Labshake search
Citations for Beckman :
451 - 500 of 1808 citations for 5 MORPHOLIN 4 YLPENT 3 YN 1 OL since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2023Quote: ... The microsomes were sedimented by centrifugation at 4°C in the TLA-55 rotor (Beckman) at 55,000 rpm for 20 min ...
-
bioRxiv - Cancer Biology 2024Quote: ... followed by ultracentrifuge concentration (25,000 rpm for 90 min at 4°C; Beckman SW32Ti rotor).
-
bioRxiv - Genomics 2020Quote: ... The PCR products were purified by using 1.3X Agencourt AMPure XP beads (2 or 3 cycles; Beckman Coulter) and evaluated by using an Agilent High Sensitivity DNA Kit on an Agilent 2100 Bioanalyzer (Agilent) ...
-
bioRxiv - Cell Biology 2021Quote: ... cell number and volume were measured in a parallel sample using a Multisizer 3 Coulter Counter (Beckman Coulter).
-
bioRxiv - Plant Biology 2021Quote: ... Cell density and mean cell diameter were measured using a Coulter Counter (Multisizer 3, Beckman Counter, Brea, CA). For the data in Figure 1A ...
-
bioRxiv - Molecular Biology 2022Quote: ... sucrose gradient buffer containing NEB75 or NEB300 and centrifuged at 50,000 rpm for 3 h at 4ºC using a TLS-55 rotor (Beckman). After centrifugation ...
-
bioRxiv - Microbiology 2019Quote: ... and adding this to 3 ml sterile inoculum water (Beckman Coulter, Inc. Brea, CA, cat no B1015-2) and 840 μl phenol red solution ...
-
bioRxiv - Plant Biology 2023Quote: ... Cell density and mean cell volume were measured using a Coulter Counter (Multisizer 3, Beckman Counter, Brea, CA). For 35°C with photoautotrophic medium ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3 mM BME and centrifuged for 18 h at 30,000 rpm in a Ti 50.2 rotor (Beckman Coulter) at 4°C ...
-
bioRxiv - Immunology 2024Quote: EVs isolated from cells were washed with ultracentrifugation for 3 hours with a SW41 Ti rotor (Beckman Coulter) at 100,000 x g at 4°C ...
-
bioRxiv - Microbiology 2024Quote: ... Four mL cultures at ∼10% parasitemia were harvested by centrifugation (2000 rpm for 3 min in a Beckman Coulter Allegra 25R table-top centrifuge ...
-
bioRxiv - Bioengineering 2024Quote: ... Distribution of microbubble diameter and concentration was acquired with a Coulter counter (Multisizer 3; Beckman Coulter, Fullerton, California) prior to sonication ...
-
bioRxiv - Cancer Biology 2021Quote: ... 5 mM MgCl2) and centrifuged at 36,000 rpm [SW40 Ti rotor (Beckman Coulter, inc)] for 2.15h at 4°C ...
-
bioRxiv - Bioengineering 2021Quote: ... and platelets were counted by a Hematology Analyzer (Beckman Coulter Act Diff 5 CP) according to the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2022Quote: ... 5 ml of this mix was transferred to a 17-ml ultracentrifuge tube (Beckman) and overlayed with the following sucrose solutions ...
-
bioRxiv - Neuroscience 2021Quote: ... The homogenate was centrifuged at 1,800 rpm for 10 min at 4°C (Beckman F0630 rotor) obtaining a supernatant (S1 ...
-
bioRxiv - Immunology 2019Quote: ... the blood tube was centrifuged in a refrigerated (4°C) centrifuge (Allegra X-15R, Beckman Coulter) at 2000xG for 15 minutes ...
-
bioRxiv - Molecular Biology 2019Quote: ... and centrifuged at 40,000 rpm/4 °C/16 hours using SW 40 Ti rotor (Beckman Coulter). Approximately 18 fractions were collected from each gradient ...
