Labshake search
Citations for Beckman :
401 - 450 of 513 citations for 2 3 Cyclohexenyl Ethyltrimethoxysilane since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2023Quote: The SARS-CoV-2 lentiviral pseudotyped neutralization assays were performed on integrated automation platforms consisting of a Biomek liquid handler from Beckman Coulter ...
-
bioRxiv - Cell Biology 2023Quote: ... Samples were ultracentrifuged at 4 °C and 150,000 ˗ g for 2 h (Optima L-80 XP Ultracentrifuge with Type 70.1 Ti Fixed-Angle Titanium Rotor (Beckman Coulter)) and supernatants were removed ...
-
bioRxiv - Microbiology 2022Quote: ... clarified using 0.2 µm filter and pelleted at 54,000 rpm (180,000 ×g) for 2 hours at 4 °C in a TLA-55 rotor in an Optima Max-XP tabletop ultracentrifuge (Beckman). The supernatant was removed ...
-
bioRxiv - Bioengineering 2022Quote: ... the conditioned media was subjected to an additional centrifugation step of 118,000 × g for 2 h in a Type 70 Ti ultracentrifuge rotor (Beckman Coulter). The resulting EV pellet was resuspended in 1X PBS and placed into a Nanosep 300 kDa MWCO spin column (Pall ...
-
bioRxiv - Cell Biology 2022Quote: ... the virus-cell mixture was centrifuged at 1,000 rcf for 2 hours at 32°C (Beckman Coulter, Allegra X-30R). Infected cells were then cultured as described above and subsequently FACS-sorted for the establishment of clonal cell lines.
-
bioRxiv - Microbiology 2023Quote: ... resuspended in 200 µl 2% PBS-BSA and analyzed for mean fluorescence intensity (MFI) of ACE2 expression with CytoFLEX flow cytometer (Beckman). To determine the biological effects of the purinergic receptor P2X7 and NLRP3 inflammasome on viral entry ...
-
bioRxiv - Biophysics 2023Quote: ... followed by layering the cleared lysate onto 40 mL of 2 M sucrose cushion and ultracentrifugation in Ti-45 rotor (Beckman) at 42,000 rpm for 2 hours ...
-
bioRxiv - Neuroscience 2023Quote: ... Fraction LP2 was obtained after centrifugation of fraction LS1 for 2 h at 165,000 g in a SW40 Ti rotor (Beckman, US). Corresponding supernatant was collected as Fraction LS2 ...
-
bioRxiv - Cancer Biology 2023Quote: ... Virus particles were collected by centrifugation at 32,000rpm for 2 hours at 4°C using the Optima XE-90 ultracentrifuge (Beckman Coulter). Virus was aliquoted and stored at -80°C until further use ...
-
bioRxiv - Microbiology 2024Quote: ... The pellets from different centrifuge tubes were pooled and resuspended in 1 mL of 1X PBS and pelleted again by ultracentrifugation at 165,700 x g for 2 h at 4°C in a TLA-55 rotor (Beckman Coulter). The pellet was resuspended in 500 µL of 1X PBS and stored at -20°C until use ...
-
bioRxiv - Microbiology 2024Quote: ... passed through 0.45 µm filters and concentrated on a 20% sucrose cushion (24,000 rpm at 4 °C for 2 h with a SW28 rotor (Beckman Coulter)) ...
-
bioRxiv - Microbiology 2024Quote: ... and purified and concentrated by ultracentrifugation on a 20% sucrose cushion (24,000 rpm and 4°C for 2 hours with a SW32Ti or SW28 rotor (Beckman Coulter)) ...
-
bioRxiv - Immunology 2024Quote: ... and EVs were isolated by ultracentrifugation (UC) at 100,000 x g for 2 h using a SW40 Ti rotor (Beckman Coulter) at 4°C ...
-
bioRxiv - Biochemistry 2024Quote: ... The supernatant containing the membrane fraction was transferred to Beckman ultracentrifuge tubes and subjected to ultracentrifugation for 2 h at 41,000 r.p.m (Beckman Optima L-100 XP ultracentrifuge, Beckman 45 Ti rotor). Membrane pellets were resuspended to a total protein concentration of 3.5 mg/mL in ice cold 1 x PBS using the Bicinchoninic Acid (BCA ...
-
bioRxiv - Biochemistry 2024Quote: ... were added to the desired concentration before clarification by ultracentrifugation at 247,000 x (g) for 10 minutes at 2°C in a TLA100 (Beckman Coulter). Glucose oxidase (GmbH ...
-
bioRxiv - Neuroscience 2024Quote: ... and the supernatant was ultracentrifuged at 100,000 g for 2 hours at 4°C with a 100 Ti rotor (Beckman Coulter) in a Beckman XL-90 ultracentrifuge ...
