Labshake search
Citations for Beckman :
401 - 450 of 1777 citations for 6 Bromo 2 4 iodo phenyl imidazo 1 2 a pyridine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2023Quote: ... at 10,000 x g for 1 h at 4 ⁰C (JA-17 rotor, Beckman Coulter; Avanti J-20TM centrifuge, Beckman Coulter). The supernatant from this step was decanted into the new tubes and centrifuged at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor ...
-
bioRxiv - Cell Biology 2023Quote: ... loaded onto a discontinuous 0.75/1.0/2.33 M sucrose gradient and spin at 242,000 g for 1 h at 4 °C in a SW32Ti rotor (Beckman & Coutler). Growth cone fractions were collected at the interface load/0.75 M sucrose and non-growth cone fractions collected between 0.75/1.0 M sucrose and then analyzed by Western Blot.
-
bioRxiv - Molecular Biology 2023Quote: ... Ribosomes were isolated by sucrose cushion ultracentrifugation at 100,000 rpm at 4°C for 1 h using TLA110 rotor (Beckman Coulter). RNAs in the ribosome pellet were isolated with TRIzol-LS (Thermo Fisher Scientific ...
-
bioRxiv - Plant Biology 2023Quote: ... The tubes were then centrifuged at 100,000 x g for 1 h at 4 ⁰C (TLA 55 rotor, Beckman Coulter; OptimaTM Max ultracentrifuge, Beckman Coulter). The pellets from the tubes were pooled together in 500 µl of 20 mM Tris-HCl pH 6.0 buffer and the volume was brought up to 1,500 µl using 20 mM Tris-HCl ...
-
bioRxiv - Biophysics 2023Quote: ... Cell debris and unbroken cells were removed by centrifugation at 2,000 xg for 10 minutes and membranes were collected by ultracentrifugation at 186,000 xg for 1 hour at 4°C with a 45 Ti rotor (Beckman Coulter). The collected membrane was homogenized using a Dounce homogenizer in cold TBS buffer containing 1 mM PMSF ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was then transferred to polycarbonate tubes and centrifuged at 100,000 × g and 4°C for 1 h in a XL-90 ultracentrifuge (Beckman Coulter) ...
-
bioRxiv - Cell Biology 2022Quote: ... This spin was repeated and the resulting supernatant was then centrifuged for 1 h at 75,000 g at 4°C (TLA-100.3 rotor or Type60 Ti rotor; Beckman Coulter, USA). The supernatant was aspirated and the membrane pellet gently resuspended in microsome buffer (10 mM HEPES/KOH pH 7.5. ...
-
bioRxiv - Molecular Biology 2023Quote: ... for 45[min at 25°C and then subjected to a sucrose cushion ultracentrifugation at 100,000[rpm for 1[h at 4°C with Optima MAX-TL ultracentrifuge and TLA-110 rotor (Beckman Coulter). The RNA fragments in the resulting pellet were recovered using TRIzol reagent (Thermo Fisher Scientific ...
-
bioRxiv - Neuroscience 2023Quote: ... and centrifuged at 100,000 × g for 1 h at 4 °C using a TLA-55 rotor in an Optima TLX Ultracentrifuge (Beckman Coulter). The first supernatant ...
-
bioRxiv - Neuroscience 2024Quote: ... Digested samples were ultracentrifuged at 100,000x g for 1 h at 4 °C using a TLA-55 rotor (Beckman Coulter) to concentrate the insoluble ...
-
bioRxiv - Microbiology 2023Quote: ... Cells were washed twice with 200µl BD 1X Perm/Wash solution and stained 1h at 4°C with anti-HIV-1 p24 (RD1/PE, Beckman Coulter #6604667 ...
-
bioRxiv - Molecular Biology 2024Quote: ... Lysates were cleared by centrifugation for 1 h at 45,000 rpm at 4°C (Optima XPN-80 Ultracentrifuge with 70 Ti, Beckman Coulter). HTP-tagged proteins were immunoprecipitated with 600 µl pre-washed IgG-sepharose 6 fast flow affinity resin (GE Healthcare ...
-
bioRxiv - Neuroscience 2024Quote: ... The supernatant was ultracentrifuged at 80,000 × g for 1 h at 4°C using a type 50 Ti rotor ultracentrifuge (Beckman Coulter). The supernatant ...
-
bioRxiv - Microbiology 2023Quote: ... another 2 mL of staining bacterial samples was analyzed with a flow cytometry to check cell viability (Beckman CytoFLEX FCM, USA, Channel FL2-A: PE-A).
-
bioRxiv - Biophysics 2022Quote: ... and the supernatant was subjected to ultracentrifugation to separate the membrane fraction (100,000g, 1 hour, 4°C using an Optima XE-90, Beckman Coulter centrifuge). Membranes were resuspended in lysis buffer supplemented with cOmplete EDTA-free protease inhibitors (Roche) ...
