Labshake search
Citations for Beckman :
401 - 450 of 1630 citations for 3 2 5 Dioxoimidazolidin 4 yl propanoic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2020Quote: ... The cells were counted using the electrical sensing zone method (Multisizer 3, Beckman Coulter, Indianapolis, IN)
-
bioRxiv - Microbiology 2023Quote: ... 3′ ligated RNA was cleaned by incubating with 2.5X volume of RNAClean XP beads (Beckman Coulter) and 1.5X volume of isopropanol for 15 min before separation on a magnetic rack ...
-
bioRxiv - Cancer Biology 2024Quote: ... Caspase 3 and 8 activity (EGFP+ cells) was analyzed using the CytoFLEX Flow Cytometer (Beckman Coulter) and Flowjo v10 BD (Becton Dickinson ...
-
bioRxiv - Cell Biology 2023Quote: ... Cell density and sizing was measured with a Coulter counter (Beckman Coulter Multisizer 3, CA, USA). Raw cell diameter event counts were converted to relative frequency and visualized as ridgeline plots with the R tidyverse packages (https://tidyverse.tidyverse.org/ ...
-
bioRxiv - Microbiology 2024Quote: ... The growth of each sample was determined by the Multisizer 3 coulter counter (Beckman Coulter, USA), and the absorption spectra of cells were measured using a UV-VIS spectrophotometer SPECORD® 210 PLUS with the aid of Integration skugel SPECORD (S/N ...
-
bioRxiv - Plant Biology 2024Quote: ... Cells were counted with a Beckman Coulter Multisizer 3 with a 50-µM orifice (Beckman Coulter).
-
bioRxiv - Microbiology 2020Quote: ... pH 7.4) and centrifuged at 182,000g for 1.5 h at 4°C (Beckman SW40). Then the lipid droplets on the top were collected and washed for further analysis.
-
bioRxiv - Systems Biology 2020Quote: ... pelleted at 3,709 xg for 4 min (Allegra X-30R, C0650 adaptor, Beckman Coulter), and resuspended in 50 mL of ice-cold deionized water (MilliQ Biocel A10 ...
-
bioRxiv - Cell Biology 2021Quote: ... at 4°C using the SW 55 Ti Swinging Bucket rotor (Beckman Coulter, 342194).
-
bioRxiv - Molecular Biology 2022Quote: ... After centrifugation at 6000 g for 15 min at 4 °C (JA14 rotor-Beckman), the cell pellet is resuspended with cold lysis buffer (1mg/ml lysozyme ...
-
bioRxiv - Cell Biology 2021Quote: ... After centrifugation (55,000 rpm, 80 min, 4°C) in a TLS55 rotor (Beckman Coulter), fractions were collected manually for precipitation with trichloroacetic acid (TCA ...
-
bioRxiv - Cell Biology 2021Quote: ... After centrifugation (38,000 rpm, 210 min, 4°C) in an SW41 rotor (Beckman Coulter), RNA content was measured at A254 while fractions were collected using a Foxy Jr ...
-
bioRxiv - Biochemistry 2020Quote: ... and spun at 90,000 rpm for 10 min at 4°C (TLA120.1 Beckman Coulter). After incubation at 37°C for 2 mins ...
-
bioRxiv - Cell Biology 2022Quote: ... and centrifuged at 4°C for 30min at 5,000xg and subsequently at 10,000xg (Beckman Coulter Optima XPN-80 with a SW60 rotor) ...
-
bioRxiv - Microbiology 2024Quote: ... 4°C for 1 h in a SW 41 Ti rotor (Beckman Coulter, Inc). The pellet was resuspended in 1 ml of PBS pH 7.4 ...
-
bioRxiv - Neuroscience 2024Quote: ... for 20 min at 4°C using the pre-cooled 70.1 rotor (Beckman, 342184). Pellets were kept on ice ...
-
bioRxiv - Cell Biology 2024Quote: ... and 10,000 g (30 min, 4 °C, SW28 rotor; Optima XPN Ultracentrifuge, Beckman Coulter) to pellet large EVs52 ...
-
bioRxiv - Cancer Biology 2024Quote: ... 10,000 × g for 30 min) at 4°C (Beckman Coulter Avanti J-E Centrifuge); filtered through a 0.22 μm PES filter (Genesee) ...
-
bioRxiv - Microbiology 2022Quote: ... The gradient was centrifuged at 100,000 × g for 18 h at 4°C (Beckman-Coulter XPN-80 Ultracentrifuge ...
-
bioRxiv - Plant Biology 2023Quote: ... at 10,000 x g for 1 h at 4 ⁰C (JA-17 rotor, Beckman Coulter ...
-
bioRxiv - Biophysics 2023Quote: ... and at 4 °C for 1 hour for ultracentrifugation (70,658 g, Beckman, Type 70Ti) in vacuum ...
-
bioRxiv - Developmental Biology 2023Quote: ... cleared by ultracentrifugation at 100,000Lg for 1 hour at 4□°C (Beckman Coulter, 343775), then and vacuum-dried overnight.
-
bioRxiv - Biochemistry 2023Quote: ... for 1 hour at 4°C in a Type 45 Ti rotor (Beckman Coulter). The clarified lysate was then incubated with 5 mL of Ni-NTA agarose beads (Qiagen) ...
-
bioRxiv - Biochemistry 2024Quote: ... and cleared by centrifugation at 4°C (18500 rpm, JA-25.50 Beckman, 20 min,). The clarified extract was purified on a 4 ml His60 Ni-IDA Superflow resin (Ozyme ...
-
bioRxiv - Biophysics 2024Quote: Cells were harvested (Beckman F10 BCL, 20 min at 6000 rpm and 4 °C), resuspend in PBS pH 7.4 ...