-
bioRxiv - Cell Biology 2021Quote: ... After centrifugation (285, 000 g for 2 h at 4 °C using a Beckman SW40Ti rotor), polysome profiles were recorded using an Äktaprime plus chromatography system (GE Healthcare) ...
-
bioRxiv - Biophysics 2021Quote: ... and centrifuged at 200,000 × g for 1.5 h at 4°C in an SW41Ti rotor (Beckman). Fractions (1 ml each ...
-
An oscillating MinD protein determines the cellular positioning of the motility machinery in archaeabioRxiv - Microbiology 2020Quote: The cell volume was analyzed with a Multisizer 4 Coulter Counter (Beckman Coulter, Brea, California, USA) equipped with a 30 nm aperture tube ...
-
bioRxiv - Cell Biology 2020Quote: ... and centrifuged for 90 min at 4 °C in an Optima L-90K ultracentrifuge (Beckman Coulter) at 28 000 rpm (~97 000 g ...
-
bioRxiv - Microbiology 2022Quote: ... 4°C for 2 h (SW 32 Ti swinging-bucket rotor, Optima LE-80K Beckman Coulter) using a 25% w/v sucrose cushion ...
-
bioRxiv - Biochemistry 2022Quote: ... Cells debris were pelleted by centrifugation (46,000 x g, 30 min, 4°C, Beckman 45Ti rotor). The supernatant was loaded overnight (in a closed circuit on a peristaltic pump ...
-
bioRxiv - Neuroscience 2022Quote: ... at 4°C in an Optima MAX-XP Ultracentrifuge with a TLA 120.1 rotor (Beckman Coulter). The supernatant (TBSE-soluble fraction ...
-
bioRxiv - Microbiology 2022Quote: ... and sedimented at 110,000 g for 20 min at 4°C (TLA-120.2 rotor, Beckman-Coulter). The supernatants and the cushions containing solubilized viral envelope and tegument proteins were carefully removed ...
-
bioRxiv - Cancer Biology 2022Quote: ... at 22,000 rpm at 4°C for two hours in an Optima XE 90 (Beckman Coulter). Lentiviral pellets were resuspended in the minimal residual media present after aspirating off supernatant ...
-
bioRxiv - Neuroscience 2020Quote: ... and centrifuged at 140,000 × g for 70 min at 4°C (# Optima-XE SW41 Beckman Coulter). The pellet was resuspended in 2 mL of 0.475M of sucrose solution (# S5-3 Fisher science ...
-
bioRxiv - Immunology 2022Quote: ... cells were fixed with 4% PFA-PBS and analyzed using a CytoFLEX flow cytometer (Beckman Coulter). ADCP assays were performed in two independent experiments ...
-
bioRxiv - Molecular Biology 2020Quote: ... Samples were ultracentrifuged at 95,000 rpm at 4°C for 2h using a TLA100.2 rotor (Beckman). The pellets were resuspended in 200 µL of W-Buffer and treated with 1% SDS (Sigma cat ...
-
bioRxiv - Biochemistry 2019Quote: ... After centrifugation of the lysate (JA-20 rotor, Beckman Coulter, 25000 g, 60 min, 4°C) the supernatant was loaded onto a Ni-NTA Agarose (Qiagen ...
-
bioRxiv - Microbiology 2019Quote: ... Cell debris was removed by centrifugation (Beckman JA-25.50, 48,000 x g, 4°C, 30 min), and the supernatant loaded onto a freshly charged 5 mL HisTrap FF Ni-affinity column (GE Healthcare ...
-
bioRxiv - Microbiology 2021Quote: ... followed by centrifugation for 15 min (14000 x g) at 4 °C (Beckman Coulter, Inc USA). The aqueous phase was transferred to a fresh 1.5 ml tube and the organic phase was kept for deoxyribonucleic acid (DNA ...
-
Plasma derived cell-free mitochondrial DNA originates mainly from circulating cell-free mitochondriabioRxiv - Genomics 2021Quote: ... and finally centrifuged at 200,000 g for 2h at 4°C (Beckman MLA-130 Ultracentrifuge Rotor). After each centrifugation step ...