-
bioRxiv - Cell Biology 2022Quote: ... A new supernatant was collected in a prechilled 1.5 ml ultracentrifuge tube and centrifuged at 100000 g for 1 h at 4°C in a TLA-55 rotor (Beckman Coulter). The resulting pellet was resuspended in the same isotonic buffer containing antiproteases and was frozen at -80°C together with the 100000 g supernatant ...
-
bioRxiv - Microbiology 2019Quote: ... The concentrated vesicles were washed twice with PBS by ultracentrifugation at 110,000xg at 4°C for 1 hour (Beckman Optma MAX-XP Ultracentrifuge, rotor TLA 120.2; Beckman Coulter Inc., USA). The final pellet (exosomes ...
-
bioRxiv - Systems Biology 2020Quote: ... each resultant fraction underwent separate ultracentrifugation at 100,000xg for 40 minutes at 4°C (rotor TLA 120.2) in 1 ml 11×34 mm polycarbonate uncapped centrifuge tubes (Beckman Coulter 343778). In EV-enriched pooled fraction experiments ...
-
bioRxiv - Microbiology 2020Quote: ... Vesicles were obtained by centrifugation at 38,400 x g for 1 h at 4°C in an Avanti J-20XP centrifuge (Beckman Coulter, Inc). Pelleted vesicles were resuspended in 20 ml of 50 mM HEPES (pH 6.8 ...
-
bioRxiv - Microbiology 2020Quote: ... cells were fixed with 4% FA in PBS for 90 min at room temperature and immunostained for intracellular HIV-1 CA for 30 min at 4°C using KC57-FITC antibody (Beckman Coulter) diluted in 0.1% Triton X-100 ...
-
bioRxiv - Cell Biology 2023Quote: ... Homogenates were then transferred to a 50 ml tube and centrifuged for 10 mins at 1 000 × g at 4°C (Beckman Coulter). The resulting supernatant was then transferred to microfuge tubes for storage at -80°C as whole liver lysates or to fresh ultracentrifuge tubes for further processing.
-
bioRxiv - Bioengineering 2023Quote: ... The suspension was then ultracentrifuged (58,000 × g, 1 hr., 4 °C) in an Optima MAX-XP (Beckman Coulter, Indianapolis, IN, USA) to separate residual catalyst ...
-
bioRxiv - Cell Biology 2024Quote: ... plasma samples were thawed on ice and subjected to ultracentrifugation at 100,000 g for 1 hr or 18 hr at 4 °C (TLA-55 rotor; Optima MAX-MP Tabletop Ultracentrifuge, Beckman Coulter). Pellets were washed once in 1.0 ml PBS ...
-
bioRxiv - Microbiology 2024Quote: ... The final Hcp1-VLPs particles were pelletized by ultracentrifugation at 274,000 ×g at 4°C for 1 h in a SW41 Ti rotor (Beckman Coulter, Inc). The final pellet was resuspended in PBS pH 7.4.
-
bioRxiv - Biochemistry 2020Quote: ... for 15 min at 4°C (Beckman centrifuge J-20-XP ...
-
bioRxiv - Biochemistry 2020Quote: ... for 15 min at 4°C (Beckman centrifuge J-20-XP ...
-
bioRxiv - Microbiology 2020Quote: ... 4°C in an SW55Ti rotor (Beckman), and the virus pellet harvested for analysis by WB with αGag.
-
bioRxiv - Biochemistry 2020Quote: ... for 15 min at 4°C (Beckman centrifuge J-20-XP ...
-
bioRxiv - Cell Biology 2020Quote: ... 4 °C with 70Ti rotor (Beckman Coulter) to collect sEV pellets in double 0.22 μm-filtered PBS ...
-
bioRxiv - Microbiology 2022Quote: ... 4 °C in SW41 rotor (Beckman Coulter). Samples were fractionated and collected using Biocomp Piston Gradient Fractionator (BioComp Instruments) ...
-
bioRxiv - Microbiology 2022Quote: ... 4 °C in SW28 rotor (Beckman Coulter). Gradients were fractionated using Biocomp Piston Gradient Fractionator (BioComp Instruments) ...
-
bioRxiv - Microbiology 2024Quote: ... 4 °C in SW41 rotor (Beckman Coulter). Polysomes profiles were obtained using Biocomp Piston Gradient Fractionator (BioComp Instruments ...
-
bioRxiv - Microbiology 2024Quote: ... 4°C (Optima TLX Ultracentrifuge, Beckman Coulter). The pellet was resuspended in 200 µL of ultrapure water.
-
bioRxiv - Synthetic Biology 2024Quote: ... 6 mM MgCl2) with 0.7 M sucrose in Ti-45 tubes (Beckman-Coulter). Ribosomes were pelleted by centrifugation at 27,000 rpm (57,000 xg ...