-
bioRxiv - Bioengineering 2024Quote: ... The standard GE-caveospheres and the disrupted GE-caveospheres were centrifuged at 120,000g for 2 hours in an TLA-55 Fixed-Angle Rotor of Optima MAX-XP Ultracentrifuge (Beckman coulter) followed by imaging of fluorescence using a ChemiDoc MP Imaging System as above ...
-
bioRxiv - Cancer Biology 2024Quote: ... The gradients were centrifuged at 40,000 rpm for 2 h at 4°C using a SW40 Ti rotor (Beckman Coulter). Eleven fractions of 500 µl each were collected and 200 µl and 50 µl were used for RNA and protein analysis ...
-
bioRxiv - Cell Biology 2024Quote: ... The supernatant from the 10,000xg spin was layered on top of a 2 mL 60% iodixanol cushion and spun for 4 hours at 100,000xg (SW32 Ti rotor, Beckman Coulter). The bottom 3 mL of the cushion was obtained and layered at the bottom of a discontinuous gradient ...
-
bioRxiv - Microbiology 2020Quote: ... were added into cells (1×106 cells/sample in 100 μL) and incubated for 60 min at 2-6°C and analyzed using flow cytometry (CytoFLEX, Beckman Coulter).
-
bioRxiv - Cell Biology 2020Quote: ... thin-layer cell preparations for confocal microscopy of enriched small luteal cells and large luteal cells was performed using Cytofuge 2 (Beckman Counter). Cells were then fixed with 10% neutral buffered formalin at 4 °C for 30 min ...
-
Phenotypic and molecular evolution across 10,000 generations in laboratory budding yeast populationsbioRxiv - Evolutionary Biology 2020Quote: ... We combined the 8 wells from column 2 of each plate and used the pooled culture to measure cell density on a Coulter Counter Z2 (Beckman Coulter). We spotted the entire volume of each of the other 88 wells on CSM-Arg (Sunrise Scientific ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... using a Beckman Coulter TLA100 rotor at 70,000 rpm at 4 C for 2 hours in a 13 mm x 51 mm polycarbonate ultracentrifuge tube (Beckman Coulter 349622). The sucrose solution was removed from the tube ...
-
bioRxiv - Genomics 2020Quote: The ∼400 bp amplicon product produced using both Pool-1 and Pool-2 from the same clinical sample was combined and purified using a 1X concentration of Agencourt AMPure XP beads (Beckman Coulter); the final product was eluted in 30 µl of elution buffer (Qiagen ...
-
bioRxiv - Cancer Biology 2020Quote: ... The donor-derived LT-HSC cell populations were sorted according to the gating strategy in Extended data Figure 2 using MoFlo Astrios Cell Sorter (Beckman Coulter). LT-HSC cells were directly sorted into 50μl RNA extraction buffer (ARCTURUS PicoPure RNA Isolation Kit (Applied Biosystems ...
-
bioRxiv - Microbiology 2022Quote: ... Washed pellets were resuspended in 2 mL 1x PBS and fluorescence was calculated using a LSR II cell analyzer (Beckman Coulter). Two biological replicates of 50,000 cell counts were analyzed with FlowJo ...
-
bioRxiv - Molecular Biology 2022Quote: Procyclic form cell lines for depletion of either TbPH1 or TbKifX2A were induced at a density of 2×106 cells/ml with 1 µg/ml doxycycline and growth monitored daily with a Z2 Coulter Counter Analyzer (Beckman Coulter). Cells were diluted back to the initial cell density every day ...
-
Adaptive translational pausing is a hallmark of the cellular response to severe environmental stressbioRxiv - Molecular Biology 2020Quote: ... and centrifuged at 4°C at 31,000 rpm for 2 h and 30 min using an SW 32 Ti rotor(Beckman Coulter, 369694). The gradients were fractionated using a Teledyne ISCO Density Gradient Fractionation System and 12 fractions were collected ...
-
bioRxiv - Neuroscience 2020Quote: ... the homogenized solution was added onto a sucrose cushion (2 ml) in a 10 ml Ultra-Clear centrifuge tube (Beckman Coulter). Separation of nuclei from the tissue was done by centrifugation (26.500xg at 4°C for 1.5 h ...
-
bioRxiv - Microbiology 2022Quote: ... filtered supernatant was underlaid with 20% sucrose PBS using a pipetting needle and centrifuged at 39 000 rpm for 2 h using an SW-41 rotor (Beckman Coulter). The supernatant and sucrose solution were carefully removed ...
-
bioRxiv - Microbiology 2022Quote: ... The virus suspension was pelleted through a 40% sucrose cushion by centrifugation for 2 h at 40,000 rpm in a SW55 Ti rotor (Beckman, Fullerton, CA) at 4°C ...
-
bioRxiv - Microbiology 2022Quote: ... Samples were incubated for 2 h at 16°C and double stranded cDNA was purified using AMPure XP beads (Beckman Coulter). For testing transcription activity of predicted genes ...