-
bioRxiv - Microbiology 2020Quote: ... Gradients were resolved at 35,000 rpm for 2.5 hours at 4 °C in SW41 rotor (Beckman) and analysed and fractionated using Biocomp Gradient Station (BioComp Instruments ...
-
bioRxiv - Immunology 2021Quote: ... The multi-parameter data were collected within the BSL-4 using a Cytoflex LX (Beckman Coulter) and analyzed using FlowJo software (version 10.7.1 ...
-
bioRxiv - Plant Biology 2022Quote: ... and centrifuged at 45,000 rpm for 65 min at 4°C (Sorval NVT 90; Beckman Coulter). In parallel ...
-
bioRxiv - Biophysics 2022Quote: ... 100µL samples were then centrifuged at 42000rpm for 30min at 4°C (Beckman TLA 100 rotor). 2 fractions were isolated from these samples ...
-
bioRxiv - Neuroscience 2023Quote: ... and centrifuged at 53,000 RPM for 40 min at 4°C using a Ti70 rotor (Beckman). The supernatant was discarded and the pellet was transferred to a 2 mL tube in 50 μL PBS per g initial grey matter and resuspended by sonication using a Hielscher S26D11X10 Vial-Tweeter-Sonotrode in 0.5 s pulses at 100% amplitude for a total accumulated power of 200 W ...
-
bioRxiv - Plant Biology 2023Quote: ... Cell densities in the cultures were determined using a Multisizer 4 Coulter counter (Beckman, Brea, U.S.A).
-
bioRxiv - Cancer Biology 2023Quote: ... and ultracentrifuged at 100,000g for 90 min at 4°C (Optima L-90K Ultracentrifuge, Beckman Coulter). Pelleted EVs were resuspended in 200 μl PBS ...
-
bioRxiv - Immunology 2023Quote: ... and spun for 100 min at 38,000rpm at 4°C in a SW41Ti rotor (Beckman Ultracentrifuge). Gradients were syringe-fractionated mechanically from the bottom up and monitored for absorbance at 254nm (Teledyne Isco ...
-
bioRxiv - Microbiology 2023Quote: ... The gradient was centrifuged at 32,700 rpm for 18h at 4°C (Beckman SW41-Ti rotor). After the centrifugation ...
-
bioRxiv - Microbiology 2023Quote: ... Virions were then pelleted by ultracentrifugation (22 krpm, 90 min, 4 °C, Beckman-Coulter rotor SW28) on a 5-mL cushion of 30% sucrose ...
-
bioRxiv - Biochemistry 2023Quote: ... followed by lysate centrifugation at ∼28500g for 1h at 4°C (Beckman Coulter centrifuge, JA-14). The supernatant was incubated for 45min ...
-
bioRxiv - Biochemistry 2023Quote: ... the lysate was centrifuged at ∼28500g for 1h30 at 4°C (Beckman Coulter centrifuge, JA-14) and the supernatant incubated for 1h ...
-
bioRxiv - Biochemistry 2023Quote: ... the lysate was centrifuged at ∼18000g for 1h at 4°C (Beckman Coulter centrifuge, JA-20) and the supernatant incubated for 45min ...
-
bioRxiv - Microbiology 2019Quote: ... Conditioned media was then centrifuged at 36,000 × g for 3 hours at 4ºC (Type 45 Ti rotor, Beckman Coulter). OMV-containing pellets were resuspended in 2 mL ASW.
-
bioRxiv - Microbiology 2019Quote: ... The entire 3 ml mixture was placed at the bottom of a Beckman SW41 ultracentrifuge tube (Beckman, Munich, Germany) and subsequently overlaid with 5 ml of ice-cold 30% Optiprep in TNE and 4 ml of ice-cold 5% Optiprep in TNE ...
-
bioRxiv - Microbiology 2022Quote: ... phage suspension was layered on top of a 5–20 % sucrose (w/vol, in Tris-HCl pH 7.2 with 3 mM MgCl2 and 10 mM CaCl2) and centrifuged (Beckman Optima L-K90 ...