-
bioRxiv - Cell Biology 2021Quote: ... then finally at 100,000 g for 4 h at 4 ℃ using an SW28 rotor (Beckman Coulter, Fullerton, CA, USA). The pelleted exosomes were collected then subsequently resuspended in PBS ...
-
bioRxiv - Cell Biology 2021Quote: ... Hettich) at 4°C and then centrifuged at 40000 rpm for 4h30 at 4°C using SW41Ti rotor (Beckman). The supernatant was then UV inactivated at a wavelength of 254 nm for 4 min (3 times ...
-
bioRxiv - Microbiology 2023Quote: ... The lysates containing matured PsVs were loaded on an OptiPrep gradient that had been stabilized at least 1 h and centrifuged at 50k x g for 3.5-4 h at 4°C in a SW-55Ti rotor (Beckman). Fractions were collected in siliconized tubes and subjected to SDS-PAGE followed by Coomassie blue staining to assess the abundance of L1 and L2 proteins ...
-
bioRxiv - Cell Biology 2023Quote: ... Samples were spun at 200,000 × g at 4°C for 4 h in an MLS-50 rotor (Beckman Coulter), and 60 µL of top layer was collected ...
-
bioRxiv - Biophysics 2020Quote: ... The lysates were clarified by centrifugation (16,000 rpm for 1 h at 4°C, rotor JA 25.50, Beckman Coulter, Brea, California, USA). The supernatant was incubated with amylose resin for 1 h at 4°C and loaded onto a 20 ml chromatography column (Bio-Rad ...
-
bioRxiv - Systems Biology 2020Quote: ... Next the cultures were diluted 1:40 with 0.5M NaCl and immediately measured in Multisizer™4 COULTER COUNTER® (Beckman Coulter) (Coulter ...
-
bioRxiv - Plant Biology 2020Quote: ... Double size selection was carried out by adding 50 μL of a 1:4 (0.5X) mixture of AMPure XP Beads (Beckman Coulter, Brea, USA) to PEG buffer (20% PEG w/v ...
-
bioRxiv - Molecular Biology 2023Quote: ... The cell lysate was centrifuged at 4 °C at 35000 rpm for 1 hour with Beckman Optima™ L-80XP Ultracentrifuge equipped with Ti45 rotor (Beckman, USA). The pellet containing membranes and cell debris was discarded ...
-
bioRxiv - Neuroscience 2022Quote: ... The loaded gradient was ultracentrifuged at 69,150 x g for 1 h at 4 °C (SW 41 Ti Swinging-Bucket Rotor, Beckman Coulter, Cat. #331362) and the synaptosome fraction was harvested from the interface between the two sucrose layers ...
-
bioRxiv - Cell Biology 2023Quote: ... the supernatants were transferred into SW60 tubes (in vivo studies 1–4) or SW40 tubes (donated patients) (Beckman Coulter Inc., Brea, USA) and centrifuged at 10,000xg for 35 minutes ...
-
bioRxiv - Biophysics 2019Quote: ... Total volume was centrifuged at 10000 xg for 30 minutes at 4°C at 10000 xg for 30 minutes at 4 °C (Beckman Coulter Optima L-80 XP Ultracentrifuge ...
-
bioRxiv - Biochemistry 2020Quote: ... which were centrifuged at 50,000rpm for 4 hours at 4°C using a TLS55 rotor and an Optima MAX-XP Ultracentrifuge (Beckman Coulter). The sample was physically fractionated into 10 fractions of 85 uL each ...
-
bioRxiv - Molecular Biology 2022Quote: ... 800 µl of EDTA-treated lysate was layered on top of the sucrose gradient and ultracentrifuged at 35000 rpm for 4 hours at 4 °C in a SW41Ti rotor (Beckman). After centrifugation ...
-
bioRxiv - Immunology 2020Quote: ... all CCMV CP preparations were purified two times using an ultracentrifuge and 30% sucrose cushion – first with additional 0.5% Triton X-100 and the second time without Triton X-100 (4 h, 50 000 rmp, 4°C; Type 70Ti rotor, Beckman) and the pellet was then dissolved in buffer A ...
-
bioRxiv - Cell Biology 2022Quote: ... 4–40% sucrose gradient prepared in lysis buffer and centrifuged at 150,000 × g for 4 or 16 h at 4°C in a MLS-50 rotor (Beckman Coulter). Thereafter ...
-
bioRxiv - Neuroscience 2023Quote: ... the samples were filtered with a membrane pore size of 0.2 μm and centrifuged at 120,000 × g for 4 h at 4 °C in polycarbonate bottle assemblies (Beckman coulter, 355603) in a 70.1 Ti fixed angle rotor (Beckman coulter ...