-
bioRxiv - Microbiology 2024Quote: Extracts were then diluted 20-fold (in 33% acetic acid) and their absorbance at A595 determined using a spectrophotometer (Beckman Coulter, DU-800).
-
bioRxiv - Cell Biology 2023Quote: ... either the dye was solubilized with 10% (v/v) acetic acid and the absorbance was measured at 570 nm in a spectrophotometer microplate reader (Beckman Coulter, Model AD340), or alternatively ...
-
bioRxiv - Biochemistry 2020Quote: ... Fragments were purified using 2 volumes AMPure XP beads (Beckman Coulter) and amplified for 8-10 cycles using NEBNext Multiplex Oligos ...
-
bioRxiv - Biochemistry 2021Quote: ... 6 mM 2-mercaptoethanol and centrifuged with a 70Ti (Beckman coulter) rotor at 40,000 rpm for 18 hours at 4°C ...
-
bioRxiv - Genomics 2022Quote: ... and purified with 2 rounds of AMPure XP beads (Beckman Coulter). Libraries were sequenced on an Illumina NextSeq 550 ...
-
bioRxiv - Biochemistry 2020Quote: ... Fragments were purified using 2 volumes AMPure XP beads (Beckman Coulter) and amplified for 8-10 cycles using NEBNext Multiplex Oligos ...
-
bioRxiv - Immunology 2021Quote: The ACCESS SARS-CoV-2 CLIA (Beckman Coulter Inc., California, USA) was used for semiquantitative detection of IgG directed against S protein RBD using serum obtained from venipuncture blood ...
-
bioRxiv - Genomics 2023Quote: ... prepare sucrose gradient in 2 ultracentrifuge buckets (Beckman Coulter cat: 344058) by layering 5 mL of Interphase buffer atop 10 mL of SCB in each ...
-
bioRxiv - Cell Biology 2021Quote: The average cell density in a population was measured by comparing Multisizer 3 Coulter Counter (Beckman Coulter)-based cell volume measurements and suspended microchannel resonator (SMR)-based buoyant mass measurements ...
-
bioRxiv - Plant Biology 2022Quote: ... The number of intact cells were measured using a Coulter Counter (Multisizer 3, Beckman Counter, Brea, CA).
-
bioRxiv - Cancer Biology 2022Quote: ... the genomic DNA was cleaned up with AMPure XP beads at 3:1 ratio (Beckman Coulter A63880) and eluted in the 10 mM Tris-HCl (pH 8.0) ...
-
bioRxiv - Neuroscience 2020Quote: ... Samples were analyzed using a 3-laser Beckman Coulter Gallios using Kaluza Software (Beckman Coulter, Brea, CA).
-
bioRxiv - Neuroscience 2020Quote: ... Samples were analyzed with a 3-laser Beckman Coulter Gallios using Kaluza Software (Beckman Coulter, Brea, CA).
-
bioRxiv - Genetics 2020Quote: ... (3) a 1x post ligation bead cleanup with AMPure XP beads (Beckman Coulter Life Sciences, IN, USA) was performed and (4 ...
-
bioRxiv - Biochemistry 2021Quote: ... Cells were washed 3x with PBS + 3% BSA and fluorescence was quantified using a CytoFLEX (Beckman Coulter) flow cytometer ...
-
bioRxiv - Plant Biology 2022Quote: ... The gradients were ultra-centrifuged for 3 h at 175,000g in a SW41Ti rotor (Beckman-Coulter, USA) and analyzed by measuring continuous absorbance at 260 nm using a Piston Gradient Fractionator (Biocomp Instruments) ...
-
bioRxiv - Cell Biology 2024Quote: ... Samples were centrifuged for 3 h at 40 000 rpm in a SW41swing out rotor (Beckman Coulter). The separated gradient was then fractionated by upward displacement with 55% sucrose solution using a gradient fractionator (Brandel Inc. ...
-
bioRxiv - Cell Biology 2023Quote: ... The positive ratio of SSEA-3+ cells was analyzed by the CytoFLEX S Flow Cytometer (Beckman Coulter). Flow cytometry data were analyzed by Kaluza Analysis Software (Beckman Coulter).
-
bioRxiv - Cancer Biology 2023Quote: ... Ca2+ dependent fluorescence intensity of Fluo-3/AM was measured by flow cytometry (CytoFLEX LX Beckman Coulter).
-
bioRxiv - Cell Biology 2023Quote: Cell size was measured directly by a Coulter Counter (Multisizer 3; Beckman-Coulter, Miami, Florida, United States). Mitotic index assay was determined as described previously (Umen and Goodenough ...
-
bioRxiv - Bioengineering 2023Quote: ... Microbubble concentration and number- and volume-weighted size distributions were measured with a Multisizer 3 (Beckman Coulter). Microbubble concentration (cl ...
-
bioRxiv - Cancer Biology 2024Quote: ... Cells were serially passed and counted every 3 days using the ViCell XR cell counter (Beckman Coulter).
-
bioRxiv - Biochemistry 2020Quote: ... Crosslinking reactions were loaded on 600µl 5∼35% glycerol gradients (Beckman 344090 tubes) in BC300N buffer and centrifuged for 4hr at 55,000rpm at 4°C in a TLS-55 rotor (with Beckman 356860 adaptors) ...
-
bioRxiv - Microbiology 2020Quote: ... Cells were pelleted at 200 x g 5 min in Allegra centrifuge (Beckman) and then resuspended in complete RPMI ...
-
bioRxiv - Microbiology 2024Quote: ... gradient (25 – 39 % OptiPrep, 309600 x g, 5 h, SW60Ti rotor (Beckman Coulter). Purification of VLPs was realized accordingly ...