Samples were centrifuged at 100,000 × g for 2 hr at 4 °C (Type 50.2 Ti Fixed angle ultracentrifuge rotor, Beckman Coulter, Brea, CA, USA). The supernatants were aspirated ...
-
bioRxiv - Cell Biology 2024Quote: ... Samples were centrifuged at 60,000 rpm at 4°C for 2 h on an SW65 Ti ultracentrifuge rotor (Beckman Coulter, California, USA). The pellets were gently washed by dispensing and removing 500 µl of ice-cold RNase-free water ...
-
bioRxiv - Developmental Biology 2023Quote: ... and centrifuged at 40,000 rpm for 1 h at 4°C (Beckman SW-41Ti rotor). Supernatants were discarded ...
-
bioRxiv - Microbiology 2021Quote: ... and extracellular vesicles including exosomes and virions were pelleted by ultracentrifugation at 141,000 g at 4 °C for 2 h in a swinging-bucket rotor (SW28; Beckman Coulter, Brea, CA, USA). The pellet was resuspended in filtered PBS and centrifuged at 18,300 g and 4°C for 10 min to remove insoluble aggregates ...
-
bioRxiv - Genomics 2020Quote: ... were layered onto a 1.8M sucrose cushion and ultra-centrifuged at 24,400 rpm at 4°C for 2 hours using a SW28 swinging bucket rotor (Beckman Coulter Optimal centrifuge #L90K). The nuclear pellet was re-suspended in 2% BSA in 1X PBS ...
-
bioRxiv - Microbiology 2020Quote: ... EMVs were obtained by ultracentrifugation from 4 mL of filtrate at 100,000 × g (average centrifugal force) and 4°C for 2 h with an OptimaX centrifuge (Beckman Coulter, Brea, CA, USA). The pellets were resuspended in 400 μL of Dulbecco’s phosphate-buffered saline (DPBS ...
-
bioRxiv - Neuroscience 2022Quote: ... The tubes were sealed and centrifuged at 50,000 rpm at 4°C for 2 h in an OptimaTM L-90K ultracentrifuge using the 70.1Ti rotor (Beckman Coulter, Brea, CA, USA). After the centrifugation ...
-
bioRxiv - Genomics 2019Quote: ... Libraries were purified one more time with SPRI Beads (Beckman Coulter, 1.5x). Libraries were quantified using a Qubit fluorometer (Life technologies ...
-
bioRxiv - Genomics 2021Quote: ... Libraries were purified one more time with SPRISelect reagent (Beckman Coulter, 1.5x). Libraries were quantified using a Qubit fluorimeter (Life technologies ...
-
bioRxiv - Cell Biology 2020Quote: ... and then the sample was centrifuged at 182,000g for 1 h at 4°C (Beckman SW40). LD fraction was carefully collected from the top band of the gradient and washed three times using 200 μL of buffer B ...
-
bioRxiv - Cell Biology 2022Quote: ... and incubated for 1 hr at +4°C before the flow cytometry analysis (Beckman Coulter CytoFlex) or sorting (SONY MA900) ...
-
bioRxiv - Biochemistry 2023Quote: ... The crude lysate was centrifuged for 1 hour at 20,000 rpm and 4 °C (Beckman Coulter). The supernatant was filtered using a 0.44 μm syringe filter (Sartorius ...
-
bioRxiv - Biophysics 2023Quote: ... The cell lysate was centrifuged at 4 °C at 35000 rpm for 1 hour by Beckman Optima™ L-80XP ultracentrifuge equipped with a Ti-45 rotor (Beckman ...
-
bioRxiv - Microbiology 2020Quote: ... and layered on top of a two-step sucrose gradient (20%/50% w/v in HNE) and centrifuged for 2 h at 154 000 x g at 4 °C in a SW41 rotor (Beckman Coulter, Woerden, the Netherlands) to clear from cell debris ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4°C (Beckman Coulter). The pellet containing lentiviral particles was suspended in the residual medium ...