-
bioRxiv - Cell Biology 2021Quote: ... to remove cellular debris and purified by ultracentrifugation over a 25% sucrose cushion (28.000 rpm for 2 hours; Beckman Coulter ultracentrifuge).
-
bioRxiv - Cancer Biology 2021Quote: ... Cells were treated with 3 different doses of the conventional chemotherapy for 2 days and cell viability was assessed using a Vi-cell XR Viability Analyzer (Beckman Coulter); 6 replicates were performed for each cell line and each dose.
-
bioRxiv - Genetics 2020Quote: ... Reverse crosslinking reactions were incubated 2 h at 65°C and cleaned using Agencourt Ampure XP SPRI beads (Cat #A63880, Beckman Coulter) with a 2x bead:sample ratio ...
-
bioRxiv - Immunology 2021Quote: ... Beckman Coulter Access SARS-CoV-2 IgG assays (Brea, CA, USA) targeting the RBD were performed on UniCel DxI 800 Access Immunoassay System (Beckman Coulter). Index value threshold for positivity was 1 as recommended ...
-
bioRxiv - Immunology 2020Quote: ... erythrocytes in 2 μl blood (collected from the tail tip) were counted using a Z2 Coulter Particle count and size analyser (Beckman Coulter). We determined the healthy range in uninfected C57Bl/6J mice housed in our facility to be 8.8 - 10.5*109 erythrocytes*ml−1 ...
-
bioRxiv - Microbiology 2021Quote: ... and either aliquoted or concentrated by ultracentrifugation using 20% (w/v) sucrose cushions for 2 hours at 25,000 rpm in an SW41 or SW28 rotor (Beckman, Indianapolis, IN). Alternatively ...
-
bioRxiv - Immunology 2020Quote: ... 2) first-round PCRs were set up using a Biomek FX liquid handling system with a 96- well head (Beckman Coulter); 3 ...
-
bioRxiv - Immunology 2021Quote: ... Samples were spun at 76,650 x g for 2 hours at 4° C inside a SW 32i rotor using an Optima L-90K Ultracentrifuge (Beckman Coulter). Purified virus was quantified using a bicinchoninic acid assay (BCA ...
-
bioRxiv - Genomics 2021Quote: ... The samples were then centrifuged at 28,600 rpm for 2 h at 4°C (Beckman Optima XE-90; SW32 Ti rotor). After centrifugation ...
-
bioRxiv - Immunology 2020Quote: ... Vesicles recovered by ultracentrifugation of filtered supernatant at 150,000 x g for 2 h at 4 °C using a Ti 45 rotor (Beckman Instruments, USA), were washed with phosphate-buffered saline (PBS ...
-
bioRxiv - Microbiology 2023Quote: ... viruses were collected and concentrated by ultracentrifugation (37,000 rpm, 2 h 30, 15 °C; Beckman Type 45 Ti fixed-angle rotor). The virus titer was determined using a plaque assay.
-
bioRxiv - Microbiology 2023Quote: ... the DNA monitored on 2% agarose gel was purified by means of AMPure XT beads (Beckman Coulter Genomics, Danvers, MA, USA) and quantified by Qubit (Invitrogen ...
-
A laboratory framework for ongoing optimisation of amplification based genomic surveillance programsbioRxiv - Genomics 2023Quote: ... PCR amplicons for pools 1 and 2 were combined for each sample and purified with a 1:1 ratio of AMPureXP beads (Beckman Coulter) and eluted in 30μL of sterile water ...
-
bioRxiv - Genomics 2024Quote: ... The crude nuclei were stained with 4,6-diamidino-2-phenylindole (DAPI) and loaded into a flow cytometer (Beckman Coulter, MoFlo XDP). Nuclei were purified by flow sorting and washed as described previously [61] ...
-
bioRxiv - Microbiology 2024Quote: Intracellular HIV-1 p24 staining was performed on fixed U1 and ACH-2 cells with KC57-FITC (Beckman Coulter, Cat#6604665). After allowing at least 30 minutes for fixation ...
-
bioRxiv - Bioengineering 2023Quote: ... The gradient tubes were balanced and subjected to centrifugation at 135,000 × g for 2 h at 4 °C using a fixed-angle rotor (TLA-55, Beckman Coulter, USA). After DGUC ...
-
bioRxiv - Bioengineering 2023Quote: ... The gradient tubes were subjected to centrifugation at 135,000 × g for 2 h at 4 °C using a fixed-angle rotor (TLA-55, Beckman Coulter, USA). After DGUC ...
-
bioRxiv - Bioengineering 2023Quote: ... The gradient tube was balanced and subjected to ultracentrifugation at 150,000 × g for 2 h at 4 °C using a swinging-bucket rotor (SW 41 Ti Beckman Coulter, USA).